984 resultados para Reliability index (RI)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Analyze, in patients with primary hyperhidrosis (PH) who was undergone to videothoracoscopic sympathicotomy, the degree of vascular denervation after surgical transection of the thoracic sympathetic chain by measuring ultrasonografic parameters in carotid and vertebral arteries. Methods: Twenty-four patients with PH underwent forty-eight endoscopic thoracic sympathicotomy and were evaluated by duplex eco-doppler measuring systolic peak velocity (SPV), diastolic peak velocity (DPV), pulsatility index (PI) and resistivity index (RI) in bilateral common, internal and external carotids, besides bilateral vertebral arteries. The exams were performed before operations and a month later. Wilcoxon test was used to analyse the differences between the variables before and after the sympatholisis. Results: T3 sympathicotomy segment was the most frequent transection done (95,83%), as only ablation (25%) or in association with T4 (62,50%) or with T2 (8,33%). It was observed increase in RI and PI of the common carotid artery ( p<0,05). The DPV of internal carotid artery decreased in both sides (p<0,05). The SPV and the DPV of the right and left vertebral arteries also increased (p<0,05). Asymmetric findings were observed so that, arteries of the right side were the most frequently affected. Conclusions: Hemodynamic changes in vertebral and carotid arteries were observed after sympathicotomy for PH. SPV was the most often altered parameter, mostly in the right side arteries, meaning significant asymmetric changes in carotid and vertebral vessels. Therefore, the research findings deserve further investigations to observe if they have clinical inferences

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The optimized allocation of protective devices in strategic points of the circuit improves the quality of the energy supply and the system reliability index. This paper presents a nonlinear integer programming (NLIP) model with binary variables, to deal with the problem of protective device allocation in the main feeder and all branches of an overhead distribution circuit, to improve the reliability index and to provide customers with service of high quality and reliability. The constraints considered in the problem take into account technical and economical limitations, such as coordination problems of serial protective devices, available equipment, the importance of the feeder and the circuit topology. The use of genetic algorithms (GAs) is proposed to solve this problem, using a binary representation that does (1) or does not (0) show allocation of protective devices (reclosers, sectionalizers and fuses) in predefined points of the circuit. Results are presented for a real circuit (134 busses), with the possibility of protective device allocation in 29 points. Also the ability of the algorithm in finding good solutions while improving significantly the indicators of reliability is shown. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: investigar a presença e resultados de malformações vasculares uterinas (MAVU) após doença trofoblástica gestacional (DTG). MÉTODOS: estudo retrospectivo com inclusão de casos diagnosticados entre 1987 e 2004; 2764 pacientes após DTG foram acompanhadas anualmente com ultra-sonografia transvaginal e Doppler colorido no Centro de Neoplasia Trofoblástica Gestacional da Santa Casa da Misericórdia (Rio de Janeiro, RJ, Brasil). Sete pacientes tiveram diagnóstico final de MAVU baseado em análise ultra-sonográfica - índice de pulsatilidade (IP), índice de resistência (IR) e velocidade sistólica máxima (VSM) - e achados de imagens de ressonância nuclear magnética (RNM). Dosagens negativas de beta-hCG foram decisivas para estabelecer o diagnóstico diferencial com DTG recidivante. RESULTADOS: a incidência de MAVU após DTG foi 0,2% (7/2764). Achados ultra-sonográficos de MAVU: IP médio de 0,44±0,058 (extremos: 0,38-0,52); IR médio de 0,36±0,072 (extremos: 0,29-0,50); VSM média de 64,6±23,99 cm/s (extremos: 37-96). A imagem de RNM revelou útero aumentado, miométrio heterogêneo, espaços vasculares tortuosos e vasos parametriais com ectasia. A apresentação clínica mais comum foi hemorragia transvaginal, presente em 52,7% (4/7) dos casos. Tratamento farmacológico com 150 mg de acetato de medroxiprogesterona foi empregado para controlar a hemorragia, após a estabilização hemodinâmica. Permanecem as pacientes em seguimento, assintomáticas até hoje. Duas pacientes engravidaram com MAVU, com gestações e partos exitosos. CONCLUSÃO: presente sangramento transvaginal em pacientes com beta-hCG negativo e história de DTG, deve-se considerar a possibilidade de MAVU e solicitar avaliação ultra-sonográfica com dopplervelocimetria. O tratamento conservador é a melhor opção na maioria dos casos de MAVU pós-DTG.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, an expert and interactive system for developing protection system for overhead and radial distribution feeders is proposed. In this system the protective devices can be allocated through heuristic and an optimized way. In the latter one, the placement problem is modeled as a mixed integer non-linear programming, which is solved by genetic algorithm (GA). Using information stored in a database as well as a knowledge base, the computational system is able to obtain excellent conditions of selectivity and coordination for improving the feeder reliability indices. Tests for assessment of the algorithm efficiency were carried out using a real-life 660-nodes feeder. © 2006 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work proposes a methodology for optimized allocation of switches for automatic load transfer in distribution systems in order to improve the reliability indexes by restoring such systems which present voltage classes of 23 to 35 kV and radial topology. The automatic switches must be allocated on the system in order to transfer load remotely among the sources at the substations. The problem of switch allocation is formulated as nonlinear constrained mixed integer programming model subject to a set of economical and physical constraints. A dedicated Tabu Search (TS) algorithm is proposed to solve this model. The proposed methodology is tested for a large real-life distribution system. © 2011 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was evaluate the renal hemodynamics of bitches with pyometra by means of laboratory tests, ultrasound B mode and Doppler, before and after treatment with ovariohysterectomy (OSH). This study evaluated 30 bitches with pyometra, all were subjected to OSH (moment 1) and 20 were evaluated after 7 days (moment 2). The renal perfusion, the resistivity index (RI) of the main renal artery and the interlobar arteries (cranial, middle and caudal) were statistically different between times 1 and 2 (p<0,05). There was no statistical difference for renal perfusion between the left and the right kidney at the time 1 and 2. The correlations between the IR of the main artery and the variables used to determine renal function were stablished at the time 1. For the correlated variables: urea, creatinine, proteinuria, ratio GGT/creatinine and protein/creatinine were curvilinear and positive associations with the resistivity index of the main renal artery (p<0,05), however these correlations were considered medium and weak. Comparing the RI of the main renal artery with different scores of dehydration and renal perfusion, there was statistical difference, and show increased of resistance renal in bitches with moderate reduction in renal perfusion as well as in dehydrated bitches. Were evaluated several features of renal morphology in ultrasound B mode, however, only the presence of pelvic dilatation, medullary signal and other changes as infarcts areas and diffuse hyperechoic spots in the renal cortical and medullary were statistically different from one moment to the other, most frequently at the time 2. The results of this study show that the Doppler ultrasound can identify changes of reduction in renal perfusion by color Doppler and the increasing of the resistivity index of the renal arteries in some bitches with pyometra. As well as, the ultrasound B mode, although has non-specific changes, can detect progressive renal disorders in bitches with pyometra.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB