675 resultados para Pythagoras cup


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the present study was to examine the suitability of a short pre-stimulation (P) for 15 s followed by a latency period (L) of 30 s before cluster attachment for machine milking. In addition we tested the effect of a periodic reduction of the vacuum under the teat (VR) during the massage phase from 43 kPa to 12-15 kPa on milking characteristics and teat tissue condition. The study was carried out in 9 cows in a cross-over design. Animals were milked twice daily, and each of the 4 treatment combinations was used for six subsequent milkings (P+L vs. continuous P, and standard pulsation vs. VR, respectively). Milk flow was recorded during all experimental milkings. Longitudinal ultrasound cross sections of the teat were performed by B-mode ultrasound after the last milking of each treatment at 0, 5, and 15 min after the end of milking, respectively. None of the evaluated milking characteristics (total milk yield, main milking time, peak flow rate, average milk flow) differed between treatments. Teat measures as obtained by ultrasound cross sections showed no significant difference if individual treatments were compared at the three time points individually. However, teat wall thickness (TWT) tended to be smaller in VR vs. non-VR treatments at 5 min after milking (P=0·05). In conclusion, teat preparation consisting of a short stimulation followed by a latency period represents a similarly efficient pre-stimulation as a continuous pre-stimulation. VR seems to reduce the load on the teat tissue during milking and thus reduces the development of oedema and hence a less pronounced increase of TWT while milking characteristics are similar with or without VR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Malposition of the acetabular component in total hip arthroplasty (THA) is a common surgical problem that can lead to hip dislocation, reduced range of motion and may result in early loosening. The aim of this study is to validate the accuracy and reproducibility of a single x-ray image based 2D/3D reconstruction technique in determining cup inclination and anteversion against two different computer tomography (CT)-based measurement techniques. Methods Cup anteversion and inclination of 20 patients after cementless primary THA was measured on standard anteroposterior (AP) radiographs with the help of the single x-ray 2D/3D reconstruction program and compared with two different 3D CT-based analyses [Ground Truth (GT) and MeVis (MV) reconstruction model]. Results The measurements from the single x-ray 2D/3D reconstruction technique were strongly correlated with both types of CT image-processing protocols for both cup inclination [R²=0.69 (GT); R²=0.59 (MV)] and anteversion [R²=0.89 (GT); R²=0.80 (MV)]. Conclusions The single x-ray image based 2D/3D reconstruction technique is a feasible method to assess cup position on postoperative x-rays. CTscans remain the golden standard for a more complex biomechanical evaluation when a lower tolerance limit (+/-2 degrees) is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GOAL: In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. METHODS: Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. RESULTS: The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. CONCLUSION: While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). SIGNIFICANCE: The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To systematically search the literature and assess the available evidence for the influence of chin-cup therapy on the temporomandibular joint regarding morphological adaptations and appearance of temporomandibular disorders (TMD). MATERIALS AND METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), the Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS From the 209 articles identified, 55 papers were considered eligible for inclusion in the review. Following the full text reading stage, 12 studies qualified for the final review analysis. No randomized clinical trial was identified. Eight of the included studies were of prospective and four of retrospective design. All studies were assessed for their quality and graded eventually from low to medium level of evidence. Based on the reported evidence, chin-cup therapy affects the condylar growth pattern, even though two studies reported no significance changes in disc position and arthrosis configuration. Concerning the incidence of TMD, it can be concluded from the available evidence that chin-cup therapy constitutes no risk factor for TMD. CONCLUSION Based on the available evidence, chin-cup therapy for Class III orthodontic anomaly seems to induce craniofacial adaptations. Nevertheless, there are insufficient or low-quality data in the orthodontic literature to allow the formulation of clear statements regarding the influence of chin-cup treatment on the temporomandibular joint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of anemometer rotor shape parameters, such as the cups’ front area or their center rotation radius on the anemometer’s performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results were compared to the ones resulting from classical analytical models. The results clearly showed a linear dependency of both calibration constants, the slope and the offset, on the cups’ center rotation radius, the influence of the front area of the cups also being observed. The analytical model of Kondo et al. was proved to be accurate if it is based on precise data related to the aerodynamic behavior of a rotor’s cup.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deviation of calibration coefficients from five cup anemometer models over time was analyzed. The analysis was based on a series of laboratory calibrations between January 2001 and August 2010. The analysis was performed on two different groups of anemometers: (1) anemometers not used for any industrial purpose (that is, just stored); and (2) anemometers used in different industrial applications (mainly in the field—or outside—applications like wind farms). Results indicate a loss of performance of the studied anemometers over time. In the case of the unused anemometers the degradation shows a clear pattern. In the case of the anemometers used in the field, the data analyzed also suggest a loss of performance, yet the degradation does not show a clear trend. A recalibration schedule is proposed based on the observed performances variations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of air density variations on the calibration constants of several models of anemometers has been analyzed. The analysis was based on a series of calibrations between March 2003 and February 2011. Results indicate a linear behavior of both calibration constants with the air density. The effect of changes in air density on the measured wind speed by an anemometer was also studied. The results suggest that there can be an important deviation of the measured wind speed with changes in air density from the one at which the anemometer was calibrated, and therefore the need to take this effect into account when calculating wind power estimations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of cup anemometer shape parameters, such as the cups’ shape, their size, and their center rotation radius, was experimentally analyzed.This analysis was based on both the calibration constants of the transfer function and the most important harmonic termof the rotor’smovement,which due to the cup anemometer design is the third one.This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer’s rotor and the mentioned third harmonic term of its movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied.The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction.Thecomparison with the experimental data indicates a nonuniformdistribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance.