Cup Anemometer's loss of performance due to ageing process, and its effect on Annual energy Production (AEP) estimates


Autoria(s): Pindado Carrion, Santiago; Barrero Gil, Antonio; Sanz Lobera, Alfredo
Data(s)

01/05/2012

Resumo

The deviation of calibration coefficients from five cup anemometer models over time was analyzed. The analysis was based on a series of laboratory calibrations between January 2001 and August 2010. The analysis was performed on two different groups of anemometers: (1) anemometers not used for any industrial purpose (that is, just stored); and (2) anemometers used in different industrial applications (mainly in the field—or outside—applications like wind farms). Results indicate a loss of performance of the studied anemometers over time. In the case of the unused anemometers the degradation shows a clear pattern. In the case of the anemometers used in the field, the data analyzed also suggest a loss of performance, yet the degradation does not show a clear trend. A recalibration schedule is proposed based on the observed performances variations

Formato

application/pdf

Identificador

http://oa.upm.es/16021/

Idioma(s)

eng

Publicador

E.U.I.T. Aeronáuticos (UPM)

Relação

http://oa.upm.es/16021/1/INVE_MEM_2012_132114.pdf

http://www.mdpi.com/1996-1073/5/5/1664

info:eu-repo/semantics/altIdentifier/doi/10.3390/en5051664

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

Energies, ISSN 1996-1073, 2012-05, Vol. 5, No. 5

Palavras-Chave #Aeronáutica
Tipo

info:eu-repo/semantics/article

Artículo

PeerReviewed