984 resultados para SPECTROSCOPY, MOSSBAUER - Applications
Resumo:
Non crystalline (nc) EuIG and DyIG have been prepared by dc¿sputtering. Mössbauer data on 57Fe, 151Eu and 161Dy reveal sharp magnetic transitions at 62 K and 70 K for nc EuIG and DyIG, respectively. The 57Fe hyperfine (hf) spectra consist of three superpositioned patterns for Fe3+ in tetrahedral and octahedral and for Fe2+ in tetrahedral oxygen coordination. The saturation hf fields at 4.2 K are reduced compared to the values of the corresponding crystalline materials. The induced hf field at 151Eu is only 1/8 of that for crystalline EuIG
Resumo:
Conversion electron Mossbauer spectra of composition modulated FeSi thin films have been analysed within the framework of a quasi shape independent model in which the distribution function for the hyperfine fields is assumed to be given by a binomial distribution. Both the hyperfine field and the hyperfine field distribution depend on the modulation characteristic length.
Resumo:
This article summarizes the basic principles of photoelectron spectroscopy for surface analysis, with examples of applications in material science that illustrate the capabilities of the related techniques.
Resumo:
This article summarizes the basic principles of electron probe microanalysis, with examples of applications in materials science and geology that illustrate the capabilities of the technique.
Resumo:
Les échantillons biologiques ne s?arrangent pas toujours en objets ordonnés (cristaux 2D ou hélices) nécessaires pour la microscopie électronique ni en cristaux 3D parfaitement ordonnés pour la cristallographie rayons X alors que de nombreux spécimens sont tout simplement trop << gros D pour la spectroscopie NMR. C?est pour ces raisons que l?analyse de particules isolées par la cryo-microscopie électronique est devenue une technique de plus en plus importante pour déterminer la structure de macromolécules. Néanmoins, le faible rapport signal-sur-bruit ainsi que la forte sensibilité des échantillons biologiques natifs face au faisceau électronique restent deux parmi les facteurs limitant la résolution. La cryo-coloration négative est une technique récemment développée permettant l?observation des échantillons biologiques avec le microscope électronique. Ils sont observés à l?état vitrifié et à basse température, en présence d?un colorant (molybdate d?ammonium). Les avantages de la cryo-coloration négative sont étudiés dans ce travail. Les résultats obtenus révèlent que les problèmes majeurs peuvent êtres évités par l?utilisation de cette nouvelle technique. Les échantillons sont représentés fidèlement avec un SNR 10 fois plus important que dans le cas des échantillons dans l?eau. De plus, la comparaison de données obtenues après de multiples expositions montre que les dégâts liés au faisceau électronique sont réduits considérablement. D?autre part, les résultats exposés mettent en évidence que la technique est idéale pour l?analyse à haute résolution de macromolécules biologiques. La solution vitrifiée de molybdate d?ammonium entourant l?échantillon n?empêche pas l?accès à la structure interne de la protéine. Finalement, plusieurs exemples d?application démontrent les avantages de cette technique nouvellement développée.<br/><br/>Many biological specimens do not arrange themselves in ordered assemblies (tubular or flat 2D crystals) suitable for electron crystallography, nor in perfectly ordered 3D crystals for X-ray diffraction; many other are simply too large to be approached by NMR spectroscopy. Therefore, single-particles analysis has become a progressively more important technique for structural determination of large isolated macromolecules by cryo-electron microscopy. Nevertheless, the low signal-to-noise ratio and the high electron-beam sensitivity of biological samples remain two main resolution-limiting factors, when the specimens are observed in their native state. Cryo-negative staining is a recently developed technique that allows the study of biological samples with the electron microscope. The samples are observed at low temperature, in the vitrified state, but in presence of a stain (ammonium molybdate). In the present work, the advantages of this novel technique are investigated: it is shown that cryo-negative staining can generally overcome most of the problems encountered with cryo-electron microscopy of vitrified native suspension of biological particles. The specimens are faithfully represented with a 10-times higher SNR than in the case of unstained samples. Beam-damage is found to be considerably reduced by comparison of multiple-exposure series of both stained and unstained samples. The present report also demonstrates that cryo-negative staining is capable of high- resolution analysis of biological macromolecules. The vitrified stain solution surrounding the sample does not forbid the access to the interna1 features (ie. the secondary structure) of a protein. This finding is of direct interest for the structural biologist trying to combine electron microscopy and X-ray data. developed electron microscopy technique. Finally, several application examples demonstrate the advantages of this newly
Resumo:
