87 resultados para Peltier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The viral proteins synthesized by a Moloney murine sarcoma virus (Mo-MuSV) with a temperature-sensitive mutation in a function required for the maintenance of the transformed state (ts110) were examined. Normal rat kidney cells (NRK) were infected with the ts110 virus and a non-virus-producing cell clone, termed 6m2, was isolated. This cell clone had a malignant phenotype at 33(DEGREES), the permissive temperature, but changed to a normal phenotype at 39(DEGREES).^ Two viral proteins were detected in 6m2 cells. A 58,000 dalton protein (P58) was detected at both 33(DEGREES) and 39(DEGREES) and contained only core protein (gag) coded sequences. An 85,000 dalton protein (P85) was detected only at 33(DEGREES) and contained sequences of viral core proteins p15, pp12, and part of p30 as well as protein sequences attributed by peptide mapping to P23 and P38, two candidate viral mouse src (v-mos) gene products. These results provide good evidence that P85 is a gag-mos polyprotein. As expected for a functional mos-gene product, P85 synthesis preceded parameters characteristic of the transformed state, including changes in cell morphology, in the cytoplasmic microtubule complex (CMTC) and in the rate of hexose uptake.^ Other studies were conducted to ascertain the defect which prohibited the synthesis of P85 at 39(DEGREES), the non-permissive temperature. When 6m2 cells were treated with actinomycin D at 39(DEGREES) and shifted to 33(DEGREES), the cells were unable to synthesize P85, but P58 continued to be made. P85 mRNA, active at 33(DEGREES), continued to be translated for two to three hours after shifting to 39(DEGREES) as judged by pulse-labeling experiments. Virus harvested at 33(DEGREES) from ts110 MuSV producer cells packaged both P85 and P58 coding RNAs while virus harvested at 39(DEGREES) was deficient in the amount of P85 coding RNA. Agarose gel electrophoresis of 6m2 cellular RNA showed that RNA harvested at 33(DEGREES) contained the 4.0 and 3.5 kb RNAs. Similar experiments on cells maintained at 39(DEGREES) have detected only the 4.0 kb RNA, suggesting that the 3.5 kb RNA codes for P85. The defect appeared to be in the long term stability of the P85 coding RNA at 39(DEGREES), since, in shift-up experiments (33(DEGREES) (--->) 39(DEGREES)), P85 was translated for only three hours at 39(DEGREES), while P58 was synthesized for at least eight hours. However, at 33(DEGREES) in the presence of actinomycin D, the ratio of P85 and P58 synthesis at hourly intervals was similar throughout a 12 hour period. ^

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the mid-Pleistocene transition the dominant 41 ka periodicity of glacial cycles transitioned to a quasi-100 ka periodicity for reasons not yet known. This study investigates the potential role of deep ocean hydrography by examining oxygen isotope ratios in benthic foraminifera. Oxygen isotope records from the Atlantic, Pacific and Indian Ocean basins are separated into their ice volume and local temperature/hydrography components using a piece-wise linear transfer function and a temperature calibration. Although our method has certain limitations, the deep ocean hydrography reconstructions show that glacial deep ocean temperatures approached freezing point as the mid-Pleistocene transition progressed. Further analysis suggests that water mass reorganisation could have been responsible for these temperature changes, leading to such stable conditions in the deep ocean that some obliquity cycles were skipped until precessional forcing triggered deglaciation, creating the apparent quasi-100 ka pattern. This study supports previous work that suggests multiples of obliquity cycles dominate the quasi-100 ka glacial cycles with precession components driving deglaciations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sistema y dispositivo condensador para la recogida de agua del medio ambiente. El dispositivo condensador (26) comprende: - dos células peltier (1,2); - medios disipadores de calor (4) en contacto con la cara caliente de las células peltier (1,2); - una superficie de condensación (6) en contacto con la cara fría de las células peltier (1,2); - un habitáculo (9) para alojar las células peltier (1,2), delimitando una cámara fría (10) y una cámara caliente (11), con aberturas para la salida del aire (13,15) en ambas cámaras (10,11) y abertura regulable (14) para la entrada de aire en la cámara fría (10); - medios sensores de humedad relativa (17) y de temperatura (16) del aire en el interior de la cámara fría (10); - medios sensores de temperatura (7) de la superficie de condensación (6); - medios de recogida (18,19,20,21) del agua condensada en la superficie de condensación (6).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El enfriamiento tradicional de los LEDs, mediante disipadores térmicos, se ve muchas veces comprometido al tener que disponer estos elementos refrigeradores justo en el punto de generación de la luz. Para evitar, en la medida de lo posible, este hecho, se presenta como una de las posibles alternativas el empleo de los ?Heat Pipes?. Los Heat Pipes son unos dispositivos autónomos, que permiten refrigerar los focos calientes, trasladando el calor generado por ellos a disipadores térmicos situados en zonas más accesibles y menos comprometidas. Los Heat Pipe, basados en técnicas termodinámicas, tienen un uso muy extendido en la tecnología aeroespacial. Son actualmente la solución ideal en aplicaciones de bombeo de calor y refrigeración de componenetes electricos y electrónicos. Con tamaños reducidos, pueden alcanzar flujos de refrigeración de 300 - 400 W/cm2. En esta comunicación se presenta y analiza este tipo de refrigeración aplicada a LED¿s utilizados en iluminación y alumbrado. La refrigeración de LEDs propuesta está compuesta por el Heat Pipe adosado por un extremo a la cara posterior del diodo LED, y por el otro, a una cierta distancia, al disipador térmico. La temperatura alcanzada por el LED dependerá del tipo y características del Heat Pipe así como de las cualidades del disipador térmico utilizado. También se utilizan en combinación con refrigeradores termoeléctricos (células de Peltier) cuando se desea controlar la temperatura de los dispositivos por debajo de la temperatura ambiental.