972 resultados para endotracheal tube cuff pressure
Resumo:
STUDY OBJECTIVE To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.
Resumo:
ABSTRACT The authors describe two animals (one dog and one cat) that were presented with severe respiratory distress after trauma. Computerized tomographic imaging under general anesthesia revealed, in both cases, complete tracheal transection. Hypoxic episodes during anesthesia were relieved by keeping the endotracheal tube (ETT) positioned in the cranial part of the transected trachea and by allowing spontaneous breathing. Surgical preparation was performed quickly, and patients were kept in a sternal position to improve ventilation and oxygenation, and were only turned into dorsal recumbency shortly before surgical incision. A sterile ETT was guided into the distal part of the transected trachea by the surgeon, at which point mechanical ventilation was started. Both animals were successfully discharged from hospital a few days after surgery. Rapid and well-coordinated teamwork seemed to contribute to the good outcome. Precise planning and communication between anesthetists, surgeons, and technicians, as well as a quick course of action prior to correct ETT positioning helped to overcome critical phases.
Resumo:
Aim. To describe the subsequent treatment of airway trauma sustained during laryngoscopy and endotracheal intubation. Methods. A rare injury occurring during laryngoscopy and endotracheal intubation that resulted in perforation of the tongue by an endotracheal tube and the subsequent management of this unusual complication are discussed. A 65-year-old female with intraparenchymal brain hemorrhage with rapidly progressive neurologic deterioration had the airway secured prior to arrival at the referral institution. The endotracheal tube (ETT) was noted to have pierced through the base of the tongue and entered the trachea, and the patient underwent operative laryngoscopy to inspect the injury and the ETT was replaced by tracheostomy. Results. Laryngoscopy demonstrated the ETT to perforate the base of the tongue. The airway was secured with tracheostomy and the ETT was removed. Conclusions. A wide variety of complications resulting from direct and video-assisted laryngoscopy and tracheal intubation have been reported. Direct perforation of the tongue with an ETT and ability to ventilate and oxygenate subsequently is a rare injury.
Resumo:
We investigated the effect of pneumatic pressure applied to the proximal musculature of the sheep foreleg on load at the site of a transverse osteotomy of the distal radius. The distal radii of 10 fresh sheep foreleg specimens were osteotomized and a pressure sensor was inserted between the two bone fragments. An inflatable cuff, connected to a second pressure sensor, was positioned around the proximal forelimb musculature and the leg then was immobilized in a plaster cast. The inflatable cuff was inflated and deflated repeatedly to various pressures. Measurements of the cuff pressure and corresponding change in pressure at the osteotomy site were recorded. The results indicated that application of pneumatic pressure to the proximal foreleg musculature produced a corresponding increase in load at the osteotomy site. For the cuff pressures tested (109.8-238.4 mm Hg), there was a linear correlation with the load at the osteotomy site with a gradient of 12 mm Hg/N. It is conceivable, based on the results of this study, that a technique could be developed to provide dynamic loading to accelerate fracture healing in the upper limb of humans.
Resumo:
Background. Previous studies have identified no strong correlation between patients' height and tracheal length in anaesthetized patients. We have attempted to compare vocal cords-carina distance (VCD) in Chinese patients with the dimensions of five commonly used tracheal tubes. In addition, we attempted to find a surface anatomy measurement that would identify patients with 'short tracheas'. Methods. We measured VCD in 130 anaesthetized Chinese patients with a fibreoptic bronchoscope. Also measurements were obtained of the distal ends of five commonly used tracheal tubes. We undertook various surface anatomy measurements on the patients' chest and neck region to predict those patients with short tracheas. Results. VCD averaged 12.6 ((SD) 1.4) cm. In seven patients (5%) this distance was particularly short (between 8.8 and 10.4 cm). Many of the commonly used tracheal tubes would be placed close to or beyond the carina when the black intubation guide mark(s) is (are) at the level of the vocal cords. The VCD of
Resumo:
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
Resumo:
Earlier version of an indigenously developed Pressure Wave Generator (PWG) could not develop the necessary pressure ratio to satisfactorily operate a pulse tube cooler, largely due to high blow by losses in the piston cylinder seal gap and due to a few design deficiencies. Effect of different parameters like seal gap, piston diameter, piston stroke, moving mass and the piston back volume on the performance is studied analytically. Modifications were done to the PWG based on analysis and the performance is experimentally measured. A significant improvement in PWG performance is seen as a result of the modifications. The improved PWG is tested with the same pulse tube cooler but with different inertance tube configurations. A no load temperature of 130 K is achieved with an inertance tube configuration designed using Sage software. The delivered PV power is estimated to be 28.4 W which can produce a refrigeration of about 1 W at 80 K.
Resumo:
A linear stability analysis is carried out for the flow through a tube with a soft wall in order to resolve the discrepancy of a factor of 10 for the transition Reynolds number between theoretical predictions in a cylindrical tube and the experiments of Verma and Kumaran J. Fluid Mech. 705, 322 (2012)]. Here the effect of tube deformation (due to the applied pressure difference) on the mean velocity profile and pressure gradient is incorporated in the stability analysis. The tube geometry and dimensions are reconstructed from experimental images, where it is found that there is an expansion and then a contraction of the tube in the streamwise direction. The mean velocity profiles at different downstream locations and the pressure gradient, determined using computational fluid dynamics, are found to be substantially modified by the tube deformation. The velocity profiles are then used in a linear stability analysis, where the growth rates of perturbations are calculated for the flow through a tube with the wall modeled as a neo-Hookean elastic solid. The linear stability analysis is carried out for the mean velocity profiles at different downstream locations using the parallel flow approximation. The analysis indicates that the flow first becomes unstable in the downstream converging section of the tube where the flow profile is more pluglike when compared to the parabolic flow in a cylindrical tube. The flow is stable in the upstream diverging section where the deformation is maximum. The prediction for the transition Reynolds number is in good agreement with experiments, indicating that the downstream tube convergence and the consequent modification in the mean velocity profile and pressure gradient could reduce the transition Reynolds number by an order of magnitude.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this article we present analytical and numerical results for a pressure profile along the axis of a tube with a general and arbitrary time- and position-dependent gas source. The model is able to determine the pressure values along the tube, once the pumping speed at each extremity and the gas sources are specified. The time evolution of the pressure along a tube is presented for situations commonly found in high-vacuum applications, such as particle accelerators, colliders, storage rings, and synchrotron light sources. (C) 2004 American Vacuum Society.
Resumo:
This work presents and describes in detail the pressure profile in a conical tube with the unavoidable steady-state outgassing, plus a transient gas source, like, for instance, in an accelerator, when particles from the beam hit the walls. Mathematical and physical formulations are given and detailed; specific conductance, specific throughput and a detailed discussion about the boundary conditions are presented. These concepts and approach are applied to usual realistic cases, such as conical tubes, with typical laboratory dimensions. © 2005 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)