992 resultados para cumulative peak area


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The incorporation of carboxyl functionalised multi-walled carbon nanotube (MWCNT-COOH) into a leading proprietary grade orthopaedic bone cement (Simplex PTM) at 0.1 wt% has been investigated. Resultant static and fatigue mechanical properties, in addition to thermal and polymerisation properties, have been determined. Significant improvements (p 0.001) in bending strength (42%), bending modulus (55%) and fracture toughness (22%) were demonstrated. Fatigue properties were improved (p 0.001), with mean number of cycles to failure and fatigue performance index being increased by 64% and 52%, respectively. Thermal necrosis index values at 44C and 55C were significantly reduced (p 0.001) (28% and 27%) versus the control. Furthermore, the onset of polymerisation increased by 58% (p < 0.001), as did the duration of the polymerisation reaction (52%). Peak energy during polymerisation increased by 672% (p < 0.001). Peak area of polymerisation increased by 116% (p < 0.001) indicating that the incorporation of MWCNT-COOH reduced the rate of polymerisation significantly. A non-significant reduction (8%) in percentage monomer conversion was also recorded. Raman spectroscopy clearly showed that the addition of MWCNT-COOH increased the ratio between normalised intensities of the G-Band and D-Band (IG/ID), and also increased the theoretical compressive strain (1.72%) exerted on the MWCNT-COOH by the Simplex PTM cement matrix. Therefore, demonstrating a level of chemical interactivity between the MWCNT-COOH and the Simplex PTM bone cement exists and consequently a more effective mechanism for successful transfer of mechanical load. The extent of homogenous dispersion of the MWCNT-COOH throughout the bone cement was determined using Raman mapping. Ke

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For more than a decade scientists tried to develop methods capable of dating ink by monitoring the loss of phenoxyethanol (PE) over time. While many methods were proposed in the literature, few were really used to solve practical cases and they still raise much concern within the scientific community. In fact, due to the complexity of ink drying processes it is particularly difficult to find a reliable ageing parameter to reproducibly follow ink ageing. Moreover, systematic experiments are required in order to evaluate how different factors actually influence the results over time. Therefore, this work aimed at evaluating the capacity of four different ageing parameters to reliably follow ink ageing over time: (1) the quantity of solvent PE in an ink line, (2) the relative peak area (RPA) normalising the PE results using stable volatile compounds present in the ink formulation, (3) the solvent loss ratio (R%) calculated from PE results obtained by the analyses of naturally and artificially aged samples, (4) a modified solvent loss ratio version (R%*) calculated from RPA results. After the determination of the limits of reliable measurements of the analytical method, the repeatability of the different ageing parameters was evaluated over time, as well as the influence of ink composition, writing pressure and storage conditions on the results. Surprisingly, our results showed that R% was not the most reliable parameter, as it showed the highest standard deviation. Discussion of the results in an ink dating perspective suggests that other proposed parameters, such as RPA values, may be more adequate to follow ink ageing over time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Factors involved in the determination of PAHs (16 priority PAHs as an example) and PCBs (10 PCB congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent studied included dichloromethane, acetonitrile, hexan e, cyclohexane, isooctane, octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex optimization method. Under the optimized conditions, both peak height and peak area of 16 PAHs, especially the late-eluting PAHs, were significantly enhanced (1 to 500 times) by using relatively higher boiling point solvents such as p-xylene and nonane, compared with commonly used solvents like benzene and isooctane. With the improved sensitivity, detection limits of between 4.4 pg for naphthalene and 30.8 pg for benzo[g,h,i]perylene were obtained when p-xylene was used as an injection solvent. Effect of solvent on peak shape and peak intensity were found to be greatly dependent on temperature parameters, especially the initial temperature of the capillary column. The relationship between initial temperature and shape of peaks from 16 PAHs and 10 PCBs were studied and compared when toluene, p-xylene, isooctane, and nonane were used as injection solvents. If a too low initial temperature was used, fronting or split of peaks was observed. On the other hand, peak tailing occurred at a too high initial column temperature. The optimum initial temperature, at which both peak fronting and tailing were avoided and symmetrical peaks were obtained, depended on both solvents and the stationary phase of the column used. On a methyl silicone column, the alkane solvents provided wider optimum ranges of initial temperature than aromatic solvents did, for achieving well-shaped symmetrical GC peaks. On a 5% diphenyl: 1% vinyl: 