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de este Proyecto Final de Carrera es la realización de un ensayo de fiabilidad de componentes electrónicos, más concretamente de diodos LED, con el fin de estudiar su comportamiento a lo largo del tiempo de vida. Debido a la larga duración de los LEDs, un ensayo de este tipo podría durar años, por lo que es necesario realizar un ensayo acelerado que acorte significativamente el tiempo del experimento, para ello, han de someterse a esfuerzos mayores que en condiciones normales de funcionamiento. En la actualidad, los LEDs son usados en infinidad de aplicaciones, debido a sus múltiples ventajas respecto a otros sistemas de iluminación o señalización convencionales. En numerosos casos se utilizan en el exterior, soportando cambios de temperaturas y de humedad elevados, de ahí, la importancia de realizar ensayos de fiabilidad, que muestren sus posibles causas de fallo, los efectos que producen estos fallos y los aspectos de diseño, fabricación y mantenimiento que puedan afectarles. Como consecuencia del envejecimiento de los LEDs, pueden mostrar una reducción en el flujo luminoso y un empeoramiento de las propiedades cromáticas. Los LEDs utilizados en este Proyecto son de AlInGaP, rojos, de alta luminosidad. Para acelerar el ensayo, se utilizará una cámara climática que simule unas condiciones ambientales determinadas, en concreto, 85º C y 85% HR. Además, se realiza una monitorización periódica, siendo necesaria la utilización de un sistema automático de medida diseñado en LabVIEW, el cual, de manera simultánea realizará medidas y gestionará la inyección de corriente a los LEDs mientras se encuentren en el interior de la cámara climática. Se fabrican dos placas con 4 tiras de LEDs para inyectar un nivel de corriente diferente en cada una y así poder comparar la degradación en función de este parámetro. Fuera de la cámara climática se van a medir las curvas características de tensióncorriente de cada LED a una temperatura ambiente constante, fijada por un módulo Peltier. También se realizarán medidas de potencia luminosa y de espectro de emisión. Se analizarán los resultados obtenidos de cada una de las medidas y se realizará un estudio de fiabilidad y del proceso de degradación sufrido por los LEDs. Este PFC se puede dividir en las siguientes fases de trabajo, siendo el ensayo la parte más larga en el tiempo: · Búsqueda de bibliografía, documentación y normas aplicables. · Familiarización con los equipos y software, estudiando el manejo y funcionamiento de la cámara climática temperatura-humedad y el software a aplicar (LabVIEW y software del espectrómetro). · Desarrollo del hardware y sistemas necesarios para la realización del ensayo. · Realización del ensayo. · Análisis de resultados. ABSTRACT. The objective of this end of degree project is conducting an essay reliability of electronic components, more concretely LEDs, in order to study their behavior throughout its lifespan. Due to the long duration of the LEDs, a essay of this type could last for years, so it is necessary to perform an accelerated essay which significantly shorten the time of the experiment, testing should be subjected to greater efforts than in normal operation. Today, LEDs are used in many applications due to its many advantages over other conventional lighting systems or signaling. In numerous cases are used on the outside, enduring high changes in temperature and humidity, hence the importance of reliability essays, showing the possible causes of failure, the effects produced by these failures and aspects of design, manufacturing and maintenance that may affect them. As a result of the ageing of the LEDs, they may show a reduction in light output and a worsening of the chromatic properties. The LEDs used in this project are AlInGaP, red and high brightness. To speed up the essay will be used a climatic chamber to simulate specific environmental conditions, specifically 85 ° C and 85 % RH. In addition, is pe rformed a periodic monitoring using an automatic measurement system designed in LabVIEW , which , simultaneously will performed measurements and will manage the injection current to the LEDs while are inside of the climatic chamber. 