999 resultados para Voltammetric detection
Resumo:
This work presents an electroanalytical method based on square-wave voltammetry (SWV) for the determination of quinizarine (QNZ) in a mixture of Britton-Robinson buffer 0.08 mol L-1 with 30% of acetonitrile. The QNZ was oxidized at glassy carbon electrode in and the well-defined peak at +0.45 V vs. Ag/AgCl can be used for its determination as colour marker in fuel samples. All parameters were optimized and analytical curves can be constructed for QNZ concentrations ranging from 2.0 x 10(-6) mol L-1 to 1.4 x 10(-5) mol L-1, using f = 60 Hz and E-sw = 25 mV. The method offers a limit detection of 4.12 x 10(-7) mol L-1 and a standard deviation of 4.5% when six measurements of 1.25 x 10(-5) mol L-1 are compared. The method was successfully applied for determining QNZ in gasoline and diesel oil and the obtained results showed good agreement with those reported previously. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Cefaclor is not reducible at a mercury electrode, but it can be determined polarographically and by cathodic stripping voltammetry as its initial alkaline degradation product which is obtained in high yield by hydrolysis of cefaclor in Britton-Robinson (B-R) buffer pH 10 at 50 degrees C for 30 min (reduction peak at pH 10, -0.70 V). Differential pulse polarographic calibration graphs are linear up to at least 1 x 10(-4) mol l(-1). Recoveries of 93% of the cefaclor (n = 3) were obtained from urine spiked with 38.6 mu g ml(-1) using this polarographic method with 1 ml urine made up to 10 ml with pH 10 buffer. Using cathodic stripping voltammetry and accumulating at a hanging mercury drop electrode at -0.2 V for 30 s, linear calibration graphs were obtained from 0.35 to 40 mu g ml(-1) cefaclor in B-R buffer pH 10. A relative standard deviation of 4.2% (eta = 5) was obtained, and the limit of detection was calculated to be 2.9 ng ml(-1). Direct determination of cefaclor in human urine (1 ml of urine was made up to 10 ml with pH 10 buffer) spiked to 0.39 mu g ml(-1) was made (recovery 98.6%). (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
Sodium nitroprusside (NP), a commercial vasodilator, can be pre-concentrated on vitreous carbon electrode modified by films of 97.5%: 2.5% Poly-L-lysine (PLL): glutaraldehyde (GA). This coating gives acceptable anion exchange properties whilst giving the required improvement of adhesion to the glassy carbon electrode surface. Linear response range and detection limit on nitroprusside in B-R buffer pH 4.0, were 1 x 10(-6) to 2 x 10-(5) mol L-1 and 1 x 10(-7) mol L-1, respectively. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was measured as 4.1% for 10 experiments. The voltammetric sensor was directly applied to determination of nitroprusside in human plasma and urine samples and the average recovery for these samples was around 95-97% without any pre treatment.
Resumo:
A simple, rapid inexpensive voltammetric method have been developed for the quantitative determination of albendazole (ABZ) as the pure assay, by direct dissolution of commercial tablets in HCl solutions. Studies with linear sweep (LSV), square-wave (SWV) and differential pulse voltammetry (DPV) were carried out ABZ in aqueous medium at a glassy carbon electrode. A well defined irreversible oxidation peak current was obtained at 1,00V vs. SCE. The method permits a precise quantitative determination of ABZ using the standard addition method. The detection limits for the three voltammetric techniques were found to be 3.0 x 10(-5) M (LSV), 6.2 x 10(-5) M (SWV) and 4.0 x 10(-5) M (DPV).
Resumo:
Cromoglycate is accumulated on a poly-L-lysine (PLL) modified carbon electrode best from pH 4 solution, where it is anionic and the PLL is cationic, and at which pH the cromoglycate gives a good reduction peak at -0.82 V. The PLL film can be regenerated readily by washing the electrode with 3 M sodium hydroxide solution, in which the PLL is deprotonated. Regeneration of the film is not required as frequently when larger amounts of PLL are incorporated into it. This allows standard addition procedures to be carried out without regenerating the electrode. Linear calibration graphs have been obtained typically in the range 0.1 - 1.5 mug ml(-1). Detection limits have been calculated to be 10 ng ml(-1). The standard addition method has been applied satisfactorily to diluted urine solutions. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
The cyclic voltammetric behavior of acetaldehyde and the derivatized product with 2,4-dinitrophenylhydrazine (DNPHi) has been studied at a glassy carbon electrode. This study was used to optimize the best experimental conditions for its determination by high-performance liquid chromatographic (HPLC) separation coupled with electrochemical detection. The acetaldehyde-2,4-dinitrophenyl.hydrazone (ADNPH) was eluted and separated by a reversed-phase column, C-18, under isocratic conditions with the mobile phase containing a binary mixture of methanol/LiCl(aq) at a concentration of 1.0 x 10(-3) M (80:20 v/v) and a flow rate of 1.0 mL min(-1). The optimum condition for the electrochemical detection of ADNPH was +1.0 V vs. Ag/AgCl as a reference electrode. The proposed method was simple, rapid (analysis time 7 min) and sensitive (detection limit 3.80 mu g L-1) at a signal-to-noise ratio of 3:1. It was also highly selective and reproducible [standard deviation 8.2% +/- 0.36 (n = 5)]. The analytical curve of ADNPH was linear over the range of 3-300 mg L-1 per injection (20 mu L), and the analytical recovery was > 99%.
