847 resultados para Performance technology


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inulin was used as a prebiotic to improve the quality and consistency of skim milk fermented by co-cultures and pure Cultures of Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus and Bifidobacterium lactis with Streptococcus thermophilus. We compared, either in the presence or absence of 4 g inulin/100 g, the results of the main kinetic parameters, specifically the generation time (t(g)), the maximum acidification rate (V(max)). and the times to reach V(max) (t(max)), to attain pH 5.0 (t(pH5.0)) and to complete the fermentation (t(pH4.5)). Post-acidification, lactic acid formation and cell counts were also determined and compared, either 1 day after the fermentation was complete or after 7 day storage at 4 degrees C. In general, inulin addition to the milk increased in co-cultures V(max), decreased t(max), t(g) and t(pH4.5), favored post-acidification, exerted a bifidogenic effect, and preserved almost intact cell viability during storage. In addition, S. thermophilus was shown to stimulate the metabolism of the other lactic bacteria. Contrary to co-cultures, most of the effects in pure Cultures were not statistically significant. The most important aspect of this paper is the use of the generation time as a toot to investigate the microbial response to inulin addition. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inulin was used as a prebiotic to improve the quality and consistency of skim milk fermented by Lactobacillus acidophilus (La), Lactobacillus rhamnosus (Lr), Lactobacillus bulgaricus (Lb) and Bifidobacterium lactis (BI) with Streptococcus thermophilus (St), either in binary co-cultures or in cocktail containing all microorganisms. We compared, either in the presence of 40 mg inulin g(-1) or not, the results of the maximum acidification rate (V(max)) and the times to reach it (t(max)), to reach pH 5.0 (t(PH5.0)) and to complete the fermentation (t(f)). Post-acidification, lactic acid formation and cell counts were also compared after either 1 day (D1) or 7 days of storage at 4 degrees C (N). In co-culture, inulin addition to the milk increased V(max), decreased t(max) and t(f), favored post-acidification and exerted a bifidogenic effect. S. thermophilus proved to stimulate the metabolism of the other lactic bacteria and enhanced the product features. After D7, a significant prebiotic effect of inulin was observed in all co-cultures. Either after D1 or D7, the enumerations of Lr and BI in mixed culture markedly decreased compared to their respective co-cultures because of greater competition for the same substrates. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Aqueous two-phase micellar systems (ATPMS) are micellar surfactant solutions with physical properties that make them very efficient for the extraction/concentration of biological products. In this work the main proposal that has been discussed is the possible applicability and importance of a novel oscillatory flow micro-reactor (micro-OFR) envisaged for parallel screening and/or development of industrial bioprocesses in ATPMS. Based on the technology of oscillatory flow mixing (OFM), this batch or continuous micro-reactor has been presented as a new small-scale alternative for biological or physical-chemical applications. RESULTS: ATPMS experiments were carried out in different OFM conditions (times, temperatures, oscillation frequencies and amplitudes) for the extraction of glucose-6-phosphate dehydrogenase (G6PD) in Triton X-114/buffer with Cibacron Blue as affinity ligand. CONCLUSION: The results suggest the potential use of OFR, considering this process a promising and new alternative for the purification or pre-concentration of bioproducts. Despite the applied homogenization and extraction conditions have presented no improvements in the partitioning selectivity of the target enzyme, when at rest temperature they have influenced the partitioning behavior in Triton X-114 ATPMS. (C) 2011 Society of Chemical Industry

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brain electrical activity related to working memory was recorded at 15 scalp electrodes during a visuospatial delayed response task. Participants (N = 18) touched the remembered position of a target on a computer screen after either a 1 or 8 sec delay. These memory trials were compared to sensory trials in which the target remained present throughout the delay and response periods. Distracter stimuli identical to the target were briefly presented during the delay on 30% of trials. Responses were less accurate in memory than sensory trials, especially after the long delay. During the delay slow potentials developed that were significantly more negative in memory than sensory trials. The difference between memory and sensory trials was greater at anterior than posterior electrodes. On trials with distracters, the slow potentials generated by memory trials showed further enhancement of negativity whereas there were minimal effects on accuracy of performance. The results provide evidence that engagement of visuospatial working memory generates slow wave negativity with a timing and distribution consistent with frontal activation. Enhanced brain activity associated with working memory is required to maintain performance in the presence of distraction. © 1997 by the Massachusetts Institute of Technology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. Methods: The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). Results: The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa=0.70; kappa p=0.001; McNemar p=1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. Conclusions: the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies. (Clin. Lab. 2010;56:29-35)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

