967 resultados para bioanalytical method validation
Resumo:
Choline citrate (CC) and acetylmethionine (AM) are lipotropic drugs used in several pharmaceutical formulations. The objective of this research was to develop and validate a high performance liquid chromatographic (HPLC) method for simultaneous determination of CC and AM in injectable solutions, aiming its application in routine analysis for quality control of these pharmaceutical formulations. The method was validated using a Shim-Pack (R) C18 (250 x 4.6 mm, 5 mu m) column. The mobile phase was constituted of 25 mM potassium phosphate buffer solution, pH 5.7, adjusted with 10 % orthophosphoric acid, acetonitrile and methanol (88:10:2, v/v/v). The flow rate was 1.1 mL.min(-1) and the UV detection was made at 210 nm. The analyses were made at room temperature (25 +/- 1 degrees C). The method is precise, selective, accurate and robust, and was successfully applied for simultaneous quantitative determination of CC and AM in injectables.
Resumo:
The aim of this study was to develop and validate selective and sensitive methods for quantitative determination of an antibacterial agent, gemifloxacin, in tablets by high performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). The HPLC method was carried out on a LiChrospher (R) 100 RP-8e, 5 mu m (125 x 4 mm) column with a mobile phase composed of tetrahydrofuran-water (25:75, v/v) with 0.5 % of triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The CZE method was performed using 50 mM sodium tetraborate buffer (pH 8.6). Samples were injected hydrodynamicaly (0.5 psi, 5 s) and the electrophoretic system was operated under normal polarity, at +20 kV and capillary temperature of 18 degrees C. A fused-silica capillary 40.2 cm (30 cm effective length) x 75 mu m i.d. was used. Both, HPLC and CZE could be interesting and efficient techniques to be applied for quality control in pharmaceutical industries.
Resumo:
Rutin is employed as antioxidant and to prevent the capillary fragility and, when incorporated in cosmetic emulsions, it must target the action site. In vitro cutaneous penetration studies through human skin is the ideal situation, however, there are difficulties to obtain and to maintain this tissue viability. Among the membrane models, shed snake skin presents itself as pure stratum corneum, providing barrier function similar to human and it is obtained without the animal sacrifice. The objectives of this research were the development and stability evaluation of a cosmetic emulsion containing rutin and propylene glycol (penetration enhancer) and the evaluation or rutin in vitro cutaneous penetration and retention from the emulsion, employing an alternative model biomembrane. Emulsion was developed with rutin and propylene glycol, both at 5.0% w/w. Active substance presented on the formulation was quantified by a validated spectrophotometric method at 361.0 nm. Rutin Rutin cutaneous penetration and retention was performed in vertical diffusion cells with shed snake skin of Crotalus durissus, as alternative model biomembrane, and distilled water and ethanol 99.5% (1:1), as receptor fluid. The experiment was conducted for six hours, at 37.0 +/- 0.5 degrees C with constant stirring of 300 rpm. Spectrophotometry at 410.0 nm, previously validated, determined the active substance after cutaneous penetration/ retention. Emulsion did not promote rutin cutaneous penetration through C. durissus skin, retaining 0.931 +/- 0.0391 mu g rutin/mg shed snake skin. The referred formulation was chemically stable for 30 days after stored at 25.0 +/- 2.0 degrees C, 5.0 +/- 0.5 degrees C and 45.0 +/- 0.5 degrees C. In conclusion, it has not been verified the active cutaneous penetration through the model biomembrane, but only its retention on the Crotalus durissus stratum corneum, condition considered stable for 30 days.
Resumo:
A selective and reproducible off-line solid-phase microextraction procedure was developed for the simultaneous enantioselective determination of mirtazapine (MRT), demethylmirtazapine and 8-hydroxymirtazapine in human urine. CE was used for optimization of the extraction procedure whereas LC-MS was used for method validation and application. The influence of important factors in the solid-phase microextraction efficiency is discussed, such as the fiber coatings, extraction time, pH, ionic strength, temperature and desorption time. Before extraction, human urine samples were submitted to enzymatic hydrolysis at 37 degrees C for 16 h. Then, the enzyme was precipitated with trichloroacetic acid and the pH was adjusted to 8 with 1 mol/L pH 11 phosphate buffer solution. In the extraction, the analytes were transferred from the aqueous solution to the polydimethylsiloxane-divinylbenzene fiber coating and then desorbed in methanol. The mean recoveries were 5.4, 1.7 and 1.0% for MRT, demethylmirtazapine and 8-hydroxymirtazapine enantiomers, respectively. The method was linear over the concentration range of 62-1250 ng/mL. The within-day and between-day assay precision and accuracy were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic MRT to a healthy volunteer.
