921 resultados para Hot-water heating


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This was a comparative study of the possibility of a net zero energy house in Queensland, Australia. It examines the actual energy use and thermal comfort conditions of an occupied Brisbane home and compares performance with the 10 star scale rating scheme for Australian residential buildings. An adaptive comfort psychometric chart was developed for this analysis. The house's capacity for the use of the natural ventilation was studied by CFD modelling. This study showed that the house succeeded in achieving the definition of net zero energy on an annual and monthly basis for lighting, cooking and space heating / cooling and for 70% of days for lighting, hot water and cooking services.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose We investigated the effects of weed control and fertilization at early establishment on foliar stable carbon (δ13C) and nitrogen (N) isotope (δ15N) compositions, foliar N concentration, tree growth and biomass, relative weed cover and other physiological traits in a 2-year old F1 hybrid (Pinus elliottii var. elliottii (Engelm) × Pinus caribaea var. hondurensis (Barr. ex Golf.)) plantation grown on a yellow earth in southeast Queensland of subtropical Australia. Materials and methods Treatments included routine weed control, luxury weed control, intermediate weed control, mechanical weed control, nil weed control, and routine and luxury fertilization in a randomised complete block design. Initial soil nutrition and soil fertility parameters included (hot water extractable organic carbon (C) and total nitrogen (N), total C and N, C/N ratio, labile N pools (nitrate (NO3 −) and ammonium (NH4 +)), extractable potassium (K+)), soil δ15N and δ13C. Relative weed cover, foliar N concentrations, tree growth rate and physiological parameters including photosynthesis, stomatal conductance, photosynthetic nitrogen use efficiency, foliar δ15N and foliar δ13C were also measured at early establishment. Results and discussion Foliar N concentration at 1.25 years was significantly different amongst the weed control treatments and was negatively correlated to the relative weed cover at 1.1 years. Foliar N concentration was also positively correlated to foliar δ15N and foliar δ13C, tree height, height growth rates and tree biomass. Foliar δ15N was negatively correlated to the relative weed cover at 0.8 and 1.1 years. The physiological measurements indicated that luxury fertilization and increasing weed competition on these soils decreased leaf xylem pressure potential (Ψxpp) when compared to the other treatments. Conclusions These results indicate how increasing N resources and weed competition have implications for tree N and water use at establishment in F1 hybrid plantations of southeast Queensland, Australia. These results suggest the desirability of weed control, in the inter-planting row, in the first year to maximise site N and water resources available for seedling growth. It also showed the need to avoid over-fertilisation, which interfered with the balance between available N and water on these soils.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Solar distillation can be used to produce potable water from contaminated water. However, studies show that ions such as F(-) and NO(3)(-) occur in distillates from solar stills. In order to understand the reasons for this behavior, imaging and distillation experiments were conducted. White dots were seen in the vapor space above the interface of hot water poured into containers. The concentrations of various ions such as F(-) and SO(4)(2-) in the distillates from thermal and solar distillation experiments were roughly comparable when the feed consisted of deionized water and also solutions having fluoride concentrations of 100 and 10 000 mg/L. These observations suggest that aerosols enter the distillation setup through leaks and provide nuclei for the condensation of water vapor. The water-soluble component of aerosols dissolves in the drops formed, and some of the drops are transferred to the distillate by buoyancy-driven convection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

[ES]Comparativa de las alternativas disponibles para la construcción de un edificio, con el objetivo de optimizar el diseño disminuyendo las pérdidas de energía. De los distintos tipos de construcciones posibles, la investigación se centra en una vivienda unifamiliar. El trabajo aborda, por una parte, el diseño de la envolvente de la vivienda con las técnicas eficientes y los materiales mejor ajustados a la zona de edificación; y por otra, la selección del sistema de calefacción y de agua caliente sanitaria (ACS). Se opta por bloques de tierra comprimida, aislante de celulosa y enlucido de arcilla para las paredes, así como por una caldera de pellets para el sistema de calefacción y una instalación de energía solar térmica para el ACS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

[ES]Mediante este trabajo se tiene como objetivo la obtención de la calificación energética de la vivienda de Ekaitz Roldán, así como un análisis de posibles mejoras. Para obtener la certificación se usará la herramienta informática CE3X, que se vale de métodos simplificados para conseguirla. Se estudiarán diversos caminos para mejorar el resultado obtenido, existiendo predilección por la actuación sobre las instalaciones térmicas, principalmente sobre la caldera. Mejoras sobre la arquitectura de la casa no se contemplan en principio por ser una casa de relativamente nueva construcción. Se ha obtenido una calificación final de 28,7 (E), y sustituyendo el equipo de agua caliente sanitaria y calefacción por uno que use biomasa como combustible se ha logrado mejorar a 1,3 (A).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

[ES]Este trabajo consiste en el análisis y dimensionamiento de una planta de biomasa que utiliza cardo procedente de cultivo energético para la generación de 3 MWe y la energía térmica suficiente para garantizar ACS (agua caliente sanitaria) y calefacción, mediante un sistema de district heating, a unos pocos miles de habitantes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neste trabalho é apresentado o desenvolvimento de um programa computacional que simula o desempenho térmico de um sistema de aquecimento solar de água com circulação forçada, adequado para uso em edificações. O programa trabalha realizando o balanço de massa e de energia no reservatório térmico a cada hora, tendo como valores de entrada dados do ano meteorológico típico da localidade selecionada e a vazão de água quente de consumo. Os componentes do sistema são o reservatório térmico de água quente com aquecedor auxiliar interno, o coletor solar e a bomba de circulação. A base de dados meteorológicos escolhida foi a do projeto SWERA, que contém arquivos no formato padrão TMY disponíveis na internet para um número considerável de cidades, incluindo diversas localidades brasileiras. Foi proposto um modelo de temperatura de água da rede de abastecimento relacionado com a temperatura do solo, dado disponível nos arquivos de entrada utilizados. O programa utilizou como referência para a validação dos modelos de cálculo resultados obtidos pelo programa comercial de simulação TRNSYS. Foram comparados resultados para os modelos de irradiação incidente em superfície inclinada, do coletor solar e do sistema completo. Para isto foram simulados sistemas localizados em quatro cidades distintas com climas diferentes. O tempo total usado nas simulações foi de um ano e os resultados das comparações dos valores resultantes foram considerados satisfatórios.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The water and sewerage sectors' combined emissions account for just over 1% of total UK emissions, while household water heating accounts for a further 5%. Energy use, particularly electricity, is the largest source of emissions in the sector. Water efficiency measures should therefore result in reduced emissions from a lower demand for water and wastewater treatment and pumping, as well as from decreased domestic water heating. Northern Ireland Water (NI Water) is actively pursuing measures to reduce its carbon footprint. This paper investigated the carbon impacts of implementing a household water efficiency programme in Northern Ireland. Assuming water savings of 59.6 L/prop/day and 15% uptake among households, carbon savings of 0.6% of NI Water's current net operational emissions are achievable from reduced treatment and pumping. Adding the carbon savings from reduced household water heating gives savings equivalent to 6.2% of current net operational emissions. Cost savings to NI Water are estimated as 300,000 per year. The cost of the water efficiency devices is approximately 1.6 million, but may be higher depending on the number of devices distributed relative to the number installed. This paper has shown clear carbon benefits to water efficiency, but further research is needed to examine social and cost impacts. © IWA Publishing 2013.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