According to the producers, CHROMagar (TM) Listeria medium comes to facilitate the detection, differentiating Listeria monocytogenes from the other species, directly on the isolation process, allowing final results in 72 h, while the traditional method takes up to 10 days. A total of 120 food samples of sliced cooked ham, ground beef and frankfurters was analyzed. From 151 colonies presenting typical L. monocytogenes characteristics on CHROMagar (TM) Listeria (bluish, surrounded by a white halo), only 95 (62.9%) were confirmed as L. monocytogenes. The medium was highly sensitive to detect L. monocytogenes in ground beef and frankfurter, but not in sliced ham. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to compare Petrifilm Aerobic Count (AC) plates and the conventional pour plate methodology using the de Man-Rogosa-Sharpe (MRS) agar for the enumeration of lactic acid bacteria (LAB) in fermented milks (FMs), with different starter cultures added. FM samples (n = 66) were collected and plated on both methodologies, with incubation under anaerobic conditions at 35C for 48 h. The count results were compared by analysis of variance (P <= 0.05) and regression analysis. No differences between the mean counts obtained by both methodologies were observed, even when distinct FMs were compared. Considering all samples, a high correlation level was obtained between Petrifilm AC and MRS agar (r = 0.92), but these indexes were lower in FMs with Streptococcus thermophilus and Lactobacillus delbrueckii subsp. bulgaricus (r = 0.90) and Lactobacillus fortis (r = 0.81). Despite some slight interferences, Petrifilm AC has proven to be a convenient methodology on enumerating LAB in FM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The importance of education and experience to the successful performance of new firms is well recognized both by management practitioners and academics. Yet empirical research to support the significance of this relationship is inconclusive. This paper discusses theories describing the relationship between education and experience and firm performance. It also analyses and classifies the differing measures of performance, education and experience, and compares the results of multiple studies undertaken between 1977 and 2000. Possible reasons for conflicting results are identified, such as lack of sound theoretical bases that relate education and experience to performance, varying definitions of the key variables and the diversity of measures used. Finally, a framework is developed that incorporates variables that interact with experience and education to influence new venture performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-cost UHF-band p-i-n diodes are used to develop high-performance L-band series and parallel switches. To stop the rectification of large RF, signals, the diodes are biased at a large reverse-bias voltage. Parasitic elements of the diodes are tuned out using LC circuits in biasing circuits without increasing the size of the switches. (C) 2002 John Wiley Sons, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the impact characteristics of an ethylene vinyl acetate (EVA) mouthguard material with regulated air inclusions, which included various air cell volumes and wall thickness between air cells. In particular, the aim was to identify the magnitude and direction of forces within the impacts. Method: EVA mouthguard material, A mm thick and with and without air inclusions, was impacted with a constant force impact pendulum with an energy of 4.4 J and a velocity of 3 m/s. Transmitted forces through the EVA material were measured using an accelerometer, which also allowed the determination of force direction and magnitude within the impacts. Results: Statistically significant reductions in the transmitted forces were observed with all the air inclusion materials when compared with EVA without air inclusions. Maximum transmitted force through one air inclusion material was reduced by 32%. Force rebound was eliminated in one material, and reduced second force impulses were observed in all the air inclusion materials. Conclusion: The regulated air inclusions improved the impact characteristics of the EVA mouthguard material, the material most commonly used in mouthguards world wide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improvement of the environmental performance of processes and products is a common objective in industry, and has been receiving increased attention in recent years. The main objective of this work is to evaluate the potential environmental impact of two bedding products, a polyurethane foam mattress (PFM) and a pocket spring mattress (PSM). These two types are the most common mattresses used in Europe. A Life Cycle Assessment (LCA) shows that the PFM has a higher environmental impact than the PSM. For both products the main cause of environmental impact is the manufacturing process, respectively the polyurethane foam block moulding process for the PFM, and the pocket spring nucleus process for the PSM. A scenario analysis shows the possibility of reducing the environmental impact of the products’ life cycle using an alternative End-of-Life scenario, resorting to incineration rather than landfill. Two strategies were also studied in order to reduce the environmental impact of the PFM: (1) reutilization of foam that was sent to the waste system management, and (2) a 20% weight reduction of the polyurethane foam. The second strategy has proven to be the most effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates realism in character computer animation, which triggered the development of new techniques and aesthetic in spectacular cinema and contemporary culture. With the advent of motion or performing capture, animation has made possible that virtual characters or digital creatures reach higher levels in emotional acting, taking place in virtual cinematic worlds or even special effects movies. This technology, when placed at the service of imagination and fantasy can provide new dimensions in character motion and communication. In this context, projects like Peter Jackson’s (2001) The Lord of the Rings, James Cameron’s Avatar (2009) and more recently Steven Spielberg’s Tintin (2011) demonstrate that motion technology is constantly evolving, and it represents a credible option to explore new techniques and aesthetic in contemporary animation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many public organisations have been under great pressure in recent years to increase the efficiency and transparency of outputs, to rationalise the use of public resources, and to increase the quality of service delivery. In this context, public organisations were encouraged to introduce the New Public Management reforms with the goal of improving the efficiency and effectiveness of the performance organisation through a new public management model. This new public management model is based on measurement by outputs and outcomes, a clear definition of responsibilities, the transparency and accountability of governmental activities, and on a greater value for citizens. What type of performance measurement systems are used in police services? Based on the literature, we see that multidimensional models, such as the Balanced Scorecard, are important in many public organisations, like municipalities, universities, and hospitals. Police services are characterised by complex, diverse objectives and stakeholders. Therefore, performance measurement of these public services calls for a specific analysis. Based on a nationwide survey of all police chiefs of the Portuguese police force, we find that employee performance measurement is the main form of measurement. Also, we propose a strategic map for the Portuguese police service.