882 resultados para Vital force.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

While vital staining remains a cornerstone in the diagnosis of ocular disease and contact lens complications, there are many misconceptions regarding the properties of commonly used dyes by eye-care practitioners and what is and what is not corneal staining after instillation of sodium fluorescein. Similarly, the proper use and diagnostic utility of rose Bengal and lissamine green B, the other two ophthalmic dyes commonly used for assessing ocular complications, have similarly remained unclear. Due to the limitations of vital stains for definitive diagnosis, concomitant signs and symptoms in addition to a complete patient history are required. Over the past decade, there have been many reports of a type of corneal staining—often referred to as solution-induced corneal staining (SICS)—that is observed with the use of multipurpose solutions in combination with soft lenses, more specifically silicone hydrogel lenses. Some authors believe that SICS is a sign of lens/solution incompatibility; however, new research shows that SICS may be neither a measure of lens/solution biocompatibility nor ‘true’ corneal staining, as that observed in pathological situations. A large component of SICS may be a benign phenomenon, known as preservative-associated transient hyperfluorescence (PATH). There is a lack of correlated signs and/or symptoms with SICS/PATH. Several properties of SICS/PATH, such as appearance and duration, differentiate it from pathological corneal staining. This paper reviews the properties of vital stains, their use and limitations in assessment of the ocular surface, the aetiology of corneal staining, characteristics of SICS/PATH that differentiate it from pathological corneal staining and what the SICS/PATH phenomenon means for contact lens-wearing patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A response to: "Re: Putting vital stains in context" by Eric Papas & Lyndon Jones, published in the same issue of this journal. "There has been considerable discussion in recent times about the origins of solution-induced corneal staining (SICS) and I welcome this opportunity to further clarify some points raised in my paper1 in relation to certain issues highlighted by Drs Papas and Jones.2 Part of the difficulty in understanding these phenomena relates to the imprecise terminology used. For example, Drs Papas and Jones state ‘. . . SICS..."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A response to "Re: Putting vital stains in context" by Charles W McMonnies, published in the same issue of this journal. "I thank Professor McMonnies for his thoughtful comments,1 which rightly forcemeto more directly address the clinical ramifications of solution-induced corneal staining (SICS). I concur with his observation that determining whether the staining can be attributed to preservative-associated transient hyperfluorescence (PATH) or true pathology can be difficult in a typical clinical situation, perhaps requiring two visits in a single day. There is no easy answer to this dilemma..."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This special issue of the Journal of Learning Design, led by Jill Franz and Lindy Osborne, from the School of Design in the Creative Industries Faculty at the Queensland University of Technology, is grounded in Design Education. Its papers are drawn from differing fields of design: digital media, architecture, and environmental design. Each makes use of technologies in differing ways but all share the singular purpose of achieving enhanced learning outcomes from students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finite element method (FEM) relies on an approximate function to fit into a governing equation and minimizes the residual error in the integral sense in order to generate solutions for the boundary value problems (nodal solutions). Because of this FEM does not show simultaneous capacities for accurate displacement and force solutions at node and along an element, especially when under the element loads, which is of much ubiquity. If the displacement and force solutions are strictly confined to an element’s or member’s ends (nodal response), the structural safety along an element (member) is inevitably ignored, which can definitely hinder the design of a structure for both serviceability and ultimate limit states. Although the continuous element deflection and force solutions can be transformed into the discrete nodal solutions by mesh refinement of an element (member), this setback can also hinder the effective and efficient structural assessment as well as the whole-domain accuracy for structural safety of a structure. To this end, this paper presents an effective, robust, applicable and innovative approach to generate accurate nodal and element solutions in both fields of displacement and force, in which the salient and unique features embodies its versatility in applications for the structures to account for the accurate linear and second-order elastic displacement and force solutions along an element continuously as well as at its nodes. The significance of this paper is on shifting the nodal responses (robust global system analysis) into both nodal and element responses (sophisticated element formulation).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a Matlab toolbox for parametric identification of fluid-memory models associated with the radiation forces ships and offshore structures. Radiation forces are a key component of force-to-motion models used in simulators, motion control designs, and also for initial performance evaluation of wave-energy converters. The software described provides tools for preparing non-parmatric data and for identification with automatic model-order detection. The identification problem is considered in the frequency domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traction force microscopy (TFM) is commonly used to estimate cells’ traction forces from the deformation that they cause on their substrate. The accuracy of TFM highly depends on the computational methods used to measure the deformation of the substrate and estimate the forces, and also on the specifics of the experimental set-up. Computer simulations can be used to evaluate the effect of both the computational methods and the experimental set-up without the need to perform numerous experiments. Here, we present one such TFM simulator that addresses several limitations of the existing ones. As a proof of principle, we recreate a TFM experimental set-up, and apply a classic 2D TFM algorithm to recover the forces. In summary, our simulator provides a valuable tool to study the performance, refine experimentally, and guide the extraction of biological conclusions from TFM experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed to describe force or compound muscle action potential (CMAP) trace data collected in an electromyography study for motor unit number estimation (MUNE). Experimental data was collected using incre- mental stimulation at multiple durations. However, stimulus information, vital for alternate MUNE methods, is not comparable for multiple duration data and therefore previous methods of MUNE (Ridall et al., 2006, 2007) cannot be used with any reliability. Hypothesised ring combinations of motor units are mod- elled using a multiplicative factor and Bayesian P-spline formulation. The model describes the process for force and CMAP in a meaningful way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics describing the motion response of a marine structure in waves can be represented within a linear framework by the Cummins Equation. This equation contains a convolution term that represents the component of the radiation forces associated with fluid memory effects. Several methods have been proposed in the literature for the identification of parametric models to approximate and replace this convolution term. This replacement can facilitate the model implementation in simulators and the analysis of motion control designs. Some of the reported identification methods consider the problem in the time domain while other methods consider the problem in the frequency domain. This paper compares the application of these identification methods. The comparison is based not only on the quality of the estimated models, but also on the ease of implementation, ease of use, and the flexibility of the identification method to incorporate prior information related to the model being identified. To illustrate the main points arising from the comparison, a particular example based on the coupled vertical motion of a modern containership vessel is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical model is developed for the analysis of piston secondary motion. Based on this model, the slap force of a specific L6 diesel engine was compared when considering different boundary conditions, such as lubricating oil on cylinder liner, surface roughness, deformation of cylinder liner and piston skirt. It is concluded that it is necessary to consider the secondary motion of piston in the analysis of the inner excitation for an internal combustion engine. A more comprehensive consideration of the boundary condition (i.e., more close to the actual condition) will lead to a smaller maximum slap force, and among all boundary conditions considered in this paper, the structural deformation of the piston skirt and cylinder liner is the most influential factor. The theoretical model developed and findings obtained in this study will benefit the future analysis and design of advanced internal combustion engine structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper modifies and uses the semiparametric methods of Ichimura and Lee (1991) on standard cross-section data to decompose the effect of disability on labor force participation into a demand and a supply effect. It shows that straightforward use of Ichimura and Lee leads to meaningless results while imposing monotonicity on the unknown function leads to substantial results. The paper finds that supply effects dominate the demand effects of disability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess the impact of relaxed asthma recruitment standards adopted by the Australian Defence Force (ADF) in 2007. Methods A retrospective audit was conducted on clinical and administrative data for recruits, with and without mild asthma, in their first year of service. Results There was no evidence that mild asthmatics experienced worse outcomes than nonasthmatic recruits. Mild asthmatics had fewer illnesses and restricted duty days and were less costly compared to other recruits. There was no difference in the rate of discharge (attrition) between those with and without mild asthma. Conclusions The revised recruitment standards for asthma in the ADF have not resulted in unanticipated medical or administrative costs to the organisation. Health and administrative outcomes differed little between mild asthmatics and non-asthmatic recruits in their first twelve months of service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to determine the strain-rate-dependent mechanical behavior of living and fixed osteocytes and chondrocytes, in vitro. Firstly, Atomic Force Microscopy (AFM) was used to obtain the force-indentation curves of these single cells at four different strain-rates. These results were then employed in inverse finite element analysis (FEA) using Modified Standard neo-Hookean Solid (MSnHS) idealization of these cells to determine their mechanical properties. In addition, a FEA model with a newly developed spring element was employed to accurately simulate AFM evaluation in this study. We report that both cytoskeleton (CSK) and intracellular fluid govern the strain-rate-dependent mechanical property of living cells whereas intracellular fluid plays a predominant role on fixed cells’ behavior. In addition, through the comparisons, it can be concluded that osteocytes are stiffer than chondrocytes at all strain-rates tested indicating that the cells could be the biomarker of their tissue origin. Finally, we report that MSnHS is able to capture the strain-rate-dependent mechanical behavior of osteocyte and chondrocyte for both living and fixed cells. Therefore, we concluded that the MSnHS is a good model for exploration of mechanical deformation responses of single osteocytes and chondrocytes. This study could open a new avenue for analysis of mechanical behavior of osteocytes and chondrocytes as well as other similar types of cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper examines the knowledge of pedestrian movements, both in real scenarios, and from more recent years, in the virtual 4 simulation realm. Aiming to verify whether it is possible to learn from the study of virtual environments how people will behave in real 5 environments, it is vital to understand what is already known about behavior in real environments. Besides the walking interaction among 6 pedestrians, the interaction between pedestrians and the built environment in which they are walking also have greatest relevance. Force-based 7 models were compared with the other three major microscopic models of pedestrian simulation to demonstrate a more realistic and capable 8 heuristic approach is needed for the study of the dynamics of pedestrians.