94% dimethyl polysiloxane column, when the aromatic solvents were used, the optimum initial temperature ranges for solutes to form symmetrical peaks were improved to a similar degree as those when the alkanes were used as injection solvents. A mechanism, based on the properties of and possible interactions among the analyte, the injection solvent, and the stationary phase of the capillary column, was proposed to explain these observations. The effect of initial temperature on peak height and peak area of the 16 PAHs and the 10 PCBs was also studied. The optimum initial temperature was found to be dependent on the physical properties of the solvent used and the amount of the solvent injected. Generally, from the boiling point of the solvent to 10 0C above its boiling point was an optimum range of initial temperature at which cthe highest peak height and peak area were obtained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La fumée du tabac est un aérosol extrêmement complexe constitué de milliers de composés répartis entre la phase particulaire et la phase vapeur. Il a été démontré que les effets toxicologiques de cette fumée sont associés aux composés appartenant aux deux phases. Plusieurs composés biologiquement actifs ont été identifiés dans la fumée du tabac; cependant, il n’y a pas d’études démontrant la relation entre les réponses biologiques obtenues via les tests in vitro ou in vivo et les composés présents dans la fumée entière du tabac. Le but de la présente recherche est de développer des méthodes fiables et robustes de fractionnement de la fumée à l’aide de techniques de séparation analytique et de techniques de détection combinés à des essais in vitro toxicologiques. Une étude antérieure réalisée par nos collaborateurs a démontré que, suite à l’étude des produits de combustion de douze principaux composés du tabac, l’acide chlorogénique s’est avéré être le composé le plus cytotoxique selon les test in vitro du micronoyau. Ainsi, dans cette étude, une méthode par chromatographie préparative en phase liquide a été développée dans le but de fractionner les produits de combustion de l’acide chlorogénique. Les fractions des produits de combustion de l’acide chlorogénique ont ensuite été testées et les composés responsables de la toxicité de l’acide chlorogénique ont été identifiés. Le composé de la sous-fraction responsable en majeure partie de la cytoxicité a été identifié comme étant le catéchol, lequel fut confirmé par chromatographie en phase liquide/ spectrométrie de masse à temps de vol. Des études récentes ont démontré les effets toxicologiques de la fumée entière du tabac et l’implication spécifique de la phase vapeur. C’est pourquoi notre travail a ensuite été focalisé principalement à l’analyse de la fumée entière. La machine à fumer Borgwaldt RM20S® utilisée avec les chambres d’exposition cellulaire de British American Tobacco permettent l’étude in vitro de l’exposition de cellules à différentes concentrations de fumée entière du tabac. Les essais biologiques in vitro ont un degré élevé de variabilité, ainsi, il faut prendre en compte toutes les autres sources de variabilité pour évaluer avec précision la finalité toxicologique de ces essais; toutefois, la fiabilité de la génération de la fumée de la machine n’a jamais été évaluée jusqu’à maintenant. Nous avons donc déterminé la fiabilité de la génération et de la dilution (RSD entre 0,7 et 12 %) de la fumée en quantifiant la présence de deux gaz de référence (le CH4 par détection à ionisation de flamme et le CO par absorption infrarouge) et d’un composé de la phase particulaire, le solanesol (par chromatographie en phase liquide à haute performance). Ensuite, la relation entre la dose et la dilution des composés de la phase vapeur retrouvée dans la chambre d’exposition cellulaire a été caractérisée en utilisant une nouvelle technique d’extraction dite par HSSE (Headspace Stir Bar Sorptive Extraction) couplée à la chromatographie en phase liquide/ spectrométrie de masse. La répétabilité de la méthode a donné une valeur de RSD se situant entre 10 et 13 % pour cinq des composés de référence identifiés dans la phase vapeur de la fumée de cigarette. La réponse offrant la surface maximale d’aire sous la courbe a été obtenue en utilisant les conditions expérimentales suivantes : intervalle de temps d’exposition/ désorption de 10 0.5 min, température de désorption de 200°C pour 2 min et température de concentration cryogénique (cryofocussing) de -75°C. La précision de la dilution de la fumée est linéaire et est fonction de l’abondance des analytes ainsi que de la concentration (RSD de 6,2 à 17,2 %) avec des quantités de 6 à 450 ng pour les composés de référence. Ces résultats démontrent que la machine à fumer Borgwaldt RM20S® est un outil fiable pour générer et acheminer de façon répétitive et linéaire la fumée de cigarette aux cultures cellulaires in vitro. Notre approche consiste en l’élaboration d’une méthodologie permettant de travailler avec un composé unique du tabac, pouvant être appliqué à des échantillons plus complexes par la suite ; ex : la phase vapeur de la fumée de cigarette. La méthodologie ainsi développée peut potentiellement servir de méthode de standardisation pour l’évaluation d’instruments ou de l’identification de produits dans l’industrie de tabac.