966 resultados para half-frequency bunching method
Resumo:
Mode of access: Internet.
Resumo:
Background: Reliability or validity studies are important for the evaluation of measurement error in dietary assessment methods. An approach to validation known as the method of triads uses triangulation techniques to calculate the validity coefficient of a food-frequency questionnaire (FFQ). Objective: To assess the validity of an FFQ estimates of carotenoid and vitamin E intake against serum biomarker measurements and weighed food records (WFRs), by applying the method of triads. Design: The study population was a sub-sample of adult participants in a randomised controlled trial of beta-carotene and sunscreen in the prevention of skin cancer. Dietary intake was assessed by a self-administered FFQ and a WFR. Nonfasting blood samples were collected and plasma analysed for five carotenoids (alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein, lycopene) and vitamin E. Correlation coefficients were calculated between each of the dietary methods and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficients were estimated using bootstrap sampling. Results: The validity coefficients of the FFQ were highest for alpha-carotene (0.85) and lycopene (0.62), followed by beta- carotene (0.55) and total carotenoids (0.55), while the lowest validity coefficient was for lutein (0.19). The method of triads could not be used for b- cryptoxanthin and vitamin E, as one of the three underlying correlations was negative. Conclusions: Results were similar to other studies of validity using biomarkers and the method of triads. For many dietary factors, the upper limit of the validity coefficients was less than 0.5 and therefore only strong relationships between dietary exposure and disease will be detected.
Resumo:
A numerical method is introduced to determine the nuclear magnetic resonance frequency of a donor (P-31) doped inside a silicon substrate under the influence of an applied electric field. This phosphorus donor has been suggested for operation as a qubit for the realization of a solid-state scalable quantum computer. The operation of the qubit is achieved by a combination of the rotation of the phosphorus nuclear spin through a globally applied magnetic field and the selection of the phosphorus nucleus through a locally applied electric field. To realize the selection function, it is required to know the relationship between the applied electric field and the change of the nuclear magnetic resonance frequency of phosphorus. In this study, based on the wave functions obtained by the effective-mass theory, we introduce an empirical correction factor to the wave functions at the donor nucleus. Using the corrected wave functions, we formulate a first-order perturbation theory for the perturbed system under the influence of an electric field. In order to calculate the potential distributions inside the silicon and the silicon dioxide layers due to the applied electric field, we use the multilayered Green's functions and solve an integral equation by the moment method. This enables us to consider more realistic, arbitrary shape, and three-dimensional qubit structures. With the calculation of the potential distributions, we have investigated the effects of the thicknesses of silicon and silicon dioxide layers, the relative position of the donor, and the applied electric field on the nuclear magnetic resonance frequency of the donor.
Resumo:
We have proposed a similarity matching method (SMM) to obtain the change of Brillouin frequency shift (BFS), in which the change of BFS can be determined from the frequency difference between detecting spectrum and selected reference spectrum by comparing their similarity. We have also compared three similarity measures in the simulation, which has shown that the correlation coefficient is more accurate to determine the change of BFS. Compared with the other methods of determining the change of BFS, the SMM is more suitable for complex Brillouin spectrum profiles. More precise result and much faster processing speed have been verified in our simulation and experiments. The experimental results have shown that the measurement uncertainty of the BFS has been improved to 0.72 MHz by using the SMM, which is almost one-third of that by using the curve fitting method, and the speed of deriving the BFS change by the SMM is 120 times faster than that by the curve fitting method.
