938 resultados para RING POLYAROMATIC HYDROCARBONS
Resumo:
A comparison is made between the structures and calcium binding properties of four cyclic octapeptides that differ in the number of heterocyclic thiazole and oxazoline ring constraints. The conformations of the naturally occurring cyclic octapeptides ascidiacyclamide 1 and patellamide D 2, which each contain two oxazoline and two thiazole rings, are compared by H-1 NMR spectroscopy with the analogues cyclo(Thr-D-Val(Thz)-Ile)(2) 3 with just two thiazoles, and cyclo(Thr-D-Val-alpha Abu-Ile)(2) 4, with no 5-membered rings. The conformations observed in the solid state for ascidiacyclamide (saddle) and patellamide D (twisted figure of eight) were retained in solution, whilst peptide 3 was found to have a chair shape and peptide 4 displayed a range of conformations. The solid state structure of 4 revealed that the peptide takes a relatively planar conformation with a number of transannular hydrogen bonds, which are apparently retained in solution. Complexation studies utilising H-1 NMR and CD spectroscopy yielded 1∶1 calcium-peptide binding constants (log K) for the four peptides (2.9 (1), 2.8 (2), 4.0 (3) and 5.5 (4)) as well as a 1 : 2 metal-peptide binding constant for 3 (log K = 4.5). The affinity for Ca2+ thus decreases with increasing number of 5-membered ring constraints in the macrocycle (4 > 3 > 2 approximate to 1).
Resumo:
The structures of diaqua(1,7-dioxa-4-thia-10-azacyclododecane)nickel dinitrate, [Ni(C8H17NO2S)(H2O)(2)](NO3)(2), (I), bis(nitrato-O,O')(1,4,7-trioxa-10-azacyclododecane)mercury, [Hg(NO3)(2)(C8H17NO3)], (II), and aqua(nitrato-O)(1-oxa-4,7,10-triazacyclododecane)copper nitrate, [Cu(NO3)(C8H19N3O)(H2O)]NO3, (III), reveal each macrocycle binding in a tetradentate manner. The conformations of the ligands in (I) and (III) are the same and distinct from that identified for (II). These differences are in agreement with molecular-mechanics predictions of ligand conformation as a function of metal-ion size.
Resumo:
The salticid spider Cosmophasis bitaeniata preys on the larvae of the green tree ant Oecophylla smaragdina. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) reveal that the cuticle of C. bitaeniata mimics the mono- and dimethylalkanes of the cuticle of its prey. Recognition bioassays with extracts of the cuticular hydrocarbons of ants and spiders revealed that foraging major workers did not respond aggressively to the extracts of the spiders or conspecific nestmates, but reacted aggressively to conspecific nonnestmates. Typically, the ants either failed to react (as with control treatments with no extracts) or they reacted nonaggressively as with conspecific nestmates. These data indicate that the qualitative chemical mimicry of ants by C. bitaeniata allows the spiders to avoid detection by major workers of O. smaragdina.
Resumo:
Partitioning behavior of PAHs including NAP, FLO, PHE, and PYR was investigated. A plot of experimental K-HA against log K-OW gives a good linear relationship. A somewhat similar slope and intercept it-as obtained for the hair-air system using PCB values from the literature. In comparison to K-VA values from the literature, lower values for K-VA were obtained. This may be attributed from differences in species and degradability across biota groups. K-HLA also exhibits good linear relationships with K-OA and other physical chemical properties such as W The lipid fraction has a strong influence on bioconcentration in hair from the air and water. However, hair treatments, hair length, growth dilution, photodegradation, biodegradation, temperature, seasonal variations, wet and dry depositions could alter the degree of bioconcentration of PAHs in the hair.
Resumo:
Sm and Sm-like proteins are key components of small ribonucleoproteins involved in many RNA and DNA processing pathways. In eukaryotes, these complexes contain seven unique Sm or Sm-like (Lsm) proteins assembled as hetero-heptameric rings, whereas in Archaea and bacteria six or seven-membered rings are made from only a single polypeptide chain. Here we show that single Sm and Lsm proteins from yeast also have the capacity to assemble into homo-oligomeric rings. Formation of homo-oligomers by the spliceosomal small nuclear ribonucleoprotein components SmE and SmF preclude hetero-interactions vital to formation of functional small nuclear RNP complexes in vivo. To better understand these unusual complexes, we have determined the crystal structure of the homomeric assembly of the spliceosomal protein SmF. Like its archaeal/bacterial homologs, the SmF complex forms a homomeric ring but in an entirely novel arrangement whereby two heptameric rings form a co-axially stacked dimer via interactions mediated by the variable loops of the individual SmF protein chains. Furthermore, we demonstrate that the homomeric assemblies of yeast Sm and Lsm proteins are capable of binding not only to oligo(U) RNA but, in the case of SmF, also to oligo(dT) single-stranded DNA.
