332 resultados para electrocardiogram


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Twenty-seven healthy captive lions (Panthera leo) and 13 healthy captive tigers (Panthera tigris) from S to Paulo Zoo (Fundacao Parque Zoologico de Rio Paulo, Sao Paulo, Brazil) collection were selected for this study. They were anesthetized with ketamine (10 mg/kg) combined with xylazine (1-2 mg/kg) for physical examinations. hematologic and serum chemical analysis and electrocardiogram recording. The main aim of this research was to gather initial information about normal electrocardiographic parameters of large felids. Standard P-QRS-T deflections on leads described for domestic carnivores were analyzed, and they did not greatly differ from those of large felids. taking into account the greater weight and corporal mass of large felids. Heart rate of lions ranged frorn 42 to 76 beats per minute (bpm). Heart rate of tigers ranged from 56 to 97 bpm. In both species, the most common rhythm detected was normal sinus rhythm followed by sinus arrhythmia: wandering, pacemaker was also observed with normal sinus rhythm or sinus arrhythmia. Mean electrical axis lay between +60 degrees and +120 degrees. QRS complexes were predominantly positive in leads DI, DII, DIII, and AVF and negative in AVR and AVL. This Study provides insights into normal electrocardiograms of large felids. Wider investigations on the same subject arc necessary to establish criteria for the recognition of abnormalities in these species and should include other anesthetic drug(s) combinations and reports of electrocardiographic features of animals with cardiac disease and electrolytes disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been limited investigation of parturition in the bitch and there is little information published on clinical and obstetrical examination other than opinion and anecdote. While there are substantial data on haemodynamic and vascular changes during normal parturition in humans, little is known about the physiological events in the dog. This study was aimed at maternal haemodynamic changes occurring during normal parturition and to investigate how these were modified in bitches with dystocia (DYST) treated either medically or via assisted delivery and caesarean operation. Three groups of 10 bitches were investigated; those with normal parturition, those with DYST corrected by manipulative assistance or caesarean operation and those with uterine inertia treated by oxytocin administration. Heart rate, systolic and diastolic blood pressure, electrocardiogram and blood glucose concentration were measured pre-partum, intra-partum, immediately after parturition and 1 h later. Heart rate was high at all times throughout the study and the majority of bitches had normal sinus rhythm. Blood pressure was generally within the normal range, and although systolic and diastolic blood pressure was highest during the intra-partum period and sometimes during the immediate post-partum period, there were no significant differences between groups. All bitches had blood glucose concentrations within the normal range throughout the study although pre-partum concentrations were statistically lower than many of the other time periods. The study provides useful physiological data that will facilitate monitoring and clinical management of bitches throughout normal parturition and DYST.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to analyze electrocardiographic alterations during dental implant surgeries when local anesthetic agents were used. Materials and Methods: Twenty implants were placed in 18 healthy patients. An electrocardiogram and Wincardio software were used to gather recordings from 12 static leads every 2 minutes, continuously record coronary artery (D2) derivations, and automatically measure the following electrocardiographic parameters: heart rate, duration and amplitude of the P wave, PR segment duration, ST segment deviation, QRS complex duration, and duration of the RR, QT, and corrected QT (QTc) intervals. Results: Analysis of variance of the values obtained at the different stages showed significant differences (P < .05) for the heart rate and for the duration of the RR and QT intervals. The heart rate increased during the anesthesia, incision, and bone drilling stages, reaching a peak during drilling. Duration of the RR and QT intervals decreased during the incision and drilling stages. Among the electrocardiographic parameters individually assessed, several altered values were found for the duration of the P wave, the QRS complex, and the QT and QTc intervals. Sinusal tachycardia and bradycardia, sinusal arrhythmia, supraventricular extrasystole, ventricular extrasystole, and T-wave inversion were detected. Conclusion: Dental implant placement surgery may induce electrocardiographic alterations. The most frequently found arrhythmias were extrasystole and sinusal tachycardia. The anesthesia, incision, and bone drilling stages exhibited the highest heart rate values and the shortest durations of the RR and QT intervals. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:412-418