Resumo:
The L-moments based index-flood procedure had been successfully applied for Regional Flood Frequency Analysis (RFFA) for the Island of Newfoundland in 2002 using data up to 1998. This thesis, however, considered both Labrador and the Island of Newfoundland using the L-Moments index-flood method with flood data up to 2013. For Labrador, the homogeneity test showed that Labrador can be treated as a single homogeneous region and the generalized extreme value (GEV) was found to be more robust than any other frequency distributions. The drainage area (DA) is the only significant variable for estimating the index-flood at ungauged sites in Labrador. In previous studies, the Island of Newfoundland has been considered as four homogeneous regions (A,B,C and D) as well as two Water Survey of Canada's Y and Z sub-regions. Homogeneous regions based on Y and Z was found to provide more accurate quantile estimates than those based on four homogeneous regions. Goodness-of-fit test results showed that the generalized extreme value (GEV) distribution is most suitable for the sub-regions; however, the three-parameter lognormal (LN3) gave a better performance in terms of robustness. The best fitting regional frequency distribution from 2002 has now been updated with the latest flood data, but quantile estimates with the new data were not very different from the previous study. Overall, in terms of quantile estimation, in both Labrador and the Island of Newfoundland, the index-flood procedure based on L-moments is highly recommended as it provided consistent and more accurate result than other techniques such as the regression on quantile technique that is currently used by the government.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Carrying out information about the microstructure and stress behaviour of ferromagnetic steels, magnetic Barkhausen noise (MBN) has been used as a basis for effective non-destructive testing methods, opening new areas in industrial applications. One of the factors that determines the quality and reliability of the MBN analysis is the way information is extracted from the signal. Commonly, simple scalar parameters are used to characterize the information content, such as amplitude maxima and signal root mean square. This paper presents a new approach based on the time-frequency analysis. The experimental test case relates the use of MBN signals to characterize hardness gradients in a AISI4140 steel. To that purpose different time-frequency (TFR) and time-scale (TSR) representations such as the spectrogram, the Wigner-Ville distribution, the Capongram, the ARgram obtained from an AutoRegressive model, the scalogram, and the Mellingram obtained from a Mellin transform are assessed. It is shown that, due to nonstationary characteristics of the MBN, TFRs can provide a rich and new panorama of these signals. Extraction techniques of some time-frequency parameters are used to allow a diagnostic process. Comparison with results obtained by the classical method highlights the improvement on the diagnosis provided by the method proposed.
Resumo:
Aims. In an earlier paper we introduced a new method for determining asteroid families where families were identified in the proper frequency domain (n, g, g + s) ( where n is the mean-motion, and g and s are the secular frequencies of the longitude of pericenter and nodes, respectively), rather than in the proper element domain (a, e, sin(i)) (semi-major axis, eccentricity, and inclination). Here we improve our techniques for reliably identifying members of families that interact with nonlinear secular resonances of argument other than g or g + s and for asteroids near or in mean-motion resonant configurations. Methods. We introduce several new distance metrics in the frequency space optimal for determining the diffusion in secular resonances of argument 2g - s, 3g - s, g - s, s, and 2s. We also regularize the dependence of the g frequency as a function of the n frequency (Vesta family) or of the eccentricity e (Hansa family). Results. Our new approaches allow us to recognize as family members objects that were lost with previous methods, while keeping the advantages of the Carruba & Michtchenko (2007, A& A, 475, 1145) approach. More important, an analysis in the frequency domain permits a deeper understanding of the dynamical evolution of asteroid families not always obtainable with an analysis in the proper element domain.
Resumo:
We use the density functional theory/local-density approximation (DFT/LDA)-1/2 method [L. G. Ferreira , Phys. Rev. B 78, 125116 (2008)], which attempts to fix the electron self-energy deficiency of DFT/LDA by half-ionizing the whole Bloch band of the crystal, to calculate the band offsets of two Si/SiO(2) interface models. Our results are similar to those obtained with a ""state-of-the-art"" GW approach [R. Shaltaf , Phys. Rev. Lett. 100, 186401 (2008)], with the advantage of being as computationally inexpensive as the usual DFT/LDA. Our band gap and band offset predictions are in excellent agreement with experiments.
Resumo:
This paper presents a novel graphical approach to adjust and evaluate frequency-based relays employed in anti-islanding protection schemes of distributed synchronous generators, in order to meet the anti-islanding and abnormal frequency variation requirements, simultaneously. The proposed method defines a region in the power mismatch space, inside which the relay non-detection zone should be located, if the above-mentioned requirements must be met. Such region is called power imbalance application region. Results show that this method can help protection engineers to adjust frequency-based relays to improve the anti-islanding capability and to minimize false operation occurrences, keeping the abnormal frequency variation utility requirements satisfied. Moreover, the proposed method can be employed to coordinate different types of frequency-based relays, aiming at improving overall performance of the distributed generator frequency protection scheme. (C) 2011 Elsevier B.V. All rights reserved.