927 resultados para emergent protocols


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabajo parte de la inquietud de cómo organizar y articular los recursos diplomáticos, económicos, tecnológicos y culturales que cuenta la Argentina en África, para incentivar e incrementar las vinculaciones entre ambas regiones. Teniendo en cuenta los nuevos escenarios emergentes del espacio africano y los lineamientos de política exterior ensayados por nuestro país en los últimos años, nuestro período de análisis se concentrará entre los años 2002 y 2007. Sostenemos que el desarrollo de una estrategia articulada y permanente hacia el África requiere un aprovechamiento más eficaz y eficiente de los recursos humanos, financieros y tecnológicos existentes. De esto modo, la Argentina podría posicionarse como un socio relevante en la agenda de los países africanos, proveyendo productos, tecnología y servicios a mercados complementarios y en expansión. El objetivo general del proyecto es reconocer las transformaciones recientes del diseño exterior argentino hacia los mercados emergentes, en particular hacia África.El abordaje de esta investigación tiene características tanto cualitativas como cuantitativas, al tiempo que pretende alcanzar un nivel de explicación debido al tipo de propuesta. Nuestras unidades de observación son aquellas instituciones y personalidades vinculadas a la elaboración e implementación de la política exterior de Argentina hacia los estados africanos en su conjunto (tanto de África Subsahariana como de África del Norte). En cuanto a las técnicas aplicadas se pueden reconocer diversas fases. En primera instancia se llevará adelante una exploración documental en la Cancillería argentina destinada a cubrir los principales lineamientos respecto al tema. Luego se revisarán documentos producidos por organismos privados y por investigadores científicos. Al mismo tiempo se realizarán entrevistas semiestructuradas a los actores claves que participaron en el proceso de toma de decisiones.Con este trabajo nos proponemos concretar un manual que contenga de forma sistemática las normativas y las prácticas que ejercen cada uno de los actores, tanto públicos como privados, en torno a las vinculaciones entre Argentina y los países de África. Este ordenamiento nos permitirá ofrecer a los responsables de tomas de decisiones un marco articulado, accesible y didáctico para el diseño y la ejecución de futuras políticas hacia la región. Actualmente, los lazos políticos, culturales y de cooperación entre los países de ambas regiones manifiestan un creciente dinamismo, poniendo en juego nuevos terrenos de colaboración como las Cumbres América del Sur-África, las reuniones inter-ministeriales, la firma de acuerdos de comercio entre el Mercosur y algunos estados africanos, entre otros. Sin embargo a pesar de estas señales auspiciosas, los mercados africanos no han sido explorados con la suficiente constancia y profundidad. El desarrollo de este proyecto permitirá, en primer lugar, constituir un corpus de información sobre las normativas y las prácticas en torno los vínculos argentino-africanos. Por otro lado, será una herramienta indispensable para la planificación y concreción de futuras políticas en torno al área. Cabe aclarar que no se limita a organismos del Estado sino también involucraría a actores privados implicados o interesados con los mercados emergentes africanos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is dedicated to comparison of open source as well as proprietary transport protocols for highspeed data transmission via IP networks. The contemporary common TCP needs significant improvement since it was developed as general-purpose transport protocol and firstly introduced four decades ago. In nowadays networks, TCP fits not all communication needs that society has. Caused of it another transport protocols have been developed and successfully used for e.g. Big Data movement. In scope of this research the following protocols have been investigated for its efficiency on 10Gbps links: UDT, RBUDP, MTP and RWTP. The protocols were tested under different impairments such as Round Trip Time up to 400 ms and packet losses up to 2%. Investigated parameters are the data rate under different conditions of the network, the CPU load by sender andreceiver during the experiments, size of feedback data, CPU usage per Gbps and the amount of feedback data per GiByte of effectively transmitted data. The best performance and fair resources consumption was observed by RWTP. From the opensource projects, the best behavior is showed by RBUDP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Laboratori Europeu de Física de Partícules (CERN), Suissa, entre maig i setembre del 2006. L’estada al laboratori CERN ha tingut dues vessants complementàries, les dues relacionades amb la imminent posada en marxa de l'experiment LHCb a finals del 2007, quan l'accelerador LHC comenci a funcionar. D'una banda, s’ha treballat en la integració del subdetector SPD en LHCb, i de l'altra al desenvolupament dels algorismes de trigger de LHCb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the planning of subgroup analyses in protocols of randomised controlled trials and the agreement with corresponding full journal publications. DESIGN: Cohort of protocols of randomised controlled trial and subsequent full journal publications. SETTING: Six research ethics committees in Switzerland, Germany, and Canada. DATA SOURCES: 894 protocols of randomised controlled trial involving patients approved by participating research ethics committees between 2000 and 2003 and 515 subsequent full journal publications. RESULTS: Of 894 protocols of randomised controlled trials, 252 (28.2%) included one or more planned subgroup analyses. Of those, 17 (6.7%) provided a clear hypothesis for at least one subgroup analysis, 10 (4.0%) anticipated the direction of a subgroup effect, and 87 (34.5%) planned a statistical test for interaction. Industry sponsored trials more often planned