EU targets require nearly zero energy buildings (NZEB) by 2020. However few monitored examples exist of how NZEB has been achieved in practise in individual residential buildings. This paper provides an example of how a low-energy building (built in 2006), has achieved nearly zero energy heating through the addition of a solar domestic hot water and space heating system (“combi system”) with a Seasonal Thermal Energy Store (STES). The paper also presents a cumulative life cycle energy and cumulative life cycle carbon analysis for the installation based on the recorded DHW and space heating demand in addition to energy payback periods and net energy ratios. In addition, the carbon and energy analysis is carried out for four other heating system scenarios including hybrid solar thermal/PV systems in order to obtain the optimal system from a carbon efficiency perspective.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel way of cooking rice to maximize the removal of the carcinogen inorganic arsenic (Asi) is presented here. In conventional rice cooking water and grain are in continuous contact, and it is known that the larger the water:rice cooking ratio, the more Asi removed by cooking, suggesting that the Asi in the grain is mobile in water. Experiments were designed where rice is cooked in a continual stream of percolating near boiling water, either low in Asi, or Asi free. This has the advantage of not only exposing grain to large volumes of cooking water, but also physically removes any Asi leached from the grain into the water receiving vessel. The relationship between cooking water volume and Asi removal in conventional rice cooking was demonstrated for the rice types under study. At a water-to-rice cooking ratio of 12:1, 57±5% of Asi could be removed, average of 6 wholegrain and 6 polished rice samples. Two types of percolating technology were tested, one where the cooking water was recycled through condensing boiling water steam and passing the freshly distilled hot water through the grain in a laboratory setting, and one where tap water was used to cook the rice held in an off-the-shelf coffee percolator in a domestic setting. Both approaches proved highly effective in removing Asi from the cooking rice, with up to 85% of Asi removed from individual rice types. For the recycled water experiment 59±8% and 69±10% of Asi was removed, on average, compared to uncooked rice for polished (n=27) and wholegrain (n=13) rice, respectively. For coffee percolation there was no difference between wholegrain and polished rice, and the effectiveness of Asi removal was 49±7% across 6 wholegrain and 6 polished rice samples. The manuscript explores the potential applications and further optimization of this percolating cooking water, high Asi removal, discovery.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper explores the potential for façade located solar thermal collectors. Building typologies with limited roof space area are highlighted. A relationship exists between hot water consumption and the solar collector area; hence, a literature review of the hot water consumption of different building typologies is conducted. The review showed that there is a paucity of information on the hot water consumption of buildings, primarily attributed to the difficulty in quantifying it. The hot water consumption is typically describedusing liters per capita per day (Lcd) units, with a broad range of values existing, dependent, primarily on the building's function and location. Asimulation-based study is conducted to size solar thermal systems for different buildings and their associated hot water loads. High solar fractions,for buildings with high levels of hot water consumption, could only be achievedby using significantly largercollector surface areas. As a result, façade located solar thermal collectors are required for certain high-rise buildings that aim to provide for their hot water needs using a considerable portion of solar energy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Solar heating systems have the potential to be an efficient renewable energy technology, provided they are sized correctly. Sizing a solar thermal system for domestic applications does not warrant the cost of a simulation. As a result simplified sizing procedures are required. The size of a system depends on a number of variables including the efficiency of the collector itself, the hot water demand and the solar radiation at a given location. Domestic Hot Water (DHW) demand varies with time and is assessed using a multi-parameter detailed model. Secondly, the national energy evaluation methodologies are evaluated from the perspective of solar thermal system sizing. Based on the assessment of the standards, limitations in the evaluation method for solar thermal systems are outlined and an adapted method, specific to the sizing of solar thermal systems, is proposed. The methodology is presented for two common dwelling scenarios. Results from this showed that it is difficult to achieve a high solar fraction given practical sizes of system infrastructure (storage tanks) for standard domestic properties. However, solar thermal systems can significantly offset energy loads due associated DHW consumption, particularly when sized appropriately. The presented methodology is valuable for simple solar system design and also for the quick comparison of salient criteria.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A domótica é uma área com grande interesse e margem de exploração, que pretende alcançar a gestão automática e autónoma de recursos habitacionais, proporcionando um maior conforto aos utilizadores. Para além disso, cada vez mais se procuram incluir benefícios económicos e ambientais neste conceito, por forma a garantir um futuro sustentável. O aquecimento de água (por meios elétricos) é um dos fatores que mais contribui para o consumo de energia total de uma residência. Neste enquadramento surge o tema “algoritmos inteligentes de baixa complexidade”, com origem numa parceria entre o Departamento de Eletrónica, Telecomunicações e Informática (DETI) da Universidade de Aveiro e a Bosch Termotecnologia SA, que visa o desenvolvimento de algoritmos ditos “inteligentes”, isto é, com alguma capacidade de aprendizagem e funcionamento autónomo. Os algoritmos devem ser adaptados a unidades de processamento de 8 bits para equipar pequenos aparelhos domésticos, mais propriamente tanques de aquecimento elétrico de água. Uma porção do desafio está, por isso, relacionada com as restrições computacionais de microcontroladores de 8 bits. No caso específico deste trabalho, foi determinada a existência de sensores de temperatura da água no tanque como a única fonte de informação externa aos algoritmos, juntamente com parâmetros pré-definidos pelo utilizador que estabelecem os limiares de temperatura máxima e mínima da água. Partindo deste princípio, os algoritmos desenvolvidos baseiam-se no perfil de consumo de água quente, observado ao longo de cada semana, para tentar prever futuras tiragens de água e, consequentemente, agir de forma adequada, adiantando ou adiando o aquecimento da água do tanque. O objetivo é alcançar uma gestão vantajosa entre a economia de energia e o conforto do utilizador (água quente), isto sem que exista necessidade de intervenção direta por parte do utilizador final. A solução prevista inclui também o desenvolvimento de um simulador que permite observar, avaliar e comparar o desempenho dos algoritmos desenvolvidos.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica