976 resultados para EUV light source


Relevância:

80.00% 80.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this review paper different designs based on stacked p-i'-n-p-i-n heterojunctions are presented and compared with the single p-i-n sensing structures. The imagers utilise self-field induced depletion layers for light detection and a modulated laser beam for sequential readout. The effect of the sensing element structure, cell configurations (single or tandem), and light source properties (intensity and wavelength) are correlated with the sensor output characteristics (light-to-dark sensivity, spatial resolution, linearity and S/N ratio). The readout frequency is optimized showing that scans speeds up to 104 lines per second can be achieved without degradation in the resolution. Multilayered p-i'-n-p-i-n heterostructures can also be used as wavelength-division multiplexing /demultiplexing devices in the visible range. Here the sensor element faces the modulated light from different input colour channels, each one with a specific wavelength and bit rate. By reading out the photocurrent at appropriated applied bias, the information is multiplexed or demultiplexed and can be transmitted or recovered again. Electrical models are present to support the sensing methodologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A pi'n/pin a-SiC:H voltage and optical bias controlled device is presented and its behavior as image and color sensor, optical amplifier and demux device is discussed. The design and the light source properties are correlated with the sensor output characteristics. Different readout techniques are used. When a low power monochromatic scanner readout the generated carriers the transducer recognizes a color pattern projected on it acting as a direct color and image sensor. Scan speeds up to 10(4) lines per second are achieved without degradation in the resolution. If the photocurrent generated by different monochromatic pulsed channels is readout directly, the information is demultiplexed. Results show that it is possible to decode the information from three simultaneous color channels without bit errors at bit rates per channel higher than 4000 bps. Finally, when triggered by light of appropriated wavelength, it can amplify or suppress the generated photocurrent working as an optical amplifier (C) 2009 Published by Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dispersal flights of West Indian drywood termite, Cryptotermes brevis (Walker) (Isoptera: Kalotermitidae) were surveyed in the major cities of Azores. The sampling device used to estimate termite density consisted of a yellow adhesive trap (size 45 by 24 cm), placed with an artificial or natural light source in a dark attic environment. In addition, data from two other projects were used to improve the knowledge about the geographical distribution of the species. The level of infestation in the two main Azorean towns differed, with high levels in the houses of Angra do Heroísmo, whereas in Ponta Delgada, there are fewer houses with high levels of infestation. The infestation in Ponta Delgada shows a pattern of spreading from the center outward to the city's periphery, whereas in Angra do Heroísmo, there was a pattern of spreading outward from several foci. The heavy infestation observed in Angra do Heroísmo and the clear increase of infestation levels observed from 2010 to 2011 is a reason for concern and calls for an urgent application of an Integrated Pest Management (IPM) control strategy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new fluorescent sensor for nitric oxide (NO) is presented that is based on its reaction with a non fluorescent substance, reduced fluoresceinamine, producing the highly fluorescent fluoresceinamine. Using a portable homemade stabilized light source consisting of 450 nm LED and fiber optics to guide the light, the sensor responds linearly within seconds in the NO concentration range between about 10–750 µM with a limit of detection (LOD) of about 1 µM. The system generated precise intensity readings, with a relative standard deviation of less than 1%. The suitability of the sensor was assessed by monitoring the NO generated by either the nitrous acid decomposition reaction or from a NO-releasing compound. Using relatively high incubation times, the sensor also responds quantitatively to hydrogen peroxide and potassium superoxide, however, using transient signal measurements results in no interfering species.