124 resultados para Reciprocating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct-drive linear reciprocating compressors offer numerous advantages over conventional counterparts which are usually driven by a rotary induction motor via a crank shaft. However, to ensure efficient and reliable operation under all conditions, it is essential that motor current of a linear compressor follows a sinusoidal current command with a frequency which matches the system resonant frequency. The design of a high-performance current controller for linear compressor drive presents a challenge since the system is highly nonlinear, and an effective solution must be low cost. In this paper, a learning feed-forward current controller for the linear compressors is proposed. It comprises a conventional feedback proportional-integral controller and a feed-forward B-spline neural network (BSNN). The feed-forward BSNN is trained online and in real time in order to minimize the current tracking error. Extensive simulation and experiment results with a prototype linear compressor show that the proposed current controller exhibits high steady state and transient performance. © 2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scalable synthetic muscle has been constructed that transducts nanoscale molecular shape changes into macroscopic motion. The working material, which deforms affinely in response to a pH stimulus, is a self-assembled block copolymer comprising nanoscopic hydrophobic domains in a weak polyacid matrix. A device has been assembled where the muscle does work on a cantilever and the force generated has been measured. When coupled to a chemical oscillator this provides a free running chemical motor that generates a peak power of 20 mW kg 1 by the serial addition of 10 nm shape changes that scales over 5 orders of magnitude. It is the nanostructured nature of the gel that gives rise to the affine deformation and results in a robust working material for the construction of scalable muscle devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct-drive linear reciprocating compressors offer numerous advantages over conventional counterparts which are usually driven by a rotary induction motor via crank shaft However, to ensure efficient and reliable operation under all conditions, it is essential that the motor current of the linear compressor follows a sinusoidal command profile with a frequency which matches the system resonant frequency. This paper describes a hybrid current controller for the linear compressors. It comprises a conventional proportional-integral (PI) controller, and a B-spline neural network compensator which is trained on-line and in real-time in order to minimize the current tracking error under all conditions with uncertain disturbances. It has been shown that the hybrid current controller has a superior steady-state and transient performance over the conventional carrier based PI controller. The performance of the proposed hybrid controller has been demonstrated by extensive simulations and experiments. It has also been shown that the linear compressor operates stably under the current feedback control and the piston stroke can be adjusted by varying the amplitude of the current command. © 2007 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the effectiveness of Reciproc for the removal of cultivable bacteria and endotoxins from root canals in comparison with multifile rotary systems. The root canals of forty human single-rooted mandibular pre-molars were contaminated with an Escherichia coli suspension for 21 days and randomly assigned to four groups according to the instrumentation system: GI - Reciproc (VDW); GII - Mtwo (VDW); GIII - ProTaper Universal (Dentsply Maillefer); and GIV -FKG Race(™) (FKG Dentaire) (n = 10 per group). Bacterial and endotoxin samples were taken with a sterile/apyrogenic paper point before (s1) and after instrumentation (s2). Culture techniques determined the colony-forming units (CFU) and the Limulus Amebocyte Lysate assay was used for endotoxin quantification. Results were submitted to paired t-test and anova. At s1, bacteria and endotoxins were recovered in 100% of the root canals investigated (40/40). After instrumentation, all systems were associated with a highly significant reduction of the bacterial load and endotoxin levels, respectively: GI - Reciproc (99.34% and 91.69%); GII - Mtwo (99.86% and 83.11%); GIII - ProTaper (99.93% and 78.56%) and GIV - FKG Race(™) (99.99% and 82.52%) (P < 0.001). No statistical difference were found amongst the instrumentation systems regarding bacteria and endotoxin removal (P > 0.01). The reciprocating single file, Reciproc, was as effective as the multifile rotary systems for the removal of bacteria and endotoxins from root canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanical and tribological properties of a partially crystallized sintered glass-ceramic were compared to two commercial floor tiles: black granite and porcelainized stoneware. Mechanical properties, hardness and elastic modulus were evaluated by instrumented indentation. Friction coefficient and wear characterization were evaluated using a reciprocating ball-on-flat tribometer in two controlled environments: air with relative humidity of 53% and under running water at 23 degrees C. The sintered glass-ceramic and porcelainized stoneware presented similar mechanical and tribological properties. Regarding the mechanical and tribological properties, the results suggest that this glass-ceramic is suitable to be used as industrial tile. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The differential diagnosis in children who walk on their toes includes mild spastic diplegia and idiopathic toe walking (ITW). A diagnosis of ITW is often one of exclusion. To better characterize the diagnosis of ITW, quantitative gait analysis was utilized in a series of patients with an established diagnosis of ITW. Study Design: Patients with an established diagnosis of ITW were analyzed by quantitative gait analysis. Data were recorded as each subject walked in a self-selected toe-walking pattern. The subject was then asked to ambulate making every effort to walk in a normal heel-toe reciprocating fashion. Data were collected to determine if this group of idiopathic toe walkers was able to normalize their gait. Data sets were compared with each other and with historical normal controls. Results: Fifty-one neurologically normal children ( 102 extremities) with ITW were studied in the Motion Analysis Laboratory at a mean age of 9.3 years. In the self-selected trials, significant deviations in both kinematics and kinetics at the level of the ankle were identified. Disruption of all 3 ankle rockers and a plantar flexion bias of the ankle throughout the gait cycle were most commonly seen. When asked to attempt a normal heel-toe gait, 17% of the children were able to normalize both stance and swing variables. In addition, 70% were able to normalize some but not all of the stance and swing variables. Conclusion: Quantitative gait analysis is an effective tool for differentiating mild cerebral palsy from ITW. Kinematic and kinetic distinctions between the diagnoses are evident at the knee and ankle. The ability to normalize on demand at least some of the kinematic and kinetic variables associated with toe walking is seen in most children with ITW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The tribological response of multilayer micro/nanocrystalline diamond coatings grown by the hot filament CVD technique is investigated. These multigrade systems were tailored to comprise a starting microcrystalline diamond (MCD) layer with high adhesion to a silicon nitride (Si3N4) ceramic substrate, and a top nanocrystalline diamond (NCD) layer with reduced surface roughness. Tribological tests were carried out with a reciprocating sliding configuration without lubrication. Such composite coatings exhibit a superior critical load before delamination (130–200 N), when compared to the mono- (60–100 N) and bilayer coatings (110 N), considering ∼10 µm thick films. Regarding the friction behaviour, a short-lived initial high friction coefficient was followed by low friction regimes (friction coefficients between 0.02 and 0.09) as a result of the polished surfaces tailored by the tribological solicitation. Very mild to mild wear regimes (wear coefficient values between 4.1×10−8 and 7.7×10−7 mm3 N−1 m−1) governed the wear performance of the self-mated multilayer coatings when subjected to high-load short-term tests (60–200 N; 2 h; 86 m) and medium-load endurance tests (60 N; 16 h; 691 m).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A taquicardia juncional recíproca permanente é uma forma de taquicardia supraventricular de reentrada pouco comum, embora constitua a causa mais frequente de taquicardia incessante em crianças. O seu carácter permanente causa disfunção ventricular esquerda e miocardiopatia dilatada e é de difícil controlo terapêutico. Objectivo: Rever as características clínicas mais significativas desta arritmia, a sua evolução e as opções terapêuticas actuais. Métodos: estudo retrospectivo, analisando a forma de apresentação e evolução, com particular relevo para a resposta à terapêutica farmacológica e alternativas terapêuticas. Doentes: Grupo de 5 doentes com o diagnóstico de taquicardia juncional recíproca permanente. Resultados: As crianças estudadas tinham idades compreendidas entre os 14 dias e os 12 anos. Três encontravam-se assintomáticas. O primeiro ecocardiograma demonstrou dilatação do ventrículo esquerdo e diminuição da fracção de encurtamento em uma das crianças. A terapêutica farmacológica foi inicialmente eficaz em todos os casos. Ao longo do seguimento (0,2-4,5 anos) a arritmia tornou-se refractária em um dos casos, pelo que se procedeu a ablação da via anómala por radiofrequência. Conclusões: A taquicardia juncional recíproca permanente tem diversas formas de apresentação. A terapêutica farmacológica é recomendada, mas tem carácter transitório. A ablação por radiofrequência é o tratamento definitivo, estando condicionada pela idade dos doentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia e Gestão Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica