889 resultados para Prescribed fire
Resumo:
Recently an innovative composite panel system was developed, where a thin insulation layer was used externally between two plasterboards to improve the fire performance of light gauge cold-formed steel frame walls. In this research, finite-element thermal models of both the traditional light gauge cold-formed steel frame wall panels with cavity insulation and the new light gauge cold-formed steel frame composite wall panels were developed to simulate their thermal behaviour under standard and realistic fire conditions. Suitable apparent thermal properties of gypsum plasterboard, insulation materials and steel were proposed and used. The developed models were then validated by comparing their results with available fire test results. This article presents the details of the developed finite-element models of small-scale non-load-bearing light gauge cold-formed steel frame wall panels and the results of the thermal analysis. It has been shown that accurate finite-element models can be used to simulate the thermal behaviour of small-scale light gauge cold-formed steel frame walls with varying configurations of insulations and plasterboards. The numerical results show that the use of cavity insulation was detrimental to the fire rating of light gauge cold-formed steel frame walls, while the use of external insulation offered superior thermal protection to them. The effects of real fire conditions are also presented.
Resumo:
In recent times, light gauge steel framed (LSF) structures, such as cold-formed steel wall systems, are increasingly used, but without a full understanding of their fire performance. Traditionally the fire resistance rating of these load-bearing LSF wall systems is based on approximate prescriptive methods developed based on limited fire tests. Very often they are limited to standard wall configurations used by the industry. Increased fire rating is provided simply by adding more plasterboards to these walls. This is not an acceptable situation as it not only inhibits innovation and structural and cost efficiencies but also casts doubt over the fire safety of these wall systems. Hence a detailed fire research study into the performance of LSF wall systems was undertaken using full scale fire tests and extensive numerical studies. A new composite wall panel developed at QUT was also considered in this study, where the insulation was used externally between the plasterboards on both sides of the steel wall frame instead of locating it in the cavity. Three full scale fire tests of LSF wall systems built using the new composite panel system were undertaken at a higher load ratio using a gas furnace designed to deliver heat in accordance with the standard time temperature curve in AS 1530.4 (SA, 2005). Fire tests included the measurements of load-deformation characteristics of LSF walls until failure as well as associated time-temperature measurements across the thickness and along the length of all the specimens. Tests of LSF walls under axial compression load have shown the improvement to their fire performance and fire resistance rating when the new composite panel was used. Hence this research recommends the use of the new composite panel system for cold-formed LSF walls. The numerical study was undertaken using a finite element program ABAQUS. The finite element analyses were conducted under both steady state and transient state conditions using the measured hot and cold flange temperature distributions from the fire tests. The elevated temperature reduction factors for mechanical properties were based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). These finite element models were first validated by comparing their results with experimental test results from this study and Kolarkar (2010). The developed finite element models were able to predict the failure times within 5 minutes. The validated model was then used in a detailed numerical study into the strength of cold-formed thin-walled steel channels used in both the conventional and the new composite panel systems to increase the understanding of their behaviour under nonuniform elevated temperature conditions and to develop fire design rules. The measured time-temperature distributions obtained from the fire tests were used. Since the fire tests showed that the plasterboards provided sufficient lateral restraint until the failure of LSF wall panels, this assumption was also used in the analyses and was further validated by comparison with experimental results. Hence in this study of LSF wall studs, only the flexural buckling about the major axis and local buckling were considered. A new fire design method was proposed using AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated. A spread sheet based design tool was developed based on the above design codes to predict the failure load ratio versus time and temperature for varying LSF wall configurations including insulations. Idealised time-temperature profiles were developed based on the measured temperature values of the studs. This was used in a detailed numerical study to fully understand the structural behaviour of LSF wall panels. Appropriate equations were proposed to find the critical temperatures for different composite panels, varying in steel thickness, steel grade and screw spacing for any load ratio. Hence useful and simple design rules were proposed based on the current cold-formed steel structures and fire design standards, and their accuracy and advantages were discussed. The results were also used to validate the fire design rules developed based on AS/NZS 4600 (SA, 2005) and Eurocode Part 1.3 (ECS, 2006). This demonstrated the significant improvements to the design method when compared to the currently used prescriptive design methods for LSF wall systems under fire conditions. In summary, this research has developed comprehensive experimental and numerical thermal and structural performance data for both the conventional and the proposed new load bearing LSF wall systems under standard fire conditions. Finite element models were developed to predict the failure times of LSF walls accurately. Idealized hot flange temperature profiles were developed for non-insulated, cavity and externally insulated load bearing wall systems. Suitable fire design rules and spread sheet based design tools were developed based on the existing standards to predict the ultimate failure load, failure times and failure temperatures of LSF wall studs. Simplified equations were proposed to find the critical temperatures for varying wall panel configurations and load ratios. The results from this research are useful to both structural and fire engineers and researchers. Most importantly, this research has significantly improved the knowledge and understanding of cold-formed LSF loadbearing walls under standard fire conditions.