A novel cantilever pressure sensor was developed in the Department of Physics at the University of Turku in order to solve the sensitivity problems which are encountered when condenser microphones are used in photoacoustic spectroscopy. The cantilever pressure sensor, combined with a laser interferometer for the measurement of the cantilever movements, proved to be highly sensitive. The original aim of this work was to integrate the sensor in a photoacoustic gas detector working in a differential measurement scheme. The integration was made successfully into three prototypes. In addition, the cantilever was also integrated in the photoacoustic FTIR measurement schemes of gas-, liquid-, and solid-phase samples. A theoretical model for the signal generation in each measurement scheme was created and the optimal celldesign discussed. The sensitivity and selectivity of the differential method were evaluated when a blackbody radiator and a mechanical chopper were used with CO2, CH4, CO, and C2H4 gases. The detection limits were in the sub-ppm level for all four gases with only a 1.3 second integration time and the cross interference was well below one percent for all gas combinations other than those between hydrocarbons. Sensitivity with other infrared sources was compared using ethylene as an example gas. In the comparison of sensitivity with different infrared sources the electrically modulated blackbody radiator gave a 35 times higher and the CO2-laser a 100 times lower detection limit than the blackbody radiator with a mechanical chopper. As a conclusion, the differential system is well suited to rapid single gas measurements. Gas-phase photoacoustic FTIR spectroscopy gives the best performance, when several components have to be analyzed simultaneously from multicomponent samples. Multicomponent measurements were demonstrated with a sample that contained different concentrations of CO2, H2O, CO, and four different hydrocarbons. It required an approximately 10 times longer measurement time to achieve the same detection limit for a single gas as with the differential system. The properties of the photoacoustic FTIR spectroscopy were also compared to conventional transmission FTIR spectroscopy by simulations. Solid- and liquid-phase photoacoustic FTIR spectroscopy has several advantages compared to other techniques and therefore it also has a great variety of applications. A comparison of the signal-to-noise ratio between photoacoustic cells with a cantilever microphone and a condenser microphone was done with standard carbon black, polyethene, and sunflower oil samples. The cell with the cantilever microphone proved to have a 5-10 times higher signal-to-noise ratio than the reference detector, depending on the sample. Cantilever enhanced photoacoustics will be an effective tool for gas detection and analysis of solid- and liquid-phase samples. The preliminary prototypes gave good results in all three measurement schemes that were studied. According to simulations, there are possibilities for further enhancement of the sensitivity, as well as other properties, of each system.
Resumo:
In this study, cantilever-enhanced photoacoustic spectroscopy (CEPAS) was applied in different drug detection schemes. The study was divided into two different applications: trace detection of vaporized drugs and drug precursors in the gas-phase, and detection of cocaine abuse in hair. The main focus, however, was the study of hair samples. In the gas-phase, methyl benzoate, a hydrolysis product of cocaine hydrochloride, and benzyl methyl ketone (BMK), a precursor of amphetamine and methamphetamine were investigated. In the solid-phase, hair samples from cocaine overdose patients were measured and compared to a drug-free reference group. As hair consists mostly of long fibrous proteins generally called keratin, proteins from fingernails and saliva were also studied for comparison. Different measurement setups were applied in this study. Gas measurements were carried out using quantum cascade lasers (QLC) as a source in the photoacoustic detection. Also, an external cavity (EC) design was used for a broader tuning range. Detection limits of 3.4 particles per billion (ppb) for methyl benzoate and 26 ppb for BMK in 0.9 s were achieved with the EC-QCL PAS setup. The achieved detection limits are sufficient for realistic drug detection applications. The measurements from drug overdose patients were carried out using Fourier transform infrared (FTIR) PAS. The drug-containing hair samples and drug-free samples were both measured with the FTIR-PAS setup, and the measured spectra were analyzed statistically with principal component analysis (PCA). The two groups were separated by their spectra with PCA and proper spectral pre-processing. To improve the method, ECQCL measurements of the hair samples, and studies using photoacoustic microsampling techniques, were performed. High quality, high-resolution spectra with a broad tuning range were recorded from a single hair fiber. This broad tuning range of an EC-QCL has not previously been used in the photoacoustic spectroscopy of solids. However, no drug detection studies were performed with the EC-QCL solid-phase setup.
Resumo:
Poly-L-lactide (PLLA) is a widely used sustainable and biodegradable alternative to replace synthetic non-degradable plastic materials in the packaging industry. Conversely, its processing properties are not always optimal, e.g. insufficient melt strength at higher temperatures (necessary in extrusion coating processes). This thesis reports on research to improve properties of commercial PLLA grade (3051D from NatureWorks), to satisfy and extend end-use applications, such as food packaging by blending with modified PLLA. Adjustment of the processability by chain branching of commercial poly-L-lactide initiated by peroxide was evaluated. Several well-defined branched structures with four arms (sPLLA) were synthesized using pentaerythritol as a tetra-functional initiator. Finally, several block copolymers consisting of polyethylene glycol and PLLA (i.e. PEGLA) were produced to obtain a well extruded material with improved heat sealing properties. Reactive extrusion of poly-L-lactide was carried out in the presence of 0.1, 0.3 and 0.5 wt% of various peroxides [tert-butyl-peroxybenzoate (TBPB), 2,5-dimethyl-2,5-(tert-butylperoxy)-hexane (Lupersol 101; LOL1) and benzoyl peroxide (BPO)] at 190C. The peroxide-treated PLLAs showed increased complex viscosity and storage modulus at lower frequencies, indicating the formation of branched/cross linked architectures. The material property changes were dependent on the peroxide, and the used peroxide concentration. Gel fraction analysis showed that the peroxides, afforded different gel contents, and especially 0.5 wt% peroxide, produced both an extremely high molar mass, and a cross linked structure, not perhaps well suited for e.g. further use in a blending step. The thermal behavior was somewhat unexpected as the materials prepared with 0.5 wt% peroxide showed the highest ability for crystallization and cold crystallization, despite substantial cross linking. The peroxide-modified PLLA, i.e. PLLA melt extruded with 0.3 wt% of TBPB and LOL1 and 0.5 wt% BPO was added to linear PLLA in ratios of 5, 15 and 30 wt%. All blends showed increased zero shear viscosity, elastic nature (storage modulus) and shear sensitivity. All blends remained amorphous, though the ability of annealing was improved slightly. Extrusion coating on paperboard was conducted with PLLA, and peroxide-modified PLLA blends (90:10). All blends were processable, but only PLLA with 0.3 wt% of LOL1 afforded a smooth high quality surface with improved line speed. Adhesion levels between fiber and plastic, as well as heat seal performance were marginally reduced compared with pure 3051D. The water vapor transmission measurements (WVTR) of the blends containing LOL1 showed acceptable levels, only slightly lower than for comparable PLLA 3051D. A series of four-arm star-shaped poly-L-lactide (sPLLA) with different branch length was synthesized by ring opening polymerization (ROP) of L-lactide using pentaerythritol as initiator and stannous octoate as catalyst. The star-shaped polymers were further blended with its linear resin and studied for their melt flow and thermal properties. Blends containing 30 wt% of sPLLA with low molecular weight (30 wt%; Mwtotal: 2500 g mol-1 and 15000 g mol-1) showed lower zero shear viscosity and significantly increased shear thinning, while at the same time slightly increased crystallization of the blend. However, the amount of crystallization increased significantly with the higher molecular weight sPLLA, therefore the star-shaped structure may play a role as nucleating agent. PLLA-polyethylene glycol–PLLA triblock copolymers (PEGLA) with different PLLA block length were synthesized and their applicability as blends with linear PLLA (3051D NatureWorks) was investigated with the intention of improving heat-seal and adhesion properties of extrusion-coated paperboard. PLLA-PEG-PLLA was obtained by ring opening polymerization (ROP) of L-lactide using PEG (molecular weight 6000 g mol-1) as an initiator, and stannous octoate as catalyst. The structures of the PEGLAs were characterized by proton nuclear magnetic resonance spectroscopy (1H-NMR). The melt flow and thermal properties of all PEGLAs and their blends were evaluated using dynamic rheology, and differential scanning calorimeter (DSC). All blends containing 30 wt% of PEGLAs showed slightly higher zero shear viscosity, higher shear thinning and increased melt elasticity (based on tan delta). Nevertheless, no significant changes in thermal properties were distinguished. High molecular weight PEGLAs were used in extrusion coating line with 3051D without problems.
