976 resultados para Manipulação da coluna cervical
Resumo:
To evaluate pathologic features with implications on surgical radicality in women treated with radical hysterectomy and pelvic lymphadenectomy for cervical cancer stage IA1 with lymph vascular space invasion (LVSI) and stage IA2 by correlating findings in conization and hysterectomy specimens. Women with cervical cancer stage IA1 with LVSI and stage IA2 diagnosed by loop electrosurgical excisional procedure or cold knife conization were treated with radical hysterectomy and pelvic lymphadenectomy from January 1999 to December 2011 in 2 institutions. Fifty patients were enrolled: 40 with stage IA2 and 10 with stage IA1 with LVSI. Median age was 43 (30-67) years. All patients underwent cervical conization for diagnosis (45 loop electrosurgical excisional procedure, 5 cold knife). Lymph vascular space invasion was detected in 15 patients (30%). Two patients had positive pelvic nodes. No parametrial involvement was detected in the entire cohort. Positive margins were present in 35 patients, and residual disease was detected in 22 patients (44%). Positive margins predicted residual disease at radical hysterectomy (P = 0.02). Medium follow-up time was 51 months. One patient developed a pelvic recurrence, and there were no disease-related deaths. Patients with positive margins in cone biopsy specimens have an increased risk of residual disease at radical hysterectomy and require careful evaluation before conservative surgery. Pelvic lymph node evaluation is essential because lymph node metastasis may occur even in early stages. The lack of parametrial invasion in this study reinforces the knowledge that the select group of patients with microinvasive cervical carcinoma stages IA1 LVSI and stage IA2 have a very low risk of parametrial infiltration. Less radical surgery can be carefully considered for these patients.
Resumo:
To evaluate p16(INK) (4a) immunoexpression in CIN1 lesions looking for differences between cases that progress to CIN2/3 maintain CIN1 diagnosis, or spontaneously regress. Seventy-four CIN1 biopsies were studied. In the follow-up, a second biopsy was performed and 28.7% showed no lesion (regression), 37.9% maintained CIN1, and 33.4% progressed to CIN2/3. Immunostaining for p16(INK) (4a) was performed in the first biopsy and it was considered positive when there was strong and diffuse staining of the basal and parabasal layers. Pearson's chi-square was used to compare the groups (p ≤ 0.05). The age of the patients was similar. There was no significant difference in p16(INK) (4a) immunoexpression in the groups, however, statistical analyses showed a significant association when only the progression and regression groups were compared (p = 0.042). Considering p16(INK) (4a) positivity and the progression to CIN2/3, the sensitivity, specificity, positive, and negative predictive values in our cohort were 45%, 75%, 47%, and 94%, respectively. We emphasize that CIN1 with p16(INK) (4a) staining was associated with lesion progression, but the sensitivity was not high. However, the negative predictive value was more reliable (94%) and p16(INK) (4a) may represent a useful biomarker that can identify CIN1 lesions that need particular attention, complementing morphology.
Resumo:
179
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
A biologia molecular tem fornecido as ferramentas básicas para os geneticistas se aprofundarem nos mecanismos moleculares que influem na variação das doenças. Deve-se destacar a responsabilidade científica e moral dos pesquisadores, uma vez que os cientistas devem imaginar as consequências morais da aplicação comercial de testes genéticos, já que esse fato envolve não só o indivíduo e suas famílias, mas toda a população. Além de ser preciso, também, fazer uma reflexão sobre como essas informações do genoma humano serão utilizadas, para o bem ou mal. O objetivo desta revisão foi trazer à luz do conhecimento dados sobre características éticas da aplicação da biologia molecular, relacionando-a com os direitos do ser humano. Após análise bibliográfica, pôde-se observar que o Projeto Genoma Humano gerou várias possibilidades, como identificação de genes associados a doenças com propriedades sinergísticas, mas modificando às vezes comportamentos ao intervir geneticamente no ser humano, trazendo benefícios ou malefícios sociais. O grande desafio é decidir o que a humanidade pretende em relação a este gigantesco salto.
Resumo:
This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (µm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 ± 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 ± 48.31), followed by EndoFlare instruments (68.20 ± 42.44), Gattes Glidden drills (68.90 ± 42.46) and ProTaper files (77.40 ± 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.
Resumo:
The aim of this study was to compare different treatments for dentin hypersensitivity in a 6-month follow-up. One hundred and one teeth exhibiting non carious cervical lesions were selected. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment (baseline), immediately after topical treatment, after 1 week, 1, 3 and 6 months. Teeth were randomly assigned to five groups (n = 20): G1: Gluma Desensitizer (GD); G2: Seal&Protect (SP); G3: Oxa-gel (OG); G4: Fluoride (F); G5: Low intensity laser-LILT (660 nm/3.8 J/cm²/15 mW). Analysis was based on the non-parametric Kruskal-Wallis test that demonstrated statistical differences immediately after the treatment (p = 0.0165). To observe the individual effects of each treatment, data was submitted to Friedman test. It was observed that GD and SP showed immediate effect after application. Reduction in the pain level throughout the six-month follow-up was also observed. In contrast, LILT presented a gradual reduction of hypersensitivity. OG and F showed effects as of the first and third month respectively. It can be concluded that, after the 6-month clinical evaluation, all therapies showed lower VAS sensitivity values compared with baseline, independently of their different modes of action.
Resumo:
PURPOSE: In this case report, the clinical performance of a microhybrid resin composite placed with or without a flowable resin composite was compared, over a 48-month period. CASE DESCRIPTION: The patient of this case report presented 2 pairs of equivalent cervical abfraction lesions, under occlusion. Four restorations were placed in teeth 34, 35, 44 and 45. The restorations were divided into groups (Single Bond + Filtek-Flow + Filtek Z250 or Single Bond + Filtek Z250) and the materials were applied according to the manufactures instructions. Two previously calibrated operators placed the restorations and two other independent examiners evaluated the restorations at baseline and after 48 months, according to the USPHS criteria and modified criteria for color match. CONCLUSION: After 48 months of evaluation the lesions restored with Filtek-Flow as a liner under Filtek Z250 did not show better clinical performance than the restorations without Filtek-Flow. All restorations showed a trend toward dark yellowing after 48 months.
Resumo:
OBJETIVO: avaliar a morfometria da pars da segunda vértebra cervical, verificar as variações existentes e predizer sua segurança para a colocação de parafusos por meio de uma abordagem cervical posterior. MÉTODOS: 58 vértebras foram obtidas para estudo anatômico (116 pars de C2) e foram medidas a altura e largura da pars, além do comprimento eixo-pedículo, largura e comprimento do pedículo, angulação sagital e medial. Todas as medidas foram separadas quanto aos seus lados direito e esquerdo; foi realizado o cálculo da média, variação, desvio padrão e a médica foi comparada com os estudos prévios. RESULTADOS: a largura média da pars de C2 foi de 9,5 mm; a altura, 9,5 mm; não houve diferença significativa entre os lados esquerdo e direito. O comprimento médio do pedículo foi de 10,5 mm; a medida média encontrada para o comprimento eixo-pedículo foi de 24,9 mm; a largura do pedículo foi de 2,8 mm. A angulação sagital encontrada foi de 19,6º e a horizontal foi de 28,5º. CONCLUSÕES: este estudo demonstra a viabilidade para a colocação de parafuso na pars de C2 em uma população caucasiana, destacando-se, porém, a grande variabilidade anatômica encontrada nas referidas medidas.