987 resultados para VALIDATION INDEX


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Multiple Sclerosis International Quality Of Life (MusiQoL) questionnaire, a 31-item, multidimensional, self-administrated questionnaire that is available in 14 languages including Spanish, has been validated using a large international sample. We investigated the validity and reliability of the Spanish version of MusiQoL in Spain. METHODS: Consecutive patients with different types and severities of multiple sclerosis (MS) were recruited from 22 centres across Spain. All patients completed the MusiQoL questionnaire, the 36-Item Short Form (SF-36) health survey, and a symptoms checklist at baseline and 21 days later. External validity, internal consistency, reliability and reproducibility were tested. RESULTS: A total of 224 Spanish patients were evaluated. Dimensions of MusiQoL generally demonstrated a high internal consistency (Cronbach's alpha: 0.70-0.92 for all but two MusiQoL domain scores). External validity testing revealed that the MusiQoL index score correlated significantly with all SF-36 dimension scores (Pearson's correlation: 0.46-0.76), reproducibility was satisfactory (intraclass correlation coefficient: 0.60-0.91), acceptability was high, and the time taken to complete the 31-item questionnaire was reasonable (mean [standard deviation]: 9.8 [11.8] minutes). CONCLUSIONS: The Spanish version of the MusiQoL questionnaire appears to be a valid and reliable instrument for measuring quality of life in patients with MS in Spain and constitutes a useful instrument to measure health-related quality of life in the clinical setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this validation study was to assess the measurement properties of the CECA (Spanish acronym for the Specific Questionnaire for Condylomata Acuminata) in patients with anogenital condylomas. A total of 247 patients aged > 18 years completed the questionnaire on 2 occasions as well as the Dermatology Life Quality Index (DLQI). The CECA questionnaire showed good internal consistency (Cronbach's alpha values of 0.86 and 0.91 in the emotional and sexual activity dimensions) and good testretest reliability (intraclass correlation coefficient 0.76 emotional dimension, 0.82 sexual activity dimension). Patients with de novo lesions and those with more extensive lesions and larger number of warts showed poorer health-related quality of life. CECA and DLQI scores correlated moderately. Patients whose lesions cleared at follow-up or with a reduction of >or= 50% showed a better improvement of health-related quality of life. The CECA questionnaire is a valid, reliable and sensitive tool for the assessment of health-related quality of life in patients with anogenital warts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Several questionnaires have been used to measure health related quality of life (HRQoL) in patients with psoriasis, few have been adapted for use in Spain; none of them was developed specifically for the Spanish population. The purpose of the study was to validate and assess the sensitivity to change of a new questionnaire to measure HRQOL in patients with psoriasis (PSO-LIFE). METHODS Observational, prospective, multicenter study performed in centers around Spain. Patients with active or inactive psoriasis completed the PSO-LIFE together with other Dermatology Quality of Life Index (DLQI) and Psoriasis Disability Index (PDI). A control group of patients with urticaria or atopic dermatitis was also included. Internal consistency and test-retest reliability of the PSO-LIFE were assessed by calculating Cronbach's alpha and Intraclass Correlation Coefficient (ICC). Validity was assessed by examining factorial structure, the capacity to discriminate between groups, and correlations with other measures. Sensitivity to change was measured using effect sizes. RESULTS The final sample included for analysis consisted of 304 patients and 56 controls. Mean (SD) age of psoriasis patients was 45.3 (14.5) years compared to 38.8 (14) years for controls (p < 0.01). Cronbach's alpha for the PSO-LIFE was 0.95 and test-retest reliability using the ICC was 0.98. Factor analysis showed the questionnaire to be unidimensional. Mean (SD) PSO-LIFE scores differed between patients with psoriasis and controls (64.9 [22.5] vs 69.4 [17.3]; p < 0.05), between those with active and inactive disease (57.4 [20.4] vs 76.4 [20.6]; p < 0.01), and between those with visible and non-visible lesions (63.0 [21.9] vs. 74.8 [23.9]; p < 0.01). The correlation between PSO-LIFE and PASI scores was moderate (r = -0.43) while correlations with DLQI and PDI dimensions ranged from moderate to high (between 0.4 and 0.8). Effect size on the PSO-LIFE in patients reporting 'much improved' health status at study completion was 1.01 (large effect size). CONCLUSIONS The present results provide substantial support for the reliability, validity, and responsiveness of the PSO-LIFE questionnaire in the population for which it was designed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Outpatient Bleeding Risk Index (OBRI) and the Kuijer, RIETE and Kearon scores are clinical prognostic scores for bleeding in patients receiving oral anticoagulants for venous thromboembolism (VTE). We prospectively compared the performance of these scores in elderly patients with VTE. METHODS: In a prospective multicenter Swiss cohort study, we studied 663 patients aged ≥ 65 years with acute VTE. The outcome was a first major bleeding at 90 days. We classified patients into three categories of bleeding risk (low, intermediate and high) according to each score and dichotomized patients as high vs. low or intermediate risk. We calculated the area under the receiver-operating characteristic (ROC) curve, positive predictive values and likelihood ratios for each score. RESULTS: Overall, 28 out of 663 patients (4.2%, 95% confidence interval [CI] 2.8-6.0%) had a first major bleeding within 90 days. According to different scores, the rate of major bleeding varied from 1.9% to 2.1% in low-risk, from 4.2% to 5.0% in intermediate-risk and from 3.1% to 6.6% in high-risk patients. The discriminative power of the scores was poor to moderate, with areas under the ROC curve ranging from 0.49 to 0.60 (P = 0.21). The positive predictive values and positive likelihood ratios were low and varied from 3.1% to 6.6% and from 0.72 to 1.59, respectively. CONCLUSION: In elderly patients with VTE, existing bleeding risk scores do not have sufficient accuracy and power to discriminate between patients with VTE who are at a high risk of short-term major bleeding and those who are not.