1000 resultados para Redução da dose de radiação


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In radiotherapy, computational systems are used for radiation dose determination in the treatment’s volume and radiometric parameters quality analysis of equipment and field irradiated. Due to the increasing technological advancement, several research has been performed in brachytherapy for different computational algorithms development which may be incorporated to treatment planning systems, providing greater accuracy and confidence in the dose calculation. Informatics and information technology fields undergo constant updating and refinement, allowing the use Monte Carlo Method to simulate brachytherapy source dose distribution. The methodology formalization employed to dosimetric analysis is based mainly in the American Association of Physicists in Medicine (AAPM) studies, by Task Group nº 43 (TG-43) and protocols aimed at dosimetry of these radiation sources types. This work aims to analyze the feasibility of using the MCNP-5C (Monte Carlo N-Particle) code to obtain radiometric parameters of brachytherapy sources and so to study the radiation dose variation in the treatment planning. Simulations were performed for the radiation dose variation in the source plan and determined the dosimetric parameters required by TG-43 formalism for the characterization of the two high dose rate iridium-192 sources. The calculated values were compared with the presents in the literature, which were obtained with different Monte Carlo simulations codes. The results showed excellent consistency with the compared codes, enhancing MCNP-5C code the capacity and viability in the sources dosimetry employed in HDR brachytherapy. The method employed may suggest a possible incorporation of this code in the treatment planning systems provided by manufactures together with the equipment, since besides reducing acquisition cost, it can also make the used computational routines more comprehensive, facilitating the brachytherapy ...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Radiotherapy is a branch of medical physics related to the treatment of malignant neoplasm, being an important instrument in the fight against cancer, when combined with the effort of a multidisciplinary team, composed of, physicians, physicists, nurses and technicians. Every year more than 3.5 million new cases of cancer are recorded in the world, being the prostate cancer responsible for approximately 25% of this amount (INCA and IARC, 2008). In this type of cancer, radiotherapy is a method indicated for treatement. The technological advance in this area over years has allowed a greater accuracy in the tumor location, more conformation of the radiation beam around the tumor, reducing the dose in healthy tissues and a consequent dose increase on treatment (Bedford et al., 1999). A radiotherapy planning, in which the physicist develops an important role, is composed of several steps, including choosing the best configuration of treatment beams. This choice has a close relationship with success of therapy and is critical to achieve the best distribution of dose inside the tumor and expose the least as possible the healthy tissue to radiation. In this work, two options for setting up camps in the first phase in a treatment of prostate cancer were simulated in computer planning: 4 fields orthogonal or “Box” with gantry angles in 00, 1800, 2700 e 90° and 4 fields angled or “X” (1350, 450, 3150 e 2250). The percentage of the rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5% respectively (Greco et al., 2003). The femoral toxicity have limited dose by 70% of the total dose prescribed in a prostate treatment (Bedford et al., 1999). The planning of 27 patients with prostate adenocarcinoma submitted to 3D conformal radiotherapy were accompanied. As a result, it was assessed that the best TCP (tumor control probability)... (Complete abstract click electronic access below)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O trabalho propõe rotinas computacionais usando o Método de Monte Carlo com o Código MCNP-5, para analisar os perfis de dose de radiação liberada nos tratamentos de tumores de pele e otimizar os cálculos radiométricos dos feixes de radiação estudados. Foram realizadas medidas dosimétricas do feixe de radiação, comparando os resultados obtidos com os respectivos valores fornecidos pelo serviço de física médica das instituições, com resultados informados pelo fabricante do equipamento e com as simulações computacionais efetuadas com o Código MCNP-5. A quantificação dos erros relativos percentual entre os resultados simulados e os fornecidos pelo Serviço de Radioterapia (E1), os informados pelo fabricante (E2) e os medidos experimentalmente (E3) são inferiores a 4,0% e validam a metodologia computacional proposta para avaliação do comportamento do feixe de raios-X superficial e do feixe de raios γ da unidade de Cobaltoterapia. A metodologia de análise do espectro energético e da curva de porcentagem de dose profunda (PDP) desenvolvida neste trabalho pode ser estendida para estudos de outros feixes clínicos e subsidiar os dados radiométricos utilizados nos planejamentos e cálculos de dose realizados pelo profissional da física médica na sua rotina nos Serviços de Radioterapia

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

As flores de Bauhinia variegata var candida apresentam coloração branca e são vulgarmente conhecidas como “patas de vaca branca”, sendo muito utilizadas na cozinha gourmet como forma de aumentar a qualidade sensorial e nutricional dos alimentos [1,2]. No presente estudo, as flores foram submetidas a radiação por feixe de eletrões em diferentes doses (0,5 e 0,8 kGy) como forma de descontaminação, e seguidamente analisadas em termos de parâmetros nutricionais (humidade, proteínas, gordura, hidratos de carbono e cinzas) e perfis em açúcares livres (HPLCRI), ácidos gordos (GC-FID), tocoferóis (HPLC-Fluorescência) e ácidos orgânicos (HPLC-DAD). As amostras não irradiadas e irradiadas mostraram um perfil nutricional semelhante, sendo os hidratos de carbono os nutrientes mais abundantes, seguidos das proteínas, gorduras e cinzas. Os perfis em açúcares foram também similares, estando presente a frutose em maior quantidade, seguida da glucose e da sacarose. Os ácidos mirístico (C14:0), palmítico (C16:0), esteárico (C18:0) e oleico (C18:1n9), foram os ácidos gordos mais abundantes. Os ácidos gordos saturados (SFA) foram os mais abundantes, seguidos dos mono (MUFA) e polinsaturados (PUFA). Neste caso, com maior dose de radiação verificou-se que a percentagem de SFA e MUFA diminui ligeiramente (principalmente pelo aumento dos ácidos esteárico e oleico, respetivamente), aumentando a percentagem de PUFA (principalmente pelo aumento dos ácidos linoleico e α-linolénico). No que respeita aos tocoferóis, só a isoforma α foi encontrada, apresentando aproximadamente o mesmo conteúdo nas amostras irradiadas e não irradiadas (1,75±0,06 mg/mL). O ácido cítrico foi o ácido orgânico mais abundante nas amostras, seguido dos ácidos: málico, ascórbico, oxálico e fumárico. Também neste caso os valores mantiveram-se, com exceção do ácido cítrico que aumentou ligeiramente com as doses de irradiação (55,94, 61,70 e 67,64 mg/mL, respetivamente). Em síntese, verificou-se que as doses de irradiação aplicadas não alteraram significativamente a composição química das amostras em estudo, e pode ser considerada uma técnica de descontaminação e preservação de flores comestíveis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB), porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A common side effect of radiotherapy used in the treatment of oral cancer is the occurrence of structural and physiological alterations of the salivary glands due to exposure to ionizing radiation, as demonstrated by conditions such as decreased salivary flow. The present study evaluated ultrastructural alterations in the parotid glands of rats receiving a fractionated dose (1,500-cGy) of radiation emitted by a Cesium-137 source and rats that were not subjected to ionizing radiation. After sacrifice, the parotid glands were removed and examined by transmission electron microscopy. Damage such as cytoplasmic vacuolization, dilatation of the endoplasmic reticulum and destruction of mitochondria, as well as damage to the cellular membrane of acinar cells, were observed. These findings lead to the conclusion that ionizing radiation promotes alterations in the glandular parenchyma, and that these alterations are directly related to the dose level of absorbed radiation. Certain phenomena that appear in the cytoplasm and nuclear material indicate that ionizing radiation causes acinar cell death (apoptosis).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivo – Comparar a técnica convencional, a técnica de energias mistas e a técnica field-in-field com energias mistas, verificando a dose recebida nos órgãos de risco e no volume alvo. Metodologia – Quinze doentes com carcinoma da mama esquerda classificadas de T1-T3N0M0 foram tratadas com cirurgia conservadora da mama, seguida de radioterapia pós-operatória. Para cada doente realizaram-se 3 planeamentos dosimétricos, sendo que cada um deles diz respeito a uma das diferentes técnicas em estudo. Através dos HDV gerados avaliaram-se a Dmáx, Dmed, Dmín, D95%, D3% e a homogeneidade da dose no volume alvo, bem como a dose nos órgãos de risco. Utilizou-se o teste de Friedman para verificar a significância do estudo, com um intervalo de confiança de 95%. Resultados – Relativamente ao pulmão esquerdo e ao coração obtiveram-se, com a técnica field-in-field com energias mistas, doses inferiores em comparação com as outras duas técnicas. Para a Dmáx e a homogeneidade de dose no PTV, a técnica field-in-field com energias mistas revelou-se mais eficaz, comparativamente às outras técnicas. No entanto, verificou-se uma melhor cobertura de dose no PTV com a técnica convencional. Considerações finais – A técnica field-in-field com energias mistas permite uma redução da dose nos órgãos de risco, uma redução significativa da Dmáx no PTV e melhora a homogeneidade da dose, comparativamente com as outras técnicas. Os resultados obtidos com a técnica field-in-field com energias mistas apontam para a redução dos efeitos secundários provocados pelo tratamento. ABSTRACT - Purpose – To compare the conventional technique, the technique of mixed energies and the technique field-in-field with mixed energies, checking the received dose in organs at risk and target volume. Methods – Fifteen patients with carcinoma of the left breast classified as T1-T3N0M0 were treated with breast-conserving surgery, followed by postoperative radiotherapy. For each patient were carried out three dosimetric plannings, each one of them concerns the different techniques under study. Through the DVH generated to evaluate Dmax, Dmed, Dmin, D95%, D3% and the homogeneity of the target volume dose, well as the dose in organs at risk. We used the Friedman test to assess the significance of the study, with a confidence interval of 95%. Results – For the left lung and heart were obtained with the technique field-in-field with mixed energies, lower doses compared with the other two techniques. For the Dmax and the homogeneity of the PTV dose, the technique field-in-field with mixed energies was more effective compared to other techniques. However, there was a better coverage of the PTV dose with conventional technique. Conclusions – The technique field-in-field with mixed energy allows a reduction in dose for organs at risk, a significant reduction Dmax in PTV and improves the homogeneity of the dose compared with other techniques. The results obtained with the technique field-in-field with mixed energy indicate to reduce the side effects caused by the treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Proteção contra Radiações.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Proteção Contra Radiações

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A importância da radiação ionizante na prática médica, nãoo só como diagnóstico mas também como terapia, ganhou, no último meio século, uma importância fulcral. Devido aos efeitos secundários da radiação ao ser humano, torna-se fundamental definir regras para aumentar a segurança de todos os seus utilizadores, surgindo assim a radioprotecção. Nesse sentido a Comunidade Europeia da Energia Atómica (EURATOM) define directrizes para os países membros da Comunidade Europeia de forma a poder orientá-los nesse processo. Torna-se assim importante registar e monitorizar os valores de dose de radiação num exame radiológico para o aumento de segurança dos pacientes e técnicos. O presente trabalho desenvolvido no âmbito da disciplina anual Dissertação/Projecto/ Estágio Profissional do Mestrado em Computação e Instrumentação Médica teve como objectivo registar esses valores através da comunicação com medidores de doses. A luz do dia-a-dia da Dr. Campos Costa - Consultório de Tomogra a Computarizada S.A, é apresentada nesta tese uma aplicação computacional capaz de obter os valores de dose de um estudo radiológico a um paciente e guardá-los numa base de dados projectada exclusivamente para esse fim. Os resultados obtidos são animadores uma vez que provam ser possível automatizar a monitorização desses valores através de aplicações com ferramentas capazes de auxiliar os responsáveis por essa monitorização em qualquer centro clínico.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às tecnologias da Saúde