966 resultados para Swimming pools -- Air conditioning
Resumo:
Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.
Resumo:
Understanding the impact of training sessions on the immune response is crucial for the adequate periodization of training, to prevent both a negative influence on health and a performance impairment of the athlete. This study evaluated acute systemic immune cell changes in response to an actual swimming session, during a 24-h recovery period, controlling for sex, menstrual cycle phases, maturity, and age group. Competitive swimmers (30 females, 15 ± 1.3 years old; and 35 males, 16.5 ± 2.1 years old) performed a high-intensity training session. Blood samples were collected before, immediately after, 2 h after, and 24 h after exercise. Standard procedures for the assessment of leukogram by automated counting (Coulter LH 750, Beckman) and lymphocytes subsets by flow cytometry (FACS Calibur BD, Biosciences) were used. Subjects were grouped according to competitive age groups and pubertal Tanner stages. Menstrual cycle phase was monitored. The training session induced neutrophilia, lymphopenia, and a low eosinophil count, lasting for at least 2 h, independent of sex and maturity. At 24 h postexercise, the acquired immunity of juniors (15-17 years old), expressed by total lymphocytes and total T lymphocytes (CD3+), was not fully recovered. This should be accounted for when planning a weekly training program. The observed lymphopenia suggests a lower immune surveillance at the end of the session that may depress the immunity of athletes, highlighting the need for extra care when athletes are exposed to aggressive environmental agents such as swimming pools
Resumo:
Mestrado em Engenharia Química
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
A procura de piscinas para a prática de atividades desportivas, recreativas e/ou terapêuticas tem sofrido um aumento gradual ao longo do tempo. No entanto, nas piscinas existem vários perigos associados à sua utilização. Relativamente aos perigos químicos, a utilização de desinfetantes à base de cloro, bromo ou compostos derivados vai, por um lado, inativar microrganismos patogénicos mas, por outro, dar origem a subprodutos ao reagir com compostos orgânicos presentes na água. Os trihalometanos são um exemplo de subprodutos que se podem formar e, entre os compostos principais, estão o clorofórmio (TCM), bromodiclorometano (BDCM), clorodibromometano (CDBM) e bromofórmio (TBM). Este trabalho teve como objetivo o desenvolvimento de uma metodologia analítica para a determinação de trihalometanos em água e ar de piscinas e a sua aplicação a um conjunto de amostras. Para a análise dos compostos, foi utilizada a microextração em fase sólida no espaço de cabeça (HS-SPME) com posterior quantificação dos compostos por cromatografia gasosa com detetor de captura eletrónica (GC-ECD). Foi realizada uma otimização das condições de extração dos compostos em estudo em amostras de água, através da realização de dois planeamentos experimentais. As condições ótimas são assim obtidas para uma temperatura de extração de 45ºC, um tempo de extração de 25 min e um tempo de dessorção de 5 min. Foram analisadas amostras de águas de piscina cedidas pelo Centro de Estudos de Águas, sendo avaliada a aplicação da técnica HS-SPME e o efeito de matriz. O modo como se manuseiam as soluções que contêm os compostos em estudo influencia os resultados devido ao facto destes serem bastante voláteis. Concluiu-se também que existe efeito de matriz, logo a concentração das amostras deverá ser determinada através do método de adição de padrão. A caraterização da água de piscinas interiores permitiu conhecer a concentração de trihalometanos (THMs). Foram obtidas concentrações de TCM entre 4,5 e 406,5 μg/L sendo que apenas 4 das 27 amostras analisadas ultrapassam o valor limite imposto pelo Decreto-Lei nº306/2007 (100 μg/L) no que diz respeito a águas de consumo humano e que é normalmente utilizado como valor indicativo para a qualidade das águas de piscina. Relativamente à concentração obtida no ar de uma piscina interior, foi detetada uma concentração média de 224 μg/m3 de TCM, valor muito abaixo dos 10000 μg/m3 impostos pelo Decreto-lei nº24/2012, como valor limite para exposição profissional a agentes químicos.
