829 resultados para color difference


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The use of different light sources as an adjunct to in-office bleaching has been questioned. Thus, the aim of this study was to evaluate the color changes of teeth after application of bleaching techniques with different products, with and without activation by a LED-laser system. Methods: Twenty-four bovine teeth surfaces were submitted to three bleaching techniques with two commercially available 35% hydrogen peroxide bleaching agents (n=8). The specimens were immersed in red wine for 48 h at 37°C and submitted to the bleaching techniques. Color changes were measured before and after staining as well as immediately after and 24 h after the bleaching treatments, with two different methods of color evaluation, software ScanWhite V1.1 and intra-oral spectrophotometer (Vita Easyshade). Data were analyzed by ANOVA and Kruskal-Wallis test. Results: The statistical analysis showed that there was no statistically significant difference at 5% of significance level between the different groups, independently of the evaluation time, evaluation methods or the use of LED-laser systems. Conclusion: The results suggested that the use of light in the bleaching techniques did not influence the color changes. Copyright: © 2011 Roberto et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pigments of food and beverages could affect dental bleaching efficacy. The aim of this investigation was to evaluate color change and mineral loss of tooth enamel as well as the influence of staining solutions normally used by adolescent patients undergoing home bleaching. Initial hardness and baseline color were measured on enamel blocks. Specimens were divided into five groups (n = 5): G1 (control) specimens were kept in artificial saliva throughout the experiment (3 weeks); G2 enamel was exposed to 10% carbamide peroxide for 6 h daily, and after this period, the teeth were cleaned and stored in artificial saliva until the next bleaching session; and G3, G4, and G5 received the same treatments as G2, but after bleaching, they were stored for 1 h in cola soft drink, melted chocolate, or red wine, respectively. Mineral loss was obtained by the percentage of hardness reduction, and color change was determined by the difference between the data obtained before and after treatments. Data were subjected to analysis of variance and Fisher's test (a = 0.05). G3 and G5 showed higher mineral loss (92.96 +/- 5.50 and 94.46 +/- 1.00, respectively) compared to the other groups (p = 0.05). G5 showed high-color change (9.34 +/- 2.90), whereas G1 presented lower color change (2.22 +/- 0.44) (p = 0.05). Acidic drinks cause mineral loss of the enamel, which could modify the surface and reduce staining resistance after bleaching. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the correlation of color change on bleaching tooth through delta E (ΔE) by the spectrophotometer Spectroshade (SS) and digital program Scanwhite (SW). Methods: 25 patient volunteers were recruited from Operative Dentistry at Universidad de Chile Dental School, between 18 to 30 years, with good oral hygiene. Exclusion criteria: Previous experienced tooth bleaching, anterior restorations, cervical lesions, pain dental, pregnant patient, stained teeth, malposition of the teeth and periodontal pathology. The bleaching was made in two sessions with three different bleaching systems which were randomly. The assessment of color change through ΔE was made on the two upper central incisors (N=50) by the SS and SW. The color in the same teeth were measured before (T0) and after (T1) of the bleaching treatment. Data were analyzed using test Spearman correlation coefficient (Rho) with a significant level of 95%. Results: The results showed a positive and significant correlation (0.676), with a statistically significant difference (p<0.05). Conclusion: There is correlation in the measurement of color change on bleaching tooth by SS and SW.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Composite resins are materials that can present color changing when exposed to pigments. Objective: The aim of this study was to evaluate, in vitro, the color changing of composites after immersion in different substances for different periods. Material and methods: Two microhybrid composite resins: Charisma (Heraeus – Kulzer) and Opallis (FGM) were used. Red wine and acai pulp were also used as immersion medium. For this study, 32 specimens with 10 mm of diameter and 2 mm of thickness were used, divided into 4 groups: Group 1 – Opallis composite immersed in red wine solution; Group 2 – Opallis composite immersed in acai berry pulp solution; Group 3 – Charisma composite immersed in red wine solution; Group 4 – Charisma composite immersed in acai berry pulp solution. The specimens were evaluated in the following time periods: T0 – baseline, T1 – 24 hours, T2 – 48 hours, T3 – 72 hours and T4 – 96 hours. For the assessment of staining, a spectrophotometer for colorimetry was used (Color Guide 45 / 0, PCB 6807 BYK-Gardner Gerestsried GmBH, Germany), and the values obtained were transferred to a computer and recorded according to CIELAB system. Results: The data were evaluated using Kruskal- Wallis non-parametric tests with the following mean values for the immersion periods of 24, 48, 72 and 96 hours, respectively: G1 – 7.35, 7.84, 9.04,10.48; G2 – 2.92, 4.15, 4.30, 4.64; G3 – 3.14, 7.35, 8.13, 8.43, G4 – 4.49, 5.99, 6.92, 6.76. Conclusion: Red wine showed a higher tendency toward altering the composite color than acai berry pulp. In addition, no significant difference was found concerning to the behavior of the two composite resins. Concerning to the immersion time periods, significant differences were only observed among the groups in the 24 hour time period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution-manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24-h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two-way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. Microsc. Res. Tech. 77:941–946, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro-Wilk test (p>0.05 for the different immersion media) and Sidak's test (p<0.05 for the differences between groups). In the interaction between the repolishing and the immersion media, Fluorgard showed a statistical difference between the ∆E values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). Methods: A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n= 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (Na0C1), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 blushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (a= 0.05). Results: For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in Na0C1 and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with Na0C1 and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus--ΔE=2.05; XL 3000--ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus--ΔE=2.05; XL 3000--ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.