937 resultados para Peak Expiratory Flow Rate
Resumo:
Mixing phenomena observed when the flow rate in a single loop of the primary circuit is changed can influence the operation of pressurized water reactor (PWR) by inducing local gradients of boron concentration or coolant temperature. Analysis of one-dimensional Laser Doppler Anemometry (LDA) measurements during the start-up and shutdown of pump on a single loop of the ROCOM test facility has been performed. The effect of a step change and a ramped change in the flow rate on the axial and azimuthal velocities was examined. Numerical simulations were also performed for the step change in the flow rate that gave quantitative agreement with the axial velocities. Phenomenological agreement was made on the turbulent kinetic energy; however, observed values were a factor of 2.5 less than the turbulent kinetic energy derived from the measurements. © 2007.
Resumo:
In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and ½, ¾, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2”x 2”, with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud.
Resumo:
OBJETIVO: Comparar os níveis de cortisol sérico e salivar, alfa-amilase salivar (sAA) e fluxo de saliva não estimulada (UWS) em gestantes e não gestantes. MÉTODOS: Trata-se de um estudo longitudinal realizado no centro de promoção da saúde de um hospital universitário. Nove gestantes e 12 não gestantes participaram do estudo. Foram coletados e analisados soro e UWS nos três trimestres gestacionais e duas vezes por mês durante o ciclo menstrual. A análise do cortisol salivar e sérico foi realizada com o uso de quimiluminescência e a atividade da sAA foi determinada por meio de analisador automático para bioquímica. RESULTADOS: Foi verificado que a mediana (intervalo interquartil) dos níveis de cortisol sérico no grupo de gestantes foi maior que 23,8 µL/dL (19,4-29,4) quando comparado ao grupo de não gestantes, que teve média de 12,3 (9,6-16,8; p<0,001). Os níveis de sAA seguiram o mesmo padrão, com médias de 56,7 U/L (30,9-82,2) e 31,8 (18,1-53,2; p<0,001), respectivamente. Foram observadas diferenças dos níveis de cortisol sérico e salivar (µL/dL) e de sAA entre a fase folicular versus a fase lútea (p<0,001). As medianas dos fluxos salivares (UWS) foram semelhantes em gestantes (0,26 [0,15-0,30] mL/min) e não gestantes (0,23 [0,20-0,32] mL/min). Foram encontradas correlações significativas entre o cortisol salivar e o sérico (p=0,02) e entre o cortisol salivar e a sAA (p=0,01). CONCLUSÕES: Os níveis de cortisol sérico de sAA durante a gestação elevam-se. Na fase lútea do ciclo ovariano, os níveis de cortisol salivar aumentam ao passo que os níveis de cortisol sérico e sAA diminuem. _______________________________________________________________________________________ ABSTRACT
Resumo:
Performance testing methods of boilers in transient operating conditions (start, stop and combustion power modulation sequences) need the combustion rate quantified to allow for the emissions to be quantified. One way of quantifying the combustion rate of a boiler during transient operating conditions is by measuring the flue gas flow rate. The flow conditions in chimneys of single family house boilers pose a challenge however, mainly because of the low flow velocity. The main objectives of the work were to characterize the flow conditions in residential chimneys, to evaluate the use of the Pitot-static method and the averaging Pitot method, and to develop and test a calibration method for averaging Pitot probes for low
Resumo:
The objective of this study is to examine the association between ambient temperature and children’s lung function in Baotou, China. We recruited 315 children (8–12 years) from Baotou, China in the spring of 2004, 2005, and 2006. They performed three successive forced expiratory measurements three times daily (morning, noon, and evening) for about 5 weeks. The highest peak expiratory flow (PEF) was recorded for each session. Daily data on ambient temperature, relative humidity, and air pollution were monitored during the same period. Mixed models with a distributed lag structure were used to examine the effects of temperature on lung function while adjusting for individual characteristics and environmental factors. Low temperatures were significantly associated with decreases in PEF. The effects lasted for lag 0–2 days. For all participants, the cumulative effect estimates (lag 0–2 days) were −1.44 (−1.93, −0.94) L/min, −1.39 (−1.92, −0.86) L/min, −1.40 (−1.97, −0.82) L/min, and −1.28 (−1.69, −0.88) L/min for morning, noon, evening, and daily mean PEF, respectively, associated with 1 °C decrease in daily mean temperature. Generally, the effects of temperature were slightly stronger in boys than in girls for noon, evening, and daily mean PEF, while the effects were stronger in girls for morning PEF. PM2.5 had joint effects with temperature on children’s PEF. Higher PM2.5 increased the impacts of low temperature. Low ambient temperatures are associated with lower lung function in children in Baotou, China. Preventive health policies will be required for protecting children from the cold weather.
