961 resultados para POWER-SPECTRUM ANALYSIS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: to describe the patterns of the gastric myoelectrical activity, pre-and postprandially, in clinically stable neonates of different gestational ages, during their first two weeks of life by means of Electrogastrography. PATIENTS AND METHODS: Electrogastrography was recorded in forty-five clinically stable neonates of different gestational ages (group I: 15 neonates of > 37 weeks, group II: 15 premature neonates of 32-37 weeks; Group III: 15 premature neonates of 28-31 weeks) receiving intermittent enteral feedings during their first two weeks of life. Electrogastrography recordings were performed for 1 hour pre-and postprandially. The Electrogastrography signal was recorded using the portable MicroDigitrapper Electrogastrography recording device and after motion artifacts were deleted, the remaining Electrogastrography data were submitted to quantitative analysis based on the "Running Spectrum Analysis". RESULTS: The percentages of normogastria, pre-and postprandially were greater than the percentages of gastric dysrythmias in all three studied groups. Furthermore, all neonates had the mean values of the Electrogastrography dominant frequency predominantly within the normogastria range, in both periods analyzed. There were no significant differences in the relative change of the Electrogastrography dominant power among the groups. CONCLUSION: This study demonstrates that the Electrogastrography patterns are similar between premature and full term neonates during the pre-and postprandial periods. The results of this study also indicate that the gastric myoelectrical activity in premature and full term neonates is immature, as compared to that described for older neonates, children and adults.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present paper focuses on a damage identification method based on the use of the second order spectral properties of the nodal response processes. The explicit dependence on the frequency content of the outputs power spectral densities makes them suitable for damage detection and localization. The well-known case study of the Z24 Bridge in Switzerland is chosen to apply and further investigate this technique with the aim of validating its reliability. Numerical simulations of the dynamic response of the structure subjected to different types of excitation are carried out to assess the variability of the spectrum-driven method with respect to both type and position of the excitation sources. The simulated data obtained from random vibrations, impulse, ramp and shaking forces, allowed to build the power spectrum matrix from which the main eigenparameters of reference and damage scenarios are extracted. Afterwards, complex eigenvectors and real eigenvalues are properly weighed and combined and a damage index based on the difference between spectral modes is computed to pinpoint the damage. Finally, a group of vibration-based damage identification methods are selected from the literature to compare the results obtained and to evaluate the performance of the spectral index.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the heart rate variability in patients with mild to moderate systemic arterial hypertension. METHODS: Thirty-two healthy (group I) and 70 systemic arterial hypertensive (group II) individuals, divided according to age (40 to 59 and 60 to 80 years old, respectively) and with a similar distribution by sex were studied. Thirty-one had left ventricular hypertrophy (LVH), 22 were overweight, and 16 had Type II diabetes mellitus. Smoking, alcohol ingestion, and sedentary habits were the same between groups. Variability in heart rate was analyzed in the time domain, using standard deviations of normal RR intervals (SDNN) and the differences between maximal brady- and tachycardia (D-BTmax) during sustained inspiration. Analysis of the frequency band of the power spectrum between 0.05 and 0.40 Hz at rest and during controlled respiration was chosen for analysis of the frequency domain. RESULTS: In both time and frequency domains, variables were lower in group II than in group I. Within groups, statistically significant variables were only found for individuals in the 40 to 59 year old group. The presence of LVH, overweight, or diabetes mellitus did not influence the variability in heart rate to a significant extent. CONCLUSION: Variability in heart rate was a valuable instrument for analyzing autonomic modulation of the heart in arterial hypertension. The autonomic system undergoes significant losses in cardio-modulatory capacity, more evident in subjects between 40 and 59 years old. In those over 60 years old, reduced variability in heart rate imposed by aging was not significantly influenced by the presence of systemic arterial hypertension.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Our new simple method for calculating accurate Franck-Condon factors including nondiagonal (i.e., mode-mode) anharmonic coupling is used to simulate the C2H4+X2B 3u←C2H4X̃1 Ag band in the photoelectron spectrum. An improved vibrational basis set truncation algorithm, which permits very efficient computations, is employed. Because the torsional mode is highly anharmonic it is separated from the other modes and treated exactly. All other modes are treated through the second-order perturbation theory. The perturbation-theory corrections are significant and lead to a good agreement with experiment, although the separability assumption for torsion causes the C2 D4 results to be not as good as those for C2 H4. A variational formulation to overcome this circumstance, and deal with large anharmonicities in general, is suggested

