958 resultados para Intra-examiner reproducibility


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the validity and the inter- and intra-examiner reliability of panoramic-radiograph-driven findings of different maxillary sinus anatomic variations and pathologies, which had initially been prediagnosed by cone beam computed tomography (CBCT). Methods: After pairs of two-dimensional (2D) panoramic and three-dimensional (3D) CBCT images of patients having received treatment at the outpatient department had been screened, the predefinition of 54 selected maxillary sinus conditions was initially performed on CBCT images by two blinded consultants individually using a questionnaire that defined ten different clinically relevant findings. Using the identic questionnaire, these consultants performed the evaluation of the panoramic radiographs at a later time point. The results were analyzed for inter-imaging differences in the evaluation of the maxillary sinus between 2D and 3D imaging methods. Additionally, two resident groups (first year and last year of training) performed two diagnostic runs of the panoramic radiographs and results were analyzed for inter- and intra-observer reliability. Results: There is a moderate risk for false diagnosis of findings of the maxillary sinus if only panoramic radiography is used. Based on the ten predefined conditions, solely maxillary bone cysts penetrating into the sinus were frequently detected differently comparing 2D to 3D diagnostics. Additionally, on panoramic radiographs, the inter-observer comparison demonstrated that basal septa were significantly often rated differently and the intra-observer comparison showed a significant lack in reliability in detecting maxillary bone cysts penetrating into the sinus. Conclusions: Panoramic radiography provides the most information on the maxillary sinus, and it may be an adequate imaging method. However, particular findings of the maxillary sinus in panoramic imaging may be based on a rather examiner-dependent assessment. Therefore, a persistent and precise evaluation of specific conditions of the maxillary sinus may only be possible using CBCT because it provides additional information compared to panoramic radiography. This might be relevant for consecutive surgical procedures; consequently, we recommend CBCT if a precise preoperative evaluation is mandatory. However, higher radiation dose and costs of 3D imaging need to be considered. Keywords: Panoramic radiography; Cone beam computed tomography; Maxillary sinus; Inter-imaging method differences; Inter-examiner reliability; Intra-examiner reliability

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A expansão rápida da maxila assistida cirurgicamente (ERMAC) é um dos procedimentos de escolha para correção da deficiência transversal em pacientes adultos. Este estudo avaliou as alterações produzidas nos arcos dentais superiores e inferiores de 18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos submetidos à ERMAC. Para cada paciente foram preparados três modelos de gesso, que foram digitalizados por meio do Scanner 3D, obtidos em diferentes fases: inicial, antes do procedimento operatório (T1); três meses pós-expansão (T2); seis meses pós-expansão (T3). Foram avaliadas as distâncias transversais do arcos dentários superior e inferior, a inclinação dentária dos dentes posteriores superiores, a altura da coroa clínica dos dentes posteriores do arco superior e foi observado se havia correlação entre a quantidade de inclinação dentária com o desenvolvimento de recessões gengivais. Para análise dos resultados foram utilizados a análise de Variância, o Teste de Tukey e o Teste de Correlação de Pearson, sendo que para a análise do erro sistemático intra-examinador foi utilizado o teste t pareado e para determinação do erro casual utilizou-se o cálculo do erro de Dahlberg. Com base na metodologia utilizada e nos resultados obtidos, pode-se concluir que: 1. com relação as alterações produzidas no sentido transversal do arco superior, obteve-se um aumento em todas as variáveis de T1 para T2 e uma manutenção dos valores em todas as variáveis de T2 para T3 demonstrando efetividade e estabilidade do procedimento; 2. no arco inferior não houve alterações transversais estatisticamente significantes, com exceção dos primeiros molares; 3. com relação às inclinações dentárias, observou-se um aumento desta de T1 para T2 em todos os dentes, porém, com significância estatística apenas para segundo molar e primeiro e segundo pré-molar do lado direito e primeiro molar e segundo pré-molar do lado esquerdo.; 4. a ERMAC não acarretou o desenvolvimento de recessões gengivais em nenhum dos tempos; 5. não houve correlação entre a quantidade de inclinação dentária e o desenvolvimento de recessões gengivais.