950 resultados para X-rays: bursts


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knowledge of landmarks and contours in anteroposterior (AP) pelvis X-rays is invaluable for computer aided diagnosis, hip surgery planning and image-guided interventions. This paper presents a fully automatic and robust approach for landmarking and segmentation of both pelvis and femur in a conventional AP X-ray. Our approach is based on random forest regression and hierarchical sparse shape composition. Experiments conducted on 436 clinical AP pelvis x-rays show that our approach achieves an average point-to-curve error around 1.3 mm for femur and 2.2 mm for pelvis, both with success rates around 98%. Compared to existing methods, our approach exhibits better performance in both the robustness and the accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In clinical practice, traditional X-ray radiography is widely used, and knowledge of landmarks and contours in anteroposterior (AP) pelvis X-rays is invaluable for computer aided diagnosis, hip surgery planning and image-guided interventions. This paper presents a fully automatic approach for landmark detection and shape segmentation of both pelvis and femur in conventional AP X-ray images. Our approach is based on the framework of landmark detection via Random Forest (RF) regression and shape regularization via hierarchical sparse shape composition. We propose a visual feature FL-HoG (Flexible- Level Histogram of Oriented Gradients) and a feature selection algorithm based on trace radio optimization to improve the robustness and the efficacy of RF-based landmark detection. The landmark detection result is then used in a hierarchical sparse shape composition framework for shape regularization. Finally, the extracted shape contour is fine-tuned by a post-processing step based on low level image features. The experimental results demonstrate that our feature selection algorithm reduces the feature dimension in a factor of 40 and improves both training and test efficiency. Further experiments conducted on 436 clinical AP pelvis X-rays show that our approach achieves an average point-to-curve error around 1.2 mm for femur and 1.9 mm for pelvis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low energy X-rays Intra-Operative Radiation Therapy (XIORT) treatment delivered during surgery (ex: INTRABEAM, Carl Zeiss, and Axxent, Xoft) can benefit from accurate and fast dose prediction in a patient 3D volume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and macroscopic breadth (i.e., microplanar). Thirty-six rats were exposed head-on either to an upright 4-mm-high, 20- or 37-microns-wide beam or to a horizontal 7-mm-wide, 42-microns-high beam of mostly 32- to 126-keV, minimally divergent x-rays from the X17 wiggler at the National Synchrotron Light Source at Brookhaven National Laboratory. Parallel slices of the head, separated at either 75 or 200 microns on center, were exposed sequentially at 310-650 grays (Gy) per second until each skin-entrance absorbed dose reached 312, 625, 1250, 2500, 5000, or 10,000 Gy. The rats were euthanized 2 weeks or 1 month later. Two rats with 10,000-Gy-entrance slices developed brain tissue necrosis. All the other 10,000- and 5000-Gy-entrance slices and some of the 2500- and 1250-Gy-entrance slices showed loss of neuronal and astrocytic nuclei and their perikarya. No other kind of brain damage was evident histologically in any rat with entrance absorbed doses < or = 5000 Gy. Brain tissues in and between all the 312- and 625-Gy-entrance slices appeared normal. This unusual resistance to necrosis is central to the rationale of microplanar beam radiation therapy for brain tumors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The availability of a large amount of observational data recently collected from magnetar outbursts is now calling for a complete theoretical study of outburst characteristics. In this Letter (the first of a series dedicated to modeling magnetar outbursts), we tackle the long-standing open issue of whether or not short bursts and glitches are always connected to long-term radiative outbursts. We show that the recent detection of short bursts and glitches seemingly unconnected to outbursts is only misleading our understanding of these events. We show that, in the framework of the starquake model, neutrino emission processes in the magnetar crust limit the temperature, and therefore the luminosity. This natural limit to the maximum luminosity makes outbursts associated with bright persistent magnetars barely detectable. These events are simply seen as a small luminosity increase over the already bright quiescent state, followed by a fast return to quiescence. In particular, this is the case for 1RXS J1708–4009, 1E 1841–045, SGR 1806–20, and other bright persistent magnetars. On the other hand, a similar event (with the same energetics) in a fainter source will drive a more extreme luminosity variation and longer cooling time, as for sources such as XTE J1810–197, 1E 1547–5408, and SGR 1627–41. We conclude that the non-detection of large radiative outbursts in connection with glitches and bursts from bright persistent magnetars is not surprising per se, nor does it need any revision of the glitches and burst mechanisms as explained by current theoretical models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reprinted from the Transactions of the Faraday Society, v.15, pt.2, 1919.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bibliography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Illustrative extracts from the writings of Paul P. Ewald and of Max von Laue are presented. The latter in turn contains extensive text contributions from William Lawrence Bragg. These selections we have chosen so as to indicate the nature of the discovery of X-ray diffraction from crystals (experiments undertaken by Friedrich, Knipping and von Laue) and its early and prompt application in crystal structure analyses (by William Henry Bragg and William Lawrence Bragg). The platform for these discoveries was provided by a macroscopic physics problem dealt with by Ewald in his doctoral thesis with Arnold Sommerfeld in the Munich Physics Department, which is also where von Laue was based. W.L. Bragg was a student in Cambridge who used Trinity College Cambridge as his address on his early papers; experimental work was done by him in the Cavendish Laboratory, Cambridge, and also with his father, W.H. Bragg, in the Leeds University Physics Department. Of further historical interest is the award of an Honorary DSc (Doctor of Science) degree in 1936 to Max von Laue by the University of Manchester, UK, while William Lawrence Bragg was Langworthy Professor of Physics there. © 2012 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiotherapy (RT) has recently evolved with the emergence of heavy ion radiations or new fractionation schemes of photon therapy, which modify the dose rate of treatment delivery. The aim of the present study was then to evaluate the in vitro influence of a ultra-high dose rate comparing them with standard dose rate. In this regard, a radioresistant SK-MEL-28 cell line were irradiated with x-ray in order to have a total dose of 2 and 4 Gy, at two different dose rate. The ultra-high dose rate is a specific property of the dense plasma focus (DPF) device, which has pulsed operation and thus gives short and highly energetic pulses of multiple types of rays and particles, in this case, we focused our study on the influence of X-rays. While a low dose rate is obtained with conventional X-ray tube. In this study it results that a ultra-high dose rate enhances radiosensitivity of melanoma cells while reducing the adhesion, proliferation and migration ability of cells.