Resumo:
RESUMO - Os trabalhadores dos ginásios com piscinas apresentam maior prevalência de lesões fúngicas, como a Tinea pedis e a onicomicose, devido às características intrínsecas da sua actividade profissional, pois apresentam mais horas por dia de exposição à contaminação fúngica das superfícies. Esta situação verifica-se não só por serem os que mais frequentam os locais possíveis de estarem contaminados, como é o caso de balneários, vestiários e zona envolvente às piscinas, mas também porque algumas das actividades desenvolvidas são realizadas com os pés descalços. Além disso, a utilização de roupa sintética e de calçado ocluso, que retêm a sudação excessiva, favorece o desenvolvimento fúngico. Constituiu objectivo deste trabalho conhecer o risco de infecção e/ou lesão (Tinea pedis e onicomicose) nos trabalhadores dos ginásios com piscina e a sua eventual relação com a exposição à contaminação fúngica (ar e superfícies) dos locais de trabalho. Foram descritas as variáveis ambientais e biológicas que influenciam a infecção e/ou lesão fúngica em ambiente profissional e exploradas eventuais associações entre essas mesmas variáveis. Foram também conhecidas as diferenças da contaminação fúngica das superfícies entre as duas principais estações do ano (Verão e Inverno) e entre antes e depois da lavagem e desinfecção. O estudo realizado possui uma componente transversal, em que se pretendeu descrever os fenómenos ambientais e biológicos da contaminação fúngica em ambiente profissional e explorar eventuais associações entre variáveis; uma componente longitudinal, em que foram conhecidas as diferenças sazonais da contaminação fúngica das superfícies; e, ainda, uma componente quase experimental, em que foi analisada a distribuição fúngica nas superfícies antes e depois da lavagem e desinfecção. Na vertente transversal foi considerada uma amostra de 10 ginásios com piscina e outra amostra de, pelo menos, 10 profissionais de cada estabelecimento, perfazendo um total de 124 trabalhadores (75 Homens - 60,48% e 49 Mulheres - 39,52%). Foram realizadas 258 colheitas biológicas aos pés dos trabalhadores, efectuada a avaliação ambiental da contaminação fúngica dos estabelecimentos através de 50 colheitas de amostras de ar e 120 colheitas de amostras de superfícies (60 antes e 60 depois da lavagem e desinfecção) e efectuados os respectivos processamento laboratorial e identificação fúngica. Foram também avaliadas as variáveis ambientais temperatura, humidade relativa e velocidade do ar, preenchidas 10 grelhas de observação, com o objectivo de efectuar o registo de informação sobre as variáveis que xx influenciam a exposição ocupacional às espécies fúngicas e, ainda, completadas 124 grelhas de observação inerentes à colheita de material biológico, de modo a realizar o registo dos profissionais com lesão e outras informações pertinentes para a análise laboratorial. Todos os 124 trabalhadores responderam a um questionário, em simultâneo à realização das colheitas biológicas, de modo a conhecer algumas das variáveis individuais e profissionais com pertinência para o presente estudo. Num dos estabelecimentos, foram também estudadas as diferenças da contaminação fúngica das superfícies entre antes e depois da lavagem e desinfecção e, ainda, entre as duas estações do ano (Verão e Inverno). Nesse estabelecimento, foram realizadas 36 colheitas de superfícies antes e 36 colheitas depois da lavagem e desinfecção, em 6 dias diferentes da semana, durante 6 semanas sequenciais em cada estação do ano, completando um total de 72 colheitas de superfícies. Foi ainda criado e aplicado um método para estabelecer um padrão de exposição profissional a fungos nas superfícies, de modo a permitir definir níveis semi-quantitativos de estimação do risco de infecção fúngica dos trabalhadores dos ginásios com piscinas. Para o critério da Gravidade, considerou-se que a gravidade da contaminação e, consequentemente, da possível lesão, está intimamente relacionada com a espécie fúngica envolvida. Foram calculadas as médias da contaminação fúngica por cada estabelecimento antes da lavagem e desinfecção, de modo a estabelecer os níveis de Frequência e, em relação à Exposição, foram estabelecidos intervalos para agrupar as horas semanais de trabalho. Dos 124 trabalhadores que participaram no estudo, 58 (46,8%) possuíam lesões visíveis. Nesses 58, as Leveduras foram as mais isoladas (41,4%), seguidas dos Dermatófitos (24,1%) e de Fungos Filamentosos Não Dermatófitos (6,9%). Candida parapsilosis e Rhodotorula sp. foram as Leveduras mais frequentemente isoladas (20,2%); no caso dos Dermatófitos, Trichophyton rubrum foi a espécie mais frequente (55,5%) e, relativamente aos Fungos Filamentosos Não Dermatófitos, Penicillium sp. foi o mais isolado (15,6%), seguido do género Fusarium (12,5%). No que concerne à contaminação fúngica das superfícies, 37 fungos filamentosos foram isolados. Fusarium foi o género mais frequente, antes e depois da lavagem e desinfecção (19,1% - 17,2%). Em relação aos fungos leveduriformes, 12 leveduras diferentes foram identificadas, tendo sido os géneros Cryptococcus (40,6%) e Candida (49,3%) os mais frequentes antes e depois da lavagem e desinfecção, respectivamente. Em relação à contaminação fúngica do ar, foram identificados 25 fungos filamentosos diferentes, em que os 3 géneros mais frequentemente isolados foram Cladosporium (36,6%), Penicillium (19,0%) e Aspergillus (10,2%). Relativamente às leveduras, foi identificado o género xxi Rhodotorula (87,5%) e as espécies Trichosporon mucoides e Cryptococcus unigutulattus (12,5%). Verificou-se associação, ao nível de significância de 5%, entre lesão visível e horas semanais e entre lesão visível e tempo de profissão, comprovando a influência da duração da exposição ao factor de risco (contaminação fúngica do ambiente profissional), para a presença de lesão visível nos trabalhadores expostos (Tinea pedis e onicomicose), ficando demonstrada a relação entre a exposição ao factor de risco em estudo – exposição profissional a fungos – com os efeitos para a saúde. As variáveis ambientais avaliadas (temperatura, humidade relativa e velocidade do ar) não influenciaram a contaminação fúngica do ar e das superfícies, não tendo sido evidenciada nenhuma relação estatisticamente significativa (p>0,05). Contudo, verificou-se influência do número de ocupantes que frequentaram cada um dos estabelecimentos nas médias das unidades formadoras de colónias por metro quadrado nas superfícies antes da lavagem e desinfecção. Não se verificou correlação entre os resultados quantitativos da contaminação fúngica do ar e a das superfícies dos 10 estabelecimentos monitorizados. No entanto, verificaram-se diferenças significativas, ao nível de significância de 10%, entre a contaminação fúngica das superfícies e a contaminação fúngica do ar (p<0,1), tendo-se constatado que apesar de 50% dos valores mais baixos terem sido superiores na contaminação fúngica do ar, a contaminação fúngica das superfícies apresentou-se com maior variabilidade quantitativa. Em relação às diferenças significativas na contaminação fúngica das superfícies nos 10 estabelecimentos entre antes e depois da lavagem e desinfecção, apenas se verificou redução significativa (p<0,05) da contaminação fúngica depois da lavagem e desinfecção nos balneários e vestiários masculinos em relação aos fungos leveduriformes. No estabelecimento seleccionado, verificou-se que a relação entre a contaminação fúngica e a temperatura e humidade relativa não foi significativa (p>0,05) em ambas as estações do ano e também não se constatou influência dos ocupantes nos valores médios das unidades formadoras de colónias por metro quadrado das superfícies antes da lavagem e desinfecção em ambas as estações de ano. Em quase todas as situações em que se verificaram diferenças significativas entre as duas estações do ano, verificou-se um aumento das unidades formadoras de colónias por metro quadrado no Inverno, com excepção do total das unidades formadoras de colónias por metro quadrado antes da lavagem e desinfecção nos balneários e vestiários masculinos em que se verificou aumento no Verão. Constatou-se também que apenas ocorreu redução da xxii contaminação fúngica depois da lavagem e desinfecção nas escadas de acesso no Inverno e nos balneários e vestiários masculinos no Verão. Com a aplicação do método para estabelecer um padrão de exposição profissional a fungos nas superfícies obteve-se, nos 10 estabelecimentos, com Nível de Risco Mínimo 65 locais (54,2%), com Nível de Risco Médio 23 locais (19,2%) e com Nível de Risco Elevado 32 locais (26,6%). Próximo do jacuzzi e junto ao tanque foram os locais com mais classificações de Nível de Risco Elevado. No estabelecimento seleccionado verificou-se que, no Verão, depois da lavagem e desinfecção, ocorreu um maior número de locais classificados no Nível de Risco Elevado e, no Inverno, constatou-se a situação inversa, tendo sido observado maior número de locais com Nível de Risco Elevado antes da lavagem e desinfecção. Junto ao tanque e nas escadas de acesso à zona envolvente ao jacuzzi e tanque foram os locais com mais classificações de Nível de Risco Elevado, no Verão e no Inverno. Foram isolados nas superfícies fungos comuns aos isolados nos trabalhadores. Antes da lavagem e desinfecção, 30,3% dos fungos foram isolados nas superfícies e nos trabalhadores e depois desses procedimentos 45,5% dos fungos foram também isolados comummente. As Leveduras foram as mais isoladas comummente e as que se verificaram mais frequentes antes e depois da lavagem e desinfecção da superfícies e, também, nos resultados das colheitas biológicas realizadas aos trabalhadores, foram o género Rhodotorula e a espécie Candida parapsilosis, permitindo confirmar que a infecção fúngica dos trabalhadores está relacionada com a contaminação fúngica das superfícies. Concluiu-se que é necessária a intervenção em Saúde Ocupacional no âmbito da vigilância ambiental e da vigilância da saúde, com o intuito de diminuir a prevalência das infecções fúngicas. Para a prossecução desse objectivo, sugere-se a implementação de medidas preventivas, nomeadamente: o controlo da contaminação fúngica das superfícies mediante procedimentos de lavagem e desinfecção eficazes, de modo a minimizar a contaminação fúngica das superfícies; a identificação precoce da infecção através da realização de colheitas biológicas periódicas aos trabalhadores, inseridas num protocolo de vigilância da saúde; e, ainda, a sensibilização para a aplicação de medidas de higiene pessoal e o tratamento das patologias. A aplicação do método criado para estabelecer um padrão de exposição profissional a fungos nas superfícies servirá não só para a estimação do risco de infecção fúngica dos trabalhadores de ginásios com piscinas, mas também para facilitar o estabelecimento de valores fúngicos de referência, a implementação de medidas correctivas adequadas e imediatas e, ainda, a prevenção de infecções fúngicas, não só nos ginásios com piscina, mas também noutros contextos profissionais. ------------ SUMMARY - Gyms with swimming pools workers have higher prevalence of fungal injuries, such as Tinea pedis and onychomycosis. This is due to their work intrinsic characteristics, since they have more hours per day of exposure to surfaces fungal contamination. This occurs not only because they