881 resultados para Soft errors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a commercial environment, it is advantageous to know how long it takes customers to move between different regions, how long they spend in each region, and where they are likely to go as they move from one location to another. Presently, these measures can only be determined manually, or through the use of hardware tags (i.e. RFID). Soft biometrics are characteristics that can be used to describe, but not uniquely identify an individual. They include traits such as height, weight, gender, hair, skin and clothing colour. Unlike traditional biometrics, soft biometrics can be acquired by surveillance cameras at range without any user cooperation. While these traits cannot provide robust authentication, they can be used to provide identification at long range, and aid in object tracking and detection in disjoint camera networks. In this chapter we propose using colour, height and luggage soft biometrics to determine operational statistics relating to how people move through a space. A novel average soft biometric is used to locate people who look distinct, and these people are then detected at various locations within a disjoint camera network to gradually obtain operational statistics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current complication rates for adolescent scoliosis surgery necessitate the development of better surgical planning tools to improve outcomes. Here we present our approach to developing finite element models of the thoracolumbar spine for deformity surgery simulation, with patient-specific model anatomy based on low-dose pre-operative computed tomography scans. In a first step towards defining patient-specific tissue properties, an initial 'benchmark' set of properties were used to simulate a clinically performed pre-operative spinal flexibility assessment, the fulcrum bending radiograph. Clinical data for ten patients were compared with the simulated results for this assessment and in cases where these data differed by more than 10%, soft tissue properties for the costo-vertebral joint (CVJt) were altered to achieve better agreement. Results from these analyses showed that changing the CVJt stiffness resulted in acceptable agreement between clinical and simulated flexibility in two of the six cases. In light of these results and those of our previous studies in this area, it is suggested that spinal flexibility in the fulcrum bending test is not governed by any single soft tissue structure acting in isolation. More detailed biomechanical characterisation of the fulcrum bending test is required to provide better data for determination of patient-specific soft tissue properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stormwater quality modelling results is subject to uncertainty. The variability of input parameters is an important source of overall model error. An in-depth understanding of the variability associated with input parameters can provide knowledge on the uncertainty associated with these parameters and consequently assist in uncertainty analysis of stormwater quality models and the decision making based on modelling outcomes. This paper discusses the outcomes of a research study undertaken to analyse the variability related to pollutant build-up parameters in stormwater quality modelling. The study was based on the analysis of pollutant build-up samples collected from 12 road surfaces in residential, commercial and industrial land uses. It was found that build-up characteristics vary appreciably even within the same land use. Therefore, using land use as a lumped parameter would contribute significant uncertainties in stormwater quality modelling. Additionally, it was also found that the variability in pollutant build-up can also be significant depending on the pollutant type. This underlines the importance of taking into account specific land use characteristics and targeted pollutant species when undertaking uncertainty analysis of stormwater quality models or in interpreting the modelling outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the use of optical coherence tomography (OCT) to assess the effect of different soft contact lenses on corneoscleral morphology. Methods. Ten subjects had anterior segment OCT B-scans taken in the morning and again after six hours of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL) and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements, was used to assess the effect of the contact lens on the corneoscleral morphology. Results. The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p <0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93±1.95 µm for the HRL and 4.02±2.14 µm for the EBL) than those measured in the limbal/scleral region (11.24±6.21 µm for the HRL and 12.61±6.42 µm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84±0.84 µm) than the limbal/scleral (5.47±1.71 µm) region. Post-hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p<0.005) and hydrogel sphere (p<0.02) for the combined HRL and EBL data. Conclusions. In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To examine the effect of thermal agents on the range of movement (ROM) and mechanical properties in soft tissue and to discuss their clinical relevance. DATA SOURCES: Electronic databases (Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE) were searched from their earliest available record up to May 2011 using Medical Subjects Headings and key words. We also undertook related articles searches and read reference lists of all incoming articles. STUDY SELECTION: Studies involving human participants describing the effects of thermal interventions on ROM and/or mechanical properties in soft tissue. Two reviewers independently screened studies against eligibility criteria. DATA EXTRACTION: Data were extracted independently by 2 review authors using a customized form. Methodologic quality was also assessed by 2 authors independently, using the Cochrane risk of bias tool. DATA SYNTHESIS: Thirty-six studies, comprising a total of 1301 healthy participants, satisfied the inclusion criteria. There was a high risk of bias across all studies. Meta-analyses were not undertaken because of clinical heterogeneity; however, effect sizes were calculated. There were conflicting data on the effect of cold on joint ROM, accessory joint movement, and passive stiffness. There was limited evidence to determine whether acute cold applications enhance the effects of stretching, and further evidence is required. There was evidence that heat increases ROM, and a combination of heat and stretching is more effective than stretching alone. CONCLUSIONS: Heat is an effective adjunct to developmental and therapeutic stretching techniques and should be the treatment of choice for enhancing ROM in a clinical or sporting setting. The effects of heat or ice on other important mechanical properties (eg, passive stiffness) remain equivocal and should be the focus of future study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reporting of medication administration errors (MAEs) is one means by which health care facilities monitor their practice in an attempt to maintain the safest patient environment. This study examined the likelihood of registered nurses (RNs) reporting MAEs when working in Saudi Arabia. It also attempted to identify potential barriers in the reporting of MAE. This study found that 63% of RNs raised concerns about reporting of MAEs in Saudi Arabia—nursing administration was the largest impediment affecting nurses' willingness to report MAEs. Changing attitude to a non-blame system and implementation of anonymous reporting systems may encourage a greater reporting of MAEs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The future emergence of many types of airborne vehicles and unpiloted aircraft in the national airspace means collision avoidance is of primary concern in an uncooperative airspace environment. The ability to replicate a pilot’s see and avoid capability using cameras coupled with vision based avoidance control is an important part of an overall collision avoidance strategy. But unfortunately without range collision avoidance has no direct way to guarantee a level of safety. Collision scenario flight tests with two aircraft and a monocular camera threat detection and tracking system were used to study the accuracy of image-derived angle measurements. The effect of image-derived angle errors on reactive vision-based avoidance performance was then studied by simulation. The results show that whilst large angle measurement errors can significantly affect minimum ranging characteristics across a variety of initial conditions and closing speeds, the minimum range is always bounded and a collision never occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review of Soft Power in China: Public diplomacy through communication, edited by J IAN WANG, New York, Palgrave Macmillan, 2011, US$89 (hard), 220 pp

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What role does China play in Western imagination and how does it affect Western selfconceptions? The rise of China as an alternative model to Western liberalism has created a fear that developing countries will stray from Western standards of democracy, transparency and human rights. However, such fears often say as much about those who hold them as they do about China itself. In this short and easily readable book Barr holds a mirror to Sino–Western relations in order to better understand how the West’s own past, hopes and fears shape the way it thinks about and engages with China. Focusing on three key areas—models of development, soft power and ethnocentrism—he argues that the rise of China ‘hits a nerve in the Western psyche . . . because its actions reflect the West’s own ambivalence to modernity and uncertainty over the proper role and limits of state power’ (p. 21). To make his point, Barr focuses on China’s soft power and the connections between China’s domestic politics and its attempts to shape its image internationally...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High energy bone fractures resulting from impact trauma are often accompanied by subcutaneous soft tissue injuries, even if the skin remains intact. There is evidence that such closed soft tissue injuries affect the healing of bone fractures, and vice versa. Despite this knowledge, most impact trauma studies in animals have focussed on bone fractures or soft tissue trauma in isolation. However, given the simultaneous impact on both tissues a better understanding of the interaction between these two injuries is necessary to optimise clinical treatment. The aim of this study was therefore to develop a new experimental model and characterise, for the first time, the healing of a complex fracture with concurrent closed soft tissue trauma in sheep. A pendulum impact device was designed to deliver a defined and standardised impact to the distal thigh of sheep, causing a reproducible contusion injury to the subcutaneous soft tissues. In a subsequent procedure, a reproducible femoral butterfly fracture (AO C3-type) was created at the sheep’s femur, which was initially stabilised for 5 days by an external fixator construct to allow for soft tissue swelling to recede, and ultimately in a bridging construct using locking plates. The combined injuries were applied to twelve sheep and the healing observed for four or eight weeks (six animals per group) until sacrifice. The pendulum impact led to a moderate to severe circumferential soft tissue injury with significant bruising, haematomas and partial muscle disruptions. Posttraumatic measurements showed elevated intra-compartmental pressure and circulatory tissue breakdown markers, with recovery to normal, pre-injury values within four days. Clinically, no neurovascular deficiencies were observed. Bi-weekly radiological analysis of the healing fractures showed progressive callus healing over time, with the average number of callus bridges increasing from 0.4 at two weeks to 4.2 at eight weeks. Biomechanical testing after sacrifice showed increasing torsional stiffness between four and eight weeks healing time from 10% to 100%, and increasing ultimate torsional strength from 10% to 64% (relative to the contralateral control limb). Our results demonstrate the robust healing of a complex femur fracture in the presence of a severe soft tissue contusion injury in sheep and demonstrate the establishment of a clinically relevant experimental model, for research aimed at improving the treatment of bone fractures accompanied by closed soft tissue injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective digital human model (DHM) simulation of automotive driver packaging ergonomics, safety and comfort depends on accurate modelling of occupant posture, which is strongly related to the mechanical interaction between human body soft tissue and flexible seat components. This paper presents a finite-element study simulating the deflection of seat cushion foam and supportive seat structures, as well as human buttock and thigh soft tissue when seated. The three-dimensional data used for modelling thigh and buttock geometry were taken on one 95th percentile male subject, representing the bivariate percentiles of the combined hip breadth (seated) and buttock-to-knee length distributions of a selected Australian and US population. A thigh-buttock surface shell based on this data was generated for the analytic model. A 6mm neoprene layer was offset from the shell to account for the compression of body tissue expected through sitting in a seat. The thigh-buttock model is therefore made of two layers, covering thin to moderate thigh and buttock proportions, but not more fleshy sizes. To replicate the effects of skin and fat, the neoprene rubber layer was modelled as a hyperelastic material with viscoelastic behaviour in a Neo-Hookean material model. Finite element (FE) analysis was performed in ANSYS V13 WB (Canonsburg, USA). It is hypothesized that the presented FE simulation delivers a valid result, compared to a standard SAE physical test and the real phenomenon of human-seat indentation. The analytical model is based on the CAD assembly of a Ford Territory seat. The optimized seat frame, suspension and foam pad CAD data were transformed and meshed into FE models and indented by the two layer, soft surface human FE model. Converging results with the least computational effort were achieved for a bonded connection between cushion and seat base as well as cushion and suspension, no separation between neoprene and indenter shell and a frictional connection between cushion pad and neoprene. The result is compared to a previous simulation of an indentation with a hard shell human finite-element model of equal geometry, and to the physical indentation result, which is approached with very high fidelity. We conclude that (a) SAE composite buttock form indentation of a suspended seat cushion can be validly simulated in a FE model of merely similar geometry, but using a two-layer hard/soft structure. (b) Human-seat indentation of a suspended seat cushion can be validly simulated with a simplified human buttock-thigh model for a selected anthropomorphism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book examines different aspects of Asian popular culture, including films, TV, music, comedy, folklore, cultural icons, the Internet and theme parks. It raises important questions such as – What are the implications of popularity of Asian popular culture for globalization? Do regional forces impede the globalizing of cultures? Or does the Asian popular culture flow act as a catalyst or conveying channel for cultural globalization? Does the globalization of culture pose a threat to local culture? It addresses two seemingly contradictory and yet parallel processes