subgroup analyses compared with investigator sponsored trials (195/551 (35.4%) v 57/343 (16.6%), P<0.001). Of 515 identified journal publications, 246 (47.8%) reported at least one subgroup analysis. In 81 (32.9%) of the 246 publications reporting subgroup analyses, authors stated that subgroup analyses were prespecified, but this was not supported by 28 (34.6%) corresponding protocols. In 86 publications, authors claimed a subgroup effect, but only 36 (41.9%) corresponding protocols reported a planned subgroup analysis. CONCLUSIONS: Subgroup analyses are insufficiently described in the protocols of randomised controlled trials submitted to research ethics committees, and investigators rarely specify the anticipated direction of subgroup effects. More than one third of statements in publications of randomised controlled trials about subgroup prespecification had no documentation in the corresponding protocols. Definitive judgments regarding credibility of claimed subgroup effects are not possible without access to protocols and analysis plans of randomised controlled trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancer development is a long-term multistep process which allows interventional measure before the clincial disease emerges. the detection of natural substances which can block the process of carcinogenesis is a important as the identification of anti-tumoral drugs since they might be used in chemoprevention of cancer in high-risk groups. In vivo rodent models of chemical caecinogenesis have been used to study plant-derived inhibitors of carcinofenesis such as indols, coumarins, isothiocyanates, flavones, phenols and allyl-sulfides. Since the standard in vivo rodent bioassay is prolonged and expensive, shorter reliable protocols are needed. Two in vivo medium-term protocols for evaluation of modifiers of carcinogenesis are presented, one related to liver and the other to bladder cancer. Both protocols use rats, last 8 and 36 weeks and are based on the two-step concept of carcinogenesis: initiation and promotion. The protocols use respectively the development of altered foci of hepatocytes expressing immunochistochemically the placental form of gluthation S-transferase and the appearence of pre-neoplastic urothelium and papillomas as the "end-points". the use of these protocols for detection of plantpderived inhibitors of carcinogenesis appear warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the period from 1987 to 1998, 13 cases of human sporotrichosis were recorded at the Research Center Evandro Chagas Hospital (CPqHEC) in Rio de Janeiro. Two of these patients related scratch by a sick cat. During the subsequent period from July 1998 to July 2000, 66 human, 117 cats and 7 dogs with sporotrichosis were diagnosed at the CPqHEC. Fifty-two humans (78.8%) reported contact with cats with sporotrichosis, and 31 (47%) of them reporting a history of a scratch or bite. This epidemic, unprecedented in the literature, involving cats, dogs and human beings may have started insidiously before 1998.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eosinophilic meningitis (EoM) is an acute disease that affects the central nervous system. It is primarily caused by infection with the nematode Angiostrongylus cantonensis. This infection was previously restricted to certain Asian countries and the Pacific Islands, but it was first reported in Brazil in 2007. Since then, intermediate and definitive hosts infected with A. cantonensis have been identified within the urban areas of many states in Brazil, including those in the northern, northeastern, southeastern and southern regions. The goals of this review are to draw the attention of the medical community and health centres to the emergence of EoM in Brazil, to compile information about several aspects of the human infection and mode of transmission and to provide a short protocol of procedures for the diagnosis of this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tomodensitométrie (CT) est une technique d'imagerie dont l'intérêt n'a cessé de croître depuis son apparition dans le début des années 70. Dans le domaine médical, son utilisation est incontournable à tel point que ce système d'imagerie pourrait être amené à devenir victime de son succès si son impact au niveau de l'exposition de la population ne fait pas l'objet d'une attention particulière. Bien évidemment, l'augmentation du nombre d'examens CT a permis d'améliorer la prise en charge des patients ou a rendu certaines procédures moins invasives. Toutefois, pour assurer que le compromis risque - bénéfice soit toujours en faveur du patient, il est nécessaire d'éviter de délivrer des doses non utiles au diagnostic.¦Si cette action est importante chez l'adulte elle doit être une priorité lorsque les examens se font chez l'enfant, en particulier lorsque l'on suit des pathologies qui nécessitent plusieurs examens CT au cours de la vie du patient. En effet, les enfants et jeunes adultes sont plus radiosensibles. De plus, leur espérance de vie étant supérieure à celle de l'adulte, ils présentent un risque accru de développer un cancer radio-induit dont la phase de latence peut être supérieure à vingt ans. Partant du principe que chaque examen radiologique est justifié, il devient dès lors nécessaire d'optimiser les protocoles d'acquisitions pour s'assurer que le patient ne soit pas irradié inutilement. L'avancée technologique au niveau du CT est très rapide et depuis 2009, de nouvelles techniques de reconstructions d'images, dites itératives, ont été introduites afin de réduire la dose et améliorer la qualité d'image.¦Le présent travail a pour objectif de déterminer le potentiel des reconstructions itératives statistiques pour réduire au minimum les doses délivrées lors d'examens CT chez l'enfant et le jeune adulte tout en conservant une qualité d'image permettant le diagnostic, ceci afin de proposer des protocoles optimisés.¦L'optimisation d'un protocole d'examen CT nécessite de pouvoir évaluer la dose délivrée et la qualité d'image utile au diagnostic. Alors que la dose est estimée au moyen d'indices CT (CTDIV0| et DLP), ce travail a la particularité d'utiliser deux approches radicalement différentes pour évaluer la qualité d'image. La première approche dite « physique », se base sur le calcul de métriques physiques (SD, MTF, NPS, etc.) mesurées dans des conditions bien définies, le plus souvent sur fantômes. Bien que cette démarche soit limitée car elle n'intègre pas la perception des radiologues, elle permet de caractériser de manière rapide et simple certaines propriétés d'une image. La seconde approche, dite « clinique », est basée sur l'évaluation de structures anatomiques (critères diagnostiques) présentes sur les images de patients. Des radiologues, impliqués dans l'étape d'évaluation, doivent qualifier la qualité des structures d'un point de vue diagnostique en utilisant une échelle de notation simple. Cette approche, lourde à mettre en place, a l'avantage d'être proche du travail du radiologue et peut être considérée comme méthode de référence.¦Parmi les principaux résultats de ce travail, il a été montré que les algorithmes itératifs statistiques étudiés en clinique (ASIR?, VEO?) ont un important potentiel pour réduire la dose au CT (jusqu'à-90%). Cependant, par leur fonctionnement, ils modifient l'apparence de l'image en entraînant un changement de texture qui pourrait affecter la qualité du diagnostic. En comparant les résultats fournis par les approches « clinique » et « physique », il a été montré que ce changement de texture se traduit par une modification du spectre fréquentiel du bruit dont l'analyse permet d'anticiper ou d'éviter une perte diagnostique. Ce travail montre également que l'intégration de ces nouvelles techniques de reconstruction en clinique ne peut se faire de manière simple sur la base de protocoles utilisant des reconstructions classiques. Les conclusions de ce travail ainsi que les outils développés pourront également guider de futures études dans le domaine de la qualité d'image, comme par exemple, l'analyse de textures ou la modélisation d'observateurs pour le CT.¦-¦Computed tomography (CT) is an imaging technique in which interest has been growing since it first began to be used in the early 1970s. In the clinical environment, this imaging system has emerged as the gold standard modality because of its high sensitivity in producing accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase of the number of CT examinations performed has raised concerns about the potential negative effects of ionizing radiation on the population. To insure a benefit - risk that works in favor of a patient, it is important to balance image quality and dose in order to avoid unnecessary patient exposure.¦If this balance is important for adults, it should be an absolute priority for children undergoing CT examinations, especially for patients suffering from diseases requiring several follow-up examinations over the patient's lifetime. Indeed, children and young adults are more sensitive to ionizing radiation and have an extended life span in comparison to adults. For this population, the risk of developing cancer, whose latency period exceeds 20 years, is significantly higher than for adults. Assuming that each patient examination is justified, it then becomes a priority to optimize CT acquisition protocols in order to minimize the delivered dose to the patient. Over the past few years, CT advances have been developing at a rapid pace. Since 2009, new iterative image reconstruction techniques, called statistical iterative reconstructions, have been introduced in order to decrease patient exposure and improve image quality.¦The goal of the present work was to determine the potential of statistical iterative reconstructions to reduce dose as much as possible without compromising image quality and maintain diagnosis of children and young adult examinations.¦The optimization step requires the evaluation of the delivered dose and image quality useful to perform diagnosis. While the dose is estimated using CT indices (CTDIV0| and DLP), the particularity of this research was to use two radically different approaches to evaluate image quality. The first approach, called the "physical approach", computed physical metrics (SD, MTF, NPS, etc.) measured on phantoms in well-known conditions. Although this technique has some limitations because it does not take radiologist perspective into account, it enables the physical characterization of image properties in a simple and timely way. The second approach, called the "clinical approach", was based on the evaluation of anatomical structures (diagnostic criteria) present on patient images. Radiologists, involved in the assessment step, were asked to score image quality of structures for diagnostic purposes using a simple rating scale. This approach is relatively complicated to implement and also time-consuming. Nevertheless, it has the advantage of being very close to the practice of radiologists and is considered as a reference method.¦Primarily, this work revealed that the statistical iterative reconstructions studied in clinic (ASIR? and VECO have a strong potential to reduce CT dose (up to -90%). However, by their mechanisms, they lead to a modification of the image appearance with a change in image texture which may then effect the quality of the diagnosis. By comparing the results of the "clinical" and "physical" approach, it was showed that a change in texture is related to a modification of the noise spectrum bandwidth. The NPS analysis makes possible to anticipate or avoid a decrease in image quality. This project demonstrated that integrating these new statistical iterative reconstruction techniques can be complex and cannot be made on the basis of protocols using conventional reconstructions. The conclusions of this work and the image quality tools developed will be able to guide future studies in the field of image quality as texture analysis or model observers dedicated to CT.