attend sites most likely to be contaminated, such as showers, changing rooms and pool surrounding area, but also because some of the activities are done barefoot. Furthermore, synthetic clothing and occluded footwear use, which retain the excessive sweating, promotes fungal development. The aim of this study was to know gymnasiums with swimming pool workers infection and/or injury (Tinea pedis and onychomycosis) risk, and its possible relationship with exposure to workplace fungal contamination (air and surfaces). This study describes environmental and biological variables that influence infection and/or fungal injury in a professional setting and explored possible associations between these variables. Differences in surfaces fungal contamination between the two main seasons (summer and winter), as well between before and after cleaning and disinfection were known. It was developed a study with an cross-sectional perspective, that aimed to describe the biological and environmental phenomena of fungal contamination in a professional environment and explore possible associations between variables; an longitudinal perspective in which were known surfaces fungal contamination seasonal differences; and also with an almost experimental perspective that analyzed surfaces fungal distribution before and after cleaning and disinfection. The cross-sectional perspective comprised 10 gyms with swimming pool sample, and another sample of, at least, 10 professionals in each establishment totalling 124 workers (75 men – 60,48%, and 49 women – 39,52%). Were performed 258 biological samples at workers feet, environmental fungal contamination evaluation from the establishments through 50 air samples and 120 surfaces samples (60 before and 60 after cleaning and disinfection) and conducted their laboratory processing and fungal identification. Were also evaluated environmental variables, such as temperature, relative humidity and air velocity completed 10 observation grids, in order to obtain data about variables that affect occupational exposure to fungal species, and also completed 124 observation grids inherent to biological material collection, in order to know the professionals with injury and other relevant information for laboratory analysis. All 124 workers answered to a questionnaire at the same time that occur biological samples collection, in order to xxv obtain information about some of the individual and professional variables with relevance to this study. In one of the establishments were also studied differences concerning surfaces fungal contamination between before and after cleaning and disinfection, and also between two main seasons (summer and winter). In this setting, there were performed 36 surfaces samples before and 36 surfaces samples after cleaning and disinfection on 6 different week days for 6 sequential weeks in each season, totalling 72 surfaces samples. It was also created and implemented a method to establish a pattern for surfaces fungal occupational exposure, in order to help define semi-quantitative levels estimation to fungal infection risk in gyms with swimming pools workers. For Gravity criterion it was considered that contamination severity and, thus, the possible injury are closely related to implicate fungal species. Was calculated fungal contamination average by each establishment prior cleaning and disinfection, in order to establish Frequency levels. Regarding Exposure, were established weekly hours group intervals spent in professional activity. From the 124 professionals tested, 58 (46,8%) had visible injuries. In the 58 workers, Yeasts were the most isolated (41,4%), followed by Dermatophytes (24,1%) and Other Filamentous Fungi Besides Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. were the most frequently isolated Yeasts (20,2% for each), from Dermatophytes, Trichophyton rubrum was the most frequently isolated species (55,5%) and from Other Filamentous Fungi Besides Dermatophytes, Penicillium sp. was the most frequent (15,6%), followed by Fusarium genera (12,5%). Regarding surfaces fungal contamination, 37 filamentous fungi were isolated. Fusarium genera was the most frequent, before and after cleaning and disinfection (19,1% - 17,2%). Considering yeasts, 12 different yeasts were identified, being Cryptococcus (40,6%) and Candida (49,3%) genera the more frequent before and after cleaning and disinfection, respectively. In relation to air fungal contamination, 25 different filamentous fungi were identified and the 3 most frequently isolated genera were Cladosporium (36,6%), Penicillium (19,0%) and Aspergillus (10,2%). For yeasts, were identified Rhodotorula genera (87,5%), and also the species Trichosporon mucoides and Cryptococcus unigutulattus (12,5%). Was found association with 5% significance level, between visible injury and weekly hours and between visible injury and occupation time, confirming exposure duration influence to risk factor (work environment fungal contamination) for the visible injury presence in exposed workers (Tinea pedis and onychomycosis), being confirmed the relation between the study exposure risk - occupational exposure to fungi - with health effects. xxvi Environmental variables evaluated (temperature, relative humidity and air velocity) did not affect air and surfaces fungal contamination and wasn’t found no statistically significant relation (p>0,05). However, there was evidence that occupant’s number influence surfaces colony forming units mean per square meter before cleaning and disinfection. There was no correlation between quantitative data from air fungal contamination and surfaces fungal contamination from the 10 establishments monitored. However, there were significant differences with 10% significance level, between surfaces and air fungal contamination (p<0,1), and despite 50% of the lowest rates were higher in air fungal contamination, it was found that surfaces fungal contamination had more quantitative variability. Regarding differences from the 10 establishments surfaces fungal contamination, between before and after cleaning and disinfection, there was only a significant reduction (p<0,05) in fungal contamination after cleaning and disinfection in male changing rooms for yeasts. In the selected establishment, it was found that relation between fungal contamination and temperature and relative humidity was not significant (p>0,05) in both seasons, and also there wasn’t no influence observed from occupants in surfaces colony forming units mean per square meters before cleaning and disinfection in both seasons. In almost all situations where significant differences between the two seasons were shown, there was a colony-forming units per square meter increase in winter. There was an exception in total colony forming units per square meter before cleaning and disinfection in male changing room’s exception, where there was an increase in summer. Furthermore, was found that only occur a reduction in fungal contamination after cleaning and disinfection, on access stairs in winter, as well as in male changing rooms in summer. With application from the method to establish pattern for surfaces fungal occupational exposure, it was obtained, in the 10 establishments, 65 sites with Low Risk Level (54,2%), 23 sites with Average Risk Level (19,2%) and 32 sites with High Risk Level (26,6%). Near swimming pool and jacuzzi were the places with more High Risk Level classifications. In the selected establishment, was found that in the summer, after cleaning and disinfection, there were a greater number of sites classified as High Risk Level, and in winter it was found the opposite situation, being noted more places with High Risk Level before cleaning and disinfection. Next to swimming pool and access stairs to swimming pool and jacuzzi were the places with more High Risk Level classifications in Summer and Winter. Were isolated common fungi in surfaces and in workers. Prior to cleaning and disinfection 30,3% of fungi were isolated on surfaces and workers, and after 45,5% of fungi were also xxvii commonly isolated. The Yeasts were the most commonly isolated and the most frequent before and after surfaces cleaning and disinfection, and also in workers biological samples, were Rhodotorula genera and Candida parapsilosis, allowing confirming that workers fungal infection is related with surfaces fungal contamination. It was concluded that Occupational Health intervention it is necessary, in environmental monitoring and health surveillance perspective, in order to reduce fungal infections prevalence. To achieve this objective, preventive measures implementation it’s recommended, including: surfaces fungal contamination control, through effective cleaning and disinfecting in order to minimize surfaces fungal contamination; early infection identification by performing periodic biological sampling from workers, included in a health surveillance protocol; and also personal hygiene and diseases treatment awareness. Application of the created method to establish pattern for surfaces fungal occupational exposure, will be useful not only for estimating workers from gymnasiums with swimming pools fungal infection risk, but also to facilitate fungal reference values stipulation, effective and corrective measures implementation, and also, fungal infections prevention, not only in gymnasiums with swimming pool, but also in other professional settings.----------------- RÉSUMÉ - Les travailleurs des gymnases avec des piscines présentent souvent des infections fongiques, telles que Tinea pedis et aussi des onychomycoses, dues à leur activité professionnel, parce qu’ils restent plus longtemps tout prés des surfaces avec une certaine contamination fongique. Toute cette situation est due non seulement parce qu’ils sont ceux qui fréquentent plus souvent les places plus contaminées: des balnéaires, des vestiaires et des zones autour des piscines, mais aussi ils réalisent des activités aux pieds nus ou avec des chaussures très fermés et encore quelques fois avec des vêtements synthétiques. Tout cela emmène à une grande sudation ce qui aidera au développement fongique. Un objective de ce travaille a été connaître le risque d’infection et/ou présence de lésion (Tinea pedis et des onychomycoses) dans les travailleurs des gymnases avec des piscines et leur éventuel rapport avec l’exposition à la contamination fongique (de l’air et des surfaces) dans leurs locaux de travaille. On a décrit aussi des variables d’environnement et biologiques qui ont une certaine influence dans les infections fongiques dans tout l’environnement professionnel et aussi approfondir des éventuels associations entre ces même variables. On a encore reconnu des différences de la contamination fongique avant et après des lavages et désinfection de ces surfaces. Aussi on a trouvé des différences de contamination en Été et en Hiver. Cet étude a un composante transversale, en visant la description des phénomènes de contamination fongique biologique et de l'environnement dans un environnement professionnel et l’étude des associations possibles entre les variables; une composante longitudinale dans laquelle ils étaient connus comme des variations saisonnières de la contamination fongique des surfaces, et même; un quasi-composante expérimentale, où elle a examiné la répartition des champignons