766 resultados para fire setting
Resumo:
Gypsum plasterboards are commonly used as a fire safety material in the building industry. Many research studies have been undertaken to investigate the thermal behaviour of plasterboards under standard fire conditions. However, there are many discrepancies in relation to the basic thermal properties of plasterboards while simple equations are not available to predict the ambient surface time–temperature profiles of gypsum plasterboard panels that can be used in simulating the behaviour and strength of steel studs or joists in load bearing LSF wall and floor systems. In this research, suitable thermal properties of plasterboards were proposed based on a series of tests and available results from past research. Finite element models of gypsum plasterboard panels were then developed to simulate their thermal behaviour under standard fire conditions. The accuracy of the proposed thermal properties and the finite element models was validated by comparing the numerical results with available fire test results of plasterboard panels. This paper presents the details of the finite element models of plasterboard panels, the thermal analysis results from finite element analyses under standard fire conditions and their comparisons with experimental results
Resumo:
Purpose – While there have been numerous studies on the antecedents and consequences of service quality, there has been little investigation of the moderators of service quality. The purpose of this study is to demonstrate the effects of two moderators: service convenience and the social servicescape. The moderating effects are tested in two service settings: retail and hedonic (concert). Design/methodology/approach – A survey of 270 customers at kitchen display showrooms and 320 concert-goers was undertaken. The results were analysed using regression analysis. Findings – The results show support for ten of the 12 hypotheses. Service convenience moderated the relationships between perceived service quality and its three sub-dimensions (interaction, environment, and outcome quality), differently in different settings (retail vs hedonic). This supports the authors' general argument that the outcome dimension tends to be more important to customers in a retail setting, while interaction and environment quality dimensions tend to be more important in hedonic service consumption. Practical implications – These findings suggest that managers need to use different service management tactics in retail and hedonic service settings. Specifically managers in retail settings need to pay more attention to service convenience to achieve service quality and managers in hedonic settings should concentrate on the social servicescape. Originality/value – This paper is the first to test the moderating factors of service convenience and social servicescape on service quality.
Resumo:
Gypsum plasterboards are commonly used to protect the light gauge steel-framed walls in buildings from fires. Single or multiple plasterboards can be used for this purpose, whereas recent research has proposed a composite panel with a layer of external insulation between two plasterboards. However, a good understanding of the thermal behaviour of these plasterboard panels under fire conditions is not known. Therefore, 15 small-scale fire tests were conducted on plasterboard panels made of 13 and 16 mm plasterboards and four different types of insulations with varying thickness and density subject to standard fire conditions in AS 1530.4. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effects of interfaces between adjacent plasterboards. Effects of using external insulations such as glass fibre, rockwool and cellulose fibre were also determined. The thermal performance of composite panels developed from different insulating materials of varying densities and thicknesses was examined and compared. This paper presents the details of the fire tests conducted in this study and their valuable time–temperature data for the tested plasterboard panels. These data can be used for the purpose of developing and validating accurate thermal numerical models of these panels.
Resumo:
In the twenty-first century, Australian musicians increasingly maintain ‘portfolio’ careers, in which they combine diverse employment arrangements and activities. Often, these incorporate industry sectors outside of music. This career pattern is widespread but not well understood, largely because of the limitations of existing research. The lack of knowledge about musicians’ work and careers means that Australia currently may not provide appropriate and effective policy, funding, initial training and continuing career support across the diverse music sector. This article discusses existing research relating to the careers and skilling needs of musicians in Australia, and outlines a targeted agenda for further research that has the potential to inform stronger alignment between the requirements of building sustainable music careers and musicians’ education and training.
Resumo:
Background During a global influenza pandemic, the vaccine requirements of developing countries can surpass their supply capabilities, if these exist at all, compelling them to rely on developed countries for stocks that may not be available in time. There is thus a need for developing countries in general to produce their own pandemic and possibly seasonal influenza vaccines. Here we describe the development of a plant-based platform for producing influenza vaccines locally, in South Africa. Plant-produced influenza vaccine candidates are quicker to develop and potentially cheaper than egg-produced influenza vaccines, and their production can be rapidly upscaled. In this study, we investigated the feasibility of producing a vaccine to the highly pathogenic avian influenza A subtype H5N1 virus, the most generally virulent influenza virus identified to date. Two variants of the haemagglutinin (HA) surface glycoprotein gene were synthesised for optimum expression in plants: these were the full-length HA gene (H5) and a truncated form lacking the transmembrane domain (H5tr). The genes were cloned into a panel of Agrobacterium tumefaciens binary plant expression vectors in order to test HA accumulation in different cell compartments. The constructs were transiently expressed in tobacco by means of agroinfiltration. Stable transgenic tobacco plants were also generated to provide seed for stable storage of the material as a pre-pandemic strategy. Results For both transient and transgenic expression systems the highest accumulation of full-length H5 protein occurred in the apoplastic spaces, while the highest accumulation of H5tr was in the endoplasmic reticulum. The H5 proteins were produced at relatively high concentrations in both systems. Following partial purification, haemagglutination and haemagglutination inhibition tests indicated that the conformation of the plant-produced HA variants was correct and the proteins were functional. The immunisation of chickens and mice with the candidate vaccines elicited HA-specific antibody responses. Conclusions We managed, after synthesis of two versions of a single gene, to produce by transient and transgenic expression in plants, two variants of a highly pathogenic avian influenza virus HA protein which could have vaccine potential. This is a proof of principle of the potential of plant-produced influenza vaccines as a feasible pandemic response strategy for South Africa and other developing countries.
Resumo:
The transition process from student to Registered Nurse has been recognised as an important yet challenging time for newly graduated nurses. Knowledge about this experience from the nurse’s perspective, particularly in a rural setting, is limited. This paper reports the findings of a qualitative study of the experiences of newly graduated nurses working in a rural acute care facility in New South Wales. The study examined, from the perspective of the new nurse, the orientation and support which can help to facilitate the transition from student to registered nurse. Four themes emerged which were being supported, being challenged, reflections on being a new graduate, and reflections on a rural new graduate program. These findings contribute to what is know about the transition of new graduates in a rural facility and have implications for program improvements, specifically within the rural acute care environment. The findings are also relevant to students considering rural employment on graduation and for the recruitment and retention of New Graduate Registered Nurses in rural areas.
Resumo:
An iterative based strategy is proposed for finding the optimal rating and location of fixed and switched capacitors in distribution networks. The substation Load Tap Changer tap is also set during this procedure. A Modified Discrete Particle Swarm Optimization is employed in the proposed strategy. The objective function is composed of the distribution line loss cost and the capacitors investment cost. The line loss is calculated using estimation of the load duration curve to multiple levels. The constraints are the bus voltage and the feeder current which should be maintained within their standard range. For validation of the proposed method, two case studies are tested. The first case study is the semi-urban 37-bus distribution system which is connected at bus 2 of the Roy Billinton Test System which is located in the secondary side of a 33/11 kV distribution substation. The second case is a 33 kV distribution network based on the modification of the 18-bus IEEE distribution system. The results are compared with prior publications to illustrate the accuracy of the proposed strategy.
Resumo:
Background: End-of-life care is a significant component of work in intensive care. Limited research has been undertaken on the provision of end-of-life care by nurses in the intensive care setting. The purpose of this study was to explore the end-of-life care beliefs and practices of intensive care nurses. Methods: A descriptive exploratory qualitative research approach was used to invite a convenience sample of five intensive care nurses from one hospital to participate in a semi-structured interview. Interview transcripts were analysed using an inductive coding approach. Findings: Three major categories emerged from analysis of the interviews: beliefs about end-of-life care, end-of-life care in the intensive care context and facilitating end-of-life care. The first two categories incorporated factors contributing to the end-of-life care experiences and practices of intensive care nurses. The third category captured the nurses’ end-of-life care practices. Conclusions: Despite the uncertainty and ambiguity surrounding end-of-life care in this practice context, the intensive care setting presents unique opportunities for nurses to facilitate positive end-of-life experiences and nurses valued their participation in the provision of end-of-life care. Care of the family was at the core of nurses’ end-of-life care work and nurses play a pivotal role in supporting the patient and their family to have positive and meaningful experiences at the end-of-life.Variation in personal beliefs and organisational support may influence nurses’ experiences and the care provided to patients and their families. Strategies to promote an organisational culture supportive of quality end-of-life care practices, and to mentor and support nurses in the provision of this care are needed.
Resumo:
Little published information exists about the issues involved in conducting complex intravenous medication therapy in patients' homes. An ethnographic study of a local hospital-in-the-home program in the Australian Capital Territory explored this phenomenon to identify those factors that had an impact on the use of medicine in the home environment. This article focuses on one of the three themes identified in the study-Clinical Practice. Within this theme, topics related to the organization and management of intravenous medications, geography and diversity of patient caseload, and communication in the practice setting are discussed. These findings have important implications for policy development and establishment of a research agenda for hospital-in-the-home services.
Resumo:
We evaluated the Minnesota Multiphasic Personality Inventory-Second Edition (MMPI-2) Response Bias Scale (RBS). Archival data from 83 individuals who were referred for neuropsychological assessment with no formal diagnosis (n = 10), following a known or suspected traumatic brain injury (n = 36), with a psychiatric diagnosis (n = 20), or with a history of both trauma and a psychiatric condition (n = 17) were retrieved. The criteria for malingered neurocognitive dysfunction (MNCD) were applied, and two groups of participants were formed: poor effort (n = 15) and genuine responders (n = 68). Consistent with previous studies, the difference in scores between groups was greatest for the RBS (d = 2.44), followed by two established MMPI-2 validity scales, F (d = 0.25) and K (d = 0.23), and strong significant correlations were found between RBS and F (rs = .48) and RBS and K (r = −.41). When MNCD group membership was predicted using logistic regression, the RBS failed to add incrementally to F. In a separate regression to predict group membership, K added significantly to the RBS. Receiver-operating curve analysis revealed a nonsignificant area under the curve statistic, and at the ideal cutoff in this sample of >12, specificity was moderate (.79), sensitivity was low (.47), and positive and negative predictive power values at a 13% base rate were .25 and .91, respectively. Although the results of this study require replication because of a number of limitations, this study has made an important first attempt to report RBS classification accuracy statistics for predicting poor effort at a range of base rates.
Resumo:
Numerical study is carried out using large eddy simulation to study the heat and toxic gases released from fires in real road tunnels. Due to disasters about tunnel fires in previous decade, it attracts increasing attention of researchers to create safe and reliable ventilation designs. In this research, a real tunnel with 10 MW fire (which approximately equals to the heat output speed of a burning bus) at the middle of tunnel is simulated using FDS (Fire Dynamic Simulator) for different ventilation velocities. Carbone monoxide concentration and temperature vertical profiles are shown for various locations to explore the flow field. It is found that, with the increase of the longitudinal ventilation velocity, the vertical profile gradients of CO concentration and smoke temperature were shown to be both reduced. However, a relatively large longitudinal ventilation velocity leads to a high similarity between the vertical profile of CO volume concentration and that of temperature rise.
Resumo:
In the face of Australia’s disaster-prone environment, architects Ian Weir and James Davidson are reconceptualising how our residential buildings might become more resilient to fire, flood and cyclone. With their first-hand experience of natural disasters, James, director of Emergency Architects Australia (EAA), and Ian, one of Australia’s few ‘bushfire architects’, discuss the ways we can design with disaster in mind. Dr Ian Weir is one of Australia’s few ‘bushfire architects’. Exploring a holistic ‘ground up’ approach to bushfire where landscape, building design and habitation patterns are orchestrated to respond to site-specific fire characteristics. Ian’s research is developed through design studio teaching at QUT and through built works in Western Australia’s fire prone forests and heathlands.
Resumo:
Slow speed run-overs represent a major cause of injury and death among Australian children, with higher rates of incidents being reported in Queensland than in the remaining Australian states. Yet, little attention has been given to how caregivers develop their safety behaviour in and around the driveway setting. To address this gap, the current study aimed to develop a conceptual model of driveway child safety behaviours among caregivers of children aged five years or younger. Semi-structured interviews were conducted with 26 caregivers (25 females/1 male, mean age, 33.24 year) from rural and metropolitan Queensland. To enable a comparison and validation of findings from the driveway, the study analysed both driveway and domestic safety behaviours. Domestic safety behaviours were categorised and validated against driveway safety behaviours, uncovering a process of risk appraisal and safety behaviour that was applicable in both settings (the Safety System Model). However, noteworthy differences between the domestic and driveway setting were uncovered. Unlike in the domestic setting, driveway risks were perceived as shifting according the presence of moving vehicles, which resulted in inconsistent safety behaviours. While the findings require further validation, they have implications for the design and implementation of driveway run-over interventions.
Resumo:
In recent times, light gauge steel frame (LSF) wall systems are increasingly used in the building industry. They are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. A composite LSF wall panel system was developed recently, where an insulation layer was used externally between the two plasterboards to improve the fire performance of LSF wall panels. In this research, finite element thermal models of the new composite panels were developed using a finite element program, SAFIR, to simulate their thermal performance under both standard and Eurocode design fire curves. Suitable apparent thermal properties of both the gypsum plasterboard and insulation materials were proposed and used in the numerical models. The developed models were then validated by comparing their results with available standard fire test results of composite panels. This paper presents the details of the finite element models of composite panels, the thermal analysis results in the form of time-temperature profiles under standard and Eurocode design fire curves and their comparisons with fire test results. Effects of using rockwool, glass fibre and cellulose fibre insulations with varying thickness and density were also investigated, and the results are presented in this paper. The results show that the use of composite panels in LSF wall systems will improve their fire rating, and that Eurocode design fires are likely to cause severe damage to LSF walls than standard fires.