860 resultados para REFRACTIVE ERRORS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To show the importance of the cicloplegic method in the refraction evaluation comparing the automated refraction (subjective and objective) and the subjective static refraction. Method: One-hundred patients (200 eyes) between 5 and 40 years were prospectivelly evaluated according the static and dynamic automated refraction and the subjective static refraction, using an automated refractor Nidek ARK - 900. The data were submitted to statical evaluation. Results: The concordance indices were better after cycloplegia mainly in relation of the spheric degree and cílindric axes. Conclusion: Cycloplegia is very important to have accurace in the automated refraction in patients before 40 year-old.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To analyze the results of recall absent schoolchildren to eye health projects. Methods: Cross-sectional study. Visual screening was performed in schoolchildren attending 1st to 4th grades at public schools, from 7 to 10 years-old, to select and forward to complete ophthalmic evaluation. The projects were performed during weekends, at a public school, in the same municipality. Free transportation, food and eyeglasses were offered. A second opportunity of examination was offered to the students who were absent from the first call, with the same facilities. Results: 51,509 schoolchildren had their vision tested, 14,651 (28.4%) were referred for ophthalmic examination. Of these, 8,683 (59.3%) attended the first call, 2,228 (37.3%) attended the recall and 25.5% of parents did not take their children to ophthalmic examination. The need for eyeglasses for children who attended the examination was 23.8% and 32.0% in the first opportunity and recall, respectively. The recall increased the coverage in 15.2% (59.3% to 74.5%). Conclusion: An expressive number of parents (25.5%) did not bring their children to be examined, even at a second opportunity of exam. The facilities offered: access, free examination, transportation and glasses. Children who were absent in the first opportunity and appeared at recall had a greater need for eyeglasses. Recall increased the coverage in 15.2% (59.3% to 74.5%) and it is not recommended when financial resources are limited.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. Methods: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the Sao Joao da Boa Vista Administrative Region). Results: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. Conclusion: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolandia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. METHODS: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the São João da Boa Vista Administrative Region). RESULTS: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. CONCLUSION: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolândia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enquadramento: O acesso à saúde ocular em escolares dirige primariamente a prevenção de problemas visuais que dificultem o aprendizado, impossibilitando o desenvolvimento das atividades intelectuais e sociais. Os projetos de promoção da saúde oftalmológica são, para a grande maioria dos alunos, a primeira e rara oportunidade de avaliar a visão. Objetivos: Identificar os tipos de déficit visuais mais comuns nas crianças da região metropolitana do Recife; Identificar as queixas mais frequentes relacionadas a baixa de visão; Realizar campanha preventiva para identificação dos déficits, tendo como referência a Guarnição de Aeronáutica de Recife (GAR). Métodos: Estudo descritivo, transversal, intervencionista e quantitativo. A pesquisa ocorreu nos anos de 2013 e 2014, em uma população de 1500 crianças residentes na cidade de Recife, estado de Pernambuco, Brasil, com idades variando entre 7 e 9 anos, onde obtivemos uma amostra de 490 inscrições para participação no programa. Resultados: No primeiro período, atingimos 98,5% de objetividade, aumentando para 99,3% no segundo período. Os estudantes realizaram as consultas maioritariamente pela manhã (58,7%), em escola particular (81,6%) e na sua maioria (57,1%), eram do sexo feminino. A presença de queixas atingiu 78,6% e os sinais e sintomas mais referidos foram: cefaleia (20,8%), prurido ocular (17,6%) e dificuldade de enxergar o quadro (16,8%). Foram identificados e corrigidos 53 casos de erros de refração sendo o astigmatismo (4,74%), o mais diagnosticado, 7 casos de estrabismo e tratados 12 de conjuntivite. Conclusões: Em 2013, 15,1% e em 2014, 14,2% das crianças apresentaram baixa acuidade visual. Astigmatismo e miopia representam 10% dos problemas mais comuns seguidos de hipermetropia e conjuntivite. 84% do total de nossa amostra refere dificuldade de visualização no quadro negro, 68% manifestam cefaleias, 85% dor ocular, 75,5% vermelhidão ocular e 80,3% prurido ocular. Resumindo, os distúrbios visuais são comuns nas crianças, justificando programas de saúde preventiva nas unidades de saúde da FAB. Palavras-chave: Acuidade visual; Criança; Preventiva.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to determine the accuracy (and usability) of the Retinomax, a hand-held autorefractor, compared to measurements taken from hand-held retinoscopy (HHR) in a sample of normal 1-year-old children. The study was a method comparison set at four Community Child Health Clinics. Infants (n = 2079) of approximately 1 year of age were identified from birth/immunization records and their caregivers were contacted by mail. A total of 327 infants ranging in age from 46 weeks to 81 weeks (mean 61 weeks) participated in the study. The children underwent a full ophthalmic examination. Under cycloplegia, refraction was measured in each eye by streak retinoscopy (HHR) and then re-measured using the Retinomax autorefractor. Sphere, cylinder, axis of cylinder and spherical equivalent measurements were recorded for HHR and Retinomax instruments, and compared. Across the range of refractive errors measured, there was generally close agreement between the two examination methods, although the Retinomax consistently read around 0.3 D less hyperopic than HHR. Significantly more girls (72 infants, 47.7%), struggled during examination with the Retinomax than boys (52 infants, 29.5%) (P < 0.001). Agreement deteriorated between the two instruments if the patient struggled during the examination (P < 0.001). In general, the Retinomax would appear to be a useful screening instrument in early childhood. However, patient cooperation affects the accuracy of results and is an important con-sideration in determining whether this screening instrument should be adopted for measuring refractive errors in early infancy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Myopia (short-sightedness) is a visual problem associated with excessive eye growth and vitreous chamber expansion. Within the eye serotonin (5-hydroxytryptamine, 5-HT) appears to have a variety of effects, it alters retinal amacrine cell processing, increases intraocular pressure, constricts ocular blood vessels, and is also mitogenic. This study sought to determine the role of the retinal serotonin system in eye growth regulation. Myopia was produced in 7-day-old chicks using -15 D spectacle lenses (LIM) and form deprivation (FDM). The effect on LIM and FDM of daily intravitreal injections of a combination of 5-HT receptor antagonists (1, 10, 50 mu M), 5-HT2 selective antagonist (Mianserin 0.5, 20 mu M) were assessed. Counts were performed of serotonin and tyrosine hydroxylase positive neurons and the relative density used to account for areal changes due to eye growth. The effect of LIM and lens-induced hyperopia (LIH) on the numbers of 5-HT-containing amacrine cells in the retina were then determined. The combination of the 5-HT receptor antagonists inhibited LIM by approximately half (1 mu M RE: -7.12 +/- 1.0 D, AL: 0.38 +/- 0.06 mm vs. saline RE: -13.19 +/- 0.65 D, AL: 0.64 +/- 0.03 mm. RE: p < 0.01, AL: p < 0.01), whereas FDM was not affected (1 mu M RE: -8.88 +/- 1.10 D). These data suggest that serotonin has a stimulatory role in LIM, although high doses of serotonin were inhibitory (1 mu M RE: -9.30 +/- 1.34 D). 5-HT immunoreactivity was localised to a subset of amacrine cell bodies in the inner nuclear layer of the retina, and to two synaptic strata in the inner plexiform layer. LIM eyes had increased numbers of 5-HT-containing amacrine cells in the central retina (12.5%). Collectively, these results suggest that manipulations to the serotonin system can alter the eye growth process but the role of the transmitter system within this process remains unclear. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To assess the accuracy of three wavefront analyzers versus a validated binocular open-view autorefractor in determining refractive error in non-cycloplegic eyes. METHODS: Eighty eyes were examined using the SRW-5000 open-view infrared autorefractor and, in randomized sequence, three wavefront analyzers: 1) OPD-Scan (NIDEK, Gamagori, Japan), 2) WASCA (Zeiss/Meditec, Jena, Germany), and 3) Allegretto (WaveLight Laser Technologies AG, Erlangen, Germany). Subjects were healthy adults (19 men and 21 women; mean age: 20.8 +/- 2.5 years). Refractive errors ranged from +1.5 to -9.75 diopters (D) (mean: +1.83 +/- 2.74 D) with up to 1.75 D cylinder (mean: 0.58 +/- 0.53 D). Three readings were collected per instrument by one examiner without anticholinergic agents. Refraction values were decomposed into vector components for analysis, resulting in mean spherical equivalent refraction (M) and J0 and J45 being vectors of cylindrical power at 0 degrees and 45 degrees, respectively. RESULTS: Positive correlation was observed between wavefront analyzers and the SRW-5000 for spherical equivalent refraction (OPD-Scan, r=0.959, P<.001; WASCA, r=0.981, P<.001; Allegretto, r=0.942, P<.001). Mean differences and limits of agreement showed more negative spherical equivalent refraction with wavefront analyzers (OPD-Scan, 0.406 +/- 0.768 D [range: 0.235 to 0.580 D] [P<.001]; WASCA, 0.511 +/- 0.550 D [range: 0.390 to 0.634 D] [P<.001]; and Allegretto, 0.434 +/- 0.904 D [range: 0.233 to 0.635 D] [P<.001]). A second analysis eliminating outliers showed the same trend but lower differences: OPD-Scan (n=75), 0.24 +/- 0.41 D (range: 0.15 to 0.34 D) (P<.001); WASCA (n=78), 0.46 +/- 0.47 D (range: 0.36 to 0.57 D) (P<.001); and Allegretto (n=77), 0.30 +/- 0.62 D (range: 0.16 to 0.44 D) (P<.001). No statistically significant differences were noted for J0 and J45. CONCLUSIONS: Wavefront analyzer refraction resulted in 0.30 D more myopia compared to SRW-5000 refraction in eyes without cycloplegia. This is the result of the accommodation excess attributable to instrument myopia. For the relatively low degrees of astigmatism in this study (<2.0 D), good agreement was noted between wavefront analyzers and the SRW-5000. Copyright (C) 2006 SLACK Incorporated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To evaluate theoretically three previously published formulae that use intra-operative aphakic refractive error to calculate intraocular lens (IOL) power, not necessitating pre-operative biometry. The formulae are as follows: IOL power (D) = Aphakic refraction x 2.01 [Ianchulev et al., J. Cataract Refract. Surg.31 (2005) 1530]; IOL power (D) = Aphakic refraction x 1.75 [Mackool et al., J. Cataract Refract. Surg.32 (2006) 435]; IOL power (D) = 0.07x(2) + 1.27x + 1.22, where x = aphakic refraction [Leccisotti, Graefes Arch. Clin. Exp. Ophthalmol.246 (2008) 729]. METHODS: Gaussian first order calculations were used to determine the relationship between intra-operative aphakic refractive error and the IOL power required for emmetropia in a series of schematic eyes incorporating varying corneal powers, pre-operative crystalline lens powers, axial lengths and post-operative IOL positions. The three previously published formulae, based on empirical data, were then compared in terms of IOL power errors that arose in the same schematic eye variants. RESULTS: An inverse relationship exists between theoretical ratio and axial length. Corneal power and initial lens power have little effect on calculated ratios, whilst final IOL position has a significant impact. None of the three empirically derived formulae are universally accurate but each is able to predict IOL power precisely in certain theoretical scenarios. The formulae derived by Ianchulev et al. and Leccisotti are most accurate for posterior IOL positions, whereas the Mackool et al. formula is most reliable when the IOL is located more anteriorly. CONCLUSION: Final IOL position was found to be the chief determinant of IOL power errors. Although the A-constants of IOLs are known and may be accurate, a variety of factors can still influence the final IOL position and lead to undesirable refractive errors. Optimum results using these novel formulae would be achieved in myopic eyes.