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tendo por referência a diretiva 2006/95/CE, o trabalho desenvolvido no contexto da disciplina de Dissertação/Projeto/Estágio do Mestrado de Engenharia de Instrumentação e Metrologia, decorreu nas instalações do IEP (Instituto Electrotécnico Português) e teve como objetivo principal o desenvolvimento de um procedimento de avaliação dos efeitos fotobiológicos no olho e pele provocados por fontes de emissão contínua (LED), doravante designado método alternativo ao de referência. Os dois métodos, alternativo e de referência, utilizam respectivamente um foto-radiómetro multicanal e um espetro-radiómetro. O procedimento desenvolvido (método alternativo) de acordo com a norma EN/IEC62471) consiste na aquisição dos valores de irradiância com recurso a um foto-radiómetro e posterior determinação dos valores da radiância, com os quais se faz a avaliação dos efeitos fotobiológicos, para fontes de luz LED (Light Emitting Diode) ou GLS (General Lighting Service). A consulta detalhada da norma EN/IEC62471 e a pesquisa sobre os conceitos, definições, equipamentos e metodologias relacionadas com o tema em causa, constituiu o primeiro passo deste projecto. Com recurso aos dois equipamentos, uma fonte de luz LED (módulo de 12 lâmpadas LED) é avaliada em relação aos perigos (ou riscos) actínico UV e UV-A, ao perigo da luz azul e ainda o perigo térmico na retina e térmico na pele, permitindo fazer uma análise comparativa dos resultados. O método alternativo revelou-se bastante flexível e eficaz, proporcionando bons resultados em termos da irradiância e radiância dos referidos efeitos fotobiológicos. A comparação destes resultados com os valores limites de exposição mencionados na norma EN/IEC6247 permitiu afirmar que a fonte de luz LED avaliada não representa perigo fotobiológico para a saúde humana e classifica-se no grupo de risco “isento”. Uma vez cumpridos os objectivos, entendeu-se que seria uma mais-valia para o trabalho já realizado, estudar outro caso prático. Sendo assim, fez-se a avaliação da radiação de apenas um dos LED´s que constituíam a fonte usada nos ensaios anteriores, com o espetro-radiómetro (método de referência) e com uma distância de 200 mm entre a fonte e o medidor. Neste caso verificaram-se diferenças significativas nas quantidades obtidas quando comparadas com os valores normativos. Concluiu-se que o efeito fotobiológico da luz azul insere-se no grupo de “isento”, sem perigo para a saúde. Contudo, o efeito térmico da retina apresenta um aumento considerável da quantidade de radiância, embora dentro do grupo de risco “isento”. Esta classificação de grupos de risco. Face aos resultados obtidos, pode confirmar-se que as lâmpadas LED apresentam segurança fotobiológica, atendendo aos baixos valores de irradiância e radiância dos efeitos fotobiológicos estudados. Pode ainda afirmar-se que a utilização do foto-radiómetro em alternativa ao espetro-radiómetro se revela mais eficaz do ponto de vista de metodologia prática. Este trabalho demonstra a robustez desses dois equipamentos de avaliação dos efeitos fotobiológicos, e procura estabelecer uma linha de orientação para a prevenção dos efeitos adversos na pele e olhos de todos os seres humanos sujeitos à radiação ótica artificial. Quanto às incertezas de medições, em relação ao processo de medição com foto-radiómetro, a sua estimação não se realizou, devido a não rastreabilidade entre as medições indicadas pelo fabricante, no certificado de calibração e as medidas realizadas por outras entidades. Contudo, é propõe-se a sua realização em trabalhos futuros dentro desse âmbito. As incertezas dos resultados de medições com espetro-radiómetro foram parcialmente estimadas. Atendendo às potencialidades do sistema de medição, propõe-se como trabalho futuro, a aplicação da norma IEC62478, que faz parte da aplicação da norma EN/IEC62471 na avaliação do efeito da luz azul, com base na determinação da temperatura de cor correlacionada (CCT) de lâmpadas ou sistemas de lâmpadas incluindo luminárias. Os valores de irradiância e radiância adquiridos nos processos de avaliação, tanto com foto-radiómetro como espectro-radiómetro foram gravados em ficheiro Excel para um CD e anexados a este trabalho.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Paul Scherrer Institut del Maig a l’Octubre del 2006 amb l’ajuda i supervisió dels Dr. Konstantins Jefimovs i Dr. Christian David. Focalitzar raigs X tous és una necessitat essencial per al microanàlisis, la microscopia, i fer imatges en moltes Instal·lacions de Radiació Sincrotró. Les Lents Zonals de Fresnel (FZP, de la denominació anglesa “Fresnel Zone Plates”) han demostrat donar uns punts focals amb una resolució espacial destacada i una baixa il·luminació de fons. Tanmateix, la fabricació de FZP és complexa i no totalment reproduïble. A més a més, el temps de vida de les FZP és força curt, ja que estant situades sobre membranes de nitrur de silici molt fines i altament absorbents. Per tant, hem fet esforços per implementar FZP de silici, que s’espera que siguin més resistents. L’element està fet d’una oblia de cristall de silici poc absorbent, i no presenta cap interfase entre materials. Així doncs, aquestes lents són especialment adequades per a aguantar les extremes càrregues de radiació de les fonts de raigs X més brillants. Particularment, això és molt important per a les aplicacions a les pròximes generacions de fonts de raigs X, com els Làsers d’Electrons Lliures (FEL, de la denominació anglesa “Free Electron Laser”). El silici també garanteix que no hi hagi cap banda d’absorció en el rang d’energies de la finestra de l’aigua (200-520 eV), fent aquestes lents ideals per a fer imatges de mostres biològiques. En aquest informe, hi ha una descripció detallada de tots els passos involucrats en la fabricació de les Lents Zonals de Fresnel de silici. En resum, les estructures de FZP es modelen sobre una resina utilitzant litografia per feix d’electrons i llavors el patró es transmet al silici mitjançant un gravat d’ions reactius (RIE, de la denominació anglesa ‘Reactive Ion Etching’) utilitzant una fina (20 nm) màscara de Crintermitja. Les membranes de silici es poden aprimar després de la fabricació de les estructures per a garantir una transmissió suficient fins i tot a baixes energies. Aquest informe també inclou l’anàlisi i la discussió d’alguns experiments preliminars per avaluar el rendiment de les Si FZPs fets a la línia de llum PolLux del Swiss Ligth Source amb l’ajuda dels Dr. Jörg Raabe i Dr. George Tzvetkov.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although the human-landing catch (HLC) method is the most effective for collecting anthropophilic anophelines, it has been increasingly abandoned, primarily for ethical considerations. The objective of the present study was to develop a new trap for the collection of Anopheles darlingi . The initial trials were conducted using the BG-Sentinel trap as a standard for further trap development based on colour, airflow direction and illumination. The performance of the trap was then compared with those of the CDC, Fay-Prince, counterflow geometry trap (CFG) and HLC. All trials were conducted outdoors between 06:00 pm-08:00 pm. Female specimens of An. darlingi were dissected to determine their parity. A total of 8,334 anophelines were captured, of which 4,945 were identified as An. darlingi . The best trap configuration was an all-white version, with an upward airflow and no required light source. This configuration was subsequently named BG-Malaria (BGM). The BGM captured significantly more anophelines than any of the other traps tested and was similar to HLC with respect to the number and parity of anophelines. The BGM trap can be used as an alternative to HLC for collecting anophelines.