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Measurement and improvement of quality of care is a priority issue in health care. Patients hospitalized with acute coronary syndromes (ACS) constitute a high-risk population whose care, if shown to be suboptimal on the basis of available research evidence, may benefit from quality improvement interventions. Aim: To evaluate the quality of in-hospital care for patients with ACS, using explicit quality indicators. Methods: Retrospective case note review was undertaken of 397 patients admitted to three teaching hospitals in Brisbane, Queensland, Australia, between 1 October 2000 and 17 April 2001. The main out-come measures were 12 process-of-care quality indicators, calculated as either: (i) the proportion of all patients who received specific interventions or (ii) the proportion of ideal patients who received -specific interventions (i.e. patients with clear indi-cations and lacking contraindications). Results: Quality indicators with values above 80% included: (i) patient selection for thrombolysis (100%) and discharge prescription of beta-blockers (84%), (ii) antiplatelet agents (94%) and (iii) lipid-lowering agents (82%). Indicators with values between 50% and 80% included: (i) timely per-formance of electrocardiogram (ECG) on admission (61%), (ii) early coronary angiography (75%), (iii) measurement of serum lipids (71%) and (iv) discharge prescription of angiotensin-converting-enzyme (ACE) inhibitors (73%). Indicators with values <50% included: (i) timely administration of thrombolysis (35%), (ii) non-invasive risk assessment (23%) and (ii) formal in-hospital and post-hospital cardiac rehabilitation (47% and 7%, respectively). Conclusion: There were delays in performing ECG and administering thrombolysis to patients who presented to emergency departments with ACS. Improvement is warranted in use of non-invasive procedures for identifying high-risk patients who may benefit from coronary revascularization as well as use of serum lipid measurements, ACE inhibitors and cardiac rehabilitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In modern magnetic resonance imaging (MRI), patients are exposed to strong, time-varying gradient magnetic fields that may be able to induce electric fields (E-fields)/currents in tissues approaching the level of physiological significance. In this work we present theoretical investigations into induced E-fields in the thorax, and evaluate their potential influence on cardiac electric activity under the assumption that the sites of maximum E-field correspond to the myocardial stimulation threshold (an abnormal circumstance). Whole-body cylindrical and planar gradient coils were included in the model. The calculations of the induced fields are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, whole-body model. The potential for cardiac stimulation was evaluated using an electrical model of the heart. Twelve-lead electrocardiogram (ECG) signals were simulated and inspected for arrhythmias caused by the applied fields for both healthy and diseased hearts. The simulations show that the shape of the thorax and the conductive paths significantly influence induced E-fields. In healthy patients, these fields are not sufficient to elicit serious arrhythmias with the use of contemporary gradient sets. However, raising the strength and number of repeated switching episodes of gradients, as is certainly possible in local chest gradient sets, could expose patients to increased risk. For patients with cardiac disease, the risk factors are elevated. By the use of this model, the sensitivity of cardiac pathologies, such as abnormal conductive pathways, to the induced fields generated by an MRI sequence can be investigated. (C) 2003 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks,and are valid to other scenarios and environments rather than hospitals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One hundred and twenty subjects with Chagas' cardiopathy and 120 non-infected subjects were randomly selected from first time claimants of sickness benefits in the National Institute of Social Security (INPS) in Goiás. Cases of Chagas' cardiopathy were defined based on serological test, history of residence in an endemic area and, clinical and/or electrocardiogram (ECG) alterations suggestive of Chagas' cardiomyopathy. Controls were defined as subjects with at least two negative serological tests. Case and controls were compared in the analysis for age, sex, place of birth, migration history, socio-economic level, occupation, physical exertion at work, age at affiliation and years of contribution to the social security scheme, clinical course of their disease and ECG abnormalities. Chagas' disease patients were younger than other subjects and predominantly of rural origin. Non-infected subjects presented a better socio-economic level, were performing more skilled activities and had less changes of job than cases. No important difference was observed in relation to age at affiliation to INPS. About 60% of cases have claimed for benefits within the first four years of contribution while among controls this proportion was 38.5%. Cases were