942 resultados para Quality analysis
Resumo:
Metrics estimate the quality of different aspects of software. In particular, cohesion indicates how well the parts of a system hold together. A metric to evaluate class cohesion is important in object-oriented programming because it gives an indication of a good design of classes. There are several proposals of metrics for class cohesion but they have several problems (for instance, low discrimination). In this paper, a new metric to evaluate class cohesion is proposed, called SCOM, which has several relevant features. It has an intuitive and analytical formulation, what is necessary to apply it to large-size software systems. It is normalized to produce values in the range [0..1], thus yielding meaningful values. It is also more sensitive than those previously reported in the literature. The attributes and methods used to evaluate SCOM are unambiguously stated. SCOM has an analytical threshold, which is a very useful but rare feature in software metrics. We assess the metric with several sample cases, showing that it gives more sensitive values than other well know cohesion metrics.
Resumo:
The contamination of aquatic environments is a phenomenon that dates back the origins of human civilizations and was amplified by the advent of industrial processes. The Jundiaí river , Macaíba's main water source, suffering discharge of effluents from various industries. The study work´s in two fronts, the environmental perception front was conducted through semistructured interviews whose textile effluent was appointed by the population as the main problem in the river. It was observed that nearly all respondents had concerns about the environment. In addition, there is an inclusion of individuals as the cause of the problem, because a significant part recognizes that its activities may cause damage to the environment and people's health. In other front, the experimental monitoring of water quality was conducted through ecotoxicological tests and physiochemical analysis that proposed to assess Pomacea lineata .Mysidopsis juniae isolated effect of textile effluent and its influence on the river compared with the limits established by Brazilian law. Although the physio-chemical analysis shows is inconclusive about the participation of the textile effluent in environmental contamination of the river, the ecotoxicological tests have shown to blunt the signal that the effluent may present a risk to aquatic organisms and consequently to human health. Thus, an interdisciplinary way it was possible to study the cause of the environmental problem identified by the population in the realization phase and measurable effect on water quality analysis in the river by means of the tests mentioned.
Resumo:
This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.
Resumo:
Na fabricação de componentes mecânicos precisos, que necessitam de alta resistência mecânica e ao desgaste, utiliza-se o processo de retificação, para conferir o acabamento final desejado e, também, para eliminar as deformações ocorridas durante a têmpera do aço. No entanto, as condições de retificação devem ser adequadas, para que não sejam introduzidas falhas na peça. Novos conceitos de lubrificação e refrigeração, para o processo de retificação, estão sendo pesquisados, de forma a diminuir os custos e os danos ambientais causados pelos fluidos de corte. Nesse trabalho, é analisada a influência das técnicas de mínima quantidade de lubrificante (MQL), refrigeração otimizada e refrigeração convencional, com diferentes vazões e velocidade de aplicação do fluido de corte, na qualidade das peças produzidas com aço ABNT 4340 endurecido, no processo de retificação cilíndrica externa de mergulho com a utilização de rebolos de CBN. O Aço ABNT 4340 apresenta várias aplicações industriais, sendo considerado de uso aeronáutico devido, sua alta resistência mecânica sem aumentar o peso dos componentes que o utilizam. A análise da qualidade das peças foi realizada com a verficação das rugosidades e com a análise de microscopias eletrônicas de varredura. Verificou-se, ainda, a força tangencial de corte. em relação às diferentes formas de aplicação do fluido de corte, notou-se o melhor desempenho da aplicação otimizada, para maiores velocidades, mostrando a eficiência do bocal utilizado. O processo otimizado e o processo MQL foram capazes de manter a integridade superficial das peças produzidas. Exceção somente para a condição MQL com vazão de fluido de corte de 40ml/h, que produziu trincas e queima superficial. Rebolos com baixa concentração de CBN, conseqüentemente mais baratos, proporcionaram bons resultados, quando associados com técnicas mais eficientes de aplicação de fluido de corte apresentando desgaste reduzido.
Resumo:
Los trastornos del comportamiento alimentario (TCA) son las patologías psicológicas que más se han incrementado en los últimos años. Uno de los factores que determina la elevada prevalencia de TCA en nuestra sociedad es el gran desconocimiento sobre alimentación. Este desconocimiento puede deberse a la consulta de recursos online sin validez científica. El objetivo de este trabajo ha sido analizar la calidad científica y el posicionamiento de los sitios web en español con información sobre nutrición, TCA y obesidad. Material y métodos: Se realizó una búsqueda de páginas web en el navegador Google Chrome con las palabras clave: dieta, anorexia, bulimia, nutrición y obesidad, seleccionándose los 20 primeros resultados de cada búsqueda según los índices de posicionamiento ofrecidos por SEOquake (Page Rank, Alexa Rank y SEMrush Rank). Las variables de análisis fueron: información relacionada con dietas y hábitos alimentarios, información sobre alimentación saludable, información sobre TCA y sus criterios diagnósticos e información de carácter formativo acerca de temas profesionales de salud general. Sólo el 50% de las web encontradas cumplían los criterios de inclusión en el estudio. La mayoría no seguían las pautas establecidas por e-Europa sobre calidad. La mediana de Page Rank fue de 2, excepto en aquellas asociadas a instituciones sanitarias de prestigio. Dada la escasez de webs sanitarias con rigor científico, es imprescindible la revisión de las existentes y la creación de nuevos espacios on-line cuya supervisión sea realizada por profesionales especialistas en salud y nutrición.
Resumo:
The wide use of glyphosate-based herbicides (GBHs) has become a controversial issue due to the potential harmful effects on human health. Commercial formulations, among which Roundup is the most famous one, contain a number of adjuvants inside; most of these are patented and not publicly known, therefore, they can act differently from glyphosate alone and might strengthen its toxic effect. Our study is focused on GBHs reproductive toxicity with a special regard to glyphosate and Roundup impact on male and female mammalian gametes after exposure to concentrations ranging from the one recommended for agricultural use (0.1% Roundup, containing 360 µg/mL glyphosate) to 70-fold lower or more. Sperm quality analysis, either on boar and stallion, showed that Roundup has much more detrimental impact than glyphosate at equivalent concentrations on spermatozoa function and survival. Basing on our results, the toxic effect of these pesticides on spermatozoa may be linked to an impairment in mitochondrial activity and a subsequent decrease in ATP production and/or alterations in the redox balance, which impact cell motility and plasma membrane stability. Moreover, a different species sensitivity to GBHs may exists as high doses of glyphosate affected sperm quality only in boar and not in stallion; furthermore, Roundup had deleterious effects at lower doses in the first compared to the latter. With regard to female gametes, we found that glyphosate and Roundup exposure during IVM detrimentally affect the subsequent developmental ability of swine embryos, providing further evidence of their potential toxic effect on female reproductive system. In addition, Roundup altered steroidogenesis and increased oocyte ROS levels. Therefore, according to our results, we can conclude that GBHs exert a negative impact on both male and female gametes and that Roundup adjuvants enhance glyphosate toxic effects and/or are biologically active in their side-effect.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).
Resumo:
A method was optimized for the analysis of omeprazole (OMZ) by ultra-high speed LC with diode array detection using a monolithic Chromolith Fast Gradient RP 18 endcapped column (50 x 2.0 mm id). The analyses were performed at 30 degrees C using a mobile phase consisting of 0.15% (v/v) trifluoroacetic acid (TFA) in water (solvent A) and 0.15% (v/v) TFA in acetonitrile (solvent B) under a linear gradient of 5 to 90% B in 1 min at a flow rate of 1.0 mL/min and detection at 220 nm. Under these conditions, OMZ retention time was approximately 0.74 min. Validation parameters, such as selectivity, linearity, precision, accuracy, and robustness, showed results within the acceptable criteria. The method developed was successfully applied to OMZ enteric-coated pellets, showing that this assay can be used in the pharmaceutical industry for routine QC analysis. Moreover, the analytical conditions established allow for the simultaneous analysis of OMZ metabolites, 5-hydroxyomeprazole and omeprazole sulfone, in the same run, showing that this method can be extended to other matrixes with adequate procedures for sample preparation.
