997 resultados para Myocardial Perfusion Imaging
Resumo:
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
Resumo:
BACKGROUND: The purpose of the present study was to investigate the diagnostic value of T2-mapping in acute myocarditis (ACM) and to define cut-off values for edema detection. METHODS: Cardiovascular magnetic resonance (CMR) data of 31 patients with ACM were retrospectively analyzed. 30 healthy volunteers (HV) served as a control. Additionally to the routine CMR protocol, T2-mapping data were acquired at 1.5 T using a breathhold Gradient-Spin-Echo T2-mapping sequence in six short axis slices. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values as well as the segmental pixel-standard deviation (SD) were analyzed. RESULTS: Mean differences of global myocardial T2 or pixel-SD between HV and ACM patients were only small, lying in the normal range of HV. In contrast, variation of segmental T2 values and pixel-SD was much larger in ACM patients compared to HV. In random forests and multiple logistic regression analyses, the combination of the highest segmental T2 value within each patient (maxT2) and the mean absolute deviation (MAD) of log-transformed pixel-SD (madSD) over all 16 segments within each patient proved to be the best discriminators between HV and ACM patients with an AUC of 0.85 in ROC-analysis. In classification trees, a combined cut-off of 0.22 for madSD and of 68 ms for maxT2 resulted in 83% specificity and 81% sensitivity for detection of ACM. CONCLUSIONS: The proposed cut-off values for maxT2 and madSD in the setting of ACM allow edema detection with high sensitivity and specificity and therefore have the potential to overcome the hurdles of T2-mapping for its integration into clinical routine.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) é um dos exames complementares de diagnóstico mais indicados na patologia cardiovascular. A atividade extramiocárdica é um problema recorrente na aquisição e avaliação da imagem. Parâmetros como o radiofármaco (RF) administrado, o tipo de esforço, a ingestão de alimentos, o posicionamento e o processamento de imagem influenciam a atividade extramiocárdica na CPM. O objetivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições das aquisições provocadas por este problema. Metodologia – Para a realização deste estudo, a população selecionada foram os Serviços de Medicina Nuclear (SMN) em Portugal Continental. Foram analisados 15 questionários, respondidos pelos Técnicos Coordenadores dos vários SMN. Foi realizada a associação do comportamento das variáveis, através da estatística descritiva e do Coeficiente de Correlação de Spearman. Resultados – A percentagem de repetições é menor com o uso da 99mTecnécio(Tc)-Tetrofosmina, aquisição de imagens tardias, ingestão de diversos alimentos (água, leite, sumo, pão com manteiga) e com a correção de atenuação. Conclusão – Os resultados obtidos demonstram que a maioria das soluções aplicadas nos SMN resultam numa diminuição das repetições.
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia
Resumo:
We report a rare case of anomalous origin of the left coronary artery from the pulmonary trunk in a 45-year-old woman. The approach and technique used for selective catheterization of an anomalous left coronary artery arising from the pulmonary trunk are described. Six years after diagnosis, echocardiography showed left ventricular disfunction, and surgical treatment was indicated again. The origin of the left coronary artery from the pulmonary trunk was closed, and the postoperative period was uneventful, with recovery of left ventricular function and disappearance of ischemic features on stress myocardial perfusion imaging with 99m Tc-sestamibi, performed 4 weeks after surgery.
Resumo:
AbstractBackground:Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001).Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.