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A expansão rápida da maxila assistida cirurgicamente (ERMAC) é um dos procedimentos de escolha para correção da deficiência transversal em pacientes adultos. Este estudo avaliou as alterações produzidas nos arcos dentais superiores e inferiores de 18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos submetidos à ERMAC. Para cada paciente foram preparados três modelos de gesso, que foram digitalizados por meio do Scanner 3D, obtidos em diferentes fases: inicial, antes do procedimento operatório (T1); três meses pós-expansão (T2); seis meses pós-expansão (T3). Foram avaliadas as distâncias transversais do arcos dentários superior e inferior, a inclinação dentária dos dentes posteriores superiores, a altura da coroa clínica dos dentes posteriores do arco superior e foi observado se havia correlação entre a quantidade de inclinação dentária com o desenvolvimento de recessões gengivais. Para análise dos resultados foram utilizados a análise de Variância, o Teste de Tukey e o Teste de Correlação de Pearson, sendo que para a análise do erro sistemático intra-examinador foi utilizado o teste t pareado e para determinação do erro casual utilizou-se o cálculo do erro de Dahlberg. Com base na metodologia utilizada e nos resultados obtidos, pode-se concluir que: 1. com relação as alterações produzidas no sentido transversal do arco superior, obteve-se um aumento em todas as variáveis de T1 para T2 e uma manutenção dos valores em todas as variáveis de T2 para T3 demonstrando efetividade e estabilidade do procedimento; 2. no arco inferior não houve alterações transversais estatisticamente significantes, com exceção dos primeiros molares; 3. com relação às inclinações dentárias, observou-se um aumento desta de T1 para T2 em todos os dentes, porém, com significância estatística apenas para segundo molar e primeiro e segundo pré-molar do lado direito e primeiro molar e segundo pré-molar do lado esquerdo.; 4. a ERMAC não acarretou o desenvolvimento de recessões gengivais em nenhum dos tempos; 5. não houve correlação entre a quantidade de inclinação dentária e o desenvolvimento de recessões gengivais.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To establish a simple method to quantify muscle/fat constituents in cervical muscles of asymptomatic women using magnetic resonance imaging (MRI), and to determine whether there is an age effect within a defined age range. MATERIALS AND METHODS: MRI of the upper cervical spine was performed for 42 asymptomatic women aged 18-45 years. The muscle and fat signal intensities on axial spin echo T1-weighted images were quantitatively classified by taking a ratio of the pixel intensity profiles of muscle against those of intermuscular fat for the rectus capitis posterior major and minor and inferior obliquus capitis muscles bilaterally. Inter- and intra-examiner agreement was scrutinized. RESULTS: The average relative values of fat within the upper cervical musculature compared with intermuscular fat indicated that there were only slight variations in indices between the three sets of muscles. There was no significant correlation between age and fat indices. There were significant differences for the relative fat within the muscle compared with intermuscular fat and body mass index for the right rectus capitis posterior major and right and left inferior obliquus capitis muscles (p = 0.032). Intraclass correlation coefficients for intraobserver agreement ranged from 0.94 to 0.98. Inter-rater agreement of the measurements ranged from 0.75 to 0.97. CONCLUSION: A quantitative measure of muscle/fat constituents has been developed, and results of this study indicate that relative fatty infiltration is not a feature of age in the upper cervical extensor muscles of women aged 18-45 years. (C) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A expansão rápida da maxila assistida cirurgicamente (ERMAC) é um dos procedimentos de escolha para correção da deficiência transversal em pacientes adultos. Este estudo avaliou as alterações produzidas nos arcos dentais superiores e inferiores de 18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos submetidos à ERMAC. Para cada paciente foram preparados três modelos de gesso, que foram digitalizados por meio do Scanner 3D, obtidos em diferentes fases: inicial, antes do procedimento operatório (T1); três meses pós-expansão (T2); seis meses pós-expansão (T3). Foram avaliadas as distâncias transversais do arcos dentários superior e inferior, a inclinação dentária dos dentes posteriores superiores, a altura da coroa clínica dos dentes posteriores do arco