Resumo:
Esta tese investiga os efeitos agudos da poluição atmosférica no pico de fluxo expiratório (PFE) de escolares com idades entre 6 e 15 anos, residentes em municípios da Amazônia Brasileira. O primeiro artigo avaliou os efeitos do material particulado fino (PM2,5) no PFE de 309 escolares do município de Alta Floresta, Mato Grosso (MT), durante a estação seca de 2006. Modelos de efeitos mistos foram estimados para toda a amostra e estratificados por turno escolar e presença de sintomas de asma. O segundo artigo expõe as estratégias utilizadas para a determinação da função de variância do erro aleatório dos modelos de efeitos mistos. O terceiro artigo analisa os dados do estudo de painel com 234 escolares, realizado na estação seca de 2008 em Tangará da Serra, MT. Avaliou-se os efeitos lineares e com defasagem distribuída (PDLM) do material particulado inalável (PM10), do PM2,5 e do Black Carbon (BC) no PFE de todos os escolares e estratificados por grupos de idade. Nos três artigos, os modelos de efeitos mistos foram ajustados por tendência temporal, temperatura, umidade e características individuais. Os modelos também consideraram o ajuste da autocorrelação residual e da função de variância do erro aleatório. Quanto às exposições, foram avaliados os efeitos das exposições de 5hs, 6hs, 12hs e 24hs, no dia corrente, com defasagens de 1 a 5 dias e das médias móveis de 2 e 3 dias. No que se refere aos resultados de Alta Floresta, os modelos para todas as crianças indicaram reduções no PFE variando de 0,26 l/min (IC95%: 0,49; 0,04) a 0,38 l/min (IC95%: 0,71; 0,04), para cada aumento de 10g/m3 no PM2,5. Não foram observados efeitos significativos da poluição no grupo das crianças asmáticas. A exposição de 24hs apresentou efeito significativo no grupo de alunos da tarde e no grupo dos não asmáticos. A exposição de 0hs a 5:30hs foi significativa tanto para os alunos da manhã quanto para a tarde. Em Tangará da Serra, os resultados mostraram reduções significativas do PFE para aumentos de 10 unidades do poluente, principalmente para as defasagens de 3, 4 e 5 dias. Para o PM10, as reduções variaram de 0,15 (IC95%: 0,29; 0,01) a 0,25 l/min (IC95%: 0,40 ; 0,10). Para o PM2,5, as reduções estiveram entre 0,46 l/min (IC95%: 0,86 to 0,06 ) e 0,54 l/min (IC95%: 0,95; 0,14). E no BC, a redução foi de aproximadamente 0,014 l/min. Em relação ao PDLM, efeitos mais importantes foram observados nos modelos baseados na exposição do dia corrente até 5 dias passados. O efeito global foi significativo apenas para o PM10, com redução do PFE de 0,31 l/min (IC95%: 0,56; 0,05). Esta abordagem também indicou efeitos defasados significativos para todos os poluentes. Por fim, o estudo apontou as crianças de 6 a 8 anos como grupo mais sensível aos efeitos da poluição. Os achados da tese sugerem que a poluição atmosférica decorrente da queima de biomassa está associada a redução do PFE de crianças e adolescentes com idades entre 6 e 15 anos, residentes na Amazônia Brasileira.
Resumo:
Rationale: Ex vivo, bronchial epithelial cells from people with asthma are more susceptible to rhinovirus infection caused by deficient induction of the antiviral protein, IFN-b. Exogenous IFN-b restores antiviral activity.
Objectives: To compare the efficacy and safety of inhaled IFN-b with placebo administered to people with asthma after onset of cold symptoms to prevent or attenuate asthma symptoms caused by respiratory viruses.
Methods: A total of 147 people with asthma on inhaled corticosteroids (British Thoracic Society Steps 2–5), with a history of virus-associated exacerbations, were randomized to 14-day treatment with inhaled IFN-b (n = 72) or placebo (n = 75) within 24 hours of developing cold symptoms and were assessed clinically, with relevant samples collected to assess virus infection and antiviral responses.