surfaces avant et après le lavage et la désinfection. Dans la composante transversale on été considérés 1 échantillons de 10 gymnases avec des piscines et un autre échantillon de au moins 10 professionnels de chaque établissement dans un total 124 travailleurs (75 hommes - 60,48% et 49 femmes - 39,52%). On a réalisé 258 prélèvements aux pieds des travailleurs et on a effectué en simultané la validation par contamination fongique de l’environnement par 50 prélèvements de l’air et par 120 prélèvements de surfaces (60 avant et 60 après des lavages et des désinfections) et on a effectué leur traitement en laboratoire et l’identification fongique. On a fait aussi l’évaluation des variables de l’environnement, la température, l’humidité relative et la vitesse de l’air. On a remplie 10 tableaux xxix d’observation, avec l’objective d’obtenir des informations sur les variables qu’influenceront l’exposition occupationnel aux souches fongiques, et encore 124 tableaux d’observation liée au prélèvement du matériel biologique, pour réaliser le registre des professionnels avec des lésions et des autres informations pertinentes pour une analyse laboratoire. Tous ces 124 travailleurs ont rempli un questionnaire au même temps que les prélèvements biologiques, afin de connaître quelques variables individuels et professionnels importants pour cet étude. Dans un des établissements on a aussi étudié les différences fongiques des surfaces parmi avant et après les lavages et de la désinfection et encore parmi l’Été et l’Hiver. Dans ce même établissement on a réalisé 36 prélèvements des surfaces avant et 36 après des lavages et de la désinfection, pendant 6 jours différents de la semaine, pendant 6 semaines en chaque saison de l’année, dans un total de 72 prélèvements des surfaces. On a encore crié et appliqué une méthode pour établir un standard d’exposition professionnelle au fungi sur les surfaces, afin de permettre la définition des niveaux semi quantitative d’estimation des risques d’infection fongique des travailleurs des gymnases avec des piscines. Pour le critère de Gravité, il a été considéré que la gravité de la contamination, et donc les possibles dommages, est étroitement liée aux espèces fongiques impliquées. Nous avons calculé la moyenne de la contamination fongique par chaque établissement avant le lavage et la désinfection afin d'établir les niveaux de Fréquence et, par rapport à l'Exposition, ont été crées pour regrouper les intervalles d'heures hebdomadaires consacrées à l'activité professionnelle en question. Sur les 124 travailleurs qui ont participé à l'étude, 58 (46,8%) avaient des lésions visibles. Parmi ces 58, les Levures ont été les plus isolées (41,4%), suivis par des Dermatophytes (24,1%) et des Filamenteux Non Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. ont été les Levures les plus fréquemment isolées (20,2%); dans le cas des Dermatophytes, Trichophyton rubrum est le plus fréquent (55,5%) et pour les Filamenteux Non Dermatophytes, Penicillium sp. a été le plus isolé (15,6%), suivi par Fusarium sp. (12,5%). En ce qui concerne la contamination fongique des surfaces, 37 champignons filamenteux ont été isolés. Le genre Fusarium est le plus fréquent avant et après le lavage et la désinfection (19,1% - 17,2%). Pour la levure, 12 levures différentes ont été identifiées, ayant été Cryptococcus sp. (40,6%) et Candida sp. (49,3%) les plus fréquents avant et après le lavage et la désinfection, respectivement. En ce qui concerne la contamination fongique de l'air, on a identifié 25 différents champignons filamenteux, où les 3 genres les plus fréquemment isolés étaient Cladosporium (36,6%), Penicillium (19,0%) et Aspergillus (10,2%). Pour les levures, il a été identifié le genre xxx Rhodotorula (87,5%) et les espèces Trichosporon mucoides et Cryptococcus unigutulattus (12,5%). On a vérifié une association, au niveau de signification de 5%, entre les lésions visibles et les heures hebdomadaires et entre les lésions visibles et la durée d’occupation, ce qui confirme l'influence de la durée de l'exposition aux facteurs de risque (contamination fongique dans le milieu de travail) pour la présence des lésions visibles chez les travailleurs exposés (Tinea pedis et onychomycose), en démontrant une relation entre l'exposition au facteur de risque dans ces études - l'exposition professionnelle aux champignons - avec les effets sur la santé. Les variables environnementales évalué (température, humidité relative et la vitesse de l'air) ne modifient pas la contamination fongique de l'air et des surfaces; donc, n'a pas été démontré aucune relation statistiquement significative (p>0,05). Cependant, il y a une influence du nombre d'occupants qui ont participé à chacun des établissements en moyenne des unités formant colonie par mètre carré sur la surface avant le lavage et la désinfection. Il n'y avait pas de corrélation entre les résultats quantitatifs de la contamination fongique de l'air et des surfaces des 10 établissements surveillés, cependant il existe des différences importantes, au niveau de signification de 10% entre la contamination fongique des surfaces et de la contamination fongique de l'air (p <0,1), on a constaté que malgré 50% des niveaux les plus bas étaient plus élevés dans la contamination fongique de l'air, la contamination fongique des surfaces présentée une plus grande variabilité quantitativement. En ce qui concerne les différences de la contamination fongique des surfaces dans les 10 établissements entre avant et après le lavage et la désinfection, il y avait seulement une réduction significative (p<0,05) de la contamination fongique après le lavage et la désinfection dans les