Resumo:
A new nitrosyl ruthenium complex [Ru(NH center dot NHq)(terpy)NO](3+) nitric oxide donor was recently developed and due to its excellent vasodilator activity, it has been considered as a potential drug candidate. Drug metabolism is one of the main parameters that should be evaluated in the early drug development, so the biotransformation of this complex by rat hepatic microsomes was investigated. In order to perform the biotransformation study, a simple, sensitive and selective HPLC method was developed and carefully validated. The parameters evaluated in the validation procedure were: linearity, recovery, precision, accuracy, selectivity and stability. Except for the stability study, all the parameters evaluated presented values below the recommended by FDA guidelines. The stability study showed a time-dependent degradation profile. After method validation, the biotransformation study was accomplished and the kinetic parameters were determined. The biotransformation study obeyed the Michaelis-Menten kinetics. The V(max) and K(m) were, respectively, 0.1625 +/- 0.010 mu mol/mg protein/min and 79.97 +/- 11.52 mu M. These results indicate that the nitrosyl complex is metabolized by CYP450. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Analytical and bioanalytical methods of high-performance liquid chromatography with fluorescence detection (HPLC-FLD) were developed and validated for the determination of chloroaluminum phthalocyanine in different formulations of polymeric nanocapsules, plasma and livers of mice. Plasma and homogenized liver samples were extracted with ethyl acetate, and zinc phthalocyanine was used as internal standard. The results indicated that the methods were linear and selective for all matrices studied. Analysis of accuracy and precision showed adequate values, with variations lower than 10% in biological samples and lower than 2% in analytical samples. The recoveries were as high as 96% and 99% in the plasma and livers, respectively. The quantification limit of the analytical method was 1.12 ng/ml, and the limits of quantification of the bioanalytical method were 15 ng/ml and 75 ng/g for plasma and liver samples, respectively. The bioanalytical method developed was sensitive in the ranges of 15-100 ng/ml in plasma and 75-500 ng/g in liver samples and was applied to studies of biodistribution and pharmacokinetics of AlClPc. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Objectives/Hypothesis: Polysomnography (PSG) is the gold-standard method for diagnosing obstructive sleep apnea (OSA). However, the gap between demand and capacity in performing PSG is a major health-care problem. We sought to validate a short day-time induced sleep for the diagnosis of OSA. Study Design: Prospective diagnostic method validation. Methods: We studied 25 consecutive patients referred to the sleep laboratory and 15 healthy volunteers. All subjects were evaluated by means of full overnight PSG (Full-PSG) and short day-time induced-sleep PSG (Induced-PSG). Sleep was monitored during both procedures (Embla, 16 channels). Sleep was induced by slow intravenous drip infusion of midazolam. Results: The population studied (N = 40) was 60% male (mean age, 42 +/- 10 years; body mass index, 29 +/- 6.5 kg/m(2)). Sleep was successfully induced in all subjects, and no complications were observed (midazolam doses, 6.2 +/- 3.8 mg; time of induced sleep 41.5 +/- 18.9 minutes). The apnea-hypopnea index (AHI) and minimal oxygen saturation during Full-PSG versus Induced-PSG were similar: median AHI (with 25%-75% interquartile range) was 13 (3-35) events per hour versus 17 (4-36) events per hour, and median oxygen saturation was 84% (75-90) versus 85% (76-92); P = .89 and P = .53, respectively. The majority of the respiratory events during induced sleep were obstructive and similar to those observed during Full-PSG. AHI and lowest oxygen saturation during Induced-PSG correlated significantly with Full-PSG (r = 0.67 and r = 0.77, respectively). Sensitivity and specificity for the diagnosis of OSA (AHI > 15 events per hour) by Induced-PSG were 0.83 and 0.72, respectively. Conclusions: Induced-PSG by midazolam during the day is safe and correlates with Full-PSG; it therefore is a promising alternative method in the diagnosis of OSA.
Resumo:
Predictions of flow patterns in a 600-mm scale model SAG mill made using four classes of discrete element method (DEM) models are compared to experimental photographs. The accuracy of the various models is assessed using quantitative data on shoulder, toe and vortex center positions taken from ensembles of both experimental and simulation results. These detailed comparisons reveal the strengths and weaknesses of the various models for simulating mills and allow the effect of different modelling assumptions to be quantitatively evaluated. In particular, very close agreement is demonstrated between the full 3D model (including the end wall effects) and the experiments. It is also demonstrated that the traditional two-dimensional circular particle DEM model under-predicts the shoulder, toe and vortex center positions and the power draw by around 10 degrees. The effect of particle shape and the dimensionality of the model are also assessed, with particle shape predominantly affecting the shoulder position while the dimensionality of the model affects mainly the toe position. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.