superior e foi observado se havia correlação entre a quantidade de inclinação dentária com o desenvolvimento de recessões gengivais. Para análise dos resultados foram utilizados a análise de Variância, o Teste de Tukey e o Teste de Correlação de Pearson, sendo que para a análise do erro sistemático intra-examinador foi utilizado o teste t pareado e para determinação do erro casual utilizou-se o cálculo do erro de Dahlberg. Com base na metodologia utilizada e nos resultados obtidos, pode-se concluir que: 1. com relação as alterações produzidas no sentido transversal do arco superior, obteve-se um aumento em todas as variáveis de T1 para T2 e uma manutenção dos valores em todas as variáveis de T2 para T3 demonstrando efetividade e estabilidade do procedimento; 2. no arco inferior não houve alterações transversais estatisticamente significantes, com exceção dos primeiros molares; 3. com relação às inclinações dentárias, observou-se um aumento desta de T1 para T2 em todos os dentes, porém, com significância estatística apenas para segundo molar e primeiro e segundo pré-molar do lado direito e primeiro molar e segundo pré-molar do lado esquerdo.; 4. a ERMAC não acarretou o desenvolvimento de recessões gengivais em nenhum dos tempos; 5. não houve correlação entre a quantidade de inclinação dentária e o desenvolvimento de recessões gengivais.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cephalometric analysis is the mensuration of linear and angular measures through demarcation points as distances and lines on teleradiography, and is considered of fundamental importance for diagnosis and orthodontic planning. In this manner, the objective of this research was to compare cephalometric measurements obtained by dentists and radiologists from the analysis of the same radiograph, in a computerized cephalometric analysis program. All research participants marked 18 cephalometric points on a 14-inch notebook computer, as directed by the program itself (Radiocef 2®). From there, they generated 14 cephalometric parameters including skeletal, dental-skeletal, dental and soft tissue. In order to verify the intra-examiner agreement, 10 professionals from each group repeated the marking of the points with a minimum interval of eight days between the two markings. The intra-group variability was calculated based on the coefficients of variation (CV). The comparison between groups was performed using the Student t-test for normally distributed variables, and using the Mann-Whitney test for those with non-normal distribution. In the group of orthodontists, the measurements of Pog and 1-NB, SL, S-Ls Line, S-Li Line and 1.NB showed high internal variability. In the group of radiologists, the same occurred with the values of Pog and 1-NB, S-Ls Line, S-Li Line and 1.NA. In the comparison between groups, all the analyzed linear values and two angular values showed statistically significant differences between radiologists and dentists (p <0.05). According to the results, the interexaminer error in cephalometric analysis requires more attention, but does not come from a specific class of specialists, being either dentists or radiologists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Global Network for the Molecular Surveillance of Tuberculosis 2010: A. Miranda (Tuberculosis Laboratory of the National Institute of Health, Porto, Portugal)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

International audience

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT: Background: The Caries Assessment Spectrum and Treatment (CAST) is a new epidemiological instrument for detection and treatment of dental caries. Worldwide, the WHO criterion constitutes the epidemiological tool most commonly used for caries detection. The objective of the present study is to determine the levels of similarity and difference between the CAST instrument and WHO criterion on the basis of caries prevalence, dmf/DMF counts, examination time and reporting of results. Methods: An epidemiological survey was carried out in Brazil among 6-11-year-old schoolchildren. Time of examinations was recorded. dmft, dmfs, DMFT and DMFS counts and dental caries prevalence were obtained according to the WHO criterion and the CAST instrument, as well the correlation coefficient between the two instruments. Results: Four hundred nineteen children were examined. dmft and dmfs counts were 1.92 and 5.31 (CAST), 1.99 and 5.34 (WHO) with correlation coefficients (r) of 0.95 and 0.93, respectively. DMFT and DMFS counts were 0.20 and 0.33 (CAST), 0.19 and 0.30 (WHO), with r = 0.78 and r=0.72, respectively. Kappa coefficient values for intra-examiner consistency were CAST = 0.91-0.92; WHO = 0.95-0.96 and those