993 resultados para implant impression technique


Relevância:

40.00% 40.00%

Publicador:

Resumo:

An optimal esthetic implant restoration is a combination of a visually pleasing prosthesis and surrounding peri-implant soft tissue architecture. This article introduces a clinical method, the dynamic compression technique, of conditioning soft tissues around bone-level implants with provisional restorations in the esthetic zone. The technique has several goals: to establish an adequate emergence profile; to recreate a balanced mucosa course and level in harmony with the gingiva of the adjacent teeth, including papilla height/width, localization of the mucosal zenith and the tissue profile's triangular shape; as well as to establish an accurate proximal contact area with the adjacent tooth/implant crown.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Extended grafting procedures in atrophic ridges are invasive and time-consuming and increase cost and patient morbidity. Therefore, ridge-splitting techniques have been suggested to enlarge alveolar crests. The aim of this cohort study was to report techniques and radiographic outcomes of implants placed simultaneously with a piezoelectric alveolar ridge-splitting technique (RST). Peri-implant bone-level changes (ΔIBL) of implants placed with (study group, SG) or without RST (control group, CG) were compared. MATERIALS AND METHODS Two cohorts (seven patients in each) were matched regarding implant type, position, and number; superstructure type; age; and gender and received 17 implants each. Crestal implant bone level (IBL) was measured at surgery (T0), loading (T1), and 1 year (T2) and 2 years after loading (T3). For all implants, ΔIBL values were determined from radiographs. Differences in ΔIBL between SG and CG were analyzed statistically (Mann-Whitney U test). Bone width was assessed intraoperatively, and vertical bone mapping was performed at T0, T1, and T3. RESULTS After a mean observation period of 27.4 months after surgery, the implant survival rate was 100%. Mean ΔIBL was -1.68 ± 0.90 mm for SG and -1.04 ± 0.78 mm for CG (P = .022). Increased ΔIBL in SG versus CG occurred mainly until T2. Between T2 and T3, ΔIBL was limited (-0.11 ± 1.20 mm for SG and -0.05 ± 0.16 mm for CG; P = .546). Median bone width increased intraoperatively by 4.7 mm. CONCLUSIONS Within the limitations of this study, it can be suggested that RST is a well-functioning one-stage alternative to extended grafting procedures if the ridge shows adequate height. ΔIBL values indicated that implants with RST may fulfill accepted implant success criteria. However, during healing and the first year of loading, increased IBL alterations must be anticipated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Growth rods are commonly used for the treatment of scoliosis in the immature spine. Many variations have been proposed but breakage of implants is a common problem. Growth rod insertion commonly involves large exposures at initial insertion followed by multiple smaller procedures for lengthening. We present our early experiences using a percutaneous technique of insertion of a new titanium mobile bearing implant (Medtronic Inc). The implant allows some rotatory motion in the middle of the construct thus reducing construct stresses and thus possibly reducing rod breakage risk. Based on this small initial series with 12 months follow-up, percutaneous insertion of growth rods using the new implant is a safe and reliable technique although the infection rate in our sample was of note. This may be related to the titanium wear and inflammation seen in the soft tissues at time of operation and visualised on histology. No implants have required removal due to infection, and all infections were treated with debridement at next lengthening and suppressive antibiotics. Propionibacterium is one of the commonest infections seen with spinal implants and sometimes does not respond to simple antibiotic suppression. The technique allows preservation of the soft tissues until definitive fusion is needed and may lead to a decrease in hospital stay. The implant is low profile and seems to offer advantages over other systems on the market. Further follow up is needed to look at longer term outcomes with this new implant type.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose Our aim was to prove in an animal model that the use of HA paste at the cement-bone interface in the acetabulum would improve fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylemethacrylate (PMMA). Methods We made a randomized study involving 22 sheep to test whether the application of BoneSource hydroxyapatite material to the surface of the ovine acetabulum prior to cementing a polyethylene cup at hip arthroplasty improved the fixation and the nature of the interface. We studied the gross radiographical appearance of the implant-bone interface and the histological appearance at the interface. Results There were more radiolucencies evident in the control group. Histologically, only sheep randomized into the BoneSource group exhibited a fully osseointegrated interface. Use of the hydroxyapatite material did not confer any detrimental effects. In some cases the material appeared to have been fully resorbed. When the material was evident on histological section, it was incorporated into an osseointegrated interface. There was no giant cell reaction present in any case. There was no evidence of migration of BoneSource to the articulation. Interpretation The application of HA material prior to cementation of a socket produced an improved interface. The technique may be useful in man with to extend the longevity of the cemented implant by protecting the socket interface from the effect of hydrodynamic fluid flow and particulate debris.