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper reports changes in supraglacial debris cover and supra-/proglacial lake development associated with recent glacier retreat (1985-2000) in the central Caucasus Mountains, Russia. Satellite imagery (Landsat TM and ETM+) was used to map the surface area and supraglacial debris cover on six neighbouring glaciers in the Adylsu valley through a process of manual digitizing on a false-colour composite of bands 5, 4, 3 (red, green, blue). The distribution and surface area of supraglacial and proglacial lakes was digitized for a larger area, which extended to the whole Landsat scene. We also compare our satellite interpretations to field observations in the Adylsu valley. Supraglacial debris cover ranges from < 5% to > 25% on individual glaciers, but glacier retreat between 1985 and 2000 resulted in a 3-6% increase in the proportion of each glacier covered by debris. The only exception to this trend was a very small glacier where debris cover did not change significantly and remote mapping proved more difficult. The increase in debris cover is characterized by a progressive upglacier migration, which we suggest is being driven by focused ablation (and therefore glacier thinning) at the up-glacier limit of the debris cover, resulting in the progressive exposure of englacial debris. Glacier retreat has also been accompanied by an increase in the number of proglacial and supraglacial lakes in our study area, from 16 in 1985 to 24 in 2000, representing a 57% increase in their cumulative surface area. These lakes appear to be impounded by relatively recently lateral and terminal moraines and by debris deposits on the surface of the glacier. The changes in glacier surface characteristics reported here are likely to exert a profound influence on glacier mass balance and their future response to climate change. They may also increase the likelihood of glacier-related hazards (lake outbursts, debris slides), and future monitoring is recommended.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The leaves of the Thai vegetable, Teaw (Cratoxylum formosum Dyer) were extracted with ethanol to provide an extract that had antioxidant properties. The composition of the extract was studied by high-performance liquid chromatography with a diode array detector, and by electrospray ionization mass spectrometry. The main antioxidant component (peak 1) was chlorogenic acid, which was present at 60% of the extract. Three minor components were present at 7%, 3% and 2%, and other components that were present at lower concentrations were also observed. Treatment of the Teaw extract with 2,2-diphenyl-1-picrylhydrazyl radical (DPPH center dot) caused a similar reduction in peak area of 55.2-58.1% for chlorogenic acid and the three minor components, indicating that these components had common structural features. Component 2 was identified as dicaffeoylquinic acid, and compounds 3 and 4 were identified as ferulic acid derivatives. The radical-scavenging activity of the Teaw extract was compared with alpha-tocopherol, BHT and chlorogenic acid, using the DPPH center dot and 2,2'-azinobis (3-ethylbenzothialozinesulfonic acid) radical cation (ABTS(center dot+)) assays. The Teaw extract scavenged both free radicals more strongly than did a-tocopherol and BHT, and the activity of the extract was consistent with the concentration of chlorogenic acid that was present, confirming that this component is a major contributor to the antioxidant activity. The acute toxicity of the Teaw leaf extract was investigated in mice, and it was found that the LD50 of the extract was > 32 g/kg. Consequently, this plant is a promising source of a natural food antioxidant. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A recently developed capillary electrophoresis (CE)-negative-ionisation mass spectrometry (MS) method was used to profile anionic metabolites in a microbial-host co-metabolism study. Urine samples from rats receiving antibiotics (penicillin G and streptomycin sulfate) for 0, 4, or 8 days were analysed. A quality control sample was measured repeatedly to monitor the performance of the applied CE-MS method. After peak alignment, relative standard deviations (RSDs) for migration time of five representative compounds were below 0.4 %, whereas RSDs for peak area were 7.9–13.5 %. Using univariate and principal component analysis of obtained urinary metabolic profiles, groups of rats receiving different antibiotic treatment could be distinguished based on 17 discriminatory compounds, of which 15 were downregulated and 2 were upregulated upon treatment. Eleven compounds remained down- or upregulated after discontinuation of the antibiotics administration, whereas a recovery effect was observed for others. Based on accurate mass, nine compounds were putatively identified; these included the microbial-mammalian co-metabolites hippuric acid and indoxyl sulfate. Some discriminatory compounds were also observed by other analytical techniques, but CE-MS uniquely revealed ten metabolites modulated by antibiotic exposure, including aconitic acid and an oxocholic acid. This clearly demonstrates the added value of CE-MS for nontargeted profiling of small anionic metabolites in biological samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Successful coupling