983 resultados para Measurement of performance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dilution refrigerator has been constructed capable of producing steady state temperatures less than .075°K. The first part of this work is concerned with the design and construction of this machine. Enough theory is presented to allow one to understand the operation and critical design factors of a dilution refrigerator. The performance of our refrigerator is compared with the operating characteristics of three other dilution refrigerators appearing in the present literature.

The dilution refrigerator constructed was used to measure the nuclear contribution to the low temperature specific heat of a pure, single-crystalline sample of rhenium metal. Measurements were made in magnetic fields from 0 to 12.5 kOe for the temperature range .13°K - .52°K. The second part of this work discusses the results of these experiments. The expected nuclear contribution is not found when the sample is in the superconducting state. This is believed to be due to the long spin-lattice relaxation times in superconductors. In the normal state, for the temperature range studied, the nuclear contribution is given by A/T2 where A = .061 ± .002 millijoules-K/mole. The value of A is found to increase to A = .077 ± .004 millijoules-K/mole when the sample is located in a magnetic field of 12.5 kOe.

From the measured value of A the splitting of the energy levels of the nuclear spin system due to the interaction of the internal crystalline electric field gradients with the nuclear quadrupole moments is calculated. A comparison is made between the predicted and measured magnetic dependence of the specific heat. Finally, predictions are made of future nuclear magnetic resonance experiments which may be performed to check the results obtained by calorimetery here and further, to investigate existing theories concerning the sources of electric field gradients in metals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of high efficiencies, compact structure, and excellent heat dissipation, high-power fiber lasers are extremely useful for applications such as cutting, welding, precision drilling, trimming, sensing, optical transmitter, material processing, micromachining, and so on. However, the wavefront of the double clad fiber laser doped with ytterbium is still unknown. In this paper, wavefront of a fiber laser is measured and the traditional Hartmann-shack wavefront sensing method is adopted. We measured a double clad fiber laser doped with ytterbium which produces pulse wave output at infrared wavelength. The wavefront shape and contour are reconstructed and the result shows that wavefront is slightly focused and not an ideal plane wavefront. Wavefront measurement of fiber laser will be useful to improving the lasers' performance and developing the coherent technique for its applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method of measuring cylinder gas temperature in an internal combustion engine cylinder is introduced. The physical basis for the technique is that the flow rate through an orifice is a function of the temperature of the gas flowing through the orifice. Using a pressure transducer in the cylinder, and another in a chamber connected to the cylinder via an orifice, it is shown how the cylinder temperature can be determined with useful sensitivity. In this paper the governing equations are derived, which show that the heat transfer characteristics of the chamber are critical to the performance of the system, and that isothermal or adiabatic conditions give the optimum performance. For a typical internal combustion engine, it is found that the pre-compression cylinder temperature is related to the chamber pressure late in the compression process with sensitivity of the order of 0.005 bar/K. Copyright © 2010 SAE International.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new sensitive assay for aspartate aminotransterase (AST) and alanine aminotransferase (ALT) activities in biofluids was developed, based on the separation and detection of alanine, glutamate, and aspartate using capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. The three amino acids were separated in 5 mM phosphate of pH 2.1 as background electrolyte, and detected on a 500 mu m platinum disk electrode at 1.2 V (versus Ag/AgCl) in the presence of 10 mM tris(2,2'-bipyridyl)ruthenium(II) dissolved in 80 mM phosphate of pH 10.5. A mass detection limit of 37.3 fmol (or 81.5 fmol) for glutamate, corresponding to the product in the enzyme reaction catalyzed by 1.24 x 10(-9) U AST (or 2.72 x 10(-9) U ALT) in a 30 min reaction period, was achieved. This assay was applied to investigate the cytotoxicity effect of ethanol on HepG2 cells and differentiating nonalcoholic steatohepatitis (NASH) from alcoholic liver disease, indicating that the technique is promising for the application in the cell biological and clinical fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principal objective of this thesis was to investigate the ability of reversible optical O2 sensors