992 resultados para IN-VITRO ASSESSMENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doubled haploid onion (Allium cepa L.) plants allow the production of completely homozygous lines for a later production of hybrids. The haploid plants are normally produced using in vitro gynogenesis. The obtained haploid plantlets must be treated with different agents for doubling chromosomes. It is necessary to adjust the concentration and the length of treatment of the doubling agent. In this case, the effect of 250 and 500 mg.L-1 colchicine and 15.2; 30 and 60 mg.L- 1 amiprophos-methyl during 24 and 48 h was assessed over the rate of onion haploid plantlets chromosome doubling. The best duplication treatment was 250 mg.L-1 colchicine for 48 h, which yielded 100% of doubled haploid plants. On the other hand, a positive correlation resulted from the ploidy level and stomatal size, and a negative correlation between the level of ploidy and stomatal density. Significant differences between the stomatal length, width and density in haploid and doubled haploid plantlets were observed. An economical and quick method to test ploidy level in onion plantlets is proposed through the measurement of stomatal size and density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liver-on-chip systems are widely seen as having the potential to replace animal testing for long-term liver toxicity assessments. However, such systems necessitate solutions, such as electrochemical microsensors, to provide information about the cells exposed to chemical compounds in a confined space. This study describes the development of microsensors for the detection of alanine-aminotransferase (ALT), an intracellular enzyme found in hepatocytes, for monitoring the viability of in-vitro hepatic cell cultures. The electrochemical sensors were developed by using screen printed electrodes functionalized by drop-casting. These technologies are intended to produce disposable and low-cost sensors that can easily be exchanged once their performance is degraded. The sensors are capable of measuring ALT in a microfluidic environment through the detection of changes in glutamate concentration. The microsensors were found to be stable for more than 60 days and were successfully tested using hepatocellular lysates to assess their capability to quantify ALT activity in a hepatic cell culture. These results open the way to their integration in liver bioreactors to assess hepatocellular toxicity in-vitro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Aims: We have optimized the isolated perfused mouse kidney (IPMK) model for studying renal vascular and tubular function in vitro using 24-28 g C57BL6J mice; the wild type controls for many transgenic mice. Methods and Results: Buffer composition was optimized for bovine serum albumin concentration (BSA). The effect of adding erythrocytes on renal function and morphology was assessed. Autoregulation was investigated during stepped increases in perfusion pressure. Perfusion for 60 min at 90-110 mmHg with Krebs bicarbonate buffer containing 5.5% BSA, and amino acids produced functional parameters within the in vivo range. Erythrocytes increased renal vascular resistance (3.8 +/- 0.2 vs 2.4 +/- 0.1 mL/min.mmHg, P < 0.05), enhanced sodium reabsorption (FENa = 0.3 +/- 0.08 vs 1.5 +/- 0.7%, P < 0.05), produced equivalent glomerular filtration rates (GFR; 364 +/- 38 vs 400 +/- 9 muL/min per gkw) and reduced distal tubular cell injury in the inner stripe (5.8 +/- 1.7 vs 23.7 +/- 3.1%, P < 0.001) compared to cell free perfusion. The IPMK was responsive to vasoconstrictor (angiotensin II, EC50 100 pM) and vasodilator (methacholine, EC50 75 nM) mediators and showed partial autoregulation of perfusate flow under control conditions over 65-85 mmHg; autoregulatory index (ARI) of 0.66 +/- 0.11. Angiotensin II (100 pM) extended this range (to 65-120 mmHg) and enhanced efficiency (ARI 0.21 +/- 0.02, P < 0.05). Angiotensin II facilitation was antagonized by methacholine (ARI 0.76 +/- 0.08) and papaverine (ARI 0.91 +/- 0.13). Conclusion: The IPMK model is useful for studying renal physiology and pathophysiology without systemic neurohormonal influences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three human astroglioma lines U251-MG, U373-MG and CCF-STTG1 have been evaluated further as possible models for astrocytotoxicity (GFAP and IL-6 release). The effects of bacterial lipopolysaccharide, chloroquine diphosphate and acrylamide were studied on GFAP expression and LPS, chloroquine diphosphate, ethanol, trimethyltin chloride (TMTC) and acrylamide were examined on interleukin-6 (IL-6) release in the U373-MG line only. At 4-h LIPS elevated GFAP (17.0±5.0% P < 0.05) above control in the U251-MG cell line only. Chloroquine diphosphate over 4 h in the U251-MG line resulted in an increase in GFAP-IR to 20.3 ±4.2% and 21.1 ± 4.1 % above control levels 0.1 µM (P< 0.05) and 1 µM (P< 0.05) respectively. CQD was associated with decreases in MTT turnover, particularly after 24 h incubation. With the U373-MG line, LPS (0.5 µg/ml) increased IL-6 expression 640% above control (P < 0.001), whilst chloroquine diphosphate (100 µM), ethanol (10mM) and TMTC chloride (1 µM) also increased IL-6. It is possible that batteries of astrocytic human glioma cell lines may be applicable to the sensitive evaluation of toxicants on astrogliotic expression markers such as GFAP and IL-6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing useof nanomaterials in consumer products and biomedical applications creates the possibilities of intentional/unintentional exposure to humans and the environment. Beyond the physiological limit, the nanomaterialexposure to humans can induce toxicity. It is difficult to define toxicity of nanoparticles on humans as it varies by nanomaterialcomposition, size, surface properties and the target organ/cell line. Traditional tests for nanomaterialtoxicity assessment are mostly based on bulk-colorimetric assays. In many studies, nanomaterials have found to interfere with assay-dye to produce false results and usually require several hours or days to collect results. Therefore, there is a clear need for alternative tools that can provide accurate, rapid, and sensitive measure of initial nanomaterialscreening. Recent advancement in single cell studies has suggested discovering cell properties not found earlier in traditional bulk assays. A complex phenomenon, like nanotoxicity, may become clearer when studied at the single cell level, including with small colonies of cells. Advances in lab-on-a-chip techniques have played a significant role in drug discoveries and biosensor applications, however, rarely explored for nanomaterialtoxicity assessment. We presented such cell-integrated chip-based approach that provided quantitative and rapid response of cellhealth, through electrochemical measurements. Moreover, the novel design of the device presented in this study was capable of capturing and analyzing the cells at a single cell and small cell-population level. We examined the change in exocytosis (i.e. neurotransmitterrelease) properties of a single PC12 cell, when exposed to CuOand TiO2 nanoparticles. We found both nanomaterials to interfere with the cell exocytosis function. We also studied the whole-cell response of a single-cell and a small cell-population simultaneously in real-time for the first time. The presented study can be a reference to the future research in the direction of nanotoxicity assessment to develop miniature, simple, and cost-effective tool for fast, quantitative measurements at high throughput level. The designed lab-on-a-chip device and measurement techniques utilized in the present work can be applied for the assessment of othernanoparticles' toxicity, as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - Milk is considered a complete food from the nutritional point of view. Milk can be exposed to various types of contamination, such as mycotoxins. These metabolites are naturally occurring toxic compounds produced by fungi. Several studies on milk samples have reported the presence of aflatoxin B1 (AFB1) and M1 (AFM1), due to the high incidence in samples intended for human consumption, carcinogenicity proven AFB1 and resistance of the contaminants to the process of digestion, making those available for intestinal absorption. Considering these aspects, the objective of this study was to evaluate the genotoxicity of milk samples contaminated by AFB1 and AFM1 before and after the action of lactic acid bacteria using Caco-2 intestinal human cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing useof nanomaterials in consumer products and biomedical applications creates the possibilities of intentional/unintentional exposure to humans and the environment. Beyond the physiological limit, the nanomaterialexposure to humans can induce toxicity. It is difficult to define toxicity of nanoparticles on humans as it varies by nanomaterialcomposition, size, surface properties and the target organ/cell line. Traditional tests for nanomaterialtoxicity assessment are mostly based on bulk-colorimetric assays. In many studies, nanomaterials have found to interfere with assay-dye to produce false results and usually require several hours or days to collect results. Therefore, there is a clear need for alternative tools that can provide accurate, rapid, and sensitive measure of initial nanomaterialscreening. Recent advancement in single cell studies has suggested discovering cell properties not found earlier in traditional bulk assays. A complex phenomenon, like nanotoxicity, may become clearer when studied at the single cell level, including with small colonies of cells. Advances in lab-on-a-chip techniques have played a significant role in drug discoveries and biosensor applications, however, rarely explored for nanomaterialtoxicity assessment. We presented such cell-integrated chip-based approach that provided quantitative and rapid response of cellhealth, through electrochemical measurements. Moreover, the novel design of the device presented in this study was capable of capturing and analyzing the cells at a single cell and small cell-population level. We examined the change in exocytosis (i.e. neurotransmitterrelease) properties of a single PC12 cell, when exposed to CuOand TiO2 nanoparticles. We found both nanomaterials to interfere with the cell exocytosis function. We also studied the whole-cell response of a single-cell and a small cell-population simultaneously in real-time for the first time. The presented study can be a reference to the future research in the direction of nanotoxicity assessment to develop miniature, simple, and cost-effective tool for fast, quantitative measurements at high throughput level. The designed lab-on-a-chip device and measurement techniques utilized in the present work can be applied for the assessment of othernanoparticles' toxicity, as well.