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest treball és la culminació de les pràctiques realitzades al sincrotró ALBA. Situat a Cerdanyola del Vallès, ALBA és un accelerador de 3a generació que permet emmagatzemar un feix d'electrons confinat de fins a 400 mA a 3GeV d'energia, amb l'objectiu d'obtenir llum a partir dels girs provocats al feix. Els sincrotrons moderns com el d'ALBA, el que pretenen és aconseguir un major control i estabilitat de la llum. Per aconseguir-ho, cal que el feix d'electrons que creen la llum estigui controlat al màxim i la seva òrbita sigui estable. Amb aquest objectiu els sincrotrons estant implementant sistemes de Fast Orbit FeedBack (FOFB) o sistemes realimentats de correcció ràpida de l'òrbita, per realitzar correccions d'almenys 100Hz que estabilitzin el feix d'electrons amb menys d'un 10% de l'amplada del feix (5-10μm). El treball exposa el desenvolupament d'una part del sistema de correcció ràpida de l'òrbita dels electrons (FOFB) que s'està duent a terme al sincrotró ALBA. Concretament, s’han revisat els estudis previs realitzats durant la fase de disseny del sincrotró, s’han recalculat funcions de transferència i retards de tots els elements involucrats al sistema. També s’han realitzat simulacions per confirmar la viabilitat del sistema amb les noves dades i finalment s’ha desenvolupat part de la unitat de control determinant el Hardware i s'ha adquirit dades que permetran analitzar el soroll de l'òrbita que en futurs treballs determinaran millor l'algorisme de la unitat de control.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This line of research of my group intends to establish a Silicon technological platform in the field of photonics allowing the development of a wide set of applications. Particularly, what is still lacking in Silicon Photonics is an efficient and integrable light source such an LED or laser. Nanocrystals in silicon oxide or nitride matrices have been recently demonstrated as competitive materials for both active components (electrically and optically driven light emitters and optical amplifiers) and passive ones (waveguides and modulators). The final goal is the achievement of a complete integration of electronic and optical functions in the same CMOS chip. The first part of this paper will introduce the structural and optical properties of LEDs fabricated from silicon nanostructures. The second will treat the interaction of such nanocrystals with rare-earth elements (Er), which lead to an efficient hybrid system emitting in the third window of optical fibers. I will present the fabrication and assessment of optical waveguide amplifiers at 1.54 ¿m for which we have been able to demonstrate recently optical gain in waveguides made from sputtered silicon suboxide materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photopolymerization is commonly used in a broad range of bioapplications, such as drug delivery, tissue engineering, and surgical implants, where liquid materials are injected and then hardened by means of illumination to create a solid polymer network. However, photopolymerization using a probe, e.g., needle guiding both the liquid and the curing illumination, has not been thoroughly investigated. We present a Monte Carlo model that takes into account the dynamic absorption and scattering parameters as well as solid-liquid boundaries of the photopolymer to yield the shape and volume of minimally invasively injected, photopolymerized hydrogels. In the first part of the article, our model is validated using a set of well-known poly(ethylene glycol) dimethacrylate hydrogels showing an excellent agreement between simulated and experimental volume-growth-rates. In the second part, in situ experimental results and simulations for photopolymerization in tissue cavities are presented. It was found that a cavity with a volume of 152  mm3 can be photopolymerized from the output of a 0.28-mm2 fiber by adding scattering lipid particles while only a volume of 38  mm3 (25%) was achieved without particles. The proposed model provides a simple and robust method to solve complex photopolymerization problems, where the dimension of the light source is much smaller than the volume of the photopolymerizable hydrogel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Our aim was to evaluate a fluorescence-based enhanced-reality system to assess intestinal viability in a laparoscopic mesenteric ischemia model. MATERIALS AND METHODS: A small bowel loop was exposed, and 3 to 4 mesenteric vessels were clipped in 6 pigs. Indocyanine green (ICG) was administered intravenously 15 minutes later. The bowel was illuminated with an incoherent light source laparoscope (D-light-P, KarlStorz). The ICG fluorescence signal was analyzed with Ad Hoc imaging software (VR-RENDER), which provides a digital perfusion cartography that was superimposed to the intraoperative laparoscopic image [augmented reality (AR) synthesis]. Five regions of interest (ROIs) were marked under AR guidance (1, 2a-2b, 3a-3b corresponding to the ischemic, marginal, and vascularized zones, respectively). One hour later, capillary blood samples were obtained by puncturing the bowel serosa at the identified ROIs and lactates were measured using the EDGE analyzer. A surgical biopsy of each intestinal ROI was sent for mitochondrial respiratory rate assessment and for metabolites quantification. RESULTS: Mean capillary lactate levels were 3.98 (SD = 1.91) versus 1.05 (SD = 0.46) versus 0.74 (SD = 0.34) mmol/L at ROI 1 versus 2a-2b (P = 0.0001) versus 3a-3b (P = 0.0001), respectively. Mean maximal mitochondrial respiratory rate was 104.4 (±21.58) pmolO2/second/mg at the ROI 1 versus 191.1 ± 14.48 (2b, P = 0.03) versus 180.4 ± 16.71 (3a, P = 0.02) versus 199.2 ± 25.21 (3b, P = 0.02). Alanine, choline, ethanolamine, glucose, lactate, myoinositol, phosphocholine, sylloinositol, and valine showed statistically significant different concentrations between ischemic and nonischemic segments. CONCLUSIONS: Fluorescence-based AR may effectively detect the boundary between the ischemic and the vascularized zones in this experimental model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Monissasovelluksissa on hyvin tärkeää vähentää valolähteen vaikutusta kohteen oikean värin havainnoimiseksi. Tämä on tarpeen mm. virtuaalisissa museoissa, telelääketieteessä, verkkokaupassa ja verkkorahassa. Tässä tutkielmassa on kehitetty tekniikkaa kirkkaiden heijastusten poistoon spektrikuvista. Työ sisältää katsauksen yleisen värillisen kuvan ymmärtämiseen, mihin perustuen analysoitiin erilaisia kirkkaiden heijastusten poistO'tekniikoita. Työssä kehitettiin uusi kirkkaiden heijastusten poistO'menetelmä, joka perustuu dikromaattiseen heijastus-malliin, joka kuvaa spektrisen datan objektin omaan väriin ja valaisevan valon väriin perustuen. Ehdotettu kirkkaiden heijastusten poistO'menetelmä hyödyntää erilaisia olemassaolevia menetelmiä, kuten pääkomponenttimenetelmää ja tiedon luokittelu-menetelmää. Yritys kehittää nopeasti toimiva algoritmi, joka myös suoriutuu tehtävästä hyvin, on onnistunut. Kokeet toteutettiin ehdotetun menetelmän mukaisesti ja toimivalla algoritmilla saatiin halutut lopputulokset. Edelleentyö sisältää ehdotuksia esitetyn algoritmin parantamiseksi.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tämä diplomityö liittyy Spektrikuvien tutkimiseen tilastollisen kuvamallin näkökulmasta. Diplomityön ensimmäisessä osassa tarkastellaan tilastollisten parametrien jakaumien vaikutusta väreihin ja korostumiin erilaisissa valaistusolosuhteissa. Havaittiin, että tilastollisten parametrien väliset suhteet eivät riipu valaistusolosuhteista, mutta riippuvat kuvan häiriöttömyydestä. Ilmeni myös, että korkea huipukkuus saattaa aiheutua värikylläisyydestä. Lisäksi työssä kehitettiin tilastolliseen spektrimalliin perustuvaa tekstuurinyhdistämisalgoritmia. Sillä saavutettiin hyviä tuloksia, kun tilastollisten parametrien väliset riippuvuussuhteet olivat voimassa. Työn toisessa osassa erilaisia spektrikuvia tutkittiin käyttäen itsenäistä komponenttien analyysia (ICA). Seuraavia itsenäiseen komponenttien analyysiin tarkoitettuja algoritmia tarkasteltiin: JADE, kiinteän pisteen ICA ja momenttikeskeinen ICA. Tutkimuksissa painotettiin erottelun laatua. Paras erottelu saavutettiin JADE- algoritmilla, joskin erot muiden algoritmien välillä eivät olleet merkittäviä. Algoritmi jakoi kuvan kahteen itsenäiseen, joko korostuneeseen ja korostumattomaan tai kromaattiseen ja akromaattiseen, komponenttiin. Lopuksi pohditaan huipukkuuden suhdetta kuvan ominaisuuksiin, kuten korostuneisuuteen ja värikylläisyyteen. Työn viimeisessä osassa ehdotetaan mahdollisia jatkotutkimuskohteita.