212 resultados para Glue


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bonding of wood with glue dates back to ancient times but has increased enormously over the past decades. This 2 page report explains the proper way to glue wood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrin sealant is used in many areas of surgery. We present a novel aspect of flap insetting in the ischial region using fibrin spray to seal the transferred tissue. We analyzed 10 patients suffering from decubital ulcers and assessed drainage output, time of drain removal, as well as complications following fasciocutaneous flap surgery. Patients were randomized to receive sprayed fibrin glue (study group) or not (control group) before wound closure. The mean drainage time was 4 +/- 1 days in the study group and 6 +/- 1 days in the control group ( P = 0.06). The mean drainage volume was 100 +/- 20 mL in the study group and 168 +/- 30 mL in the control group ( P < 0.01). Fibrin sealant led to reduced drainage volumes and duration of drainage, indicating a beneficial effect of the application of fibrin glue in fasciocutaneous flap surgery for pressure sore coverage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The holographic dual of a finite-temperature gauge theory with a small number of flavors typically contains D-brane probes in a black hole background. At low temperature, the branes sit outside the black hole and the meson spectrum is discrete and possesses a mass gap. As the temperature increases, the branes approach a critical solution. Eventually, they fall into the horizon and a phase transition occurs. In the new phase, the meson spectrum is continuous and gapless. At large Nc and large't Hooft coupling, we show that this phase transition is always first order. In confining theories with heavy quarks, it occurs above the deconfinement transition for the glue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple holographic model is presented and analyzed that describes chiral symmetry breaking and the physics of the meson sector in QCD. This is a bottom-up model that incorporates string theory ingredients like tachyon condensation which is expected to be the main manifestation of chiral symmetry breaking in the holographic context. As a model for glue the Kuperstein-Sonnenschein background is used. The structure of the flavor vacuum is analyzed in the quenched approximation. Chiral symmetry breaking is shown at zero temperature. Above the deconfinement transition chiral symmetry is restored. A complete holographic renormalization is performed and the chiral condensate is calculated for different quark masses both at zero and non-zero temperatures. The 0++, 0¿+, 1++, 1¿¿ meson trajectories are analyzed and their masses and decay constants are computed. The asymptotic trajectories are linear. The model has one phenomenological parameter beyond those of QCD that affects the 1++, 0¿+ sectors. Fitting this parameter we obtain very good agreement with data. The model improves in several ways the popular hard-wall and soft wall bottom-up models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple holographic model is presented and analyzed that describes chiral symmetry breaking and the physics of the meson sector in QCD. This is a bottom-up model that incorporates string theory ingredients like tachyon condensation which is expected to be the main manifestation of chiral symmetry breaking in the holographic context. As a model for glue the Kuperstein-Sonnenschein background is used. The structure of the flavor vacuum is analyzed in the quenched approximation. Chiral symmetry breaking is shown at zero temperature. Above the deconfinement transition chiral symmetry is restored. A complete holographic renormalization is performed and the chiral condensate is calculated for different quark masses both at zero and non-zero temperatures. The 0++, 0¿+, 1++, 1¿¿ meson trajectories are analyzed and their masses and decay constants are computed. The asymptotic trajectories are linear. The model has one phenomenological parameter beyond those of QCD that affects the 1++, 0¿+ sectors. Fitting this parameter we obtain very good agreement with data. The model improves in several ways the popular hard-wall and soft wall bottom-up models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many strategies have been