to be incorporated into food/beverage packaging systems to continuously monitor O2 levels in a non-destructive manner immediately postpackaging and over time. Residual levels of O2 present in packs can negatively affect product quality and subsequently, product shelf-life, especially for O2-sensitive foods/beverages. Therefore, the ability of O2 sensors to continuously monitor O2 levels present within food/beverage packages was considered commercially relevant in terms of identifying the consequences of residual O2 on product safety and quality over time. Research commenced with the development of a novel range of O2 sensors based on phosphorescent platinum and palladium octaethylporphyrin-ketones (OEPk) in nano-porous high density polyethylene (HDPE), polypropylene (PP) polytetrafluoroethylene (PTFE) polymer supports. Sensors were calibrated over a temperature range of -10°C to +40°C and deemed suitable for food and beverage packaging applications. This sensor technology was used and demonstrated itself effective in determining failures in packaging containment. This was clearly demonstrated in the packaging of cheese string products. The sensor technology was also assessed across a wide range of packaged products; beer, ready-to-eat salad products, bread and convenience-style, muscle-based processed food products. The O2 sensor technology performed extremely well within all packaging systems. The sensor technology adequately detected O2 levels in; beer bottles prior to and following pasteurisation, modified atmosphere (MA) packs of ready-to-eat salad packs as respiration progressed during product storage and MA packs of bread and convenience-style muscle-based products as mycological growth occurred in food packs over time in the presence and absence of ethanol emitters. The use of the technology, in conjunction with standard food quality assessment techniques, showed remarkable usefulness in determining the impact of actual levels of O2 on specific quality attributes. The O2 sensing probe was modified, miniaturised and automated to screen for the determination of total aerobic viable counts (TVC) in several fish species samples. The test showed good correlation with conventional TVC test (ISO:4833:2003), analytical performance and ruggedness with respect to variation of key assay parameters (probe concentration and pipetting volume). Overall, the respirometric fish TVC test was simple to use, possessed a dynamic microbial range (104-107 cfu/g sample), had an accuracy of +/- one log(cfu/g sample) and was rapid. Its ability to assess highly perishable products such as fish for total microbial growth in <12 hr demonstrates commercial potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The firm adhesion of flavouring particles onto crisp surfaces during coating processes is a major concern in the snack production industry. Detachment of flavouring powders from products during handling and production stages can lead to substantial financial losses for the industry, in terms of variable flavour performance and extended cleaning down time of fugitive particle build-up on process equipment. Understanding the adhesion strength of applied bulk particulates used for flavouring formulations will help analysts to evaluate the efficiency of coating processes and potentially enable them to assess the adhesion strength of newly formulated flavouring powder prior to commitment to full scale plant trials. A rapid prototype of a novel adhesion tester has been designed and constructed. The apparatus operates according to the principle of impact force acting on particles attached to the surface of the food substrate. The main component is a circular plate to which four sample holders are attached and which is subjected to vertical travel down a guide shaft. Several flavouring powders have been tested extensively. By plotting the detachment versus impact force, the difference obtained between adhesion strength of different flavouring powders (which is a strong function of particle size) has been discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability to monitor and evaluate the consequences of ongoing behaviors and coordinate behavioral adjustments seems to rely on networks including the anterior cingulate cortex (ACC) and phasic changes in dopamine activity. Activity (and presumably functional maturation) of the ACC may be indirectly measured using the error-related negativity (ERN), an event-related potential (ERP) component that is hypothesized to reflect activity of the automatic response monitoring system. To date, no studies have examined the measurement reliability of the ERN as a trait-like measure of response monitoring, its development in mid- and late- adolescence as well as its relation to risk-taking and empathic ability, two traits linked to dopaminergic and ACC activity. Utilizing a large sample of 15- and 18-year-old males, the present study examined the test-retest reliability of the ERN, age-related changes in the ERN and other components of the ERP associated with error monitoring (the Pe and CRN), and the relations of the error-related ERP components to personality traits of risk propensity and empathy. Results indicated good test-retest reliability of the ERN providing important validation of the ERN as a stable and possibly trait-like electrophysiological correlate of performance monitoring. Ofthe three components, only the ERN was of greater amplitude for the older adolescents suggesting that its ACC network is functionally late to mature, due to either structural or neurochemical changes with age. Finally, the ERN was smaller for those with high risk propensity and low empathy, while other components associated with error monitoring were not, which suggests that poor ACe function may be associated with the desire to engage in risky behaviors and the ERN may be influenced by the extent of individuals' concern with the outcome of events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cercal hairs represent in cricket a wind sensitive escape system, able to detect the airflow generated from predating species. These sensors have been studied as a biomimetic concept to allow the development of MEMS for biomedical use. In particular, the behaviour of the hairs, including airflow response, resonant frequency and damping, has been investigated up to a frequency of 20 kHz. The microscopic nature of the hairs, the complex vibrations of excited hairs and the high damping of the system suggested that the use of Laser Doppler vibrometry could possibly improve the test performance. Two types of tests were performed: in the first case the hairs were indirectly excited using the signal obtained from a vibrating aluminium plate, whilst in the second case the hairs were directly excited using a white noise chirp. The results from the first experiment indicated that the hairs move in-phase with the exciting signal up to frequencies in the order of 10 kHz, responding to the vibration modes of the plate with a signal attenuation of 12 to 20 dB. The chirp experiment revealed the presence of rotational resonant modes at 6850 and 11300 Hz. No clear effect of hair length was perceivable on the vibration response of the filiform sensors. The obtained results proved promising to support the mechanical and vibration characterisation of the hairs and suggest that scanning Laser vibrometry can be used extensively on highly dampened biological materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement is reported at 4 deg K (and blocked transmission below 10-5) of PbTe/ZnS thin-film filters deposited on Ge substrates. The reduced carrier-absorption which is obtained by cooling these PbTe films is found to accord with simple theory. Advantage for various high-performance multilayers by cooling is significant at the longer wavelengths, and has been verified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of increasing salinity and freezing stress singly and in combination on a range of chlorophyll fluorescence parameters in foliar tissue of six Crataegus genotypes was examined. In general, increased stress reduced fluorescence values and absorption, trapping and electron transport energy fluxes per leaf reaction center and cross section, with decreased sigmoidicity of OJIP curves as a measure of the plastoquinone pool, reflecting decreased energy fluxes. Based on percentage reduction in a performance index from controls compared to stress-treated values, plants were ranked in order of tolerant > intermediate > sensitive. Use of this PIp ranking criteria enabled the distinguishing of marked differences in foliar salt/freezing hardiness between the Crataegus species used. Interpretation of the photochemical data showed that salinity and freezing affects both the acceptor and donor side of Photosystem II, while OJIP observations provided information regarding structural and functional changes in the leaf photosynthetic apparatus of the test species. It is concluded that chlorophyll fluorescence offers a rapid screening technique for assessing foliar salinity and freezing tolerance of woody perennials

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors identified several specific problems with the measurement of achievement goals in the current literature and illustrated these problems, focusing primarily on A. J. Elliot and H. A. McGregor's (2001) Achievement Goal Questionnaire (AGQ). They attended to these problems by creating the AGQ-Revised and conducting a study that examined the measure's structural validity and predictive utility with 229 (76 male, 150 female, 3 unspecified) undergraduates. The hypothesized factor and dimensional structures of the measure were confirmed and shown to be superior to a host of alternatives. The predictions were nearly uniformly supported with regard to both the antecedents (need for achievement and fear of failure) and consequences (intrinsic motivation and exam performance) of the 4 achievement goals. In discussing their work, the authors highlight the importance and value of additional precision in the area of achievement goal measurement. (PsycINFO Database Record (c) 2012 APA, all rights reserved)(journal abstract)