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main causes of above knee or transfemoral amputation (TFA) in the developed world is trauma to the limb. The number of people undergoing TFA due to limb trauma, particularly due to war injuries, has been increasing. Typically the trauma amputee population, including war-related amputees, are otherwise healthy, active and desire to return to employment and their usual lifestyle. Consequently there is a growing need to restore long-term mobility and limb function to this population. Traditionally transfemoral amputees are provided with an artificial or prosthetic leg that consists of a fabricated socket, knee joint mechanism and a prosthetic foot. Amputees have reported several problems related to the socket of their prosthetic limb. These include pain in the residual limb, poor socket fit, discomfort and poor mobility. Removing the socket from the prosthetic limb could eliminate or reduce these problems. A solution to this is the direct attachment of the prosthesis to the residual bone (femur) inside the residual limb. This technique has been used on a small population of transfemoral amputees since 1990. A threaded titanium implant is screwed in to the shaft of the femur and a second component connects between the implant and the prosthesis. A period of time is required to allow the implant to become fully attached to the bone, called osseointegration (OI), and be able to withstand applied load; then the prosthesis can be attached. The advantages of transfemoral osseointegration (TFOI) over conventional prosthetic sockets include better hip mobility, sitting comfort and prosthetic retention and fewer skin problems on the residual limb. However, due to the length of time required for OI to progress and to complete the rehabilitation exercises, it can take up to twelve months after implant insertion for an amputee to be able to load bear and to walk unaided. The long rehabilitation time is a significant disadvantage of TFOI and may be impeding the wider adoption of the technique. There is a need for a non-invasive method of assessing the degree of osseointegration between the bone and the implant. If such a method was capable of determining the progression of TFOI and assessing when the implant was able to withstand physiological load it could reduce the overall rehabilitation time. Vibration analysis has been suggested as a potential technique: it is a non destructive method of assessing the dynamic properties of a structure. Changes in the physical properties of a structure can be identified from changes in its dynamic properties. Consequently vibration analysis, both experimental and computational, has been used to assess bone fracture healing, prosthetic hip loosening and dental implant OI with varying degrees of success. More recently experimental vibration analysis has been used in TFOI. However further work is needed to assess the potential of the technique and fully characterise the femur-implant system. The overall aim of this study was to develop physical and computational models of the TFOI femur-implant system and use these models to investigate the feasibility of vibration analysis to detect the process of OI. Femur-implant physical models were developed and manufactured using synthetic materials to represent four key stages of OI development (identified from a physiological model), simulated using different interface conditions between the implant and femur. Experimental vibration analysis (modal analysis) was then conducted using the physical models. The femur-implant models, representing stage one to stage four of OI development, were excited and the modal parameters obtained over the range 0-5kHz. The results indicated the technique had limited capability in distinguishing between different interface conditions. The fundamental bending mode did not alter with interfacial changes. However higher modes were able to track chronological changes in interface condition by the change in natural frequency, although no one modal parameter could uniquely distinguish between each interface condition. The importance of the model boundary condition (how the model is constrained) was the key finding; variations in the boundary condition altered the modal parameters obtained. Therefore the boundary conditions need to be held constant between tests in order for the detected modal parameter changes to be attributed to interface condition changes. A three dimensional Finite Element (FE) model of the femur-implant