903 resultados para Femoral shaft Fractures


Relevância:

40.00% 40.00%

Publicador:

Resumo:

During the past decade several new techniques for the treatment of children's fractures respecting the specificity of the growing bone have been described. The goal of all these techniques was to mechanically stabilise the fracture however to preserve a certain instability of the fracture gap itself inducing early callus formation and subsequent consolidation. The dynamic external fixation as well as the elastic stable intramedullary pinning have become accepted means in the treatment of long bone fractures in the paediatric age group. We report our experience of the last seven years with the intramedullary pinning of 105 fractures. Eighty-four were fractures of the femur, 9 of the humerus, 8 of the forearm, and a further 4 of the tibial shaft. The intramedullary elastic pinning represents a simple technique which supports or even enhances the natural process of fracture healing of the growing bone. The method is not very invasive, is cost effective, and allows short hospitalisation. Early physical activity is guaranteed due to early consolidation of the fracture. Complications are rare and the final orthopedic and cosmetic outcome is excellent.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intramedullary nail to be applied percutaneously in the fixation of femoral rotational osteotomies in children with cerebral palsy and evaluated its mechanical properties. Methods: The study was divided into three stages. In the first part, a prototype was designed and made based on radiographic measurements of the femoral medullary canal of ten-year-old patients. In the second, synthetic femoral models based on rapid-prototyping of 3D reconstructed images of patients with cerebral palsy were obtained and were employed to adjust the nail prototype to the morphological changes observed in this disease. In the third, rotational osteotomies were simulated using synthetic femoral models stabilized by the nail and by the AO-ASIF fixed-angle blade plate. Mechanical testing was done comparing both devices in bending-compression and torsion. Results: The authors observed proper adaptation of the nail to normal and morphologically altered femoral models, and during the simulated osteotomies. Stiffness in bending-compression was significantly higher in the group fixed by the plate (388.97 +/- 57.25 N/mm) than in that fixed by the nail (268.26 +/- 38.51 N/mm) as torsional relative stiffness was significantly higher in the group fixed by the plate (1.07 +/- 0.36 Nm/degrees) than by the nail (0.35 +/- 0.13 Nm/degrees). Conclusions: Although the device presented adequate design and dimension to fit into the pediatric femur, mechanical tests indicated that the nail was less stable than the blade plate in bending-compression and torsion. This may be a beneficial property, and it can be attributed to the more flexible fixation found in intramedullary devices.