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The Bladder Cancer Index (BCI) is so far the only instrument applicable across all bladder cancer patients, independent of tumor infiltration or treatment applied. We developed a Spanish version of the BCI, and assessed its acceptability and metric properties. METHODS For the adaptation into Spanish we used the forward and back-translation method, expert panels, and cognitive debriefing patient interviews. For the assessment of metric properties we used data from 197 bladder cancer patients from a multi-center prospective study. The Spanish BCI and the SF-36 Health Survey were self-administered before and 12 months after treatment. Reliability was estimated by Cronbach's alpha. Construct validity was assessed through the multi-trait multi-method matrix. The magnitude of change was quantified by effect sizes to assess responsiveness. RESULTS Reliability coefficients ranged 0.75-0.97. The validity analysis confirmed moderate associations between the BCI function and bother subscales for urinary (r = 0.61) and bowel (r = 0.53) domains; conceptual independence among all BCI domains (r ≤ 0.3); and low correlation coefficients with the SF-36 scores, ranging 0.14-0.48. Among patients reporting global improvement at follow-up, pre-post treatment changes were statistically significant for the urinary domain and urinary bother subscale, with effect sizes of 0.38 and 0.53. CONCLUSIONS The Spanish BCI is well accepted, reliable, valid, responsive, and similar in performance compared to the original instrument. These findings support its use, both in Spanish and international studies, as a valuable and comprehensive tool for assessing quality of life across a wide range of bladder cancer patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Pulmonary Embolism Severity Index (PESI) estimates the risk of 30-day mortality in patients with acute pulmonary embolism (PE). We constructed a simplified version of the PESI. METHODS: The study retrospectively developed a simplified PESI clinical prediction rule for estimating the risk of 30-day mortality in a derivation cohort of Spanish outpatients. Simplified and original PESI performances were compared in the derivation cohort. The simplified PESI underwent retrospective external validation in an independent multinational cohort (Registro Informatizado de la Enfermedad Tromboembólica [RIETE] cohort) of outpatients. RESULTS: In the derivation data set, univariate logistic regression of the original 11 PESI variables led to the removal of variables that did not reach statistical significance and subsequently produced the simplified PESI that contained the variables of age, cancer, chronic cardiopulmonary disease, heart rate, systolic blood pressure, and oxyhemoglobin saturation levels. The prognostic accuracy of the original and simplified PESI scores did not differ (area under the curve, 0.75 [95% confidence interval (CI), 0.69-0.80]). The 305 of 995 patients (30.7%) who were classified as low risk by the simplified PESI had a 30-day mortality of 1.0% (95% CI, 0.0%-2.1%) compared with 10.9% (8.5%-13.2%) in the high-risk group. In the RIETE validation cohort, 2569 of 7106 patients (36.2%) who were classified as low risk by the simplified PESI had a 30-day mortality of 1.1% (95% CI, 0.7%-1.5%) compared with 8.9% (8.1%-9.8%) in the high-risk group. CONCLUSION: The simplified PESI has similar prognostic accuracy and clinical utility and greater ease of use compared with the original PESI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Aims: The international E EsAI s tudy g roup is currently d eveloping the first activity index ( EEsAI) specific for E osinophilic Esophagitis (EoE). G oal: T o develop, e valuate and validate the EEsAI. Methods: T he development c omprises three p hases: 1. Selection of c andidate items ( completed); 2. Evaluation of t he activity index i n a first patient cohort (in progress, p atient recruitment completed); and 3. Validation in a s econd EoE patient cohort. F ocus group interviews with patients were used in p hase 1 to g enerate patient r eported outcomes (PRO) according to g uidelines o f regulatory authorities (FDA a nd EMA), whereas the section of biologic items was developed by Delphi rounds o f international E oE experts from E urope and North America. Results: T he EEsAI has a modular c omposition to a ssess the following components o f EoE activity: p atient r eported outcomes, e ndoscopic activity, histologic activity, laboratory activity, a nd quality of l ife (QoL). Definitions for a ll aspects o f endoscopic and histologic appearance were e stablished by consensus r ounds a mong E oE experts. S ymptom a ssessment tools were c reated that t ake into account d ifferent food consistencies as w ell as f ood avoidance and specific processing strategies. The EEsAI i s currently e valuated in a cohort of a dult EoE patients since M arch 2 011 (patient recruitment completed). Conclusions: The EEsAI standardizes outcome assessment in EoE t rials. T he collaboration with i nternational E oE e xperts a s well as f ollowing o f the guidelines f rom regulatory authorities will lead to its wide applicability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the study was to validate the content of the dimensions that constituted nonadherence to treatment of arterial systemic hypertension. It was a methodological study of content validation. Initially