model was then developed and used to explore the sensitivity of the modal parameters to more subtle interfacial and boundary condition changes. The FE model was created using the synthetic femur geometry and an approximation of the implant geometry. The natural frequencies of the FE model were found to match the experimental frequencies within 20% and the FE and experimental mode shapes were similar. Therefore the FE model was shown to successfully capture the dynamic response of the physical system. As was found with the experimental modal analysis, the fundamental bending mode of the FE model did not alter due to changes in interface elastic modulus. Axial and torsional modes were identified by the FE model that were not detected experimentally; the torsional mode exhibited the largest frequency change due to interfacial changes (103% between the lower and upper limits of the interface modulus range). Therefore the FE model provided additional information on the dynamic response of the system and was complementary to the experimental model. The small changes in natural frequency over a large range of interface region elastic moduli indicated the method may only be able to distinguish between early and late OI progression. The boundary conditions applied to the FE model influenced the modal parameters to a far greater extent than the interface condition variations. Therefore the FE model, as well as the experimental modal analysis, indicated that the boundary conditions need to be held constant between tests in order for the detected changes in modal parameters to be attributed to interface condition changes alone. The results of this study suggest that in a clinical setting it is unlikely that the in vivo boundary conditions of the amputated femur could be adequately controlled or replicated over time and consequently it is unlikely that any longitudinal change in frequency detected by the modal analysis technique could be attributed exclusively to changes at the femur-implant interface. Therefore further development of the modal analysis technique would require significant consideration of the clinical boundary conditions and investigation of modes other than the bending modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reviews the literature on the outcome of flapless surgery for dental implants in the posterior maxilla. The literature search was carried out in using the keywords: flapless, dental implants and maxilla. A hand search and Medline search were carried out on studies published between 1971 and 2011. The authors included research involving a minimum of 15 dental implants with a followup period of 1 year, an outcome measurement of implant survival, but excluded studies involving multiple simultaneous interventions, and studies with missing data. The Cochrane approach for cohort studies and Oxford Centre for Evidence- Based Medicine were applied. Of the 56 published papers selected, 14 papers on the flapless technique showed high overall implant survival rates. The prospective studies yielded 97.01% (95% CI: 90.72–99.0) while retrospective studies or case series illustrated 95.08% (95% CI: 91.0–97.93) survival. The average of intraoperative complications was 6.55% using the flapless procedure. The limited data obtained showed that flapless surgery in posterior maxilla areas could be a viable and predictable treatment method for implant placement. Flapless surgery tends to be more applicable in this area of the mouth. Further long-term clinical controlled studies are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to identify retrospectively the predictors of implant survival when the flapless protocol was used in two private dental practices. Materials and Methods: The collected data were initially computer searched to identify the patients; later, a hand search of patient records was carried out to identify all flapless implants consecutively inserted over the last 10 years. The demographic information gathered on statistical predictors included age, sex, periodontal and peri-implantitis status, smoking, details of implants inserted, implant locations, placement time after extraction, use of simultaneous guided hard and soft tissue regeneration procedures, loading protocols, type of prosthesis, and treatment outcomes (implant survival and complications). Excluded were any implants that required flaps or simultaneous guided hard and soft tissue regeneration procedures, and implants narrower than 3.25 mm. Results: A total of 1,241 implants had been placed in 472 patients. Life table analysis indicated cumulative 5-year and 10-year implant survival rates of 97.9% and 96.5%, respectively. Most of the failed implants occurred in the posterior maxilla (54%) in type 4 bone (74.0%), and 55.0% of failed implants had been placed in smokers. Conclusion: Flapless dental implant surgery can yield an implant survival rate comparable to that reported in other studies using traditional flap techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone-anchored prostheses, relying on implants to attach the prosthesis directly to the residual skeleton, are the ultimate resort