Resumo:
Introduction: mild head trauma (MHT) is defined as a transient neurological deficit after trauma with a history of impairment or loss of consciousness lasting less than 15 min and/or posttraumatic amnesia, and a Glasgow Coma Scale between 13 and 15 on hospital admission. We evaluated 50 MHT patients 18 months after the trauma, addressing signs and symptoms of post-concussion syndrome, quality of life and the presence of anxiety and depression. We correlate those findings with the S100B protein levels and cranial CT scan performed at hospital admission after the trauma. Method: patients were asked to fill out questionnaires to assess quality of life (SF36), anxiety and depression (HADS), and signs and symptoms of post-concussion syndrome. For the control group, we asked the patient`s household members, who had no history of head trauma of any type, to answer the same questionnaires for comparison. Results: total quality of life index for patients with MHT was 58.16 (+/-5), lower than the 73.47 (+/-4) presented by the control group. Twenty patients (55.2%) and four (11.1%) controls were depressed. Seventeen patients (47.2%) presented anxiety, whereas only eight (22.2%) controls were considered anxious. Victims of MHT complained more frequently of loss of balance, dry mouth, pain in the arms, loss of memory and dizziness than their respective controls (p < 0.05). We found no correlation between the presence of these signs and symptoms, quality of life, presence of anxiety and depression with S100B protein levels or with presence of injury in the cranial CT performed at hospital admission. Conclusion: MHT is associated with a higher incidence of post-concussion syndrome symptoms, lower quality of life and anxiety than their respective controls even 18 months after the trauma. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Objective. Refractory, disabling pain associated with knee osteoarthritis (OA) is usually treated with total knee replacement. However, pain in these patients might be associated with central nervous sensitization rather than peripheral inflammation and injury. We evaluated the presence of hyperalgesia in patients scheduled for a total knee replacement due to knee osteoarthritis with refractory pain, and we assessed the impact of pressure pain threshold measurements (PPT) on pain, disability, and quality of life of these patients. Methods. Sixty-two female patients were compared with 22 age-matched healthy controls without reported pain for the last year. PPT was measured at the lower extremities subcutaneous dermatomes, over the vastus medialis, adductor longus, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, iliacus, quadratus lumborum and popliteus muscles and at the supraspinous ligaments from L1-L5, over the L5-S1 and S1-S2 sacral areas and at the pes anserinus bursae and patellar tendon. Results. Patients with knee OA had significantly lower PPT over all evaluated structures versus healthy control subjects (P < 0.001). Lower PPT values were correlated with higher pain intensity, higher disability scores, and with poorer quality of life, except for the role-emotional and general health status. Combined PPT values over the patellar tendon, at the S2 subcutaneous dermatome and at the adductor longus muscle were the best predictors for visual analog scale and Western Ontario and McMaster Universities Osteoarthritis Index pain scores. Conclusion. Patients with pain due to osteoarthritis who were scheduled for total knee replacement showed hyperalgesia of nervous system origin that negatively impacted pain, knee functional capacity, and most aspects of quality of life.
Resumo:
This paper aims to highlight the role of translation quality assessment in translation training so as to develop students’ translation competence and skills to face translation problems. An analysis to assess literary translation quality is proposed before proceeding to discuss its pedagogical implementation.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Intensity Modulated Radiotherapy (IMRT) is a technique introduced to shape more precisely the dose distributions to the tumour, providing a higher dose escalation in the volume to irradiate and simultaneously decreasing the dose in the organs at risk which consequently reduces the treatment toxicity. This technique is widely used in prostate and head and neck (H&N) tumours. Given the complexity and the use of high doses in this technique it’s necessary to ensure as a safe and secure administration of the treatment, through the use of quality control programmes for IMRT. The purpose of this study was to evaluate statistically the quality control measurements that are made for the IMRT plans in prostate and H&N patients, before the beginning of the treatment, analysing their variations, the percentage of rejected and repeated measurements, the average, standard deviations and the proportion relations.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.