Resumo:
Purpose: Recent studies showed that pericardial fat was independently correlated with the development of coronary artery disease (CAD). The mechanism remains unclear. We aimed at assessing a possible relationship between pericardial fat volume and endothelium-dependent coronary vasomotion, a surrogate of future cardiovascular events.Methods: Fifty healthy volunteers without known CAD or cardiovascular risk factors (CRF) were enrolled. They all underwent a dynamic Rb- 82 cardiac PET/CT to quantify myocardial blood flow (MBF) at rest, during MBF response to cold pressure test (CPT-MBF) and adenosine stress. Pericardial fat volume (PFV) was measured using a 3D volumetric CT method and common biological CRF (glucose and insulin levels, HOMA-IR, cholesterol, triglyceride, hs-CRP). Relationships between MBF response to CPT, PFV and other CRF were assessed using non-parametric Spearman correlation and multivariate regression analysis of variables with significant correlation on univariate analysis (Stata 11.0).Results: All of the 50 participants had normal MBF response to adenosine (2.7±0.6 mL/min/g; 95%CI: 2.6−2.9) and myocardial flow reserve (2.8±0.8; 95%CI: 2.6−3.0) excluding underlying CAD. Simple regression analysis revealed a significant correlation between absolute CPTMBF and triglyceride level (rho = −0.32, p = 0.024) fasting blood insulin (rho = −0.43, p = 0.0024), HOMA-IR (rho = −0.39, p = 0.007) and PFV (rho = −0.52, p = 0.0001). MBF response to adenosine was only correlated with PFV (rho = −0.32, p = 0.026). On multivariate regression analysis PFV emerged as the only significant predictor of MBF response to CPT (p = 0.002).Conclusion: PFV is significantly correlated with endothelium-dependent coronary vasomotion. High PF burden might negatively influence MBF response to CPT, as well as to adenosine stress, even in persons with normal hyperemic myocardial perfusion imaging, suggesting a link between PF and future cardiovascular events. While outside-to-inside adipokines secretion through the arterial wall has been described, our results might suggest an effect upon NO-dependent and -independent vasodilatation. Further studies are needed to elucidate this mechanism.
Resumo:
INTRODUCTION: Diabetic patients are at high risk for coronary artery disease (CAD), which is the leading cause of death in this population. The Swiss Society of Endocrinology-Diabetology (SSED) recommends CAD screening for diabetic patients with > or = 2 additional cardiovascular risk factors (CVRF), by stress echocardiography (SE) or myocardial perfusion imaging (MPI). The aim of this study was to assess the application of these guidelines and the treatment of CVRF in the diabetes outpatient clinics of the five Swiss University Hospitals. METHODS: The study was initiated in Lausanne and the study questionnaires were circulated to the endocrinologists of the five Swiss University Hospitals. Practitioners were asked to include consecutive patients attending the diabetes outpatient clinics over one month. Prevalence of CAD, screening methods for CAD, prevalence of CVRF, biological analyses over the last 6 months and medical therapy were recorded. RESULTS: A total of 302 subjects were included. The mean age was 53 +/- 14 years, 68% had type 2 diabetes, 27% type 1 and 5% other types. Among T2DM with > or = 2 CVRF, 45% were screened for CAD according to SSED guidelines. In T2DM 25% had blood pressure < or = 130/80 mm Hg, 15% a lipid profile within target, 23% HbA1c < or = 7.0%. Overall, 2% achieved all 3 targets. CONCLUSIONS: Only 45% of T2DM with > or = 2 CVRF were screened for CAD according to SSED guidelines and 2% of T2DM had proper control over all CVRF. Efforts are still necessary to improve CAD prevention and screening of diabetic patients in Swiss University Hospitals.