investigated to provide an ideal substitute to treat a nerve gap injury. Initially, silicone conduits were used and more recently conduits fabricated from natural materials such as poly-3-hydroxybutyrate (PHB) showed good results but still have their limitations. Surgically, a new concept optimising harvested autologous nerve graft has been introduced as the single fascicle method. It has been shown that a single fascicle repair of nerve grafting is successful. We investigated a new approach using a PHB strip seeded with Schwann cells to mimic a small nerve fascicle. Schwann cells were attached to the PHB strip using diluted fibrin glue and used to bridge a 10-mm sciatic nerve gap in rats. Comparison was made with a group using conventional PHB conduit tubes filled with Schwann cells and fibrin glue. After 2 weeks, the nerve samples were harvested and investigated for axonal and Schwann cell markers. PGP9.5 immunohistochemistry showed a superior nerve regeneration distance in the PHB strip group versus the PHB tube group (> 10 mm, crossed versus 3.17+/- 0.32 mm respectively, P<0.05) as well as superior Schwann cell intrusion (S100 staining) from proximal (> 10 mm, crossed versus 3.40+/- 0.36 mm, P<0.01) and distal (> 10 mm, crossed versus 2.91+/- 0.31 mm, P<0.001) ends. These findings suggest a significant advantage of a strip in rapidly connecting a nerve gap lesion and imply that single fascicle nerve grafting is advantageous for nerve repair in rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optimal seeding of a nerve conduit with cells is a core problem in tissue engineering of constructing an artificial nerve substitute to gap lesions in the peripheral nerve system. An ideal nerve gap substitute would have to present an equally distributed number of cells that can activate the regrowing axons. This work shows a new in vitro technique of two-step seeding of cells inside a conduit and on layered mats that allows a valuable targeting of the cells and a proven survival in the environment of poly-3-hydroxybutyrate (PHB) conduits. The technique uses two components of diluted fibrin glue Tisseel. Initially, the chosen area on the mat was coated with thrombin followed from the seeding of a fibrinogen-cell compound. Using Sprague Dawley rat cells, we could demonstrate with immunohistochemistry (S100, DAPI) techniques that undifferentiated (uMSC) and Schwann cells (SC) mimicking differentiated mesenchymal stem cells (dMSC) as well as SC can be suspended and targeted significantly better in dissolvable diluted fibrin glue than in growth medium. Analysis showed significantly better values for adherence (p < 0.001) and drop off (p < 0.05) from seeded cells. Using this two-step application allows the seeding of the cells to be more precise and simplifies the handling of cell transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the safety and efficacy of stenting in upper airway reconstructions for benign laryngotracheal stenosis (LTS) with a newly designed prosthesis, the LT-Mold?. The LT-Mold and its proper use during open surgery and endoscopy are described, and the experience gathered from a prospectively collected database on 65 patients treated for complex LTS or severe aspiration is reported. This series is compared to the results of other stenting methods. All patients were available for evaluation. In all but one case, the prosthesis was removed at the end of the study. The new prosthesis did not induce any stent-related trauma to the supraglottis, glottis and subglottis. Before adding a distal round-shaped silicone cap to the LT-Mold, granulation tissue was usually seen at the stent-mucosal interface at the tracheostoma level. In 14 cases, there has been a spontaneous extrusion of the prosthesis through the mouth; this problem was solved by fixing the prosthesis through the reinforced portion of the prosthesis at the cap level and by adding one fixation stitch in the supraglottis. We have to document the loss of the silicone cap in three cases. This problem was resolved by designing a new prototype with an integrated cap, glued with a slow hardening silicone glue. Fifty-four (83 %) of 65 patients were decannulated after a mean duration of stenting of 3 months (range 1-12 months). The mean follow-up after decannulation was 23 months (range 1 month to 10 years). The experience gathered with the LT-Mold shows that long-term stenting for complex LTS is safely achieved when the prosthesis is used with its distal integrated silicone cap. The softness and smoothness of the prosthesis with a round-shaped configuration of both extremities help avoid ulceration and granulation tissue formation in the reconstructed airway. Adequate fixation is mandatory to avoid extrusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrin glue products and collagen patches are frequently used as a sealing product, preventing surgical side bleedings. This is especially true in the field of cardiovascular surgery, where increasing numbers of patients are being operated with antiplatelet and anticoagulation therapy. The aim of this report was, in an in vitro hemodynamic setting, to examine the sealant properties of the TachoSil (Nycomed Pharma, Linz, Austria) patch. Burst pressure and normal force of 15 TachoSil sealed defects were measured. This was determined in a closed hydraulic system. Mean burst pressure load for a 5-mm defect was 69+/-11.4 mmHg; for a 7-mm defect was 63+/-16 mmHg; and, 62+/-16 mmHg for the defect with a diameter of 10 mm (P>0.05). The mean calculated normal force was as follows: 0.91+/-0.15 N for the 5 mm defect, 6.5+/-1.6 N for the 7 mm, and 8.1+/-0.75 N for the 10 mm defect. The TachoSil patch has the capability to seal small defects. However, at the larger defects the seal character was significantly reduced. These results suggest that the device may be a good alternative for hemostasis for small defects. The capacity to curtail or stop hemorrhage at the larger defects is unlikely.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi parametrizar e avaliar o modelo DSSAT/Canegro para cinco variedades brasileiras de cana-de-açúcar. A parametrização foi realizada a partir do uso de dados biométricos e de crescimento das variedades CTC 4, CTC 7, CTC 20, RB 86-7515 e RB 83-5486, obtidos em cinco localidades brasileiras. Foi realizada análise de sensibilidade local para os principais parâmetros. A parametrização do modelo foi feita por meio da técnica de estimativa da incerteza de probabilidade generalizada ("generalized likelihood uncertainty estimation", Glue). Para a avaliação das predições, foram utilizados, como indicadores estatísticos, o coeficiente de determinação (R²), o índice D de Willmott e a raiz quadrada do erro-médio (RMSE). As variedades CTC apresentaram índice D entre 0,870 e 0,944, para índice de área foliar, altura de colmo, perfilhamento e teor de sacarose. A variedade RB 83-5486 apresentou resultados similares para teor de sacarose e massa de matéria fresca do colmo, enquanto a variedade RB 86-7515 apresentou valores entre 0,665 e 0,873, para as variáveis avaliadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää ja varmistaa uuden pakkauskoneen riittävä käyttövarmuus. Käyttövarmuuden selvittämistä varten tutustuttiin käyttövarmuuden käsitteisiin jatunnuslukuihin, sekä selvitettiin kunnossapidon merkitystä käyttövarmuuteen. Pakkauskoneen käyttövarmuutta analysoitiin vikapuumallin avulla. Analysointia varten laadittu vikapuumalli koostuu 391 perustapahtumasta ja yhteensä 629 tapahtumasta. Käyttövarmuusanalyysi suoritettiin kvalitatiivisesti ja kvantitatiivisesti. Analysointi painottuu kuitenkin kvantitatiiviseen simulointiin. Käyttövarmuusanalysoinnin apuna käytettiin simulointiohjelmaa. Käyttövarmuusvaatimukseksi asetettiin 99 % käytettävyys vuoden käyttöjakson aikana. Vikapuuanalyysin tuloksena saatiin arvio pakkauskoneen kokonaiskäytettävyydestä. Kokonaiskäytettävyydeksi muodostui 96,44 %, joka ei täytä käyttövarmuusvaatimusta. Yksittäisistä komponenttityypeistä epäluotettavimpia olivat liimalaitteiston ja paineilmajärjestelmän komponentit. Analysointityökalun avulla voitiin osoittaa käyttövarmuutta parantavien osatekijöiden vaikutukset saatuun kokonaiskäytettävyyteen. Käyttövarmuuteen voitiin vaikuttaa kunnossapidon avulla, lyhentämällä korjausaikaa ja varmentamalla komponentteja. Esitettyjen keinojen avulla käytettävyyttä on mahdollista nostaa n. 2,18 prosenttiyksikköä. Toimenpidesuositukset esitettiin saatujen tulosten ja työssä havainnoitujen asioiden perusteella. Käytettävyyden parantamiseksi ja varmistamiseksi suositetaan oikeanlaisia kunnossapitotoimenpiteitä, tehokkaan vikadiagnostiikan rakentamista sekä antureiden varmentamista. Käyttökunnonvalvonta suositetaan