Resumo:
The monitoring and control of hydrogen sulfide (H2S) level is of great interest for a wide range of application areas including food quality control, defense and antiterrorist applications and air quality monitoring e.g. in mines. H2S is a very poisonous and flammable gas. Exposure to low concentrations of H2S can result in eye irritation, a sore throat and cough, shortness of breath, and fluid retention in the lungs. These symptoms usually disappear in a few weeks. Long-term, low-level exposure may result in fatigue, loss of appetite, headache, irritability, poor memory, and dizziness. Higher concentrations of 700 - 800 ppm tend to be fatal. H2S has a characteristic smell of rotten egg. However, because of temporary paralysis of olfactory nerves, the smelling capability at concentrations higher than 100 ppm is severely compromised. In addition, volatile H2S is one of the main products during the spoilage of poultry meat in anaerobic conditions. Currently, no commercial H2S sensor is available which can operate under anaerobic conditions and can be easily integrated in the food packaging. This thesis presents a step-wise progress in the development of printed H2S gas sensors. Efforts were made in the formulation, characterization and optimization of functional printable inks and coating pastes based on composites of a polymer and a metal salt as well as a composite of a metal salt and an organic acid. Different processing techniques including inkjet printing, flexographic printing, screen printing and spray coating were utilized in the fabrication of H2S sensors. The dispersions were characterized by measuring turbidity, surface tension, viscosity and particle size. The sensing films were characterized using X-ray photoelectron spectroscopy, X-ray diffraction, atomic force microscopy and an electrical multimeter. Thin and thick printed or coated films were developed for gas sensing applications with the aim of monitoring the H2S concentrations in real life applications. Initially, a H2S gas sensor based on a composite of polyaniline and metal salt was developed. Both aqueous and solvent-based dispersions were developed and characterized. These dispersions were then utilized in the fabrication of roll-to-roll printed H2S gas sensors. However, the humidity background, long term instability and comparatively lower detection limit made these sensors less favourable for real practical applications. To overcome these problems, copper acetate based sensors were developed for H2S gas sensing. Stable inks with excellent printability were developed by tuning the surface tension, viscosity and particle size. This enabled the formation of inkjet-printed high quality copper acetate films with excellent sensitivity towards H2S. Furthermore, these sensors showed negligible humidity effects and improved selectivity, response time, lower limit of detection and coefficient of variation. The lower limit of detection of copper acetate based sensors was further improved to sub-ppm level by incorporation of catalytic gold nano-particles and subsequent plasma treatment of the sensing film. These sensors were further integrated in an inexpensive wirelessly readable RLC-circuit (where R is resistor, L is inductor and C is capacitor). The performance of these sensors towards biogenic H2S produced during the spoilage of poultry meat in the modified atmosphere package was also demonstrated in this thesis. This serves as a proof of concept that these sensors can be utilized in real life applications.
Resumo:
Le sujet général de cette thèse est l’étude de la fonctionnalisation covalente des nanotubes de carbone (CNT) et son application en électronique. Premièrement, une introduction au sujet est présentée. Elle discute des propriétés des CNT, des différentes sortes de fonctionnalisation covalente ainsi que des principales techniques de caractérisation utilisées au cours de la thèse. Deuxièmement, les répercussions de la fonctionnalisation covalente sur les propriétés des nanotubes de carbone monoparoi (SWNT) sont étudiées. Deux types de fonctionnalisation sont regardés, soit le greffage de groupements phényles et le greffage de groupements dichlorométhylènes. Une diminution de l’absorption optique des SWNT dans le domaine du visible-proche infrarouge est observée ainsi qu’une modification de leur spectre Raman. De plus, pour les dérivés phényles, une importante diminution de la conductance des nanotubes est enregistrée. Troisièmement, la réversibilité de ces deux fonctionnalisations est examinée. Il est montré qu’un recuit permet de résorber les modifications structurales et retrouver, en majorité, les propriétés originales des SWNT. La température de défonctionnalisation varie selon le type de greffons, mais ne semble pas affectée par le diamètre des nanotubes (diamètre examinés : dérivés phényles, Ømoyen= 0,81 nm, 0,93 nm et 1,3 nm; dérivés dichlorométhylènes, Ømoyen = 0,81 nm et 0,93 nm). Quatrièmement, la polyvalence et la réversibilité de la fonctionnalisation covalente par des unités phényles sont exploitées afin de développer une méthode d’assemblage de réseaux de SWNT. Celle-ci, basée sur l’établissement de forces électrostatiques entre les greffons des SWNT et le substrat, est à la fois efficace et sélective quant à l’emplacement des SWNT sur le substrat. Son application à la fabrication de dispositifs électroniques est réalisée. Finalement, la fonctionnalisation covalente par des groupements phényles est appliquée aux nanotubes de carbone à double paroi (DWNT). Une étude spectroscopique montre que cette dernière s’effectue exclusivement sur la paroi externe. De plus, il est démontré que la signature électrique des DWNT avant et après la fonctionnalisation par des groupements phényles est caractéristique de l’agencement nanotube interne@ nanotube externe.