involved, proportionally more than controls, in "heavy" activities. A risk of 2.3 (95%CL 1.5 - 4.6) and 1.8 (95%CL 1.2- 3.5) was obtained comparing respectively "heavy" and "moderate" physical activity against "light". A relative risk of 8.5 (95%CL 4.9 - 14.8) associated with the presence of cardiopathy was estimated comparing the initial sample of seropositive subjects and controls. A high relative risk was observed in relation to right bundle branch block (RR = 37.1 95%CL = 8.8 - 155.6) and left anterior hemiblock (RR = 4.4, 95%CL = 2.1 - 9.1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A cohort study has been designed to identify predictors of adverse health events in the elderly. The methodology of the study and preliminary descriptive results are presented. METHODS: The study population comprises all residents of Bambuí (Minas Gerais, Brazil), aged 60 or more years (n=1.742). From these, 92.2% were interviewed and 85.9% underwent clinical examination, consisting of haematological and biochemical tests, serology for Trypanosoma cruzi, anthropometric and blood pressure measures and electrocardiogram. Aliquots of serum, plasma and DNA were stored for future investigations. The baseline interview included sociodemographic characteristics, self-referred health condition and history of selected diseases, medication use, health service use, source of medical care, physical activities, smoking, drinking and eating habits, reproductive history, physical functioning, life events, social support and mental health. Individuals are being followed up annually. RESULTS: The following characteristics predominated among participants: women (60,0%), married (48.9%) or widowed (35.4%), people living in households with up to 2 residents (73.8%), heads of family (76.7%), people with monthly income between 1.00 and 2.99 Brazilian minimum wages (62.0%) and people with up to 4 years of schooling (89.1%). The median age was 68 years. Among the cohort members, only 1.7% were lost in the first follow-up. CONCLUSIONS: In general, the characteristics of the study population were very similar to those from other epidemiological studies of the elderly based on large Brazilian cities. The small number of losses to follow-up indicates that the choice of Bambuí was adequate, assuring the feasibility of a long term cohort study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prevalence and clinical forms of Trypanosoma cruzi were evaluated among blood donor candidates attended at a general hospital in Rio de Janeiro, Brazil, from January 1997 to April 1999. The investigation was done by means of the indirect hemagglutination test and was confirmed via ELISA. Data were collected from clinical examinations, conventional electrocardiogram, chest radiography and echocar-diography. The results showed that despite Trypanosoma cruzi prevalence of 1.17% (128 patients), mainly in males aged 40 years or over, 70.8% of these patients, mainly males aged 19 to 39 years, demonstrated abnormalities that allowed the diagnosis of cardiopathy and/or esophagopathy. This once again corroborates the importance of Trypanosoma cruzi infection in urban centers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores – Ramo Automação e Sistemas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação propõe o desenvolvimento de um sistema capaz de adquirir e monitorizar num computador o sinal do electrocardiograma (ECG) e de detectar o pico R do complexo QRS do referido sinal. Numa primeira fase foi efectuado um estudo do sistema cardiovascular, de forma a compreender a actividade eléctrica do coração e dos diversos sinais que constituem o ECG. Foi efectuado um estudo sobre o sinal ECG, tendo sido estudadas as suas características, bem como técnicas e componentes básicos de aquisição e condicionamento do sinal, sendo também analisados diversos sistemas que efectuam a aquisição de ECG. Numa segunda fase foram estudadas as Field Programmable Analog Array (FPAA), analisando o estado da arte desta tecnologia, bem como os dispositivos disponíveis comercialmente. Após esta análise foram seleccionados os dispositivos FPAA, bem como o restante hardware e software necessários para a realização desta Tese. Foi desenvolvido um sistema de condicionamento de sinal ECG, e de detecção de pico R do complexo QRS, apenas com componentes analógicos discretos tendo sido analisados os resultados obtidos antes de se avançar para a fase seguinte. Após a realização do sistema com componentes discretos, foi implementado um sistema em que grande parte do condicionamento do sinal ECG é efectuado por duas placas de desenvolvimento FPAA, de forma a diminuir a quantidade de componentes e a obter um sinal com melhor resolução. Os resultados obtidos foram analisados e comparados com o sistema desenvolvido. Para monitorizar o sinal ECG e o pico R num computador, foi desenvolvido um sistema em que os sinais são convertidos pelo conversor A/D de um microcontrolador, e enviados por comunicação série para um computador, sendo os valores obtidos visualizados numa aplicação em ambiente MATLAB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Gestão e Avaliação de Tecnologias em Saúde.