912 resultados para The performance of Christian and pagan storyworlds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a theoretical framework for determining the short- and long-run effects of infrastructure. While the short-run effects have been the focus of most previous studies, here we derive long-run elasticities by taking into account the adjustment of quasi-fixed inputs to their optimum levels. By considering the impact of infrastructure on private investment decisions, we observe how, apart from the direct effect on costs in the short-run, infrastructure exerts an indirect source of influence in the long-run through their effect on private capital. The model is applied to manufacturing industries in the Spanish regions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a theoretical framework for determining the short- and long-run effects of infrastructure. While the short-run effects have been the focus of most previous studies, here we derive long-run elasticities by taking into account the adjustment of quasi-fixed inputs to their optimum levels. By considering the impact of infrastructure on private investment decisions, we observe how, apart from the direct effect on costs in the short-run, infrastructure exerts an indirect source of influence in the long-run through their effect on private capital. The model is applied to manufacturing industries in the Spanish regions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland. METHODS: IRT was measured using AutoDELFIA Neonatal IRT-Kit in stored NBS cards. RESULTS: Between 2006 and 2009, 66 children with CF were reported, 4 of which were excluded for various reasons (born in another country, NBS at 6 months, no informed consent). 98% (61/62) had significantly higher IRT compared to matched control group. There was one false negative IRT result in an asymptomatic child with atypical CF (normal pancreatic function and sweat test). CONCLUSIONS: All children but one with atypical CF would have been detected with the planned two step protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) The book of Hebrews has often been the Cinderella of the New Testament, overlooked and marginalized; and yet it is one of the most interesting and theologically significant books in the New Testament. A Cloud of Witness examines the theology of the book in the light of its ancient historical context. There are chapters devoted to the structure of Hebrews, the person of Jesus Christ, Hebrews within the context of Second Temple Judaism and the Greco-Roman empire and the role of Hebrews in early Christian thought.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lihasikojen E-vitamiinin tarve ruokittaessa vastapuidulla ohralla ja rehuun lisätyn E-vitamiinin vaikutus lihan pakastussäilyvyyteen ja syöntilaatuun

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selostus: Ureoidun oljen soveltuvuus risteytysemojen talviruokintaan kahdella eri ruokintatasolla

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Régner, Escribe, and Dupeyrat (2007) recently demonstrated that not only performance-approach and performance-avoidance goals (respectively, the desire to outperform others and not to be outperformed by others) but also mastery goals (the desire to acquire knowledge) were related to social comparison orientation (SCO, the tendency to search for social comparison information). In the present article, the possibility of a link between mastery goals and social comparison that depends on the level of performance-approach goals-a possibility supported by a multiple-goal perspective-was tested by examining the interaction effect between mastery and performance-approach goals. This is an important endeavor, as educational settings are rarely free from performance-approach goals, even when mastery goals are promoted. In Study 1, we tested self-set achievement goals (mastery, performance-approach, and performance-avoidance goals) as predictors of SCO; the interaction between mastery goals and performance-approach goals indicated that the higher the performance-approach goal endorsement, the stronger the link between mastery goals and SCO. In Study 2, we manipulated goal conditions; mastery goals predicted interest in social comparison in the performance-approach goal condition only. Results are discussed in terms of the importance of multiple-goal pursuit in academic settings. (PsycINFO Database Record (c) 2009 APA, all rights reserved)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selostus: Sisäruokintakauden energiamäärien vaikutus risteytysemolehmien tuotantoon

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comentaris referits a l'article següent: K. J. Vinoy, J. K. Abraham, and V. K. Varadan, “On the relationshipbetween fractal dimension and the performance of multi-resonant dipoleantennas using Koch curves,” IEEE Transactions on Antennas and Propagation, 2003, vol. 51, p. 2296–2303.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selostus: Tasaruokinnan ja vaihtoehtoisten rehujen soveltuvuus emolehmien talvikauden ruokintaan

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.