4 strips of LEDs are created to inject a different level of current in each, so can compare the degradation in terms of this parameter. Out of the climatic chamber are obtained the characteristic curves of voltage-current of each LED at a constant room temperature, set by a Peltier module. Also, measures light power and the emitted spectrum. The results of each of the measures and a reliability study and degradation suffered by the LEDs will be discussed. This PFC can be divided into the following steps, the essay being the longest part: • Search bibliography, documentation and standards. • Familiarization with equipment and software, studying the management and the operation of the temperature-humidity environmental chamber and applying software (LabVIEW applications and spectrometer software). • Development of hardware and systems necessary for the conduct of the essay. • Carrying out the essay. • Analysis of results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El proyecto que se va a implementar es el diseño, construcción y puesta en marcha de un instrumento de medida del comportamiento de las lentes de Fresnel a distintas temperaturas. Dicho proyecto se desarrollará en el grupo de Integración de Sistemas e Instrumentos (ISI) del Instituto de Energía Solar. Las lentes de Fresnel se emplean en la tecnología de concentración fotovoltaica (CPV), siendo una parte imprescindible en este campo. La necesidad de este instrumento se justifica ya que al variar la temperatura de estas lentes, estando fabricadas con Silicona Sobre Vidrio (SOG), varía su distancia focal y por ello baja considerablemente la eficiencia de las células de concentración. La parte a implementar físicamente en este proyecto es una cámara térmica en la que se puedan introducir estas lentes primarias con el objetivo de ponerlas a una determinada temperatura. Para poder mantener un rango de temperaturas entre 5ºC y 60ºC se van a utilizar dos módulos peltier. Por lo tanto, es necesario que dicha cámara térmica tenga tanto en la parte frontal como en la trasera, unas ventanas de vidrio de alta transmitancia que permitan el máximo paso de luz, afectando lo menos posible a la medida. El diseño de la cámara térmica incluye unas cámaras en cada pared en las que se introducirá un aislante térmico para minimizar las pérdidas mencionadas anteriormente. Con este objetivo, las ventanas admiten la opción de un doble acristalado, adquiriendo un compromiso entre aislamiento térmico y transmisión de luz. La caja estará formada por tres cámaras, una central en la que se va a colocar la lente que se quiere medir y dos cámaras laterales en las que se van a introducir ambos peltier respectivamente. El objetivo de estas cámaras laterales es que, al estar comunicadas con la central a través de pequeñas rendijas, el aire a una cierta temperatura llegue de la forma más uniforme posible a la lente. En cuanto a la cámara central, tiene varios carriles en los cuales se pondrá la lente que se quiere medir, permitiendo de esta forma medir lentes de distancias focales muy diferentes además de poder fijar con la menor incertidumbre posible la posición de dicha lente. En este proyecto se procederá también a realizar el diseño teórico de una parte móvil posterior en la que habrá una célula de concentración sobre la que se realizarán las medidas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a 5.3-Myr stack (the ''LR04'' stack) of benthic d18O records from 57 globally distributed sites aligned by an automated graphic correlation algorithm. This is the first benthic delta18O stack composed of more than three records to extend beyond 850 ka, and we use its improved signal quality to identify 24 new marine isotope stages in the early Pliocene. We also present a new LR04 age model for the Pliocene-Pleistocene derived from tuning the delta18O stack to a simple ice model based on 21 June insolation at 65 N. Stacked sedimentation rates provide additional age model constraints to prevent overtuning. Despite a conservative tuning strategy, the LR04 benthic stack exhibits significant coherency with insolation in the obliquity band throughout the entire 5.3 Myr and in the precession band for more than half of the record. The LR04 stack contains significantly more variance in benthic delta18O than previously published stacks of the late Pleistocene as the result of higher resolution records, a better alignment technique, and a greater percentage of records from the Atlantic. Finally, the relative phases of the stack's 41- and 23-kyr components suggest that the precession component of delta18O from 2.7-1.6 Ma is primarily a deep-water temperature signal and that the phase of d18O precession response changed suddenly at 1.6 Ma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiocarbon ages on CaCO3 from deep-sea cores offer constraints on the nature of the CaCO3 dissolution process. The idea is that the toll taken by dissolution on grains within the core top bioturbation zone should be in proportion to their time of residence in this zone. If so, dissolution would shift the mass distribution in favor of younger grains, thereby reducing the mean radiocarbon age for the grain ensemble. We have searched in vain for evidence supporting the existence of such an age reduction. Instead, we find that for water depths of more than 4 km in the tropical Pacific the radiocarbon age increases with the extent of dissolution. We can find no satisfactory steady state explanation and are forced to conclude that this increase must be the result of chemical erosion. The idea is that during the Holocene the rate of dissolution of CaCO3 has exceeded the rain rate of CaCO3. In this circumstance, bioturbation exhumes CaCO3 from the underlying glacial sediment and mixes it with CaCO3 raining from the sea surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some vols. have special title pages: t.43, Notes biographiques et bibliographiques sur les membres residants la Société des Antiquaries de Picardie, by Hector Josse. 1928; t.51, Séminaires et Formation du Clergé au Diocése d'Amiens by Henri Peltier.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Auteurs qui ont indiqué la cause des trombes": p. 184-185.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Réflexions sur l'exil, traduites de Bolingbroke": t.2, xxviii p.