934 resultados para Evaluation of effectiveness bioinstrumental
Resumo:
Recognition of the contribution of small firms to the UK economy has grown considerably since 1995 when this research first began. The poor record of small firms in managing health and safety effectively has caused concern, and efforts made to improve knowledge and awareness of the target group through various initiatives have had some success. This research thesis attempts to identify the range of intervention routes and methods available to reach the target group, and to consider ways of evaluating the outcome of such efforts. Various interventions were tested with small firms, including a Workshop; use of Questionnaires; short postal Reply Slip survey; leading to a closer evaluation of a specific industry- the Licensed Trade. Attitudes and beliefs of the sample were identified, and observations carried out to consider actions taken by workers and others in the workplace. These empirical research findings were used to develop the theme of Primary and Secondary interventions intended to change behaviours, and to confirm assumptions about what small firms currently do to manage health and safety risks. Guidance for small firms was developed as a Secondary intervention tool to support Primary interventions, such as inspection or insurance provision.
Resumo:
OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Defining 'effectiveness' in the context of community mental health teams (CMHTs) has become increasingly difficult under the current pattern of provision required in National Health Service mental health services in England. The aim of this study was to establish the characteristics of multi-professional team working effectiveness in adult CMHTs to develop a new measure of CMHT effectiveness. The study was conducted between May and November 2010 and comprised two stages. Stage 1 used a formative evaluative approach based on the Productivity Measurement and Enhancement System to develop the scale with multiple stakeholder groups over a series of qualitative workshops held in various locations across England. Stage 2 analysed responses from a cross-sectional survey of 1500 members in 135 CMHTs from 11 Mental Health Trusts in England to determine the scale's psychometric properties. Based on an analysis of its structural validity and reliability, the resultant 20-item scale demonstrated good psychometric properties and captured one overall latent factor of CMHT effectiveness comprising seven dimensions: improved service user well-being, creative problem-solving, continuous care, inter-team working, respect between professionals, engagement with carers and therapeutic relationships with service users. The scale will be of significant value to CMHTs and healthcare commissioners both nationally and internationally for monitoring, evaluating and improving team functioning in practice.
Resumo:
Given the seriousness of substance abuse as a child welfare problem, the purpose of this study was to examine the relative effectiveness of an inservice training curriculum for child welfare workers. The training was designed to improve worker knowledge and attitudes in working with substance abusing families. Seventy (70) child welfare workers from public and private agencies in two south Florida counties participated in a pretest/posttest control group design that also trained and retested the control group. The literature review supports that the general preparedness of child welfare workers for the issues presented by substance abusing families is in question. Confounding this problem is a lack of understanding of substance abuse dynamics, worker biases, and predispositions. The two research hypotheses focused on whether inservice training could increase worker knowledge and improve worker attitudes in working with this population. Training delivery was in the form of a five-day inservice focusing on an array of substance abuse knowledge and attitudinal topics. Separate knowledge and attitude instruments were developed for the research and were administered, before and after training, to a purposive sample of participants that were randomly assigned to the experimental and control groups. The data analysis supported the research hypotheses but raised a question. Specifically, the experimental group demonstrated significant improvement in posttest scores on both instruments after receiving the training; whereas the control group, with training withheld, also demonstrated a significant improvement at posttest, but only on the knowledge instrument. Although the question was unanswered, when examined at a more critical significance level, only the experimental group remained significant. The hypotheses were reconfirmed when, after training and retesting, the control group also displayed significant improvement on both instruments. The findings support the conclusion that this substance abuse inservice was effective in improving worker knowledge and attitudes regarding working with substance abusing families. As an implication for social work practice, it suggests that similar inservice training can be a viable training resource when formal substance abuse training is unavailable. Additional research is suggested regarding to what degree increased substance abuse knowledge and improved worker attitudes correlate with improved practice.
Resumo:
As a result of increased terrorist activity around the world, the development of a canine training aid suitable for daily military operations is necessary to provide effective canine explosive detection. Since the use of sniffer dogs has proven to be a reliable resource for the rapid detection of explosive volatiles organic compounds, the present study evaluated the ability of the Human Scent Collection System (HSCS) device for the creation of training aids for plasticized / tagged explosives, nitroglycerin and TNT containing explosives, and smokeless powders for canine training purposes. Through canine field testing, it was demonstrated that volatiles dynamically collected from real explosive material provided a positive canine response showing the effectiveness of the HSCS in creating canine training aids that can be used immediately or up to several weeks (3) after collection under proper storage conditions. These reliable non-hazardous training aids allow its use in areas where real explosive material aids are not practical and/or available.
Resumo:
Indoor Air 2016 - The 14th International Conference Indoor Air Quality and Climate
Resumo:
Regular physical activity (PA) during childhood is associated with physical, mental, emotional and social health benefits. The constant practice of PA is considered one of the best buys available in public health. The World Health Organization (WHO) recommends to perform at least 60 minutes per day of moderate to vigorous PA for children and adolescents in order to obtain health benefits. However, globally, this level of PA is hardly achieved. Children and adolescent who do not reach the recommended levels of PA are defined as physically inactive and nowadays physical inactivity constitutes a new type of pandemic. For this reason, the WHO launched a global action plan addressing physical activity with a goal of reducing physical inactivity in children and youth. The plan also included recommendation to improve individual and community health and contribute to the social, cultural and economic development of all nations. Worldwide, children and adolescents spend a significant amount of time in school and for this reason the school represents a fundamental educational setting that can play a pivotal role increasing students’ PA. Opportunities to be physically active should not be considered purely in relation to when children attend physical education classes but also making physical activity available during the school day, such as physically active lessons, and multicomponent PA interventions. Since school-based PA interventions are quite numerous, the present thesis focused on interventions delivered during school hours and that integrate small doses of PA as part of routine instruction. This type of intervention is called “Active Breaks.” Active Breaks consists of brief 5–15 minutes sessions of PA led by teachers who introduce short bursts of PA into the academic lesson. In light of this the present thesis aims to evaluate the feasibility, efficacy and sustainability of an Active Breaks intervention targeting children to promote PA.
Resumo:
Following the latest environmental concerns, the importance of minimising the detrimental effect of emissions of terrestrial vehicles has become a major goal for the whole automotive field. The key to achieve an emission-free long term future is the electrification of vehicle fleets; this huge step cannot be taken without intermediate technologies. In this context, hybrid vehicles are fundamental to reach this goal. Specifically, mild hybrid vehicles represent a trade-off between cost and emissions that could act now as a bridge towards electrification. Like the industry, also student engineering competitions are likely to take the same route: Combustion vehicles may well turn into hybrid vehicles. For this reason, a preliminary design overview is necessary to pinpoint the key performance indicators for the prototypes of the future.
Resumo:
The aim of this clinical study was to determine the efficacy of Uncaria tomentosa (cat's claw) against denture stomatitis (DS). Fifty patients with DS were randomly assigned into 3 groups to receive 2% miconazole, placebo, or 2% U tomentosa gel. DS level was recorded immediately, after 1 week of treatment, and 1 week after treatment. The clinical effectiveness of each treatment was measured using Newton's criteria. Mycologic samples from palatal mucosa and prosthesis were obtained to determinate colony forming units per milliliter (CFU/mL) and fungal identification at each evaluation period. Candida species were identified with HiCrome Candida and API 20C AUX biochemical test. DS severity decreased in all groups (P < .05). A significant reduction in number of CFU/mL after 1 week (P < .05) was observed for all groups and remained after 14 days (P > .05). C albicans was the most prevalent microorganism before treatment, followed by C tropicalis, C glabrata, and C krusei, regardless of the group and time evaluated. U tomentosa gel had the same effect as 2% miconazole gel. U tomentosa gel is an effective topical adjuvant treatment for denture stomatitis.
Resumo:
The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.