Resumo:
In the last 10 years, the third sector has seen an eruption of texts, websites, discussion forums, conferences, new journals, new research centres and sector-specific degrees. This growing abundance of information allows for hitherto impossible networking, collaboration and general awareness of what is happening in the sector. At the same time, however, like staff in many industries, nonprofit professionals can suffer from an increasingly common 21st century malaise known as ‘information anxiety’. It is worth examining the sector through the lens of Information Studies theory, to question what the information technology needs of nonprofits are and how their information management techniques may differ from those in the public and private sectors. There are implications of this both for those within the industry (in terms of governance, training and public relations) and those external to it (who may form relationships with nonprofits on the basis of access to information).
Resumo:
In redefining our understanding of women’s roles in contemporary Australian philanthropy, the impact of major contextual and demographic changes, as well as changes in women’s roles, responsibilities and opportunities need to be considered. Although academic study of philanthropy and the wider third sector is increasing in Australia, literature searches have revealed little current data on the giving patterns and philanthropic drivers for contemporary Australian women, particularly emerging cohorts (one ABS survey looks at giving patterns – ABS, 2000b: 32). In contrast, there is increasing interest in the US, where it is acknowledged that more women are becoming independent holders of wealth; and that interested donors have specific needs, desires and motivations in terms of knowledge, power, marketing and response to their philanthropy (see for example, Grace 2000; McCarthy 2001; Women’s Philanthropy Institute 2002). These varied demographic, social and economic drivers, which could also be expected to encourage new cohorts of Australian women to give, will be examined within our definition of women in philanthropy, and a brief history of women’s philanthropy in Australia, in order to inform future in-depth analyses of Australian women donors.
Resumo:
Driving and using prescription medicines that have the potential to impair driving is an emerging research area. To date it is characterised by a limited (although growing) number of studies and methodological complexities that make generalisations about impairment due to medications difficult. Consistent evidence has been found for the impairing effects of hypnotics, sedative antidepressants and antihistamines, and narcotic analgesics, although it has been estimated that as many as nine medication classes have the potential to impair driving (Alvarez & del Rio, 2000; Walsh, de Gier, Christopherson, & Verstraete, 2004). There is also evidence for increased negative effects related to concomitant use of other medications and alcohol (Movig et al., 2004; Pringle, Ahern, Heller, Gold, & Brown, 2005). Statistics on the high levels of Australian prescription medication use suggest that consumer awareness of driving impairment due to medicines should be examined. One web-based study has found a low level of awareness, knowledge and risk perceptions among Australian drivers about the impairing effects of various medications on driving (Mallick, Johnston, Goren, & Kennedy, 2007). The lack of awareness and knowledge brings into question the effectiveness of the existing countermeasures. In Australia these consist of the use of ancillary warning labels administered under mandatory regulation and professional guidelines, advice to patients, and the use of Consumer Medicines Information (CMI) with medications that are known to cause impairment. The responsibility for the use of the warnings and related counsel to patients primarily lies with the pharmacist when dispensing relevant medication. A review by the Therapeutic Goods Administration (TGA) noted that in practice, advice to patients may not occur and that CMI is not always available (TGA, 2002). Researchers have also found that patients' recall of verbal counsel is very low (Houts, Bachrach, Witmer, Tringali, Bucher, & Localio, 1998). With healthcare observed as increasingly being provided in outpatient conditions (Davis et al., 2006; Vingilis & MacDonald, 2000), establishing the effectiveness of the warning labels as a countermeasure is especially important. There have been recent international developments in medication categorisation systems and associated medication warning labels. In 2005, France implemented a four-tier medication categorisation and warning system to improve patients' and health professionals' awareness and knowledge of related road safety issues (AFSSAPS, 2005). This warning system uses a pictogram and indicates the level of potential impairment in relation to driving performance through the use of colour and advice on the recommended behaviour to adopt towards driving. The comparable Australian system does not indicate the severity level of potential effects, and does not provide specific guidelines on the attitude or actions that the individual should adopt towards driving. It is reliant upon the patient to be vigilant in self-monitoring effects, to understand the potential ways in which they may be affected and how serious these effects may be, and to adopt the appropriate protective actions. This thesis investigates the responses of a sample of Australian hospital outpatients who receive appropriate labelling and counselling advice about potential driving impairment due to prescribed medicines. It aims to provide baseline data on the understanding and use of relevant medications by a Queensland public hospital outpatient sample recruited through the hospital pharmacy. It includes an exploration and comparison of the effect of the Australian and French medication warning systems on medication user knowledge, attitudes, beliefs and behaviour, and explores whether there are areas in which the Australian system may be improved by including any beneficial elements of the French system. A total of 358 outpatients were surveyed, and a follow-up telephone survey was conducted with a subgroup of consenting participants who were taking at least one medication that required an ancillary warning label about driving impairment. A complementary study of 75 French hospital outpatients was also conducted to further investigate the performance of the warnings. Not surprisingly, medication use among the Australian outpatient sample was high. The ancillary warning labels required to appear on medications that can impair driving were prevalent. A subgroup of participants was identified as being potentially at-risk of driving impaired, based on their reported recent use of medications requiring an ancillary warning label and level of driving activity. The sample reported previous behaviour and held future intentions that were consistent with warning label advice and health protective action. Participants did not express a particular need for being advised by a health professional regarding fitness to drive in relation to their medication. However, it was also apparent from the analysis that the participants would be significantly more likely to follow advice from a doctor than a pharmacist. High levels of knowledge in terms of general principles about effects of alcohol, illicit drugs and combinations of substances, and related health and crash risks were revealed. This may reflect a sample specific effect. Emphasis is placed in the professional guidelines for hospital pharmacists that make it essential that advisory labels are applied to medicines where applicable and that warning advice is given to all patients on medication which may affect driving (SHPA, 2006, p. 221). The research program applied selected theoretical constructs from Schwarzer's (1992) Health Action Process Approach, which has extended constructs from existing health theories such as the Theory of Planned Behavior (Ajzen, 1991) to better account for the intention-behaviour gap often observed when predicting behaviour. This was undertaken to explore the utility of the constructs in understanding and predicting compliance intentions and behaviour with the mandatory medication warning about driving impairment. This investigation revealed that the theoretical constructs related to intention and planning to avoid driving if an effect from the medication was noticed were useful. Not all the theoretical model constructs that had been demonstrated to be significant predictors in previous research on different health behaviours were significant in the present analyses. Positive outcome expectancies from avoiding driving were found to be important influences on forming the intention to avoid driving if an effect due to medication was noticed. In turn, intention was found to be a significant predictor of planning. Other selected theoretical constructs failed to predict compliance with the Australian warning label advice. It is possible that the limited predictive power of a number of constructs including risk perceptions is due to the small sample size obtained at follow up on which the evaluation is based. Alternately, it is possible that the theoretical constructs failed to sufficiently account for issues of particular relevance to the driving situation. The responses of the Australian hospital outpatient sample towards the Australian and French medication warning labels, which differed according to visual characteristics and warning message, were examined. In addition, a complementary study with a sample of French hospital outpatients was undertaken in order to allow general comparisons concerning the performance of the warnings. While a large amount of research exists concerning warning effectiveness, there is little research that has specifically investigated medication warnings relating to driving impairment. General established principles concerning factors that have been demonstrated to enhance warning noticeability and behavioural compliance have been extrapolated and investigated in the present study. The extent to which there is a need for education and improved health messages on this issue was a core issue of investigation in this thesis. Among the Australian sample, the size of the warning label and text, and red colour were the most visually important characteristics. The pictogram used in the French labels was also rated highly, and was salient for a large proportion of the sample. According to the study of French hospital outpatients, the pictogram was perceived to be the most important visual characteristic. Overall, the findings suggest that the Australian approach of using a combination of visual characteristics was important for the majority of the sample but that the use of a pictogram could enhance effects. A high rate of warning recall was found overall and a further important finding was that higher warning label recall was associated with increased number of medication classes taken. These results suggest that increased vigilance and care are associated with the number of medications taken and the associated repetition of the warning message. Significantly higher levels of risk perception were found for the French Level 3 (highest severity) label compared with the comparable mandatory Australian ancillary Label 1 warning. Participants' intentions related to the warning labels indicated that they would be more cautious while taking potentially impairing medication displaying the French Level 3 label compared with the Australian Label 1. These are potentially important findings for the Australian context regarding the current driving impairment warnings about displayed on medication. The findings raise other important implications for the Australian labelling context. An underlying factor may be the differences in the wording of the warning messages that appear on the Australian and French labels. The French label explicitly states "do not drive" while the Australian label states "if affected, do not drive", and the difference in responses may