balnéaires et vestiaires pour les hommes par rapport aux levures. Lors de l'établissement choisi, on a constaté que le rapport entre la contamination fongique et la température et l'humidité relative n'était pas significatif (p>0,05) dans les deux saisons et aussi on n’a pas observé l'influence des occupants en moyenne des unités formant colonie par mètres carrés de surfaces avant le lavage et la désinfection dans les deux saisons de l'année. Dans presque toutes les situations ou on a vérifié des différences significatives entre les deux saisons, il ya eu une augmentation des unités formant des colonies par mètre carré en Hiver, à l'exception du total des unités formant des colonies par mètre carré avant le lavage et désinfection dans les balnéaires et vestiaires des hommes où il y a eu une augmentation en Été. On a également été constaté que seulement a eu une réduction de la contamination des xxxi champignons après la désinfection de l'escalier d'accès en Hiver et dans les balnéaires et vestiaires des hommes en Été. Avec la méthode pour établir standard d’exposition professionnelle au fungi sur les surfaces on a obtenu dans les 10 établissements, avec le Niveau de Risque Faible de 65 places (54,2%), avec le Niveau de Risque Moyen 23 places (19,2%) et 32 places avec le Niveau de Risque Élevé (26,6%). Près du jacuzzi et près de la piscine sont les lieux avec des plus évaluations de Niveau de Risque Élevé. Lors de l'établissement choisi, il a été constaté que, dans l'Été, après le lavage et la désinfection, un plus grand nombre de places évaluées comme présentant un Niveau de Risque Élevé et en Hiver on a constaté la situation inverse avec de nombreux points de Niveau de Risque Élevé avant le lavage et la désinfection. A côté de la piscine et les escaliers ont été les lieux avec plus grands classifications de Niveau de Risque Élevé en Été et en Hiver. On a isolé, chez les travailleurs, des champignons communs aux isolés sur les surfaces. Avant le lavage et la désinfection, 30,3% des champignons ont été isolés sur les travailleurs et sur les surfaces et, après ces procédures, 45,5% des champignons ont été isolés fréquemment. Les levures les plus souvent isolées et les plus fréquentes avant et après le lavage et la désinfection des surfaces, et aussi dans les résultats d'échantillons biologiques prélevés sur les travailleurs, étaient du genre Rhodotorula et les espèces de Candida parapsilosis, ce qui permet confirmer que l'infection fongique des travailleurs est liée à la contamination fongique des surfaces. On a conclu qu’il est nécessaire l'intervention en Santé Occupationnelle sous la surveillance de l'environnement et sous la surveillance de la santé, afin de réduire la prévalence des infections fongiques. Pour atteindre cet objectif, nous suggérons la mise en oeuvre de mesures préventives, y compris: le contrôle de la contamination fongique des surfaces par des méthodes de lavage et de désinfection afin de minimiser la contamination fongique des surfaces, l'identification précoce de l'infection avec des prélèvements biologiques périodiques, notamment un protocole pour la surveillance de la santé, et aussi la conscience du sens de l'hygiène personnelle et le traitement des pathologies. La méthode mise en place pour l’établissement d’un standard d’exposition professionnelle au fungi sur les surfaces, servira à estimer non seulement le risque d'infection fongique des travailleurs dans les gymnases avec des piscines, mais aussi pour faciliter l'établissement de valeurs de référence de champignons, l'application des mesures correctives immédiates et appropriées, et aussi la prévention des infections fongiques, non seulement dans les gymnases avec piscine, mais aussi dans d'autres contextes professionnels.
Resumo:
Uimaveden klooridesinfioinnissa syntyy sivutuotteena haihtuvia ja haitallisia halogeeniyhdisteitä, kuten trihalometaaneja ja triklooriamiinia, jotka voivat heikentää allas-tilan sisäilman laatua merkittävästi. Tämän tutkimuksen tavoitteena oli kartoittaa näiden desinfioinnin sivutuotteiden pitoisuuksia suomalaisissa uimahalleissa sekä selvittää epäpuhtauksien kulkeutumista allastiloissa. Lisäksi pyrittiin löytämään merkittävimmät veden laatu- ja käsittelyparametrit sekä ilmanvaihtotekniset tekijät, jotka vaikuttavat vedestä haihtuvien epäpuhtauksien pitoisuuksiin hallitiloissa. Mittaukset tehtiin kymmenessä eri puolilla Suomea sijaitsevassa uimahallissa. Mittausten perusteella havaittiin, että allastilojen kloroformipitoisuudet vaihtelivat välillä 8,9-84,0 ¿g/m3. Terapia-allasostoilta mitatut pitoisuudet olivat pääallastiloista mitattuja pitoisuuksia suurempia ja aamulla mitattu pitoisuus alhaisempi kuin illalla mitattu. Lisäksi ilmastoiduista valvomoista mitatut pitoisuudet olivat merkittävästi allastilojen pitoisuuksia pienempiä. Triklooriamiininäytteistä suurin osa oli alle määritysrajan. Sisäilman kloroformipitoisuuden havaittiin korreloivan veden lämpötilan sekä ilman kosteuden kanssa. Triklooriamiinille tilastollista analyysiä ei voitu tehdä mm. määritys-rajan alle jääneiden näytteiden suuren osuuden vuoksi. Teknisten kyselyiden ja ilmanvaihtomittausten perusteella todettiin, että uimahallien ilmanvaihto toimii lämmitystarpeen vuoksi sekoittavana ja epäpuhtauksien leviämistä allastilassa ei voida käytännössä katsoen estää. Ilman virtausnopeudet pääaltaiden reunoilla olivat pieniä ja ilman virtauskenttien ei todettu vaikuttavan epäpuhtauksien kulkeutumiseen allastiloissa. Mittauskohteiden vähyydestä ja vedenkäsittelyn hallikohtaisista erityispiirteistä johtuen luotettavia johtopäätöksiä vedenkäsittelymenetelmien vaikutuksesta allasveden ja allastilan ilman laatuun ei pystytty tekemään.