Measurements and Main Results: A total of 91% of randomized patients developed a defined cold. In this modified intention-to-treat population, asthma symptoms did not get clinically significantly worse
(mean change in six-item Asthma Control Questionnaire ,0.5) and IFN-b treatment had no significant effect on this primary endpoint, although it enhanced morning peak expiratory flow recovery (P = 0.033), reduced the need for additional treatment, and boosted innate immunity as assessed by blood and sputum biomarkers. In an exploratory analysis of the subset ofmore difficult-to-treat, Step 4-5 peoplewith asthma (n = 27 IFN-b; n = 31 placebo), Asthma Control Questionnaire-6 increased significantly on placebo; this was prevented by IFN-b (P = 0.004).
Conclusions: Although the trial did not meet its primary endpoint, it suggests that inhaled IFN-b is a potential treatment for virus-induced deteriorations of asthma in difficult-to-treat people with asthma and supports the needforfurther, adequately powered, trialsin this population. Clinical trial registered with www.clinicaltrials.gov (NCT 01126177).
Resumo:
Introduction: L’asthme relié au travail (ART) est induit ou aggravé par le milieu du travail. L’asthme professionnel (AP) et l’asthme exacerbé au travail (AET) sont difficiles à distinguer en pratique clinique puisque dans les deux conditions les travailleurs se plaignent d’une détérioration de leur asthme au travail. De plus, les médecins sont souvent confrontés à des patients ayant des symptômes respiratoires reliés au travail (SRT) sans être asthmatiques. Ces patients sont souvent exclus des études qui visent à mieux caractériser l’ART. Objectifs : 1. Comparer la variabilité quotidienne des débits expiratoires de pointe (DEP) durant les périodes au et hors travail chez des sujets atteints d’AP et d’AET. 2. Évaluer la prévalence des patients ayant des SRT parmi les sujets référés pour possibilité d’ART, et comparer leurs caractéristiques et leur environnement professionnel avec ceux ayant l’ART. Résultats : L’exposition professionnelle induit une variabilité accrue des DEP chez les sujets avec AP et AET mais celle-ci est plus prononcée dans l’AP. Les sujets ayant des SRT sans être asthmatiques représentent une grande proportion des sujets référés pour possibilité d’ART. Conclusions : L’ART devrait être considéré chez tous les individus qui présentent un asthme de novo, ou une aggravation de leur asthme. La similitude des symptômes entre les sujets ayant des SRT et l’ART rend nécessaire d’effectuer une évaluation extensive. Cette évaluation devrait se faire selon une approche par étapes dans laquelle des tests objectifs améliorent la certitude du diagnostic et aident à différencier entre l’AP et l’AET.
Resumo:
Evaluar si el Heliox reduce la resistencia en la vía aérea en niños y adolescentes con patología bronquial obstructiva que requieren ventilación mecánica. Materiales y Métodos: Estudio prospectivo observacional descriptivo en niños y adolescentes con patología bronquial obstructiva y ventilación mecánica con Fi02 ≤ 0,5. Medición de variables: resistencia, presión pico, presión media de la vía aérea, presión meseta, volumen corriente, autoPEEP, distensibilidad, PetCO2, ventilación de espacio muerto antes de inicio de heliox y a los 30 minutos, 2, 4, 6, 12, 18 y 24 horas y diariamente hasta suspenderlo por extubación o FiO2 > 0,5. Resultados: Resultados parciales, incluyó 9 pacientes encontrando descenso significativo de resistencia espiratoria a los 30 minutos (51,2 vs 32,3; p=0,0008 ), 2 horas ( 51,2 vs 33,4; p=0,0019) y 4 horas (51,2 vs 30,7; p=0,0012) así como de la resistencia inspiratoria a la hora 2 (48,6 vs 36,2; p = 0,013) y hora 4 (48,6 vs 30 ; p=0,004). Se observó tendencia al descenso de la PetCO2 que no fue significativa (52,3 vs 34,3: p=0,06). No se evidenció cambios en las variables; autoPEEP, presión pico, presión media de la vía aérea, distensibilidad, ventilación de espacio muerto, presión meseta y volumen corriente antes y después del inicio del Heliox. Conclusión: La ventilación mecánica con Heliox en niños con patología bronquial obstructiva parece ser que reduce de manera significativa la resistencia de la vía aérea, con tendencia al descenso de la PetC02. Se necesitan estudios prospectivos al menos observacionales analíticos que corroboren estos hallazgos.