reflect that less severity is perceived where the situation involves the consumer's self-assessment of their impairment. The differences in the assignment of responsibility by the Australian (the consumer assesses and decides) and French (the doctor assesses and decides) approaches for the decision to drive while taking medication raises the core question of who is most able to assess driving impairment due to medication: the consumer, or the health professional? There are pros and cons related to knowledge, expertise and practicalities with either option. However, if the safety of the consumer is the primary aim, then the trend towards stronger risk perceptions and more consistent and cautious behavioural intentions in relation to the French label suggests that this approach may be more beneficial for consumer safety. The observations from the follow-up survey, although based on a small sample size and descriptive in nature, revealed that just over half of the sample recalled seeing a warning label about driving impairment on at least one of their medications. The majority of these respondents reported compliance with the warning advice. However, the results indicated variation in responses concerning alcohol intake and modifying the dose of medication or driving habits so that they could continue to drive, which suggests that the warning advice may not be having the desired impact. The findings of this research have implications for current countermeasures in this area. These have included enhancing the role that prescribing doctors have in providing warnings and advice to patients about the impact that their medication can have on driving, increasing consumer perceptions of the authority of pharmacists on this issue, and the reinforcement of the warning message. More broadly, it is suggested that there would be benefit in a wider dissemination of research-based information on increased crash risk and systematic monitoring and publicity about the representation of medications in crashes resulting in injuries and fatalities. Suggestions for future research concern the continued investigation of the effects of medications and interactions with existing medical conditions and other substances on driving skills, effects of variations in warning label design, individual behaviours and characteristics (particularly among those groups who are dependent upon prescription medication) and validation of consumer self-assessment of impairment.
Resumo:
Abstract. Fire safety of light gauge cold-formed steel frame (LSF) stud walls is significant in the design of buildings. In this research, finite element thermal models of both the traditional LSF wall panels with cavity insulation and the new LSF composite wall panels were developed to simulate their thermal behaviour under standard and real design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and literature review. The developed models were then validated by comparing their results with available fire test results. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.
Numerical and experimental studies of cold-formed steel floor systems under standard fire conditions
Resumo:
Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.
Resumo:
Cold-formed steel stud walls are an important component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin-walled steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of these wall systems while past research showed contradicting results about the benefits of cavity insulation. This research proposed a new LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating of walls. Full scale fire tests were conducted using both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. Eleven full scale load bearing wall specimens were tested to study the thermal and structural performances of the load bearing wall assemblies under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls while also providing good explanations and supporting test data to overcome the incorrect industry assumptions about cavity insulation. Tests demonstrated that the use of external insulation in a composite panel form enhanced the thermal and structural performances of stud walls and increased their fire resistance rating significantly. This paper presents the details of the full scale fire tests of load-bearing wall assemblies lined with plasterboards and different types of insulation under varying load ratios. Test results including the temperature and deflection profiles of walls measured during the fire tests will be presented along with their failure modes and failure times.
Resumo:
Fire safety of buildings has been recognised as very important by the building industry and the community at large. Traditionally, increased fire rating is provided by simply adding more plasterboards to light gauge steel frame (LSF) walls, which is inefficient. Many research studies have been undertaken to investigate the thermal behaviour of traditional LSF stud wall systems under standard fire conditions. However, no research has been undertaken on the thermal behaviour of LSF stud walls using the recently proposed composite panel. Extensive fire testing of both non-load bearing and load bearing wall panels was conducted in this research based on the standard time-temperature curve in AS1530.4. Three groups of LSF wall specimens were tested with no insulation, cavity insulation and the new composite panel based on an external insulation layer between plasterboards. This paper presents the details of this experimental study into the thermal performance of non-load bearing walls lined with various configurations of plasterboard and insulation. Extensive descriptive and numerical results of the tested non-load bearing wall panels given in this paper provide a thorough understanding of their thermal behaviour, and valuable time-temperature data that can be used to validate numerical models. Test results showed that the innovative composite stud wall systems outperformed the traditional stud wall systems in terms of their thermal performance, giving a much higher fire rating.