Resumo:
La désinfection de l’eau de consommation et des piscines induit la formation de sous-produits (SPD) potentiellement nocifs pour la santé, parmi lesquels les trihalométhanes (THM), les acides haloacétiques (HAA) et les chloramines (CAM). La difficulté d’estimer l’exposition humaine à ces SPD empêche de cerner précisément les risques sanitaires possiblement associés (i.e., cancérigènes, reprotoxiques, irritatifs). Nos travaux s’articulent autour d’une méthodologie consistant à intégrer des données d’occurrence environnementales à des modèles toxicocinétiques à base physiologique (TCBP) pour améliorer les mesures de l’exposition aux SPD. Cette approche multidisciplinaire veut prendre en compte de manière aussi appropriée que possible les deux composantes majeures des variations de cette exposition : les variations spatio-temporelles des niveaux de contamination environnementale et l’impact des différences inter- et intra-individuelles sur les niveaux biologiques. Cette thèse, organisée en deux volets qui explorent chacun successivement des aspects environnemental et biologique de la problématique, vise à contribuer au développement de cette stratégie innovante d’estimation de l’exposition et, plus généralement, à des meilleures pratiques en la matière. Le premier volet de la thèse s’intéresse à l’exposition en milieu domestique (i.e., résultant de l’utilisation de l’eau potable au domicile) et est consacré au cas complexe des THM, les plus abondants et volatils des SPD, absorbables par ingestion mais aussi par inhalation et voie percutanée. Les articles I et II, constitutifs de ce volet, documentent spécifiquement la question des variations inter- et intra- journalières de présence des SPD en réseau et de leurs impacts sur les estimateurs de l’exposition biologique. Ils décrivent l’amplitude et la diversité des variations à court terme des niveaux environnementaux, présentent les difficultés à proposer une façon systématique et « épidémiologiquement » pratique de les modéliser et proposent, de manière originale, une évaluation des mésestimations, somme toute modestes, des mesures biologiques de l’exposition résultant de leurs non-prise en compte. Le deuxième volet de la thèse se penche sur l’exposition aux SPD en piscine, d’un intérêt grandissant au niveau international, et se restreint au cas jugé prioritaire des piscines publiques intérieures. Ce volet envisage, pour quantifier l’exposition dans ce contexte particulier, l’extension de l’approche méthodologique préconisée, élaborée originellement pour application dans un contexte domestique : d’abord, à travers une analyse approfondie des variations des niveaux de contamination (eau, air) des SPD en piscine en vue de les modéliser (article III); puis en examinant, dans le cas particulier du chloroforme, le THM le plus abondant, la possibilité d’utiliser la modélisation TCBP pour simuler des expositions en piscine (article IV). Les résultats mettent notamment en évidence la difficulté d’appréhender précisément la contamination environnementale autrement que par un échantillonnage in situ tandis que la modélisation TCBP apparait, sur le plan toxicologique, comme l’outil le plus pertinent à ce jour, notamment au regard des autres approches existantes, mais qu’il convient d’améliorer pour mieux prédire les niveaux d’exposition biologique. Finalement, ces travaux illustrent la pertinence et la nécessité d’une approche multidisciplinaire et intégratrice et suggère, sur cette base, les pistes à explorer en priorité pour mieux évaluer l’exposition aux SPD et, in fine, cerner véritablement les risques sanitaires qui en résultent.
Resumo:
In this thesis, one of the current control algorithms for the R744 cycle, which tries tooptimize the performance of the system by two SISO control loops, is compared to acost-effective system with just one actuator. The operation of a key component of thissystem, a two stage orifice expansion valve is examined in a range of typical climateconditions. One alternative control loop for this system, which has been proposed byBehr group, is also scrutinized.The simulation results affirm the preference of using two control-loops instead of oneloop, but refute advantages of the Behr alternate control approach against one-loopcontrol. As far as the economic considerations of the A/C unit are concerned, usinga two-stage orifice expansion valve is desired by the automotive industry, thus basedon the experiment results, an improved logic for control of this system is proposed.In the second part, it is investigated whether the one-actuator control approach isapplicable to a system consisting of two parallel evaporators to allow passengers tocontrol different climate zones. The simulation results show that in the case of usinga two-stage orifice valve for the front evaporator and a fixed expansion valve forthe rear one, a proper distribution of the cooling power between the front and rearcompartment is possible for a broad range of climate conditions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^
Resumo:
Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.
Resumo:
Based on the authors' thesis, University of Illinois, Urbana.
Resumo:
Mode of access: Internet.
Resumo:
Bibliography: p. 63.