Resumo:
Introducción: En Colombia la investigación sobre condiciones de trabajo y salud en minería carbonífera es escasa y no considera la percepción de la población expuesta y sus comportamientos frente a los riesgos inherentes. Objetivo: Determinar la asociación entre las condiciones de trabajo y morbilidad percibidas entre trabajadores de minas de carbón en Guachetá, Cundinamarca. Materiales y métodos: Se realizó un estudio transversal con 154 trabajadores seleccionados aleatoriamente del total registrado en la alcaldía municipal. Se indagó sobre características sociodemográficas, condiciones de trabajo y salud en las minas. Se estimaron prevalencias de los trastornos respiratorios, osteomusculares y auditivos, y se exploraron las asociaciones entre algunas condiciones de trabajo y los eventos con prevalencia superior a 30% de forma bivariada y múltiple, con regresiones Poisson con varianza robusta. Resultados: Los trabajadores fueron en su mayoría hombres, con edades entre 18 y 77 años de edad. Los problemas de salud más frecuentemente reportados fueron dolor lumbar (46,10%), dolor del miembro superior (40,26%), dolor del miembro inferior (34,42%), trastornos respiratorios (17,53%) y problemas auditivos (13,64%). Existen diferencias importantes en la percepción dependiendo de la antigüedad laboral y las condiciones subterráneas o no del trabajo. Conclusión: Los riesgos más reconocidos por los trabajadores son los relacionados con trastornos osteomusculares, al parecer por ser más evidentes en su cotidianidad. Las acciones en salud ocupacional podrán considerar estos hallazgos en sus planes de prevención de la enfermedad en las minas del carbón colombianas.
Resumo:
OBJETIVOS: Avaliar os efeitos da utilização do biofeedback respiratório (BR) associado ao padrão quiet breathing sobre a perimetria torácica, função pulmonar, força dos músculos respiratórios e os seguintes hábitos de respiradores bucais funcionais (RBF): vigília de boca aberta, boca aberta durante o sono, baba no travesseiro, despertar difícil, ronco e sono inquieto. MÉTODOS: Foram avaliadas 20 crianças RBF, as quais foram submetidas a 15 sessões de BR por meio do biofeedback pletsmovent (MICROHARD® V1.0), o qual proporciona o biofeedback dos movimentos tóraco-abdominais. Perimetria torácica, espirometria e medidas das pressões respiratórias máximas estáticas foram realizadas antes e após a terapia. Questões respondidas pelos responsáveis foram utilizadas para avaliar os hábitos dos RBF. Os dados foram analisados por meio de teste t de Student para dados pareados e testes não paramétricos. RESULTADOS: O uso do BR associado ao padrão quiet breathing não produziu alterações significativas na perimetria torácica e nos valores de volume expiratório forçado no primeiro segundo (VEF1), capacidade vital forçada (CVF), pico de fluxo expiratório (PFE), índice de Tiffeneau (IT) e na pressão expiratória máxima (PEmáx). Entretanto, a pressão inspiratória máxima (PImáx) apresentou diferença estatisticamente significativa (-53,6 ± 2,9 cmH2O vs. -65,0 ± 6,0 cmH2O; p< 0,05) e ocorreram mudanças significativas nos hábitos avaliados. CONCLUSÃO: Os resultados permitem concluir que o BR associado ao padrão quiet breathing melhora a força da musculatura inspiratória e hábitos em RBF, podendo ser, portanto, utilizado como uma das formas de terapia nesses indivíduos.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This 12-week study compared the efficacy and safety of a fixed combination of fluticasone propionate plus formoterol (FL/F) 250/12 mu g b.i.d. administered via a dry powder inhaler (DPI) (Libbs Farmaceutica, Brazil) to a combination of budesonide plus formoterol (BD/F) 400/12 mu g b.i.d. After a 2-week run-in period (in which all patients were treated exclusively with budesonide plus formoterol), patients aged 12-65 years of age (N = 196) with uncontrolled asthma were randomized into an actively-controlled, open-labeled, parallel-group, multicentre, phase III study. The primary objective was to demonstrate non-inferiority, measured by morning peak expiratory flow (mPEF).The non-inferiority was demonstrated. A statistically significant improvement from baseline was observed in both groups in terms of lung function, asthma control, and the use of rescue medication. FL/F demonstrated a statistical superiority to BD/F in terms of lung function (FEV1) (p = 0.01) and for asthma control (p = 0.02). Non-significant between-group differences were observed with regards to exacerbation rates and adverse events.In uncontrolled or partly controlled asthma patients, the use of a combination of fluticasone propionate plus formoterol via DPI for 12-weeks was non-inferior and showed improvements in FEV1 and asthma control when compared to a combination of budesonide plus formoterol. (Clinical Trial number: ISRCTN60408425). (C) 2013 Elsevier Ltd. All rights reserved.