Resumo:
Abstract. Fire resistance has become an important part in structural design due to the ever increasing loss of properties and lives every year. Conventionally the fire rating of load bearing Light gauge Steel Frame (LSF) walls is determined using standard fire tests based on the time-temperature curve given in ISO 834 [1]. Full scale fire testing based on this standard time-temperature curve originated from the application of wood burning furnaces in the early 1900s and it is questionable whether it truly represents the fuel loads in modern buildings. Hence a detailed fire research study into the performance of LSF walls was undertaken using real design fires based on Eurocode parametric curves [2] and Barnett’s ‘BFD’ curves [3]. This paper presents the development of these real fire curves and the results of full scale experimental study into the structural and fire behaviour of load bearing LSF stud wall systems.
Resumo:
Gypsum plasterboards are commonly used as a fire safety material in the building industry. Many research studies have been undertaken to investigate the thermal behaviour of plasterboards under standard fire conditions. However, there are many discrepancies in relation to the basic thermal properties of plasterboards while simple equations are not available to predict the ambient surface time–temperature profiles of gypsum plasterboard panels that can be used in simulating the behaviour and strength of steel studs or joists in load bearing LSF wall and floor systems. In this research, suitable thermal properties of plasterboards were proposed based on a series of tests and available results from past research. Finite element models of gypsum plasterboard panels were then developed to simulate their thermal behaviour under standard fire conditions. The accuracy of the proposed thermal properties and the finite element models was validated by comparing the numerical results with available fire test results of plasterboard panels. This paper presents the details of the finite element models of plasterboard panels, the thermal analysis results from finite element analyses under standard fire conditions and their comparisons with experimental results
Resumo:
Gypsum plasterboards are commonly used to protect the light gauge steel-framed walls in buildings from fires. Single or multiple plasterboards can be used for this purpose, whereas recent research has proposed a composite panel with a layer of external insulation between two plasterboards. However, a good understanding of the thermal behaviour of these plasterboard panels under fire conditions is not known. Therefore, 15 small-scale fire tests were conducted on plasterboard panels made of 13 and 16 mm plasterboards and four different types of insulations with varying thickness and density subject to standard fire conditions in AS 1530.4. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effects of interfaces between adjacent plasterboards. Effects of using external insulations such as glass fibre, rockwool and cellulose fibre were also determined. The thermal performance of composite panels developed from different insulating materials of varying densities and thicknesses was examined and compared. This paper presents the details of the fire tests conducted in this study and their valuable time–temperature data for the tested plasterboard panels. These data can be used for the purpose of developing and validating accurate thermal numerical models of these panels.
Resumo:
For fuel management and/or ecological reasons prescribed burnings are conducted each year across Australia. Smoke from prescribed burnings could be the major source of air pollution in urban environment during the period of intensive prescribed burning. To investigate the impact of prescribed burning on air quality and the characteristics of prescribed burning particles, field measurements were conducted during the end period of a prescribed burning event in September 2011, Brisbane, Australia.
Resumo:
Numerical study is carried out using large eddy simulation to study the heat and toxic gases released from fires in real road tunnels. Due to disasters about tunnel fires in previous decade, it attracts increasing attention of researchers to create safe and reliable ventilation designs. In this research, a real tunnel with 10 MW fire (which approximately equals to the heat output speed of a burning bus) at the middle of tunnel is simulated using FDS (Fire Dynamic Simulator) for different ventilation velocities. Carbone monoxide concentration and temperature vertical profiles are shown for various locations to explore the flow field. It is found that, with the increase of the longitudinal ventilation velocity, the vertical profile gradients of CO concentration and smoke temperature were shown to be both reduced. However, a relatively large longitudinal ventilation velocity leads to a high similarity between the vertical profile of CO volume concentration and that of temperature rise.
Resumo:
In the face of Australia’s disaster-prone environment, architects Ian Weir and James Davidson are reconceptualising how our residential buildings might become more resilient to fire, flood and cyclone. With their first-hand experience of natural disasters, James, director of Emergency Architects Australia (EAA), and Ian, one of Australia’s few ‘bushfire architects’, discuss the ways we can design with disaster in mind. Dr Ian Weir is one of Australia’s few ‘bushfire architects’. Exploring a holistic ‘ground up’ approach to bushfire where landscape, building design and habitation patterns are orchestrated to respond to site-specific fire characteristics. Ian’s research is developed through design studio teaching at QUT and through built works in Western Australia’s fire prone forests and heathlands.