an integrative review was conducted that demonstrated four dimensions of nonadherence: person, disease/treatment, health service, and environment. Definitions of these dimensions were evaluated by 17 professionals, who were specialists in the area, including: nurses, pharmacists and physicians. The Content Validity Index was calculated for each dimension (IVCi) and the set of the dimensions (IVCt), and the binomial test was conducted. The results permitted the validation of the dimensions with an IVCt of 0.88, demonstrating reasonable systematic comprehension of the phenomena of nonadherence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To validate an instrument to assess quality of mobile emergency pre-hospital care. METHOD A methodological study where 20 professionals gave their opinions on the items of the proposed instrument. The analysis was performed using Kappa test (K) and Content Validity Index (CVI), considering K> 0.80 and CVI ≥ 0.80. RESULTS Three items were excluded from the instrument: Professional Compensation; Job Satisfaction and Services Performed. Items that obtained adequate K and CVI indexes and remained in the instrument were: ambulance conservation status; physical structure; comfort in the ambulance; availability of material resources; user/staff safety; continuous learning; safety demonstrated by the team; access; welcoming; humanization; response time; costumer privacy; guidelines on care; relationship between professionals and costumers; opportunity for costumers to make complaints and multiprofessional conjunction/actuation. CONCLUSION The instrument to assess quality of care has been validated and may contribute to the evaluation of pre-hospital care in mobile emergency services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To translate and culturally adapt to Portuguese the Ferrans and Powers Quality of Life Index Spinal Cord Injury - Version III and characterize the sample in relation to sociodemographic and clinical aspects. METHOD A methodological study with view to cross-cultural adaptation, following the particular steps of this method: initial translation, translation synthesis, back-translation (translation back to the original language), review by a committee of judges and pretest of the final version. The pretest was carried out with 30 patients with spinal cord injury. RESULTS An index of 74 items divided into two parts (satisfaction/importance) was obtained. The criteria of semantic equivalence were evaluated as very adequate translation, higher than 87%, and vocabulary and were grammar higher than 86%. Idiomatic equivalence was higher than 74%, experimental greater than 78% and conceptual was greater than 70%. CONCLUSION After cross-cultural adaptation, the instrument proved semantic, idiomatic, experimental and conceptual adequacy, in addition to helping the evaluation of the quality of life of people with spinal cord injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract OBJECTIVE To describe the stages of construction and validation of an instrument in order to analyze the adherence to best care practices during labour and birth. METHOD Methodological research, carried out in three steps: construction of dimensions and items, face and content validity and semantic analysis of the items. RESULTS The face and content validity was carried out by 10 judges working in healthcare, teaching and research. Items with Content Validity Index (CVI) ≥ 0.9 were kept in full or undergone revisions as suggested by the judges. Semantic analysis, performed twice, indicated that there was no difficulty in understanding the items. CONCLUSION The instrument with three dimensions (organization of healthcare network to pregnancy and childbirth, evidence-based practices and work processes) followed the steps recommended in the literature, concluded with 50 items and total CVI of 0.98.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract OBJECTIVE To analyze the evidences of construct validity of the Katz Index for the retrospective assessment of activities of daily living (ADL) by informants, to assist neuropathological studies in the elderly. METHOD A cross-sectional study analyzed the functional ability of ADL measure by the Katz Index, of 650 cases randomly selected from the Brazilian Brain Bank of the Ageing Brain Study Group (BBBABSG) database. Sample was divided in two subsamples for the analysis (N=325, each) and then stratified according to cognitive decline assessed by the Clinical Dementia Rating Scale (CDR). Factor analyses with calculations of internal consistency and invariance were performed. RESULTS Factor analysis evidenced a unidimensional instrument with optimal internal consistency, in all subgroups. Goodness of fit indices were obtained after two treatments of covariance, indicating adequacy of the scale for assessing ADL by informants. The scale is invariant to cognitive decline meaning that it can be used for subjects with or without cognitive impairment. CONCLUSION Katz Index is valid for the retrospective assessment of basic ADL by informants, with optimal reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract OBJECTIVE Developing and validating an instrument to evaluate the playfulness of games in health education contexts. METHODOLOGY A methodological, exploratory and descriptive research, developed in two stages: 1. Application of an open questionnaire to 50 graduate students, with content analysis of the answers and calculation of Kappa coefficient for defining items; 2. Procedures for construction of scales, with content validation by judges and analysis of the consensus estimate byContent Validity Index(CVI). RESULTS 53 items regarding the restless character of the games in the dimensions of playfulness, the formative components of learning and the profiles of the players. CONCLUSION Ludicity can be assessed by validated items related to the degree of involvement, immersion and reinvention of the subjects in the game along with the dynamics and playability of the game.