Resumo:
Ce mémoire décrit la synthèse, la caractérisation spectroscopique et l’étude de la réactivité catalytique d’une nouvelle série de complexes pinceurs de Ni(II) formés à partir du ligand POCOPPh (P,C,P-2,6-{Ph2PO}2C6H4), très peu étudié dans le cas du nickel. Les études décrites dans ce mémoire examinent l’effet des substituants des phosphines sur les propriétés spectroscopiques et électrochimiques ainsi que les activités catalytiques. La synthèse du ligand a été améliorée par rapport à la procédure connue dans la littérature en diminuant le temps de réaction à 30 min et la température jusqu'à température ambiante. Les composés pinceur (P,C,P-2,6-{Ph2PO}2C6H3)NiX ont été obtenus avec des rendements variant entre 60% et 88%. Le premier complexe a été synthétisé en faisant réagir le précurseur NiBr2(NCCH3)x avec le ligand POCOPPh pour donner (POCOPPh)NiBr. Ce dernier réagit par la suite avec les sels d’argent et de potassium pour donner 4 nouveaux complexes soient : (POCOPPh)NiCN, (POCOPPh)NiOTf, (POCOPPh)NiOAc et (POCOPPh)NiONO2 (OTf = triflate et OAc = acetate). Vu la réactivité limitée du dérivé bromure, le dérivé (POCOPPh)NiOTf a été utilisé pour la préparation du composé (POCOPPh)NiCCPh. Le dérivé Ni-OTf a été utilisé également pour la synthèse des complexes (POCOPPh)NiR qui ont été détectés par RMN. Ces complexes (POCOPPh)NiR ont montré une stabilité trop faible et donnent des nouveaux complexes de type (POCOPPh)NiX en échangeant l’halogène avec le Mg ou de type (POCOPPh)NiOH en s’hydrolysant. Les espèces cationiques [(POCOPPh)NiNCR][OTf] (R= Me, CHCH2, CHCHMe, C(Me)CH2, NCCH2CH2N(Ph)H) ont été obtenues facilement et avec des bon rendements à partir du (POCOPPh)NiOTf. Tous les composés obtenus ont été caractérisés par la spectroscopie RMN (1H, 13C{1H}, 31P{1H}, 19F{1H}), la spectroscopie IR et la spectroscopie UV-vis. L’analyse élémentaire et l’analyse par la diffraction des rayons X, dont le but est de résoudre la structure à l’état solide, ont été utilisées pour la plupart des complexes. Des études de voltampérométrie cyclique ont été menées pour déterminer la densité électronique des centres métalliques et l’effet des phosphines sur cette propriété électrochimique. Dans le but de déterminer l’effet des substituants des phosphines sur l’activité catalytique des complexes, nous avons évalué les réactivités catalytiques des deux complexes (POCOPPh)NiOTf et (POCOPi-Pr)NiOTf dans la réaction d’hydroamination des oléfines activés et plus spécifiquement l’acrylonitrile. Après optimisation des conditions expérimentales, on a constaté que la réactivité des deux composés sont similaires mais une grande différence apparaît après l’ajout des additifs. En effet, le complexe (POCOPi-Pr)NiOTf donne une bonne activité catalytique en présence de la triéthylamine, tandis que cette activité diminue considérablement en présence d’eau, contrairement au complexe (POCOPPh)NiOTf qui est plus actif en présence d’eau. Dans le cas du complexe (POCOPPh)NiOTf, on a pu montrer que la base se coordonne au nickel dans le produit formé après la réaction d’hydroamination, ce qui diminue l’activité de ce complexe dans certains cas. Également on a exploré la réaction de l’addition du lien O-H sur l’acrylonitrile, et étonnamment le complexe (POCOPPh)NiOTf est beaucoup plus actif que son homologue (POCOPi-Pr)NiOTf dans le cas des alcools aromatiques. Par contre, les alcools aliphatiques restent un défi majeur pour ce genre de complexe. Le mécanisme de cette réaction qui a été proposé montre que l’alcoolyse passe par les deux intermédiaires (POCOPPh)NiOAr et [(POCOPPh)NiOAr][HOAr] mais l’isolation de ces intermédiaires observés par RMN semble être difficile.
