AIMS The objective of this study is to evaluate the effects of a paste-like bone substitute material with easy handling properties and improved mechanical stability on periodontal regeneration of intrabony defects in dogs. MATERIALS AND METHODS Mandibular and maxillary first and third premolars were extracted, and three-wall intrabony defects were created on second and fourth premolars. After a healing period of 3 months, acute type defects were filled with a paste-like formulation of deproteinized bovine bone mineral (DBBM) (particle size, 0.125-0.25 mm) in a collagenous carrier matrix (T1), pulverized DBBM (particle size, 0.125-0.25 mm) without the carrier (T2), or Bio-Oss® granules (particle size, 0.25-1.00 mm) as control (C). All defects were covered with a Bio-Gide® membrane. The dogs were sacrificed after 12 weeks, and the specimens were analyzed histologically and histometrically. RESULTS Postoperative healing of all defects was uneventful, and no histological signs of inflammation were observed in the augmented and gingival regions. New cementum, new periodontal ligament, and new bone were observed in all three groups. The mean vertical bone gain was 3.26 mm (T1), 3.60 mm (T2), and 3.81 mm (C). That of new cementum was 2.25 mm (T1), 3.88 mm (T2), and 3.53 mm (C). The differences did not reach statistical significance. The DBBM particles were both incorporated in new bone and embedded in immature bone marrow. CONCLUSIONS The results of this preclinical study showed that the 0.125-0.25-mm DBBM particles in a powder or paste formulation resulted in periodontal regeneration comparable to the commercially available DBBM. Osteoconductivity, in particular, was not affected by DBBM size or paste formulation. CLINICAL RELEVANCE The improved handling properties of the paste-like bone substitute consisting of small DBBM particles embedded in a collagen-based carrier hold promise for clinical applications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE Inhibition of prolyl hydroxylases stimulates bone regeneration. Consequently, bone substitute materials were developed that release prolyl hydroxylase inhibitors. However, the impact of prolyl hydroxylase inhibitors released from these carriers on osteoclastogenesis is not clear. We therefore assessed the effect of bone substitute materials that release prolyl hydroxylase inhibitors on osteoclastogenesis. MATERIAL AND METHODS Dimethyloxalylglycine, desferrioxamine, and l-mimosine were lyophilized onto bovine bone mineral and hydroxyapatite, and supernatants were generated. Osteoclastogenesis was induced in murine bone marrow cultures in the presence of the supernatants from bone substitute materials. The formation of tartrate-resistant acid phosphatase (TRAP)-positive multinucleated cells and TRAP activity were determined. To test for possible effects on osteoclast progenitor cells, we measured the effect of the supernatants on proliferation and viability. In addition, experiments were performed where prolyl hydroxylase inhibitors were directly added to the bone marrow cultures. RESULTS We found that prolyl hydroxylase inhibitors released within the first hours from bone substitute materials reduce the number and activity of TRAP-positive multinucleated cells. In line with this, addition of prolyl hydroxylase inhibitors directly to the bone marrow cultures dose-dependently reduced the number of TRAP-positive multinucleated cells and the overall resorption activity. Moreover, the released prolyl hydroxylase inhibitors decreased proliferation but not viability of osteoclast progenitor cells. CONCLUSION Our results show that prolyl hydroxylase inhibitors released from bone substitute materials decrease osteoclastogenesis in murine bone marrow cultures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM Pharmacological inhibitors of prolyl hydroxylases, also termed hypoxia-mimetic agents (HMAs), when repeatedly injected can support angiogenesis and bone regeneration. However, the possible role of HMA loaded onto bone substitutes to support angiogenesis and bone regeneration under diabetic condition is unknown. The capacity of HMA loaded onto deproteinized bovine bone mineral (DBBM) to support angiogenesis and bone formation was examined in diabetic Wistar rats. METHODS Diabetes was induced by intraperitoneal injection of streptozotocin. The HMA dimethyloxalylglycine (DMOG) and desferrioxamine (DFO) were lyophilized onto DBBM. Calvarial defects were created with a trephine drill and filled with the respective bone substitutes. After 4 weeks of healing, the animals were subjected to histological and histomorphometric analysis. RESULTS In this report, we provide evidence that DMOG loaded onto DBBM can support angiogenesis in vivo. Specifically, we show that DMOG increased the vessel area in the defect site to 2.4% ± 1.3% compared with controls 1.1% ± 0.48% (P = 0.012). There was a trend toward an increased vessel number in the defect site with 38.6 ± 17.4 and 31.0 ± 10.3 in the DMOG and the control group (P = 0.231). The increase in angiogenesis, however, did not translate into enhanced bone formation in the defect area with 9.2% ± 7.1% and 8.4% ± 5.6% in DMOG and control group, respectively. No significant changes were caused by DFO. CONCLUSIONS The results suggest that DMOG loaded onto DBBM can support angiogenesis, but bone formation does not increase accordingly in a type 1 diabetic rat calvarial defect model at the indicated time point.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The thermal bone necrosis induced during a drilling process is a frequent and potential phenomenon, which contributes to post-operative problems. The frictional heat generated from the contact between the drill bit and the hole wall is unavoidable. However, understanding advanced techniques for acquiring reliable thermal data on bone drilling is important to ensure the quality of the drilled hole. The purpose of this study is to present two different experimental methods to analyse the drilling conditions that generate the lower temperatures, avoiding the occurrence of thermal bone necrosis. Ex-vivo bovine bones were used to simulate the drilling process considering the effect of drill bit diameter, drill speed and feed-rate. Different experiments were performed to assess the repeatability of the tests. The results identified the drill bit diameter as the most critical parameter for inducing higher temperatures in bone drilling.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

he thermal bone necrosis induced during a drilling process is a frequent and potential phenomenon, which contributes to post-operative problems. The frictional heat generated from the contact between the drill bit and the hole wall is unavoidable. However, understanding advanced techniques for acquiring reliable thermal data on bone drilling is important to ensure the quality of the drilled hole.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bone is a dynamic, highly vascularized tissue with a unique capacity to heal and regenerate without scarring. However, drilling remains a concern in several clinical procedures due to thermal damage of the bone and surrounding tissue. The success of this surgeries is dependent of many factors and also in temperature generation during the drilling bone. When an excessive heat is produced during the drilling, thermal necrosis can occur and the bone suffers injuries. Studies have shown that the increased temperature is directly related with the drilling parameters, particularly, the drill speed, feed-rate, applied force, the depth of cut, the geometry of the drill bit, the use or not of a cooling system and also the type of bone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. Methods: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex (R)). Results: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex (R) and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex (R) screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). Conclusion: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Our purpose was to evaluate the osteoconduction potential of mixed bovine bone (MBB) xenografts as an alternative for bone grafting of critical-size defects in the calvaria of rats. After surgery, in the time intervals of 1, 3, 6, and 9 months, rats were killed and their skulls collected, radiographed and histologically prepared for analysis. The data obtained from histological analysis reported that the particles of MBB did not promote an intense immunological response, evidencing its biocompatibility in rats. Our results clearly showed the interesting evidence that MBB was not completely reabsorbed at 9 months while a small amount of newly formed bone was deposited by osteoprogenitor cells bordering the defect. However, this discrete bone-forming stimulation was unable to regenerate the bone defect. Overall, our results suggest that the properties of MBB are not suitable for stimulating intense bone regeneration in critical bone defects in rats.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Our goal was to evaluate bone neoformation promoted by a bovine xenograft composite (XC) compared with autogenous graft for maxillary sinus augmentation in a rabbit model. The left maxillary sinus of 18 male rabbits was filled with 200 mg of cortical and cancellous autogenous bone and the right sinus was filled with 200 mg of a composite comprised organic and inorganic bovine matrices, pool of bBMPs and collagen. Postoperative implant intervals of 2, 4, and 8 weeks were analyzed. Differences in the bone optical density among the groups and experimental periods were evaluated by computed tomography analysis. The tissue response was evaluated by histomorphometric analysis of the newly formed bone, connective tissue and/or granulation tissue, residual material, and bone marrow. The tomographic analyses showed a maximum optical density in the 4-week period for both groups. Histologically, an inflammatory infiltrate was observed at 2 weeks in the XC group but exclusively around the organic particles of the biomaterial. Regarding to the amount of newly formed bone, no statistical differences (p > 0.05) were observed among the two treatments throughout the implant intervals. However, by the end of the 8 weeks, the quantity of bone marrow was two times greater (p < 0.05) in the control group than in the XC group. In conclusion, the xenograft composite promotes formation of new bone in a similar fashion to autogenous bone and could therefore be considered a biomaterial with potential applications as a bone substitute in maxillary sinus floor augmentation. (C) 2007 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Theoretically myocardial angiogenesis of laser injury can be further enhanced by the addition of angiogenic growth factors. The influence of the way of administration of these factors on vascular growth around the channels is still unclear. MATERIALS AND METHODS: 18 pigs (mean weight 72 +/- 5.2 kg) were randomized to either triads of transmyocardial laser revascularization (TMLR) channels (group 1, n = 6) or isolated channels (group 2, n = 6), or a control group (n = 6). The animals had injections of bovine bone derived growth factor mixture either in the center of the triads in group 1 or within the channels themselves in group 