Resumo:
The interaction between a hydrophobically modified 5,10,15,20-tetrakis(4-N-tetradecyl-pyridyl) porphyrin and three phospholipids: two negatively charged, DMPA (the sodium salt of dimyristoyl-sn-glycero-phosphatidyl acid) and DMPG (the sodium salt of 1,2-dimyristoyl-sn-glycero-3-[phospho-rac-(1-glycerol)]) and a zwitterionic DMPC (dimyristoyl-sn-glycero-phosphatidylcholine), were studied by means of surface pressure isotherms and spectroscopic methods. The interaction results in partial or total metallation of the porphyrin with zinc ions in the presence of negatively charged phospholipids, as attested by UV-vis and luminescence spectroscopy of the transferred films. In the presence of the zwitterionic phospholipid no insertion of zinc ion in the porphyrin ring is detected. These results are relevant for the understanding of photosensitizer-lipid-carrier binding for use in photodynamic therapy. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
We report experimental studies of metastable chaos in the far-infrared ammonia ring: laser. When the laser pump power is switched from above chaos threshold to slightly below, chaotic intensity pulsations continue for a varying time afterward before decaying to either periodic or cw emission. The behavior is in good qualitative agreement with that predicted by the Lorenz equations, previously used to describe this laser. The statistical distribution of the duration of the chaotic transient is measured and shown to be in excellent agreement with the Lorenz equations in showing a modified exponential distribution. We also give a brief numerical analysis and graphical visualization of the Lorenz equations in phase space illustrating the boundary between the metastable chaotic and the stable fixed point basins of attraction. This provides an intuitive understanding of the metastable dynamics of the Lorenz equations and the experimental system.
Resumo:
Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)
Resumo:
Bariatric surgery before pregnancy may help prevent obesity-related gestational complications. However, maternal malnutrition is not without potential risks during pregnancy. The objective was to evaluate the influence of time to conception after silastic ring Roux-en-Y gastric bypass (SRYGB) on maternal anemia. Patients who underwent SRYGB for morbid obesity and who subsequently became pregnant were followed up at the prenatal. Thirty pregnancies occurred between July 2001 and September 2009. The patients were analyzed according to time to conception after bariatric surgery: 17 patients with time to conception < 4 years (48 months) and 13 patients with a parts per thousand yen4 years. First trimester hemoglobin levels were significantly lower in patients with time to conception a parts per thousand yen4 years (48 months) (median 9.6 g/dL, range 5.8-13.2 g/dL) than in patients with time to conception < 4 years (median 11.1 g/dL, range 9.8-13.6 g/dL; p = 0.047). The need for intravenous iron therapy or packed red cell transfusion was significantly more frequent among women who became pregnant a parts per thousand yen4 years after SRYGB compared to < 4 years (30.8% vs. 0%, p = 0.026). Pregnancy after 4 years of SRYGB is associated with maternal anemia and the need for more strict iron supplementation.
Resumo:
We present a 20-year follow-up on a patient with a ring chromosome 14. The ring chromosome was studied by fluorescence in-situ hybridization (FISH), multiplex-ligation probe amplification (MLPA), and genome wide SNP array, and no deletions of chromosome 14 were detected, although the telomeric repeat sequence was absent from the ring chromosome. The patient had skeletal abnormalities, and susceptibility to infections, as well as seizures and retinal pigmentation, which are commonly found in individuals with a ring 14. Our patient corroborates the idea that even when no genes are lost during ring formation, a complete ring chromosome can produce phenotypic alterations, which presumably result from ring instability or gene silencing due to the new chromosomal architecture. (C) 2010 Wiley-Liss, Inc.
Resumo:
Grobner bases have been generalised to polynomials over a commutative ring A in several ways. Here we focus on strong Grobner bases, also known as D-bases. Several authors have shown that strong Grobner bases can be effectively constructed over a principal ideal domain. We show that this extends to any principal ideal ring. We characterise Grobner bases and strong Grobner bases when A is a principal ideal ring. We also give algorithms for computing Grobner bases and strong Grobner bases which generalise known algorithms to principal ideal rings. In particular, we give an algorithm for computing a strong Grobner basis over a finite-chain ring, for example a Galois ring.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.