Resumo:
Cette thèse porte sur la capacité à détecter des compagnons de faible intensité en présence de bruit de tavelures dans le contexte de l’imagerie à haute gamme dynamique pour l’astronomie spatiale. On s’intéressera plus particulièrement à l’imagerie spectrale différentielle (ISD) obtenue en utilisant un étalon Fabry-Pérot comme filtre accordable. Les performances d’un tel filtre accordable sont présentées dans le cadre du Tunable Filter Imager (TFI), instrument conçu pour le télescope spatial James Webb (JWST). La capacité de l’étalon à supprimer les tavelures avec ISD est démontrée expérimentalement grâce à un prototype de l’étalon installé sur un banc de laboratoire. Les améliorations de contraste varient en fonction de la séparation, s’étendant d’un facteur 10 pour les séparations supérieures à 11 lambda/D jusqu’à un facteur 60 à 5 lambda/D. Ces résultats sont cohérents avec une étude théorique qui utilise un modèle basé sur la propagation de Fresnel pour montrer que les performances de suppression de tavelures sont limitées par le banc optique et non pas par l’étalon. De plus, il est démontré qu’un filtre accordable est une option séduisante pour l’imagerie à haute gamme dynamique combinée à la technique ISD. Une seconde étude basée sur la propagation de Fresnel de l’instrument TFI et du télescope, a permis de définir les performances de la technique ISD combinée avec un étalon pour l’astronomie spatiale. Les résultats prévoient une amélioration de contraste de l’ordre de 7 jusqu’à 100, selon la configuration de l’instrument. Une comparaison entre ISD et la soustraction par rotation a également été simulée. Enfin, la dernière partie de ce chapitre porte sur les performances de la technique ISD dans le cadre de l’instrument Near-Infrared Imager and Slitless Spectrograph (NIRISS), conçu pour remplacer TFI comme module scientifique à bord du Fine Guidance Sensor du JWST. Cent quatre objets localisés vers la région centrale de la nébuleuse d’Orion ont été caractérisés grâce à un spectrographe multi-objet, de basse résolution et multi-bande (0.85-2.4 um). Cette étude a relevé 7 nouvelles naines brunes et 4 nouveaux candidats de masse planétaire. Ces objets sont utiles pour déterminer la fonction de masse initiale sous-stellaire et pour évaluer les modèles atmosphériques et évolutifs futurs des jeunes objets stellaires et sous-stellaires. Combinant les magnitudes en bande H mesurées et les valeurs d’extinction, les objets classifiés sont utilisés pour créer un diagramme de Hertzsprung-Russell de cet amas stellaire. En accord avec des études antérieures, nos résultats montrent qu’il existe une seule époque de formation d’étoiles qui a débuté il y a environ 1 million d’années. La fonction de masse initiale qui en dérive est en accord avec des études antérieures portant sur d’autres amas jeunes et sur le disque galactique.
Resumo:
Alors que l’Imagerie par résonance magnétique (IRM) permet d’obtenir un large éventail de données anatomiques et fonctionnelles, les scanneurs cliniques sont généralement restreints à l’utilisation du proton pour leurs images et leurs applications spectroscopiques. Le phosphore jouant un rôle prépondérant dans le métabolisme énergétique, l’utilisation de cet atome en spectroscopie RM présente un énorme avantage dans l’observation du corps humain. Cela représente un certain nombre de déEis techniques à relever dus à la faible concentration de phosphore et sa fréquence de résonance différente. L’objectif de ce projet a été de développer la capacité à réaliser des expériences de spectroscopie phosphore sur un scanneur IRM clinique de 3 Tesla. Nous présentons ici les différentes étapes nécessaires à la conception et la validation d’une antenne IRM syntonisée à la fréquence du phosphore. Nous présentons aussi l’information relative à réalisation de fantômes utilisés dans les tests de validation et la calibration. Finalement, nous présentons les résultats préliminaires d’acquisitions spectroscopiques sur un muscle humain permettant d’identiEier les différents métabolites phosphorylés à haute énergie. Ces résultats s’inscrivent dans un projet de plus grande envergure où les impacts des changements du métabolisme énergétique sont étudiés en relation avec l’âge et les pathologies.