Resumo:
O presente Relatório de Estágio teve como objectivo analisar e discutir as competências adquiridas e desenvolvidas, durante o estágio, no controlo da qualidade microbiológica na indústria farmacêutica O estágio, foi realizado no Laboratório de Microbiologia dos Laboratórios Atral, Grupo AtralCipan, localizado na Vala do Carregado, Castanheira do Ribatejo. Este teve a duração de aproximadamente dez meses e meio, com data de início a 21 de Setembro de 2011 e final de 10 de Agosto de 2012. Numa fase inicial, foram adquiridas as aptidões necessárias para a aplicação das metodologias realizadas no laboratório de microbiologia com o estudo das normas, procedimento e legislação aplicada, com foco na importância das farmacopeias na indústria farmacêutica e formação para a realização de ensaios em Áreas de Processamento Asséptico, conhecendo e compreendendo os procedimentos a ter nestas. Uma das principais metodologias realizadas, e desenvolvida neste relatório, compreendeu a análise de produtos farmacêuticos estéreis, com a aplicação de Testes de Esterilidade, pelo método de STERITEST e método Directo, com resultados que demonstraram a importância destas técnicas, da avaliação do ambiente em que são realizadas e do operador que as executa. Os Testes de Promoção de Crescimento, foram também explorados neste trabalho, realizados não só para avaliação dos meios de cultura, onde foi possível analisar os requisitos e resultados obtidos, como também para validação de metodologias, nomeadamente, na validação de meios e fluidos de marcas diferentes para utilização no método STERITEST e na validação do método de filtração de membrana para Enumeração Microbiana de um produto não estéril. Estas validações possibilitaram a redução de custos e melhoria das condições da análise e metodologias aplicadas. Com a realização do estágio foi possível adquirir aptidões práticas, que aliadas ao conhecimento teórico obtido no mestrado, proporcionaram um crescimento a nível pessoal, científico e profissional.
Resumo:
A validação metodológica permite evidenciar se os resultados obtidos por um método são confiáveis, tornando-se um elemento essencial na qualidade. Neste estudo, cujo objectivo é validar a metodologia enzimática para determinação de oxalato na urina, incluíram-se 30 amostras de urina de 24horas, pré-tratadas e estudadas em dois auto-analisadores. Os valores dos limites de detecção e quantificação foram 0,98 e 0,79 mg/L, respectivamente. Para a exactidão obteve-se p=0,713. Na precisão intermédia entre corridas não existem diferenças estatisticamente significativas, em oposição às repetições. Para a linearidade obteve-se r=1 e a sensibilidade foi 0,6%. Conclui-se que o método se mostrou exacto e linear.
Resumo:
Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.
Resumo:
The Quinone outside Inhibitors (QoI) are one of the most important and recent fungicide groups used in viticulture and also allowed by Integrated Pest Management. Azoxystrobin, kresoxim-methyl and trifloxystrobin are the main active ingredients for treating downy and powdery mildews that can be present in grapes and wines. In this paper, a method is reported for the analysis of these three QoI-fungicides in grapes and wine. After liquid–liquid extraction and a clean-up on commercial silica cartridges, analysis was by isocratic HPLC with diode array detection (DAD) with a run time of 13 min. Confirmation was by solid-phase micro-extraction (SPME), followed by GC/MS determination. The main validation parameters for the three compounds in grapes and wine were a limit of detection up to 0.073mg kg-1, a precision not exceeding 10.0% and an average recovery of 93% ±38.
Resumo:
A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.
Resumo:
A eritropoietina (EPO) é uma substância que estimula a produção de eritrócitos, aumentando a oxigenação muscular, sendo segregada de forma natural pelo organismo e excretada na urina em baixas concentrações. Devido às suas propriedades e características, a EPO foi rapidamente introduzida no mundo do desporto, como substância ilícita, proporcionando vantagens no rendimento desportivo. No início de 2000 foi desenvolvido um método de deteção direta de EPO Recombinante (rHuEPO) em urina humana por Lasne, baseado na focalização isoelétrica (IEF) em gel de poliacrilamida, seguido de duplo blote, tendo este sido publicado e validado. Em 2002, a Agência Mundial Antidopagem (AMA) implementou este mesmo método, sendo atualmente um dos métodos oficiais utilizado pelos laboratórios acreditados pela AMA. Desta forma, o ponto de partida para a realização deste trabalho consistiu na necessidade de implementar e validar o método de referência de IEF para a deteção de rHuEPO em urina humana. O trabalho foi realizado no Laboratório de Análises e Dopagem (LAD) do Instituto do Desporto de Portugal (IDP), atual Instituto Português do Desporto e Juventude (IPDJ). O principal objetivo deste trabalho consistiu no estudo/investigação de diferentes parâmetros de validação (especificidade/seletividade; capacidade de identificação; limite de deteção; exatidão e repetibilidade), de acordo com o protocolado no Procedimento Geral interno do Laboratório de Análises de Dopagem de Lisboa (LAD). O referido método de triagem e confirmação revelou possuir características de desempenho conformes com os requisitos aplicáveis, pelo que é considerado validado e apto.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica