855 resultados para Measurement in Bacteriology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is little agreement as to the most appropriate thermometer, the anatomical site to carry out temperature measurement in children with cancer, or the type of thermometer preferred by the patients. The authors carried out this study to assess temperature measurement in children with cancer who were admitted for febrile episodes. The body temperatures of children with cancer who were admitted consecutively between January and October 2005 to the paediatric department because of febrile episodes were measured on admission and over the next 24–36 hours using an electronic thermometer sublingually as the standard reference site. These measurements were compared with those obtained with two ear-based thermometers, a forehead thermometer, and from the axilla (representing current practice). The parents were asked about the type of thermometer they used at home and the children were asked about the type of thermometer they preferred. There were 34 admissions during this period, of which 19 (56%) were confirmed as febrile. Altogether, 108 sets of temperature measurements were obtained, producing a total of 540 measurements from these admissions. Measurements with the two ear-based thermometers in febrile children achieved higher sensitivity than that with axillary and the forehead measurements. The ear-based thermometer was the most common type used at home while the forehead thermometer was the one preferred by the children. In conclusion, ear-based temperature measurements in febrile children were more accurate than axillary and forehead temperature measurements. The current practice of axillary temperature measurement needs to be re-considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The harsh environment presented by engines, particularly in the exhaust systems, often necessitates the use of robust and therefore low bandwidth temperature sensors. Consequently, high frequencies are attenuated in the output. One technique for addressing this problem involves measuring the gas temperature using two sensors with different time-constants and mathematically reconstructing the true gas temperature from the resulting signals. Such a technique has been applied in gas turbine, rocket motor and combustion research. A new reconstruction technique based on difference equations has been developed and its effectiveness proven theoretically. The algorithms have been successfully tested and proven on experimental data from a rig that produces cyclic temperature variations. These tests highlighted that the separation of the thermocouple junctions must be very small to ensure that both sensors are subjected to the same gas temperatures. Exhaust gas temperatures were recorded by an array of thermocouples during transient operation of a high performance two-stroke engine. The results show that the increase in bandwidth arising from the dual sensor technique allowed accurate measurement of exhaust gas temperature with relatively robust thermocouples. Finally, an array of very fine thermocouples (12.5 - 50 microns) was used to measure the in-cycle temperature variation in the exhaust.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As awareness of the limitations of relying solely on income to measure poverty has become more widespread, attention has been increasingly focused on multi-dimensional approaches, to the point where the EU has adopted a multidimensional poverty and social exclusion target for 2020. The rationale advanced is that the computation of a multidimensional poverty index is an effective way of communicating in a political environment, and a necessary tool in order to monitor 27 different national situations. By contrast with the rather ad hoc way in which the EU 2020 poverty target has been framed and rationalised, the adjusted head count ratio applied here has a number of desirable axiomatic properties. It constitutes a significant improvement on union and intersection approaches and allows for the decomposition of multidimensional poverty in terms of dimensions of deprivation and socio-economic attributes. Since understanding poverty as multidimensional does not necessarily require constructing a multidimensional poverty index, on the basis of our analysis we provide a more general consideration of the value of developing a multidimensional index of poverty for the European Union.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE:

To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.

DESIGN:

Clinic-based validation and interobserver reliability trial.

PARTICIPANTS:

Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.

INTERVENTION:

In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).

MAIN OUTCOME MEASURES:

Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.

RESULTS:

In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).

CONCLUSION:

Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of computer vision based quality control has been slowly but steadily gaining importance mainly due to its speed in achieving results and also greatly due to its non- destnictive nature of testing. Besides, in food applications it also does not contribute to contamination. However, computer vision applications in quality control needs the application of an appropriate software for image analysis. Eventhough computer vision based quality control has several advantages, its application has limitations as to the type of work to be done, particularly so in the food industries. Selective applications, however, can be highly advantageous and very accurate.Computer vision based image analysis could be used in morphometric measurements of fish with the same accuracy as the existing conventional method. The method is non-destructive and non-contaminating thus providing anadvantage in seafood processing.The images could be stored in archives and retrieved at anytime to carry out morphometric studies for biologists.Computer vision and subsequent image analysis could be used in measurements of various food products to assess uniformity of size. One product namely cutlet and product ingredients namely coating materials such as bread crumbs and rava were selected for the study. Computer vision based image analysis was used in the measurements of length, width and area of cutlets. Also the width of coating materials like bread crumbs was measured.Computer imaging and subsequent image analysis can be very effectively used in quality evaluations of product ingredients in food processing. Measurement of width of coating materials could establish uniformity of particles or the lack of it. The application of image analysis in bacteriological work was also done