in the circulation of Asian popular culture: the interconnectedness between Asian popular culture and western culture in an era of cultural globalization that turns subjects such as Pokémon, Hip Hop or Cosmopolitan into truly global phenomena, and the local derivatives and versions of global culture that are necessarily disconnected from their origins in order to cater for the local market. It thereby presents a collective argument that, whilst local social formations, and patterns of consumption and participation in Asia are still very much dependent on global cultural developments and the phenomena of modernity, yet such dependence is often concretized, reshaped and distorted by the local media to cater for the local market. Contents: Introduction: Asian Popular Culture: The Global (Dis)continuity Anthony Y.H. Fung Part 1: The Dominance of Global Continuity: Cultural Localization and Adaptation 1. One Region, Two Modernities: Disneyland in Tokyo and Hong Kong Micky Lee and Anthony Y.H. Fung 2. Comic Travels: Disney Publishing in the People’s Republic of China Jennifer Altehenger 3. When Chinese Youth Meet Harry Potter: Translating Consumption and Middle Class Identification John Nguyet Erni 4.New Forms of Transborder Visuality in Urban China: Saving Face for Magazine Covers Eric Kit-Wai Ma 5. Cultural Consumption and Masculinity: A Case Study of GQ Magazine Covers in Taiwan Hong-Chi Shiau Part 2: Global Discontinuity: The Local Absorption of Global Culture 6. An Unlocalized and Unglobalized Subculture: English Language Independent Music in Singapore Kai Khiun Liew and Shzr Ee Tan 7. The Localized Production of Jamaican Music in Thailand Viriya Sawangchot 8. Consuming Online Games in Taiwan: Global Games and Local Market Lai-Chi Chen 9. The Rise of the Korean Cinema in Inbound and Outbound Globalization Shin Dong Kim Part 3: Cultural Domestication: A New Form of Global Continuity 10. Pocket Capitalism and Virtual Intimacy: Pokémon as a Symptom of Post-Industrial Youth Culture Anne Allison 11. Playing the Global Game: Japan Brand and Globalization Kukhee Choo Part 4: China as a Rising Market: Cultural Antagonism and Globalization 12. China’s New Creative Strategy: The Utilization of Cultural Soft Power and New Markets Michael Keane and Bonnie Liu 13. Renationalizing Hong Kong Cinema: The Gathering Force of the Mainland Market Michael Curtin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Achieving soft tissue balance is an operative goal in total knee arthroplasty. This randomised, prospective study compared computer navigation to conventional techniques in achieving soft tissue balance. Methods: Forty one consecutive knee arthroplasties were randomised to either a non-navigated or navigated group. In the non-navigated group, balancing was carried out using surgeon judgement. In the navigated group, balancing was carried out using navigation software. In both groups, the navigation software was used as a measuring tool. Results: Balancing of the mediolateral extension gap was superior in the navigation group (p=0.001). No significant difference was found between the two groups in balancing the mediolateral flexion gap or in achieving equal flexion and extension gaps. Conclusions: Computer navigation offered little advantage over experienced surgeon judgement in achieving soft tissue balance in knee replacement. However, the method employed in the navigated group did provide a reproducible and objective assessment of flexion and extension gaps and may therefore benefit surgeons in training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously reported a preliminary taxonomy of patient error. However, approaches to managing patients' contribution to error have received little attention in the literature. This paper aims to assess how patients and primary care professionals perceive the relative importance of different patient errors as a threat to patient safety. It also attempts to suggest what these groups believe may be done to reduce the errors, and how. It addresses these aims through original research that extends the nominal group analysis used to generate the error taxonomy. Interviews were conducted with 11 purposively selected groups of patients and primary care professionals in Auckland, New Zealand, during late 2007. The total number of participants was 83, including 64 patients. Each group ranked the importance of possible patient errors identified through the nominal group exercise. Approaches to managing the most important errors were then discussed. There was considerable variation among the groups in the importance rankings of the errors. Our general inductive analysis of participants' suggestions revealed the content of four inter-related actions to manage patient error: Grow relationships; Enable patients and professionals to recognise and manage patient error; be Responsive to their shared capacity for change; and Motivate them to act together for patient safety. Cultivation of this GERM of safe care was suggested to benefit from 'individualised community care'. In this approach, primary care professionals individualise, in community spaces, population health messages about patient safety events. This approach may help to reduce patient error and the tension between personal and population health-care.