476 resultados para dwellings


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reaction of nine vector species of Chagas' disease to infection by seven different Trypanosoma cruzi strains; Berenice, Y, FL, CL, S. Felipe, Colombiana and Gávea, are examined and compared. On the basis of the insects' ability to establish and maintain the infection, vector species could be divided into two distinct groups which differ in their reaction to an acute infection by T. cruzi. While the proportion of positive bugs was found to be low in Triatoma infestans and Triatoma dimidiata it was high, ranging from 96.9% to 100% in the group of wild (Rhodnius neglectus, Triatoma rubrovaria)and essentially sylvatic vectors in process of adaptation to human dwellings, maintained under control following successful insecticidal elimination of Triatoma infestans (Panstrongylus megistus, Triatoma sordida and Triatoma pseudomaculata). An intermediate position is held by Triatoma brasiliensis and Rhodnius prolixus. This latter has been found to interchange between domestic and sylvatic environments. The most important finding is the strikingly good reaction between each species of the sylvatic bugs and practically all T. cruzi strains herein studied, thus indicating that the factors responsible for the excellent reaction of P.megistus to infection by Y strain, as previously reported also come into operation in the reaction of the same vector species to acute infections by five of the remaining T.cruzi strains. Comparison or data reported by other investigators with those herein described form the basis of the discussion of Dipetalogaster maximus as regards its superiority as a xenodiagnostic agent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study of Spissipes Section of Culex (Melanoconion) adults behaviour was carried out from August 1992 through December 1993 in human dominated (anthropic) environment in the Ribeira Valley, S.Paulo State, Brazil. By sampling at several sites it the dominance of Culex ribeirensis and Cx. sacchettae became evident even through a total number of ten species was recorded. Those two mosquitoes showed a clear tendency to frequent the domiciliary environment where they were caught, both indoor and outdoor, through the use of the human bait. In the outside environments, the residual patchy forests seems to display a concentration role, from which these adults spread to the open land and reach the dwellings. As their vector competence has been demonstrated through the virus isolations in natural conditions, it is advisable to pay attention to the presence of these mosquitoes in the man-made environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A survey of adult behaviour of Culex (Culex) species was carried out from August 1992 through December 1993 in a human modified (anthropic) environment in the Ribeira Valley, S.Paulo State, Brazil. Culex nigripalpus dominated the catches at several sites and it's tendency to increase in the anthropic environment became quite clear. Nevertheless no high level of synanthropy was demonstrated. So it seems that the mosquito may have a restricted role in natural arbovirus cycles. Nonetheless, Cx. nigripalpus must be considered a potential vector of arboviruses, especially St. Louis encephalitis virus outside dwellings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório de estágio, que se realizou no Edifício Atrium Saldanha em Lisboa, tem por finalidade demonstrar as aptidões adquiridas no decorrer do Mestrado e que tornaram possíveis a participação num estágio que envolveu várias áreas da Engenharia Mecânica. Nos últimos anos, tem-se assistido a um crescente aumento do consumo e do custo da energia eléctrica. De acordo com análises realizadas pela União Europeia, uma percentagem significativa deste aumento de consumo está relacionado com edifícios e habitações. A manutenção preventiva das instalações técnicas é, entre outros aspectos, uma das ferramentas essenciais na redução desta factura energética. A questão que se coloca relaciona-se com a metodologia a aplicar para esse efeito. De que forma podem ou devem os planos de manutenção ser elaborados, qual a periodicidade das intervenções a considerar de modo a aumentar a eficiência energética dos edifícios, reduzir as emissões de dióxido de carbono e garantir uma maior protecção do utilizador? Numa fase inicial do estágio foi feita uma caracterização geral das principais instalações técnicas do edifício de modo a se analisarem, posteriormente, os procedimentos de manutenção adoptados pelas equipas de manutenção. Foram ainda sugeridas algumas periodicidades para os procedimentos de manutenção já existentes e algumas intervenções que não estavam incluídas no plano de manutenção do edifício e que podem contribuir para aumentar a fiabilidade dos equipamentos e consequentemente a eficiência energética e a qualidade do ar interior dos edifícios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estudo, de natureza qualitativa e exploratório, teve como objectivo verificar se a cidade do Porto possui características de uma cidade amiga das pessoas idosas, na perspectiva de idosos residentes neste meio urbano. Uma cidade amiga das pessoas idosas estimula um envelhecimento activo e com dignidade ao optimizar oportunidades para a saúde, participação e segurança. Foram realizados dois focus groups com pessoas idosas habitantes das Freguesias da Vitória e Miragaia, seleccionados a partir de uma amostragem por conveniência, recorrendo-se a um guião de entrevista constituído pelas seguintes categorias: espaços exteriores e edifícios; transportes; habitação; respeito e inclusão social; participação social; participação cívica e emprego; comunicação e informação; apoio comunitário e serviços de saúde. Desta forma, foi possível verificar que, apesar dos participantes identificarem um conjunto de condições que podem ser consideradas amigas das pessoas idosas, a maior parte das características referidas foram encaradas como negativas e com um impacto considerável no seu quotidiano. A participação social, os meios de informação disponíveis e os serviços comunitários são as condições perante as quais os participantes demonstram maior satisfação. Pelo contrário, em relação aos espaços exteriores, referem aspectos, como os grandes declives, as más condições dos pavimentos, os obstáculos nos passeios e a acumulação de lixo, que contribuem para um ambiente desagradável e inseguro. Quanto aos transportes, as modificações na identificação dos veículos, as alterações nos percursos, a pouca consciencialização dos motoristas em relação às necessidades dos mais velhos e as condições das paragens são os principais factores destacados, enquanto as habitações são consideradas antigas e com más condições estruturais e de acesso. De uma forma geral, estes idosos consideram-se pouco reconhecidos e desrespeitados pelos mais jovens e deparam-se com grandes dificuldades no acesso a actividades laborais e de voluntariado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Vulcanologia e Riscos Geológicos, 25 de Novembro de 2013, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper seeks to investigate the effectiveness of sea-defense structures in preventing/reducing the tsunami overtopping as well as evaluating the resulting tsunami impact at El Jadida, Morocco. Different tsunami wave conditions are generated by considering various earthquake scenarios of magnitudes ranging from M-w = 8.0 to M-w = 8.6. These scenarios represent the main active earthquake faults in the SW Iberia margin and are consistent with two past events that generated tsunamis along the Atlantic coast of Morocco. The behavior of incident tsunami waves when interacting with coastal infrastructures is analyzed on the basis of numerical simulations of near-shore tsunami waves' propagation. Tsunami impact at the affected site is assessed through computing inundation and current velocity using a high-resolution digital terrain model that incorporates bathymetric, topographic and coastal structures data. Results, in terms of near-shore tsunami propagation snapshots, waves' interaction with coastal barriers, and spatial distributions of flow depths and speeds, are presented and discussed in light of what was observed during the 2011 Tohoku-oki tsunami. Predicted results show different levels of impact that different tsunami wave conditions could generate in the region. Existing coastal barriers around the El Jadida harbour succeeded in reflecting relatively small waves generated by some scenarios, but failed in preventing the overtopping caused by waves from others. Considering the scenario highly impacting the El Jadida coast, significant inundations are computed at the sandy beach and unprotected areas. The modeled dramatic tsunami impact in the region shows the need for additional tsunami standards not only for sea-defense structures but also for the coastal dwellings and houses to provide potential in-place evacuation.