Resumo:
Primaquine, an antimalarial drug, presents a well-defined oxidation peak around +0.6V vs SCE at a glassy carbon electrode that can be used for its determination. Calibration graphs were obtained for primaquine in B-R buffer pH 4.0 from 3.00 x 10(-5) mol L-1 to 1.00 x 10(-2) mol L-1 using linear-scan voltammetry and 3.00 x 10(-5) mol L-1 to 1.00 x 10(-2) mol L-1 using differential pulse or square-wave voltammetry. The correspondent detection limits was 9.4 mu g mL(-1); 4.2 and 1.8 mu g mL(-1), respectively. All the voltammetric methods were applied with success in direct determination of the primaquine in commercial tablets without separation or extraction procedures.
Resumo:
Iron nitroprusside Fe(II)NP was incorporated into a carbon paste electrode and the electrochemical studies were performed with cyclic voltammetry. The cyclic voltammogram of Fe(II)NP exhibits two redox couple with formal potential (E0')1 = 0.24 e (E0')2 = 0.85 V vs SCE attributed to Fe(II)/Fe(II) and Fe (II)(CN)5NO/Fe(III)(CN)5NO, respectively. The redox couple with (E0')2 = 0.85 V presents an electrocatalytic response for sulfhydryl compounds. The electrocatalytic oxidation of sulfhydryl compounds by the mediator has been used for the determination of L-cysteine and N-acetylcysteine. The modified graphite paste electrode gives a linear range from 9.2 x 10-4-2.0 x 10-2;; 9.6 x 10-4-1.4 x 10-2mol L-1 for the determination of L-cysteine and N-acetylcysteine, respectively, with detection limit of 1.9 x 10-4 mol L-1;; 1.5 x 10 -4 mol L-1 and relative standard desviations ± 5% and 1.5 x 10-3 mol L-1 ± 4% (n=3). The amperometric sensitivities are 0.024 and 0.027 μA/μmol L-1 for L-cysteine and N-acetylcysteine, respectively. The application of this electrode was tested and a commercial pharmaceutical product (Fluimucil) has been determined.
Resumo:
The preparation and electrochemical characterization of a carbon paste electrode modified with N.N′-ethylenebis(salicylideneiminato) oxovanadium(IV) complex ([VO(Salen)]) as well as its behavior as electrocatalyst toward the oxidation of dipyrone were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of dipyrone were explored using cyclic voltammetry. The voltammetric response of the modified electrode is based on two reactions. One electrochemical related to the oxidation of the metallic center of the [VO(Salen)] and the other involving the chemical redox process involving the oxidized form of the complex and the reduced form of dipyrone. The best voltammetric response was observed for a paste composition of 25% (m/m) [VO(Salen)], KCl solution pH from 5.5 to 8.0 as the electrolyte and potential scan rate of 10 mV s-1 in the presence of dipyrone. A linear voltammetric response for dipyrone was obtained in the concentration range from 9.9 × 106 to 2.8 × 10 -3 mol L-1, with a detection limit of 7.2 × 10 -6 mol L-1. Among of several compounds tested as potential interference, only ascorbic acid presented some interference. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.