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The plume generated by ablation of hydroxyapatite targets under ArF excimer laser irradiation has been investigated by means of fast intensified CCD-imaging and optical emission spectroscopy. Results have shown that the plume splits into two plasma clouds as it expands. Time and spatial resolved spectra have revealed that under the experiment conditions emission is mostly due to calcium neutral atoms and calcium oxide molecular radicals. Imaging of the plume with the aid of bandpass filters has demonstrated that the emissive species in the larger and faster plasma cloud are calcium neutral atoms, whereas in the smaller and slower one they are calcium oxide molecular radicals

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: To compare the power spectral changes of the voluntary surface electromyogram (sEMG) and of the compound action potential (M wave) in the vastus medialis and vastus lateralis muscles during fatiguing contractions. METHODS: Interference sEMG and force were recorded during 48 intermittent 3-s isometric maximal voluntary contractions (MVC) from 13 young, healthy subjects. M waves and twitches were evoked using supramaximal femoral nerve stimulation between the successive MVCs. Mean frequency (F mean), and median frequency were calculated from the sEMG and M waves. Muscle fiber conduction velocity (MFCV) was computed by cross-correlation. RESULTS: The power spectral shift to lower frequencies was significantly greater for the voluntary sEMG than for the M waves (P < 0.05). Over the fatiguing protocol, the overall average decrease in MFCV (~25 %) was comparable to that of sEMG F mean (~22 %), but significantly greater than that of M-wave F mean (~9 %) (P < 0.001). The mean decline in MFCV was highly correlated with the mean decreases in both sEMG and M-wave F mean. CONCLUSIONS: The present findings indicated that, as fatigue progressed, central mechanisms could enhance the relative weight of the low-frequency components of the voluntary sEMG power spectrum, and/or the end-of-fiber (non-propagating) components could reduce the sensitivity of the M-wave spectrum to changes in conduction velocity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We consider a model for a damped spring-mass system that is a strongly damped wave equation with dynamic boundary conditions. In a previous paper we showed that for some values of the parameters of the model, the large time behaviour of the solutions is the same as for a classical spring-mass damper ODE. Here we use spectral analysis to show that for other values of the parameters, still of physical relevance and related to the effect of the spring inner viscosity, the limit behaviours are very different from that classical ODE

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, one of the most important challenges to enhance the efficiency of thin film silicon solar cells is to increase the short circuit intensity by means of optical confinement methods, such as textured back-reflector structures. In this work, two possible textured structures to be used as back reflectors for n-i-p solar cells have been optically analyzed and compared to a smooth one by using a system which is able to measure the angular distribution function (ADF) of the scattered light in a wide spectral range (350-1000 nm). The accurate analysis of the ADF data corresponding to the reflector structures and to the μc-Si:H films deposited onto them allows the optical losses due to the reflector absorption and its effectiveness in increasing light absorption in the μc-Si:H layer, mainly at long wavelengths, to be quantified.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diplomityössä esitellään menetelmiä sauvarikon toteamiseksi. Työn tarkoituksena on tutkia roottorivaurioita staattorivirran avulla. Työ jaetaan karkeasti kolmeen osa-alueeseen: oikosulkumoottorin vikoihin, roottorivaurioiden tunnistamiseen ja signaalinkäsittelymenetelmiin, jonka avulla havaitaan sauvarikko. Oikosulkumoottorin vikoja ovat staattorikäämien vauriot ja roottorivauriot. Roottorikäämien vaurioita ovat roottori sauvojen murtuminen sekä roottorisauvan irtoaminen oikosulkujenkaan päästä. Roottorivaurioiden tunnistamismenetelmiä ovat parametrin arviointi ja virtaspektrianalyysi. Työn alkuosassa esitellään oikosulkumoottorien rakenne ja toiminta. Esitellään moottoriin kohdistuvia vikoja ja etsitään ratkaisumenetelmiä roottorivaurioiden tunnistamisessa. Lopuksi tutkitaan, kuinka staattorimittaustietojen perusteella saadut tulokset voidaan käsitellä FFT -algoritmilla ja kuinka FFT -algoritmi voidaan toteuttaa sulautettuna Sharc -prosessorin avulla. Työssä käytetään ADSP 21062 EZ -LAB kehitysympäristöä, jonka avulla voidaan ajaa ohjelmia RAM-sirusta, joka on vuorovaikutuksessa SHARC -laudassa oleviin laitteisiin.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

ABSTRACT Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.