2. Animals were sacrificed one month later for histological analysis. RESULTS: The vascular densities of myocardial areas within the triads of group 1 and around the channels in group 2 were significantly larger than in the control group: 15.2 +/- 3.7/mm2 and 14.2 +/- 3.5/mm2 respectively vs 5.3 +/- 1.6/mm2 (p < 0.001 for both differences). Differences of densities between group 1 and 2 were not statistically significant (p = 0.6). CONCLUSIONS: In this porcine model, the addition of a bovine bone derived growth factor mixture to TMLR significantly stimulates angiogenesis in the areas adjacent to the channels. The place of injection does not influence the angiogenesis intensity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare new bone formation in maxillary sinus augmentation procedures using biomaterial associated with mesenchymal stem cells (MSCs) separated by two different isolation methods. Background: In regenerative medicine open cell concentration systems are only allowed for clinical application under good manufacturing practice conditions. Methods: Mononuclear cells, including MSCs, were concentrated with either the synthetic poylsaccharid (FICOLL) method (classic open system-control group, n = 6 sinus) or the bone marrow aspirate concentrate (BMAC) method (closed system-test group, n = 12 sinus) and transplanted in combination with biomaterial. A sample of the cells was characterized by their ability to differentiate. After 4.1 months (SD +/- 1.0) bone biopsies were obtained and analyzed. Results: The new bone formation in the BMAC group was 19.9% (90% confidence interval [CI], 10.9-29), and in the FICOLL group was 15.5% (90% CI, 8.6-22.4). The 4.4% difference was not significant (90% CI, -4.6-13.5; p = 0.39). MSCs could be differentiated into osteogenic, chondrogenic, and adipogenic lineages. Conclusion: MSCs harvested from bone marrow aspirate in combination with bovine bone matrix particles can form lamellar bone and provide a reliable base for dental implants. The closed BMAC system is suited to substitute the open FICOLL system in bone regeneration procedures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim To evaluate the influence of magnesium-enriched hydroxyapatite (MHA) (SintLife (R)) on bone contour preservation and osseointegration at implants placed immediately into extraction sockets. Material and methods In the mandibular pre-molar region, implants were installed immediately into extraction sockets of six Labrador dogs. MHA was placed at test sites, while the control sites did not receive augmentation materials. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation. Results After 4 months of healing, one control implant was not integrated leaving n=5 test and control implants for evaluation. Both at the test and the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between test and control sites, the alveolar bony crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 0.7 mm) compared with the control sites (loss: 1.2 mm), even though this difference did not reach statistical significance. Conclusions The use of MHA to fill the defect around implants placed into the alveolus immediately after tooth extraction did not contribute significantly to the maintenance of the contours of the buccal alveolar bone crest. To cite this article:Caneva M, Botticelli D, Stellini E, Souza SLS, Salata LA, Lang NP. Magnesium-enriched hydroxyapatite at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 22, 2011; 512-517doi: 10.1111/j.1600-0501.2010.02040.x.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a method based on the theory of electromagnetic waves reflected to evaluate the behavior of these waves and the level of attenuation caused in bone tissue. For this, it was proposed the construction of two antennas in microstrip structure with resonance frequency at 2.44 GHz The problem becomes relevant because of the diseases osteometabolic reach a large portion of the population, men and women. With this method, the signal is classified into two groups: tissue mass with bony tissues with normal or low bone mass. For this, techniques of feature extraction (Wavelet Transform) and pattern recognition (KNN and ANN) were used. The tests were performed on bovine bone and tissue with chemicals, the methodology and results are described in the work

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work holds the purpose of presenting an auxiliary way of bone density measurement through the attenuation of electromagnetic waves. In order to do so, an arrangement of two microstrip antennas with rectangular configuration has been used, operating in a frequency of 2,49 GHz, and fed by a microstrip line on a substrate of fiberglass with permissiveness of 4.4 and height of 0,9 cm. Simulations were done with silica, bone meal, silica and gypsum blocks samples to prove the variation on the attenuation level of different combinations. Because of their good reproduction of the human beings anomaly aspects, samples of bovine bone were used. They were subjected to weighing, measurement and microwave radiation. The samples had their masses altered after mischaracterization and the process was repeated. The obtained data were inserted in a neural network and its training was proceeded with the best results gathered by correct classification on 100% of the samples. It comes to the conclusion that through only one non-ionizing wave in the 2,49 GHz zone it is possible to evaluate the attenuation level in the bone tissue, and that with the appliance of neural network fed with obtained characteristics in the experiment it is possible to classify a sample as having low or high bone density