Electrochemical reduction and voltammetric determination of diloxanide furoate in non-aqueous medium
Resumo:
The electrochemical reduction of diloxanide furoate (DF) in acetonitrile on glassy carbon electrode was studied in this work. It was observed that DF is reduced after a reversible one-electron transfer followed by an irreversible chemical reaction, diagnosed as C-Cl bond cleavage. Its reduction was followed by linear (LSV), differential pulse (DPV) and square wave voltammetry (SWV). Analytical curves were obtained for DF determination using all the investigated voltammetric techniques. For LSV was obtained a linear range (LR) from 5.0 × 10-4 to 1.0 × 10-2 mol L-1, with detection limit (DL) of 1.5 × 10-4 mol L-1 and sensitivity (S) of 2.1 × 104 μA mol-1 L. The analytical parameters obtained by DPV were: LR = 5.0 × 10-4 to 2.2 × 10-3 mol L-1, DL = 7.8 × 10-5 mol L-1, S = 3.7 × 104 μA mol-1 L. For SWV were obtained a LR = 7.5 × 10-6 to 1.2 × 10 -3 mol L-1, DL = 5.5 × 10-6 mol L -1 and S = 2.8 × 105 μA mol-1 L. Thus, the SWV was the most sensible technique, which can be used for DF determination at low concentration levels. Statistics methods were used to evaluate the analytical procedure, where recovery around to 100% was obtained for all voltammetric techniques. Relative standard deviations were lower than 5.0% (N=5). The obtained t values evaluating all the three voltammetric methods were less than the tabulated ones, indicating that there are no evidences of systematic error. ©2005 Sociedade Brasileira de Química.
Resumo:
Copper Pentacyanonitrosylferrate (NCuNP) nanoparticles were prepared in formamide solvent. The material was characterized by Infrared (FTIR), X-Ray Diffraction (XRD) and Ultraviolet-Visible (UV-Vis) Spectroscopy. The Cyclic Voltammogram (CV) the modified graphite paste electrode with NCuNP exhibits two redox couples with (Eθ,)1 = 0.29 and (E θ,)2 = 0.86 V attribute at Cu(I)/Cu (II) and Fe(II)(CN)5NO/Fe(III)(CN) 5NO processes, respectively (KCl = 1.0 mol L-1; v = 20 mV s-1). The redox couple with (Eθ,)2 presents an electrocatalytic response for sulfite. The modified graphite paste electrode gives a linear response of 7.0 × 10-4 to 3.0 × 10-2 mol L-1 (r = 0.998), for sulfite determination with Detection Limit (DL) of 1.76 × 10-3 mol L-1 and an amperometric sensitivity of 3.38 mA/mol L-1 and relative standard desviations ± 3% (n=3). ©The Electrochemical Society.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A voltammetric method for the determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode (GCE) is proposed. The ethyl acetate present in the ethanol fuel was previously converted to acetohydroxamic acid via pretreatment with hydroxylamine chloride. The acetohydroxamic acid promptly reacted with the iron (III) present in the film, producing iron (III) acetohydroxamate, which presents a well-defined voltammetric peak current at -0.02 V. Optimization of the voltammetric parameters for the cyclic, linear sweep, square wave, and differential pulse modalities was carried out for this chemically-modified electrode. Square wave voltammetry afforded the best response for acetohydroxamic acid detection. The analytical curve for this species was linear from 9 to 100 μmol L 1 according to the following equation: ip (μA) = 0.27 + 2.55Cacetohydroxamic acid (μmol L 1), with linear correlation coefficient equal to 0.993. The technique presented limit of detection equal to 5.3 μmol L 1 and quantification limit of 17.6 μmol L 1. The proposed method was compared to the official method of ethyl acetate analysis (Gas Chromatography), and a satisfactory correlation was found between these techniques. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Pyrazinamide (Pyrazinecarboxamide-PZA) is a drug that is used to treatment tuberculosis. In the present work, the voltammetric behavior of PZA was studied using a screen-printed modified electrode (SPCE). The modified electrode was constructed using poly-histidine films, and it showed an electrocatalytic effect, thus promoting a decrease in PZA reduction potential and improving the voltammetric response. Cyclic voltammetry and electrochemical impedance spectroscopy techniques have been employed in order to elucidate of the electrodic reaction. The results allowed the proposal that in the PZA reduction, a further chemical reaction occurs that corresponds to a second-order process which is subsequent to the electrode reaction. In addition, a sensitive voltammetric method was developed, and it was successfully applied for PZA determination in human urine samples. The best response was found using SPCE modified with poly-histidine prepared by histidine monomer electropolymerization (SPCE/EPH). The electroanalytical performance of the SPCE/EPH was investigated by linear sweep (LSV), differential pulse (DPV), and square wave voltammetry (SWV). A linear relationship between peak current and PZA concentrations was obtained from 9.0 × 10-7 to 1.0 × 10-4 mol L-1 by using DPV. The limit of detection at 5.7 × 10 -7 mol L-1 was estimated, and a relative standard deviation of the 5.0 × 10-6 mol L-1 of PZA of 10 measurement was 3.7%. © 2012 Elsevier B.V. All rights reserved.