503 resultados para Fibular osteocutaneous flap


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined extended nerve and soft tissue defects of the upper extremity require nerve reconstruction and adequate soft tissue coverage. This study focuses on the reliability of the free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap within this indication. An anatomical study was performed on 26 cadaveric lower extremities that had been Thiel fixated and color silicone injected. Dissection of the fasciocutaneous posterior calf flap involved the medial sural nerve and superficial sural artery (SSA) with its septocutaneous perforators, extended laterally to include the lateral cutaneous branch of the sural nerve and continued to the popliteal origin of the vascular pedicle and the nerves. The vessel and nerves diameter were measured with an eyepiece reticle at 4.5× magnification. Length and diameter of the nerves and vessels were carefully assessed and reported in the dissection book. A total of 26 flaps were dissected. The SSA originated from the medial sural artery (13 cases), the popliteal artery (12 cases), or the lateral sural artery (one case). The average size of the SSA was 1.4 ± 0.4 mm. The mean pedicle length before the artery joined the sural nerve was 4.5 ± 1.9 cm. A comitant vein was present in 21 cases with an average diameter of 2.0 ± 0.8 mm, in 5 cases a separate vein needed to be dissected with an average diameter of 3.5 ± 0.4 mm. The mean medial vascularized sural nerve length was 21.2 ± 8.9 cm. Because of inclusion of the vascularized part of the lateral branch of the sural nerve (mean length of 16.7 ± 4.8 cm), a total of 35.0 ± 9.6 cm mean length of vascularized nerve could be gained from each extremity. The free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap pedicled on the SSA offers a reliable solution for complex tissue and nerve defect. Clin. Anat. 2012. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study has been to compare the clinical and radiographic outcome of periodontal intrabony defect treatment by open flap debridement alone or in combination with nanocrystalline hydroxyapatite bone substitute application. Thirty patients diagnosed with advanced periodontits were divided into two groups: the control group (OFD), in which an open flap debridement procedure was performed and the test group (OFD+NHA), in which defects were additionally filled with nanocrystalline hydroxyapatite bone substitute material. Plaque index (PI), gingival index (GI), bleeding on probing (BOP), pocket depth (PD), gingival recession (GR) and clinical attachment level (CAL) were measured prior to, then 6 and 12months following treatment. Radiographic depth and width of defects were also evaluated. There were no differences in any clinical and radiographic parameters between the examined groups prior to treatment. After treatment, BOP, GI, PD, CAL, radiographic depth and width parameter values improved statistically significantly in both groups. The PI value did not change, but the GR value increased significantly after treatment. There were no statistical differences in evaluated parameters between OFD and OFD+NHA groups 6 and 12months after treatment. Within the limits of the study, it can be concluded that the additional use of nanocrystalline hydroxyapatite bone substitute material after open flap procedure does not improve clinical and radiographic treatment outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranioplasty is a common neurosurgical procedure. Free-hand molding of polymethyl methacrylate (PMMA) cement into complex three-dimensional shapes is often time-consuming and may result in disappointing cosmetic outcomes. Computer-assisted patient-specific implants address these disadvantages but are associated with long production times and high costs. In this study, we evaluated the clinical, radiological, and cosmetic outcomes of a time-saving and inexpensive intraoperative method to mold custom-made implants for immediate single-stage or delayed cranioplasty. Data were collected from patients in whom cranioplasty became necessary after removal of bone flaps affected by intracranial infection, tumor invasion, or trauma. A PMMA replica was cast between a negative form of the patient's own bone flap and the original bone flap with exactly the same shape, thickness, and dimensions. Clinical and radiological follow-up was performed 2 months post-surgery. Patient satisfaction (Odom criteria) and cosmesis (visual analogue scale for cosmesis) were evaluated 1 to 3 years after cranioplasty. Twenty-seven patients underwent intraoperative template-molded patient-specific cranioplasty with PMMA. The indications for cranioplasty included bone flap infection (56%, n = 15), calvarian tumor resection (37%, n = 10), and defect after trauma (7%, n = 2). The mean duration of the molding procedure was 19 ± 7 min. Excellent radiological implant alignment was achieved in 94% of the cases. All (n = 23) but one patient rated the cosmetic outcome (mean 1.4 years after cranioplasty) as excellent (70%, n = 16) or good (26%, n = 6). Intraoperative cast-molded reconstructive cranioplasty is a feasible, accurate, fast, and cost-efficient technique that results in excellent cosmetic outcomes, even with large and complex skull defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The classical DIEP-flap is considered state-of-the-art in microsurgical autologous breast reconstruction. Some patients may require additional volume to match the contralateral breast. This quality control study prospectively evaluates the feasibility and outcome of a surgical technique, which pursues the volumetric augmentation of the DIEP-flap by harvesting of additional subscarpal fat tissue cranial to the classical flap border.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the influence of 17β-estradiol (E2) on nitric oxide (NO) production in endothelial cell cultures and the effect of topical E2 on the survival of skin flap transplants in a rat model. Human umbilical vein endothelial cells were treated with three different E2 concentrations and nitrite (NO2) concentrations, as well as endothelial nitric oxide synthase (eNOS) protein expressions were analyzed. In vivo, random-pattern skin flaps were raised in female Wistar rats 14 days following ovariectomy and treated with placebo ointment (group 1), E2 as gel (group 2), and E2 via plaster (group 3). Flap perfusion, survival, and NO2 levels were measured on postoperative day 7. In vitro, E2 treatment increased NO2 concentration in cell supernatant and eNOS expression in cell lysates (p < 0.05). In vivo, E2 treated (gel and plaster groups) demonstrated significantly increased skin flap survival compared to the placebo group (p < 0.05). E2 plaster-treated animals exhibited higher NO2 blood levels than placebo (p < 0.05) paralleling the in vitro observations. E2 increases NO production in endothelial cells via eNOS activation. Topical E2 application can significantly increase survival of ischemically challenged skin flaps in a rat model and may augment wound healing in other ischemic situations via activation of NO production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the authors' currently favored method of nipple reconstruction in cases of a pre-existing scar on the breast mound that passes through the intended site of nipple reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To reconstruct a forehead defect, a plastic surgeon must be knowledgeable about the neural, vascular, and muscular anatomy. The position of fixed structures such as eyebrows and hairline should be respected. For the past 5 years, we have used double hatchet flaps for reconstruction of relatively large supra-eyebrow and forehead defects. Because this flap does not appear to be among the techniques used by young plastic surgeons, we thought that it would be valuable to report our experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Based on a previous clinical case report in which the pedicled subcostal artery perforator flap allowed for the closure of a large defect of the lumbar region, the present study was designed to investigate the anatomy of the subcostal artery perforator flap and to evaluate its potential for wider clinical use. METHODS: A series of 14 human cadavers was studied and 28 subcostal artery perforator flaps were dissected. The location of the perforator vessel was charted against anatomical landmarks. Measurements included the perforator calibre, pedicle length, and flap size following methylene blue injection. The findings were compared by Doppler sonography in 15 volunteers. RESULTS: The subcostal artery perforator was present in all dissected specimens and in all volunteers. Its calibre measured in mean 2mm. The location was constant at the lateral border of the latissimus dorsi muscle and between 1 and 3cm below the lower rib end. The pedicle length reached a mean of 10.5cm when dissected up to the border of the erector spinae musculature. The vascular supply covered a mean flap size of 10x14cm. The in vivo investigations confirmed the constant perforator location from the anatomical landmarks. CONCLUSION: This anatomical study reveals a considerable potential for the clinical use of the subcostal artery perforator flap for defect coverage in the lumbar area, due to its constant and reliable anatomy. Doppler sonography can be helpful in preoperative assessment of the size and the position of the subcostal perforator, thus allowing for an optimal flap design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The final goal of mandibular reconstruction following ablative surgery for oral cancer is often considered to be dental implant-supported oral rehabilitation, for which bone grafts should ideally be placed in a suitable position taking subsequent prosthetic restoration into account. The aim of this study was to evaluate the efficacy of a standardized treatment strategy for mandibular reconstruction according to the size of the bony defect and planned subsequent dental prosthetic rehabilitation. Data of 56 patients, who had undergone such a systematic mandibular fibula free flap reconstruction, were retrospectively analyzed. Early complications were observed in 41.5% of the patients but only in those who had been irradiated. Late complications were found in 38.2%. Dental implant survival rate was 92%, and dental prosthetic treatment has been completed in all classes of bony defects with an overall success rate of 42.9%. The main reasons for failure of the complete dental reconstruction were patients' poor cooperation (30.4%) and tumour recurrence (14.3%) followed by surgery-related factors (10.8%) such as implant failure and an unfavourable intermaxillary relationship between the maxilla and the mandible. A comparison of our results with the literature findings revealed no marked differences in the complication rates and implant survival rates. However, a systematic concept for the reconstructive treatment like the method presented here, plays an important role in the successful completion of dental reconstruction. The success rate could still be improved by some technical progress in implant and bone graft positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate postoperative oral functions of patients who had undergone total or subtotal (75%) glossectomy with preservation of the larynx for oral squamous cell carcinomas. METHODS: Speech intelligibility and swallowing capacity of 17 patients who had been treated between 1992 and 2002 were scored and classified using standard protocols 6 to 36 months postoperatively. The outcomes were finally rated as good, acceptable, or poor. RESULTS: The 4-year disease-specific survival rate was 64%. Speech intelligibility and swallowing capacity were satisfactory (acceptable or good) in 82.3%. Only 3 patients were still dependent on tube feeding. Good speech perceptibility did not always go together with normal diet tolerance, however. CONCLUSIONS: Our satisfactory results are attributable to the use of large, voluminous soft tissue flaps for reconstruction, and to the instigation of postoperative swallowing and speech therapy on a routine basis and at an early juncture. (c) 2008 Wiley Periodicals, Inc. Head Neck, 2008.