921 resultados para lead-cadmium fluoride
Resumo:
A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l(-1) HNO3 and in 1 + 1 v/v diluted wine using mixtures of Pd(NO3)(2) + Mg(NO3)(2) and NH4H2PO4 + Mg(NO3)(2) as chemical modifiers. With 5 mug Pd + 3 mug Mg as the modifiers and a two-step pyrolysis (10 s at 400 degreesC and 10 s at 600 degreesC), the formation of carbonaceous residues inside the atomizer was avoided. For 20 mul of sample (wine + 0.056 mol l(-1) HNO3, 1 + 1, v/v) dispensed into the graphite tube, analytical curves in the 0.10-1.0 mug l(-1) Cd and 5.0-50 mug l(-1) Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 mug l(-1) for Cd, 0.8 mug l(-1) for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 mug l(-1) and for Pb at 500 mug l(-1). The relative standard deviations (n = 12) were typically < 8% for Cd and < 6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Ph was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
The molar single ion activity coefficients associated with hydrogen, copper(II), cadmium(II) and lead(II) ions were determined at 25 degrees C and ionic strengths between 0.100 and 3.00 M (NaClO4), whereas for acetate the ionic strengths were fixed between 0.300 and 2.00 M, held with the same inert electrolyte. The investigation was carried out potentiometrically by using proton-sensitive glass, copper, cadmium and lead ion-selective electrodes and a second-class Hg\Hg-2(CH3COO)(2) electrode. It was found that the activity coefficients of these ions (y(i)) can be assessed through the following empirical equations:log y(H) = -0.542I(0.5) + 0.451I; log y(Cu) = -1.249I(0.5) + 0.912I; log y(Cd) = -0.829I(0.5) + 0.448I(1.5);log y(Pb) = -0.404I(0.5) + 0.117I(2); and log y(Ac) = 0.0370I .
Resumo:
Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma-mass spectrometry (ICP-MS). Prior to analysis, 200 l of blood samples was mixed with 500 l of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 g//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Sante Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 g/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.
Resumo:
A new strategy for minimization of Cu2+ and Pb2+ interferences on the spectrophotometric determination of Cd2+ by the Malachite green (MG)-iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd2+ in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO3, 0.1% (v/v) H2SO4 and 0.5 M NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd2+ is extracted as CdCl4/2-. Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb2+ and Cu2+ levels up to 50 and 250 mg 1-1, respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00-50.0 μg Cd 1-1 range (r2 = 0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 μg Cd 1-1. The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 μg Cd 1-1 was 3.85% (n = 12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%. (C) 2000 Elsevier Science B.V.
Resumo:
The biosorption of Cd(II) and Pb(II) ions on biomass and exopolysaccharide (EPS) produced by Colletotrichum sp. fungus has been investigated as a function of contact time, initial pH, initial metal ion concentration, and initial adsorbent concentration in a batch system. Adsorption equilibrium was described by Freundlich and Langmuir isotherms. Adsorption was characterized through granulometry, SEM and EDX analysis. Then, studies were performed to regenerate the adsorbent. Biosorption of metals by biomass and EPS were best described by the Langmuir and Freundlich isotherm, respectively. Results of thermodynamic investigations showed that adsorption reactions were spontaneous (ΔG° < 0), exothermal, and mainly physical. The EPS was able to remove 79 and 98% of cadmium and lead, respectively, and the biomass removed 85 and 84% of cadmium and lead, respectively, in a solution with initial concentration 100 mg L-1, and the four adsorption-desorption cycles of all adsorbents showed up with great regenerative capacity and relative stability after these four cycles, the high potential of these biological materials in sorption has been shown. © 2013 Copyright Balaban Desalination Publications.
Resumo:
Agricultural use of tannery sludge (TS) may increase risks to soils. Thus, composting is recognized as one of the most suitable alternatives for TS recycling. Field experiments were carried out to evaluate the effects of composted tannery sludge (CTS) on chromium (Cr), cadmium (Cd), nickel (Ni), and lead (Pb) accumulation in soil after 3 years. Soil samples were collected 60 days after CTS application. After 3 years, The CTS increased Cr and Ni content, while Cd and Pb contents decreased. The third year, Cr contents showed linear increases as CTS rates were applied. The application of CTS, after 3 years, in the 2.5, 5, and 10 Mg ha(-1) increased Cr significantly (140.7%, 159.7%, and 19%, respectively) and Ni (32%, 53%, and 43.8%, respectively) contents in the soil surface layer. This means that consecutive amendments of CTS increase Cr contents in the soil and plants.
Resumo:
Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma–mass spectrometry (ICPMS). Prior to analysis, 200 ml of blood samples was mixed with 500 ml of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 mg//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Santé Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 mg/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.
Resumo:
Distribution of Cd and Pb in sea ice and in under-ice water of the Amur Bay at the end of February 1998 is considered. The metals were determined by technique of inversion voltammetry. Contribution of Cd and Pb from atmospheric precipitation and from under-ice water to sea ice examined is discussed. On the basis of analysis of vertical distribution in ice, atmospheric fluxes supplying metals to the aquatic area of the bay are estimated at 100 and 2000 µg/m**2/year for Cd and Pb, respectively. Concentrations of Cd and Pb found in middle and lower parts of ice cores allow to suggest that their accumulation relative to main ions of seawater occurs in the ice. Estimated enrichment factors of Cd and Pb in sea ice relative to seawate are ~9 and ~5. A possible mechanism of relative metal accumulation in sea ice is considered.
Resumo:
Organic carbon, lead and cadmium contents of 20 sediments were determined and compared with the colony counts of anaerobic heterotrophic, anaerobic nitrogen fixing, chitinoclastic and cellulolytic bacteria. Organic carbon content, which is dependent on the sediment type, was positively correlated with lead and cadmium as well as with colony counts of all 4 physiological groups of bacteria. Even the sediments with the highest concentrations of 251.7 ppm Pb and 3.1 ppm Cd showed no reduction in their colony counts. From 2 different sediment sampIes with lead contents of 140 ppm and 21 ppm lead tolerance of the aerobic heterotrophic bacteria was investigated. However, no significant difference in lead tolerance of the 2 heterotrophic populations was found. Water from 6 stations was analysed for dissolved and particulate organic carbon, lead and cadmium. Dissolved lead concentrations were in the range of 0.2-0.5 µg/l and the particulate lead contents were between 0.05 and 4.3 µg/l. The concentrations of total lead for the stations off-shore were only one order of magnitude from the concentrations of the near-shore stations. The same phenomenon was observed for dissolved cadmium (0.02 - 0.25 µg/l) and particulate cadmium (0.003 - 0.15 µg/I) concentrations. Correlations between dissolved (1.6 - 10.8 mg/I) and particulate organic carbon (0.25 - 1.53 mg/I) with dissolved and particulate lead or cadmium were not found.
Resumo:
"Contributions from the Chemical Laboratory of Harvard College."