suoritettavaksi määräaikaistarkastuksina. Käyttökuntoa on aloitettava seuraamaan pidemmällä aikavälillä tapahtuvina häiriöraportointeina. Lisäksi tulevaisuudessa on vaadittava käyttövarmuustakuut toimittajilta laitehankintojen yhteydessä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrin sealant is used in many areas of surgery. We present a novel aspect of flap insetting in the ischial region using fibrin spray to seal the transferred tissue. We analyzed 10 patients suffering from decubital ulcers and assessed drainage output, time of drain removal, as well as complications following fasciocutaneous flap surgery. Patients were randomized to receive sprayed fibrin glue (study group) or not (control group) before wound closure. The mean drainage time was 4 +/- 1 days in the study group and 6 +/- 1 days in the control group ( P = 0.06). The mean drainage volume was 100 +/- 20 mL in the study group and 168 +/- 30 mL in the control group ( P < 0.01). Fibrin sealant led to reduced drainage volumes and duration of drainage, indicating a beneficial effect of the application of fibrin glue in fasciocutaneous flap surgery for pressure sore coverage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Puukuitulujitteisten muovikomposiittien käyttömäärät ovat maailmanlaajuisesti kasvaneet jatkuvasti viimeisen 15 vuoden aikana.Kasvun on ennustettu jatkuvan voimakkaana myös tulevaisuudessa. Diplomityön tavoitteena oli selvittää puukuitulujitteisten muovikomposiittimateriaalien soveltuvuus erääseen, mahdollisesti rakennusteollisuuden käyttöön tulevaan, tuotteeseen. Tutkittaviksi materiaaliyhdistelmiksi valittiin sekä kerta- että kestomuovin ja puu- jauhon seos. Puujauho oli koivupuista sahaus- ja hiontajätettä. Molemmissa tapauksissa puun osuus komposiitissa oli 30 p-%. Koekappaleiden valmistuksessakäytettiin koivupuisia muotteja, joihin materiaali annosteltiin. Kertamuovin japuujauhon seos kovettui huoneenlämmössä. Kestomuovin ja puujauhon seoksen sulatukseen käytettiin lämmitettävillä puristinlevyillä varustettua aihiopuristinta. Koekappaleille määritettiin taivutuslujuudet taivutuskokeen avulla. Koekappaleiden taivutuslujuuksia verrattiin mm. lattialastulevyn ja koivuliimalevyn arvoihin. Liimalevyn taivutuslujuus muihin verrattuna oli huomattavasti suurempi. Komposiittimateriaalista valmistettujen koekappaleiden taivutuslujuus oli lähellä lattia-lastulevyn tasoa, osittain jonkin verran parempikin. Diplomityössä saatujen tulosten perusteella voidaan todeta puukuitulujitteisilla muovikomposiiteilla olevan kehityspotentiaalia myös tutkimuskohteen tyyppisissä ratkaisuissa. Jatkotutkimusta tulisi kohdistaa ennen kaikkea kestomuovipohjaisen komposiittimateriaalinsuuntaan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An ideal substitute to treat a nerve gap has not been found. Initially, silicone conduits were employed. Later, conduits were fabricated from collagen or polyesters carbonates. More recently, it has been shown that a bioresorbable material, poly-3-hydroxybutyrate (PHB), can enhance nerve repair. The present investigation shows the use of fibrin as a conduit to guide nerve regeneration and bridge nerve defects. In this study we prepared and investigated a novel nerve conduit made from fibrin glue. Using a rodent sciatic nerve injury model (10-mm gap), we compared the extent of nerve regeneration through the new fibrin conduits versus established PHB conduits. After 2 and 4 weeks, conduits containing proximal and distal stumps were harvested. We evaluated the initial axon and Schwann cell stimulation using immunohistochemistry. The conduits presented full tissue integration and were completely intact. Axons crossed the gap after 1 month. Immunohistochemistry using the axonal marker PGP 9.5 showed a superior nerve regeneration distance in the fibrin conduit compared with PHB (4.1 mm versus 1.9 mm). Schwann cell intrusion (S100 staining) was similarly enhanced in the fibrin conduits, both from the proximal (4.2 mm versus 2.1 mm) and distal ends (3.2 mm versus 1.7 mm). These findings suggest an advantage of the new fibrin conduit for the important initial phase of peripheral nerve regeneration. The use of fibrin glue as a conduit is a step toward a usable graft to bridge peripheral nerve lesions. This might be clinically interesting, given the widespread acceptance of fibrin glue among the surgical community.