for inter-examiner consistency were CAST = 0.90-0.96; WHO = 0.94-1.00. Mean time spent on applying CAST and WHO were 66.3 and 64.7 sec, respectively p = 0.26. The prevalence of dental caries using CAST (codes 2, 5-8) and the WHO criterion for the primary dentition were 63.0% and 65.9%, respectively, and for the permanent dentition they were 12.7% and 12.8%, respectively. Conclusions: The CAST instrument provided similar prevalence of dental caries values and dmf/DMF counts as the WHO criterion in this age group. Time spent on examining children was identical for both caries assessment methods. Presentation of results from use of the CAST instrument, in comparison to WHO criterion, allowed a more detailed reporting of stages of dental caries, which will be useful for oral health planners.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to verify the drying effect on the reproducibility of DIAGNOdent (Dd) devices to detect caries-like lesions. Three areas were created in each of the 34 bovine incisors: sound (S), demineralized (DE) and remineralized (RE). One examiner measured each area with two Dd devices (denominated X and Y), twice under humid, and twice under dry condition. Intra-rater agreement according each device and inter-device agreement were estimated by kappa statistics (k). Intra-rater agreement for device Y was substantial under humid (k DE=0.68 and k RE+S=0.68) and dry condition (k DE=0.64 and k RE+S=0.67). For device X, it was substantial under humid condition (k DE=0.57 and k RE+S=0.49), and it was almost perfect after air drying (k DE=1.0 and kRE+S=1.0). Inter-device agreement was slight (k =0.17) under humid condition, and it was substantial under dry condition (k =0.62). As reproducibility increased under dry condition, drying is advised to detect caries-like lesions on free smooth surfaces when different devices are used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this in vitro study was to assess the influence of varying examiner's clinical experience on the reproducibility and accuracy of radiographic examination for occlusal caries detection. Standardized bitewing radiographs were obtained from 166 permanent molars. Radiographic examination was performed by final-year dental students from two universities (A, n=5; B, n=5) and by dentists with 5 to 7 years of experience who work in two different countries (C, n=5; D, n=5). All examinations were repeated after 1-week interval. The teeth were histologically prepared and assessed for caries extension. For intraexaminer reproducibility, the unweighted kappa values were: A (0.11-0.40), B (0.12-0.33), C (0.47-0.58), and D (0.42-0.71). Interexaminer reproducibility statistics were computed based on means +/- SD of unweighted kappa values: A (0.07 +/- 0.05), B (0.12 +/- 0.09), C (0.24 +/- 0.08), and D (0.33 +/- 0.10). Sensitivity, specificity, and accuracy were calculated at D(1) and D(3) thresholds and compared by performing McNemar test (p=0.05). D(1) sensitivity ranged between 0.29 and 0.75 and specificity between 0.24 and 0.85. D(3) specificity was moderate to high (between 0.62 and 0.95) for all groups, with statistically significant difference between the dentists groups (C and D). Sensitivity was low to moderate (between 0.21 and 0.57) with statistically significant difference for groups B and D. Accuracy was similar for all groups (0.55). Spearman's correlations were: A (0.12), B (0.24), C (0.30), and D (0.38). In conclusion, the reproducibility of radiographic examination was influenced by the examiner's clinical experience, training, and dental education as well as the accuracy in detecting occlusal caries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to verify the drying effect on the reproducibility of DIAGNOdent (Dd) devices to detect caries-like lesions. Three areas were created in each of the 34 bovine incisors: sound (S), demineralized (DE) and remineralized (RE). One examiner measured each area with two Dd devices (denominated X and Y), twice under humid, and twice under dry condition. Intra-rater agreement according each device and inter-device agreement were estimated by kappa statistics (κ). Intra-rater agreement for device Y was substantial under humid (κ DE=0.68 and κ RE+S=0.68) and dry condition (κ DE=0.64 and κ RE+S=0.67). For device X, it was substantial under humid condition (κ DE=0.57 and κ RE+S=0.49), and it was almost perfect after air drying (κ DE=1.0 and κRE+S=1.0). Inter-device agreement was slight (κ =0.17) under humid condition, and it was substantial under dry condition (κ =0.62). As reproducibility increased under dry condition, drying is advised to detect caries-like lesions on free smooth surfaces when different devices are used.