Resumo:
RESUME Objectifs. Évaluer la prévalence de maladie coronarienne chez les patients diabétiques de type 2 asymptomatiques ou avec angor atypique selon les recommandations américaines de l'American Diabetes Association et de l'American College of Cardiology. Méthodes. Cent cinquante-quatre patients diabétiques de type 2 asymptomatiques ou avec angor atypique et présentant au minimum 2 facteurs de risque cardio-vasculaires additionnels ont été dépistés par échocardiographie de stress (71%, n=109), scintigraphie myocardique de perfusion (26%, n=40) ou l'association des 2 examens (3%, n=5). Résultats. L'échocardiographie de stress s'est révélée positive chez 16 patients (14%) et 14 ont eu une coronarographie révélant des sténoses significatives chez 12 (86%). La scintigraphie myocardique de perfusion était positive chez 16 patients (36%). Huit patients ont eu une coronarographie et 4 (50%) présentaient des sténoses significatives. Au total, 31 patients (20%) ont montré des signes d'ischémie lors de l'examen non-invasif et 15 (10%) ont présenté des sténoses significatives à la coronarographie. Les facteurs prédictifs indépendants de la maladie coronarienne étaient le tabagisme (OR 6.5, p=0.05), la microalbuminurie (OR 3.9, p=0.03), ainsi que les souffles fémoraux (OR 17.1, p=0.008). Conclusions. En suivant les recommandations américaines, un patient sur cinq présentait une ischémie lors des examens non-invasifs, tandis que 1 sur 10 avait des sténoses significatives à la coronarographie. L'analyse multivariée suggère que des marqueurs des complications micro- et macro-vasculaires en combinaison avec des facteurs de risque cardio-vasculaire classiques pourraient améliorer le pouvoir diagnostic de ces recommandations. SUMMARY Aims. We evaluated the prevalence of coronary artery disease in asymptomatic and atypical chest pain type 2 diabetic patients according to the American Diabetes Association and American College of Cardiology guidelines. Methods. Asymptomatic or atypical chest pain type 2 diabetic patients (n=154), with at least two additional cardiovascular risk factors, were screened for coronary artery disease using stress echocardiography (71%, n=109), myocardial perfusion imaging (26%, n=40) or both (3%, n=5). Results. Stress echocardiography was positive in 16 patients (14%) and 14 had a coronary angiography, revealing significant stenoses in 12 (86%). Myocardial perfusion imaging was positive in 16 patients (36%). Eight patients underwent angiography and 4 (50%) presented significant stenoses. Overall, 31 patients (20%) demonstrated signs of ischemia on non-invasive tests and 15 (10%) presented significant stenoses on coronary angiography. Independent predictors of coronary artery disease were smoking (OR 6.5, p=0.05), microalbuminuria (OR 3.9, p=0.03) and femoral murmur (OR 17.1, p=0.008). Conclusions. Following the guidelines, one in five diabetic patient presented ischemia on noninvasive tests, while one in ten presented significant coronary stenoses. Multivariate analysis suggests that adding markers of micro- and macro-vascular complications to classical cardiovascular risk factors may enhance the diagnostic efficiency of the guidelines.
Resumo:
The coronary artery calcium (CAC) score is a readily and widely available tool for the noninvasive diagnosis of atherosclerotic coronary artery disease (CAD). The aim of this study was to investigate the added value of the CAC score as an adjunct to gated SPECT for the assessment of CAD in an intermediate-risk population. METHODS: Seventy-seven prospectively recruited patients with intermediate risk (as determined by the Framingham Heart Study 10-y CAD risk score) and referred for coronary angiography because of suspected CAD underwent stress (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging (MPI) and CT CAC scoring within 2 wk before coronary angiography. The sensitivity and specificity of SPECT alone and of the combination of the 2 methods (SPECT plus CAC score) in demonstrating significant CAD (>/=50% stenosis on coronary angiography) were compared. RESULTS: Forty-two (55%) of the 77 patients had CAD on coronary angiography, and 35 (45%) had abnormal SPECT results. The CAC score was significantly higher in subjects with perfusion abnormalities than in those who had normal SPECT results (889 +/- 836 [mean +/- SD] vs. 286 +/- 335; P < 0.0001). Similarly, with rising CAC scores, a larger percentage of patients had CAD. Receiver-operating-characteristic analysis showed that a CAC score of greater than or equal to 709 was the optimal cutoff for detecting CAD missed by SPECT. SPECT alone had a sensitivity and a specificity for the detection of significant CAD of 76% and 91%, respectively. Combining SPECT with the CAC score (at a cutoff of 709) improved the sensitivity of SPECT (from 76% to 86%) for the detection of CAD, in association with a nonsignificant decrease in specificity (from 91% to 86%). CONCLUSION: The CAC score may offer incremental diagnostic information over SPECT data for identifying patients with significant CAD and negative MPI results.
