Pressure field distribution in a conical tube with transient and outgassing gas sources
| Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
|---|---|
| Data(s) |
27/05/2014
27/05/2014
01/12/2005
|
| Resumo |
This work presents and describes in detail the pressure profile in a conical tube with the unavoidable steady-state outgassing, plus a transient gas source, like, for instance, in an accelerator, when particles from the beam hit the walls. Mathematical and physical formulations are given and detailed; specific conductance, specific throughput and a detailed discussion about the boundary conditions are presented. These concepts and approach are applied to usual realistic cases, such as conical tubes, with typical laboratory dimensions. © 2005 IEEE. |
| Formato |
2422-2424 |
| Identificador |
http://dx.doi.org/10.1109/PAC.2005.1591132 Proceedings of the IEEE Particle Accelerator Conference, v. 2005, p. 2422-2424. http://hdl.handle.net/11449/68538 10.1109/PAC.2005.1591132 WOS:000235745201308 2-s2.0-33847123633 |
| Idioma(s) |
eng |
| Relação |
Proceedings of the IEEE Particle Accelerator Conference |
| Direitos |
closedAccess |
| Palavras-Chave | #Boundary conditions #Degassing #Throughput #Conical tube #Pressure field distribution #Steady-state outgassing #Particle accelerators |
| Tipo |
info:eu-repo/semantics/conferencePaper |