for patients with transfemoral amputations (TFA) experiencing severe socket discomfort. The first patient receiving a bone-anchored prosthesis underwent the surgery in 1990 in the Sahlgrenska University Hospital (Sweden). To date, there are two commercially available implants: OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany). The key to success to this technique is a firm bone-implant bonding, depending on increasing mechanical stress applied daily during load bearing exercises (LBE). The loading data could be analysed through different biomechanical variables. The intra-tester reliability of these exercises will be presented here. Moreover the effect of increase of loading, axes of application of the load and body weight as well as the difference between force and moment variables will be discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The creep behaviour of a creep-resistant AE42 magnesium alloy reinforced with Saffil short fibres and SiC particulates in various combinations has been investigated in the transverse direction, i.e., the plane containing random fibre orientation was perpendicular to the loading direction, in the temperature range of 175-300 degrees C at the stress levels ranging from 60 to 140 MPa using impression creep test technique. Normal creep behaviour, i.e., strain rate decreasing with strain and then reaching a steady state, is observed at 175 degrees C at all the stresses employed, and up to 80 MPa stress at 240 degrees C. A reverse creep behaviour, i.e., strain rate increasing with strain, then reaching a steady state and then decreasing, is observed above 80 MPa stress at 240 degrees C and at all the stress levels at 300 degrees C. This pattern remains the same for all the composites employed. The reverse creep behaviour is found to be associated with fibre breakage. The apparent stress exponent is found to be very high for all the composites. However, after taking the threshold stress into account, the true stress exponent is found to range between 4 and 7, which suggests viscous glide and dislocation climb being the dominant creep mechanisms. The apparent activation energy Q(C) was not calculated due to insufficient data at any stress level either for normal or reverse creep behaviour. The creep resistance of the hybrid composites is found to be comparable to that of the composite reinforced with 20% Saffil short fibres alone at all the temperatures and stress levels investigated. The creep rate of the composites in the transverse direction is found to be higher than the creep rate in the longitudinal direction reported in a previous paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding technology evolution through periodic landscaping is an important stage of strategic planning in R&D Management. In fields like that of healthcare, where the initial R&D investment is huge and good medical product serve patients better, these activities become crucial. Approximately five percentage of the world population has hearing disabilities. Current hearing aid products meet less than ten percent of the global needs. Patent data and classifications on cochlear implants from 1977-2010, show the landscapes and evolution in the area of such implant. We attempt to highlight emergence and disappearance of patent classes over period of time showing variations in cochlear implant technologies. A network analysis technique is used to explore and capture technology evolution in patent classes showing what emerged or disappeared over time. Dominant classes are identified. The sporadic influence of university research in cochlear implants is also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During service and/or storage, Sn-Ag-Cu (SAC) solder alloys are subjected to temperatures ranging from 0.4 to 0.8 Tm (where Tm is the melting temperature of SAC alloys), making them highly prone to significant microstructural coarsening. The microstructures of these low melting point alloys continuously evolve during service. This results in evolution of creep properties of the joint over time, thereby influencing the long-term reliability of microelectronic packages. Here, we study microstructure evolution and creep behavior of two Sn-Ag-Cu (SAC) alloys, namely Sn-3.0Ag-0.5Cu and Sn-1.0Cu-0.5Cu, isothermally aged at 150 degrees C for various lengths of time. Creep behavior of the two SAC solders after different aging durations was systematically studied using impression creep technique. The key microstructural features that evolve during aging are Ag3Sn particle size and inter-particle spacing. Creep results indicate that the creep rate increases considerably with increasing inter-particle spacing although the creep stress exponent and creep activation energy are independent of the aging history.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Elastomer Visible Implant system (EVI) is a relatively new technique for batch marking fish. The aim of this study was to assess retention rates and the possible effects of tagging on the growth and mortality of barbel, Barbus barbus, (81-197mm, fork length) over approximately 2 months using a syringe injection system.