Resumo:
Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients. METHODS: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with (99m)Tc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion. RESULTS: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P<0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P=0.004) and involvement of diagonal branches (P=0.01). CONCLUSION: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.
Resumo:
Background Gray scale images make the bulk of data in bio-medical image analysis, and hence, the main focus of many image processing tasks lies in the processing of these monochrome images. With ever improving acquisition devices, spatial and temporal image resolution increases, and data sets become very large. Various image processing frameworks exists that make the development of new algorithms easy by using high level programming languages or visual programming. These frameworks are also accessable to researchers that have no background or little in software development because they take care of otherwise complex tasks. Specifically, the management of working memory is taken care of automatically, usually at the price of requiring more it. As a result, processing large data sets with these tools becomes increasingly difficult on work station class computers. One alternative to using these high level processing tools is the development of new algorithms in a languages like C++, that gives the developer full control over how memory is handled, but the resulting workflow for the prototyping of new algorithms is rather time intensive, and also not appropriate for a researcher with little or no knowledge in software development. Another alternative is in using command line tools that run image processing tasks, use the hard disk to store intermediate results, and provide automation by using shell scripts. Although not as convenient as, e.g. visual programming, this approach is still accessable to researchers without a background in computer science. However, only few tools exist that provide this kind of processing interface, they are usually quite task specific, and don’t provide an clear approach when one wants to shape a new command line tool from a prototype shell script. Results The proposed framework, MIA, provides a combination of command line tools, plug-ins, and libraries that make it possible to run image processing tasks interactively in a command shell and to prototype by using the according shell scripting language. Since the hard disk becomes the temporal storage memory management is usually a non-issue in the prototyping phase. By using string-based descriptions for filters, optimizers, and the likes, the transition from shell scripts to full fledged programs implemented in C++ is also made easy. In addition, its design based on atomic plug-ins and single tasks command line tools makes it easy to extend MIA, usually without the requirement to touch or recompile existing code. Conclusion In this article, we describe the general design of MIA, a general purpouse framework for gray scale image processing. We demonstrated the applicability of the software with example applications from three different research scenarios, namely motion compensation in myocardial perfusion imaging, the processing of high resolution image data that arises in virtual anthropology, and retrospective analysis of treatment outcome in orthognathic surgery. With MIA prototyping algorithms by using shell scripts that combine small, single-task command line tools is a viable alternative to the use of high level languages, an approach that is especially useful when large data sets need to be processed.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) é utilizada no diagnóstico e seguimento de pacientes com doença arterial coronária, sendo a sua avaliação frequentemente realizada através da análise visual dos cortes tomográficos. A escala de cores selecionada é essencial na interpretação clínica das imagens de perfusão do miocárdio. Objetivo – Avaliar a influência de diferentes escalas de cores na avaliação qualitativa das imagens de CPM e estudar quais as mais adequadas para análise visual. Métodos – Trinta e cinco estudos de CPM foram avaliados visualmente por 16 estudantes da licenciatura em medicina nuclear nas escalas de cores Cool, Gray, Gray Invert, Thermal e Warm. Para a escala de cores Cool, a análise das imagens de CPM foi realizada através de um sistema de classificação semiquantitativo por scores. As restantes escalas de cores foram avaliadas por comparação com a análise das imagens efetuada com escala de cores Cool. Resultados/Discussão – Para a escala de cores Cool, a variabilidade interoperador revelou a existência de diferenças estatisticamente significativas entre todos os participantes (p<0,05), o que se pode atribuir à subjetividade da avaliação visual. Os resultados relativos às escalas de cores Gray e Gray Invert foram os mais próximos da perfusão do miocárdio observada com a escala Cool, considerando-se escalas de cores alternativas na análise visual dos estudos de CPM. Para as escalas de cores Thermal e Warm os resultados foram mais divergentes, não se considerando adequadas para a avaliação visual dos estudos de CPM. Conclusão – A escala de cores influencia a avaliação qualitativa da perfusão na CPM.
Resumo:
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.