940 resultados para in-field detection


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several methods of mutation detection, such as single-strand conformation polymorphism (SSCP), tandem SSCP/heteroduplex analysis and SNaPshot analysis were developed using homemade kit on ABI 310 genetic analyzer, and were successfully applied to mutation detection of 31 colorectal tumor samples. The sieving capability of homemade kit and commercial kit were compared, results demonstrate that homemade kit has higher resolution and shorter analysis time. In clinical tumor samples, 26% K-ras (exon 1) and 24% p53 (exons 7-8) were found to have mutations, and all mutations were single point variations. A majority of mutations occurred in one gene, only 1 tumor contained alterations in the two genes, which indicates that development of colorectal cancer lies on alternate pathways, and may correlate with different gene mutations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A controllable silver nanoparticle aggregate system has been synthesized by adding different amounts of ethanol to cetyltrimethylammonium bromide (CTAB) capped silver nanoparticles (Ag-nps), which could be used as highly efficient surface-enhanced Raman scattering (SERS) active substrates. This ethanol-induced aggregation can be attributed to preferential dissolution of CTAB into ethanol, which leads a partial removal of the protective CTAB layer on Ag-nps. The optical and morphological properties of these aggregates under various volumes of ethanol were explored via UV-vis spectroscopy and atomic force microscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A diode with a reverse rectifying characteristics was fabricated based on the organic heterojunction of copper phthalocyanine (CuPc) and copper-hexadecafluoro-phthalocyanine (F16CuPc). At the heterojunction interface, HOMO of CuPc is bended upwards and LUMO of F16CuPc is bended downwards, since the charge carriers were accumulated at both side of the interface, electrons in F16CuPc and holes in CuPc. The thickness of holes accumulated at the CuPc layer is about 10 nm. which was determined by fabricating organic field-effect transistors with active layers in series of thickness. By utilizing the heterojunction-effect, the threshold voltage in organic transistors can be modified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As a high efficiency separation technique, capillary electrophoresis(CE) has been widely used in various fields of analytical science. Amperometry is one of the most sensitive electrochemical detection methods in CE. The capillary/electrode decoupling mechanism, applications,of new electrode systems in CE, detection cell technique are discussed in detail. Amperometric detection is compatible with microfabricated CE chips and will make the concept of lab-on-a-chip become a reality. Because of these progresses, amperometry is becoming a widely acceptable detection method,for more chemical and biological analytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Luis A.J. Mur, I. Edi Santosa, Lucas J.J. Laarhoven, Nicholas J. Holton, Frans J.M. Harren and Aileen R. Smith (2005). Laser photoacoustic detection allows in planta detection of nitric oxide in tobacco following challenge with avirulent and virulent pseudomonas syringae pathovars. Plant Physiology, 138(3), 1247-1258. Sponsorship: BBSRC / EU RAE2008

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current evidence increasingly suggests that very short, supra-maximal bouts of exercise can have significant health and performance benefits. The majority of research conducted in the area however, uses laboratory-based protocols, which can lack ecological validity. The purpose of this study was to examine the effects of a high intensity sprint-training programme on hockey related performance measures. 14 semi-professional hockey players completed either a 4-week high intensity training (HIT) intervention, consisting of a total of six sessions HIT, which progressively increased in volume (n=7), or followed their normal training programme (Con; n=7). Straight-line sprint speed with and without a hockey stick and ball, and slalom sprint speed, with and without a hockey stick and ball were used as performance indicators. Maximal sprint speed over 22.9m was also assessed. Upon completion of the four-week intervention, straight-line sprint speed improved significantly in the HIT group (~3%), with no change in performance for the Con group. Slalom sprint speed, both with and without a hockey ball was not significantly different following the training programme in either group. Maximal sprint speed improved significantly (12.1%) in the HIT group, but there was no significant performance change in the Con group. The findings of this study indicate that a short period of HIT can significantly improve hockey related performance measures, and could be beneficial to athletes and coaches in field settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding animals' spatial perception is a critical step toward discerning their cognitive processes. The spatial sense is multimodal and based on both the external world and mental representations of that world. Navigation in each species depends upon its evolutionary history, physiology, and ecological niche. We carried out foraging experiments on wild vervet monkeys (Chlorocebus pygerythrus) at Lake Nabugabo, Uganda, to determine the types of cues used to detect food and whether associative cues could be used to find hidden food. Our first and second set of experiments differentiated between vervets' use of global spatial cues (including the arrangement of feeding platforms within the surrounding vegetation) and/or local layout cues (the position of platforms relative to one another), relative to the use of goal-object cues on each platform. Our third experiment provided an associative cue to the presence of food with global spatial, local layout, and goal-object cues disguised. Vervets located food above chance levels when goal-object cues and associative cues were present, and visual signals were the predominant goal-object cues that they attended to. With similar sample sizes and methods as previous studies on New World monkeys, vervets were not able to locate food using only global spatial cues and local layout cues, unlike all five species of platyrrhines thus far tested. Relative to these platyrrhines, the spatial location of food may need to stay the same for a longer time period before vervets encode this information, and goal-object cues may be more salient for them in small-scale space.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background & Aims: Wide between-center variation in adenoma detection rates (ADRs) was observed in the U.K. Flexible Sigmoidoscopy Screening Trial (overall, 12.1%; range, 8.6%-15.9%; P <0.0001). The aim of this study was to determine whether the observed differences could be attributed to varying performance by endoscopists, to examine the effect of experience on performance, and to identify an attainable, standard ADR to which endoscopists could aspire. 

Methods: Thirteen medical endoscopists, one per trial center, each performed about 3000 examinations (200 per month) using the same equipment and protocol. Overall and monthly ADRs were compared using multivariable logistic regression. 

Results: Differences in ADRs were not explained by patient characteristics, incidence of colorectal cancer in the local population, or the endoscopists' medical specialty or previous experience. Average ADRs increased significantly with screening experience (up to 400 examinations). Endoscopists were classified as higher, intermediate, or lower adenoma detectors, and performance levels were maintained over time. Higher detectors had ADRs of 15% overall (men, 20%; women, 10%) and also detected more adenomas per case (higher/lower detectors, 21.7/10.4 adenomas per :100 examinations). 

Conclusions: The differences in ADRs were due to variation in performance of the endoscopists. Long-term follow-up will determine whether this variation is clinically important. We suggest that the standards in higher detecting centers should be achievable by all endoscopists screening unscreened populations aged older than 55 years. Endoscopists should aim to stay above the lower 95% confidence interval band for 200 examinations (10% overall; 5% in women, 15% in men).