of electrochemical preconcentration (EPC) to capillary electrophoresis (CE) with contactless conductivity detection (C(4)D) is reported for the first time. The EPC-CE interface comprises a dual glassy carbon electrode (GCE) block, a spacer and an upper block with flow inlet and outlet, pseudo-reference electrode and a fitting for the CE silica column, consisting of an orifice perpendicular to the surface of a glassy carbon electrode with a bushing inside to ensure a tight press fit. The end of the capillary in contact with the GCE is slant polished, thus defining a reproducible distance from the electrode surface to the column bore. First results with EPC-CE-C(4)D are very promising, as revealed by enrichment factors of two orders of magnitude for Tl, Cu, Pb and Cd ion peak area signals. Detection limits for 10 min deposition time fall around 20 nmol L(-1) with linear calibration curves over a wide range. Besides preconcentration, easy matrix exchange between accumulation and stripping/injection favors procedures like sample cleanup and optimization of pH, ionic strength and complexing power. This was demonstrated for highly saline samples by using a low conductivity buffer for stripping/injection to improve separation and promote field-enhanced sample stacking during electromigration along the capillary. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction - A large number of natural and synthetic compounds having butenolides as a core unit have been described and many of them display a wide range of biological activities. Butenolides from P. malacophyllum have presented potential antifungal activities but no specific, fast, and precise method has been developed for their determination. Objective - To develop a methodology based on micellar electrokinetic chromatography to determine butenolides in Piper species. Methodology - The extracts were analysed in an uncoated fused-silica capillaries and for the micellar system 20 mmol/L SDS, 20% (v/v) acetonitrile (ACN) and 10 mmol/L STB aqueous buffer at pH 9.2 were used. The method was validated for precision, linearity, limit of detection (LOD) and limit of quantitation (LOQ) and the standard deviations were determined from the standard errors estimated by the regression line. Results - A micellar electrokinetic chromatography (MEKC) method for determination of butenolides in extracts gave full resolution for 1 and 2. The analytical curve in the range 10.0-50.0 mu g/mL (r(2) = 0.999) provided LOD and LOQ for 1 and 2 of 2.1/6.3 and 1.1/3.5 mu g/mL, respectively. The RSD for migration times were 0.12 and 1.0% for peak area ratios with 100.0 +/- 1.4% of recovery. Conclusions - A novel high-performance MEKC method developed for the analysis of butenolides 1 and 2 in leaf extracts of P. malacophyllum allowed their quantitative determined within an analysis time shorter than 5 min and the results indicated CE to be a feasible analytical technique for the quantitative determination of butenolides in Piper extracts. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, the separation of nine phenolic acids (benzoic, caffeic, chlorogenic, p-coumaric, ferulic, gallic, protocatechuic, syringic, and vanillic acid) was approached by a 32 factorial design in electrolytes consisting of sodium tetraborate buffer(STB) in the concentration range of 10-50 mmol L(-1) and methanol in the volume percentage of 5-20%. Derringer`s desirability functions combined globally were tested as response functions. An optimal electrolyte composed by 50 mmol L(-1) tetraborate buffer at pH 9.2, and 7.5% (v/v) methanol allowed baseline resolution of all phenolic acids under investigation in less than 15 min. In order to promote sample clean up, to preconcentrate the phenolic fraction and to release esterified phenolic acids from the fruit matrix, elaborate liquid-liquid extraction procedures followed by alkaline hydrolysis were performed. The proposed methodology was fully validated (linearity from 10.0 to 100 mu g mL(-1), R(2) > 0.999: LOD and LOQ from 1.32 to 3.80 mu g mL(-1) and from 4.01 to 11.5 mu g mL(-1), respectively; intra-day precision better than 2.8% CV for migration time and 5.4% CV for peak area; inter-day precision better than 4.8% CV for migration time and 4.8-11% CV for peak area: recoveries from 81% to 115%) and applied successfully to the evaluation of phenolic contents of abiu-roxo (Chrysophyllum caimito), wild mulberry growing in Brazil (Morus nigra L.) and tree tomato (Cyphomandra betacea). Values in the range of 1.50-47.3 mu g g(-1) were found, with smaller amounts occurring as free phenolic acids. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for the simultaneous determination of the stilbene resveratrol, four phenolic acids (syringic, coumaric, caffeic, and gallic acids), and five flavonoids (catechin, rutin, kaempferol, myricetin, and quercetin) in wine by CE was developed and validated. The CE electrolyte composition and instrumental conditions were optimized using 2(7-3) factorial design and response surface analysis, showing sodium tetraborate, MeOH, and their interaction as the most influential variables. The optimal electrophoretic conditions, minimizing the chromatographic resolution statistic values, consisted of 17 mmol/L sodium tetraborate with 20% methanol as electrolyte, constant voltage of 25 kV, hydrodynamic injection at 50 mbar for 3 s, and temperature of 25 degrees C. The R(2) values for linearity varied from 0.994 to 0.999; LOD and LOQ were 0.1 to 0.3 mg/L and 0.4 to 0.8 mg/L, respectively. The RSDs for migration time and peak area obtained from ten consecutive injections were less than 2% and recoveries varied from 97 to 102%. The method was applied to 23 samples of inexpensive Brazilian wines, showing wide compositional variation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reaction of tris(2,2’-bipyridyl)ruthenium(III) (Ru(bipy) 33+) with various analytes to generate chemiluminescence has been well documented. This investigation sought to undertake a chemiluminometic study of the reactions of Ru(bipy) 33+ with selected Papaver Somniferum alkaloids and specifically synthesised phenethylamines. The investigation, based on a kinetic study, primarily addressed the effect of varying reaction conditions (pH) on Ru(bipy) 33+ chemiluminescence production. To monitor these reactions, a batch chemiluminometer was specifically designed, fabricated and automated to conduct an extensive study on the selected compounds of interest. The instrumentation incorporated a custom built reaction cell and comprised an ‘on-line’ sample preparation system with which calibration standards could be automatically prepared. The instrumentation provided both time-independent (peak area) and time-dependent (kinetic profile) information. A novel approach to the stabilisation of Ru(bipy) 33+ as a chemiluminescencent reagent was also investigated and a recirculating system was employed with the batch chemiluminometer to provide a stable supply of Ru(bipy) 33+. Codeine, thebaine and 6-methoxy-codeine were the Papaver Somniferum alkaloids selected for this study and several N-methylated and N,N-dimethylated phenethylamines and methoxy-substituted phenetheylamines were also synthesised to investigate the affect of pH on the chemiluminescence emission efficiency. The versatility of the batch chemiluminometer facilitated the kinetic study of numerous analytes over a broad pH range. The exemplary performance of the chemiluminometer as an analytical instrument, was demonstrated by the calibration functions, based on peak area data, which exhibited excellent linearity and sensitivity. The estimated detection limits (3s) for the selected alkaloids were in the range 2 x 10-9 M to 7 x 10-9 at pH 5.0 and above, which compared favourably to detection limits for the same compounds determined using FIA. Relative standard deviations (n=5) for peak areas ranged between 1% to 5% with a mean of 3.1% for all calibration standards above 2.5 x 10-8 M. Correlation between concentration and peak area, irrespective of pH and analyte was excellent, with all but two calibration functions having r-squared values greater than 0.990. The analytical figures of merit exemplified the precision and robustness of the reagent delivery and ‘on-line’ sample preparation, as well as the sensitivity of the system. The employment of the chemiluminometer for the measurement of total chemiluminescence emission (peak area) was in itself a feasible analytical technique, which generated highly reproducible and consistent data. Excellent analytical figures of merit, based on peak area, were similarly achieved for the phenethylamines. The effects of analyte structure on chemiluminescence activity was also investigated for the alkaloids and the phenethylamines. Subtle structural variations between the three alkaloids resulted in either a moderately reduced or enhanced total emission that was two or three fold difference only. A significant difference in reaction kinetics was observed between thebaine and codeine/6-methoxy-codeine, which was dependent upon pH. The time-dependent data, namely the observed rate constants for the initial rise in intensity and for the subsequent decay rate, were obtained by fitting a mathematical function (based on the postulated reaction mechanism) to the raw data. The determination of these rate constants for chemiluminescence reactions highlighted the feasibility for utilising such measurements for quantitative analytical applications. The kinetic data were used to discriminate between analyte responses in order to determine the concentrations of individual analytes in a binary mixture. A preliminary, multi-component investigation performed on a binary mixture of codeine and 6-methoxy-codeine (1:1) successfully determined the concentrations of these individual components using such rate constant measurements. Consequently, variations in kinetics resulted in a significant difference between the relative chemiluminescence response based on peak area measurements and the relative response base on peak height measurements obtained using FIA. With regards to the observed reactivity of secondary amines and tertiary amines, chemiluminescence peak area determinations confirmed the vital role of pH on reaction efficiency, which was governed by structural features and kinetics. The tertiary amines investigated generally produced a greater emission under acidic conditions than the corresponding secondary amines. However, the measured chemiluminescence responses were highly dependent upon pH, with similar peak areas obtained for both amine groups under slightly alkaline conditions.