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As dietas de baixo índice glicêmico e baixa carga glicêmica têm sido associadas à redução do risco de doenças crônicas. Por esse motivo há um interesse crescente na sua aplicação para avaliação e orientação nutricional. No entanto, existem limitações quanto ao uso de dados publicados de índice glicêmico e carga glicêmica, pela variedade e formas de processamento dos alimentos vegetais existentes. Devido à dificuldade de realização de ensaios in vivo, uma vez que são custosos, trabalhosos, invasivos e necessitam de período considerável de experimentação, foram desenvolvidas metodologias in vitro que, a partir da velocidade de digestão dos carboidratos, permitem estimar o índice glicêmico dos alimentos de forma prática, simples e econômica. O presente trabalho apresenta o uso de um marcador in vitro, o índice de hidrólise, na estimativa do índice glicêmico e da carga glicêmica, o método mais empregado por pesquisadores brasileiros, visando à sua aplicação por profissionais da área de Nutrição. Os cálculos e as interpretações para estimativa do Índice glicêmico e da carga glicêmica são apresentados por meio de um exemplo prático com alguns alimentos brasileiros e com o grão de amaranto submetido a diferentes processamentos. Na ausência de dados referentes à resposta glicêmica do alimento de interesse, os valores do marcador in vitro podem ser utilizados para estimar o índice glicêmico e a carga glicêmica dos alimentos. Porém, este marcador não deve ser utilizado indiscriminadamente, uma vez que leva em consideração apenas os fatores intrínsecos aos alimentos que influenciam o aproveitamento dos carboidratos disponíveis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Epithelial malignancies are common in immunosuppressed individuals and the general population. However the mechanisms by which the adaptive immune system can eliminate immunogenic epithelial cells remain undefined. The aim of this project was to determine the effector molecules required for induction of apoptosis in murine epidermal keratinocytes (MEKs) in vitro and in vivo. HPV16E7-specific CTL lines and T cell receptor transgenic (E7TCRtg) effector cells were obtained from wild type (wt)-C57 and syngeneic mice rendered functionally inactive for perforin (Pfp), interferon-g (IFN-g) or FasL. CTLs or E7TCRtg spleen cells were co-cultured with primary MEKs in vitro or transferred into skin graft recipients. Inhibition of colony formation and skin graft rejection were used as indicators of T cell:KC interaction. Wt E7-specific CTLs and CTLs deficient in perforin, FasL or IFN-g produced mean reductions in colony formation of 67% (62.4–71.3%), 72% (71.1–72%), 76% (73–78%) and 21.5% (14– 34%) respectively. Wt, perforin deficient or FasL deficient CTLs all induced rejection of skin grafts (wt: 6/12; Pfp: 9/15; FasL: 3/13 survival). Transfer and immunisation of wt E7TCRtg spleen cells induces rejection of 50% of grafts (4/8 survival). In contrast, perforin or IFN-g deficient E7TCRtg failed to induce graft rejection (5/6; 4/4 survival). FasL deficient E7TCRtg induced nonspecific rejection of grafts (E7- 2/6 survival; C57- 4/7 survival). Therefore IFN-g production by CTL is necessary and sufficient in vitro and in vivo to kill epithelial cells which express a nonself antigen. Assessment of immunotherapies directed against epithelial tissues may be more effectively achieved by assaying the amount of IFN-g production by CD8 T cells, and the number and affinity of those cells, in conjunction with quantitation of perforin mediated effects in short term assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Gaps between an abutment and a dental implant are unavoidable, and microleakage may occur, leading to problems such as malodor and peri-implantitis. The aim of the present in vitro study was to investigate leakage of Staphylococcus aureus through the implant/abutment interface by the method of bacterial culture, and to compare the leakage rates of two different types of implant-abutment connections. Materials and Methods: Twenty Morse taper implants with abutments were divided into two groups: group A, which were evaluated for microleakage into the inner part of the implants, and group B, which were evaluated for microleakage from the inner part of the implants. Twenty internal-hexagon implants with abutments were also divided into two groups: group C, which were evaluated for microleakage into the inner part of the implants, and group D, which were evaluated for microleakage from the inner part of the implants. For the evaluation of leakage from the implants, the assemblies had the inner parts inoculated with S aureus, and each assembly was incubated in sterile brain heart infusion broth for 1 week. For assessment of leakage into the implants, each assembly was submerged in 4 mL S aureus culture in tubes and incubated for 2 weeks. The microleakage of the two implant connections was compared. Results: Microbial leakage occurred in all groups, and there was no statistically significant difference between groups A and C or between groups B and D. Conclusions: In vitro, S aureus leakage through the implant/abutment interface occurred with both Morse taper and internal-hexagon implants. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:56-62