995 resultados para ELECTROCHEMICAL-CELL


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The free metal ion concentrations obtained by SSCP (stripping chronopotentiometry at scanned deposition potential) and by AGNES (absence of gradients and Nernstian equilibrium stripping) techniques have been compared and the usefulness of the combination of both techniques in the same electrochemical cell for trace metal speciation analysis is assessed. The free metal ion concentrations and the stability constants obtained for lead(II) and cadmium(II) complexation by pyridinedicarboxylic acid, by 40 nm radius carboxylated latex nanospheres and by a humic acid extracted from an ombrotrophic peat bog were determined. Whenever possible, the free metal ion concentrations were compared with the theoretical predictions of the code MEDUSA and with the free metal ion concentrations estimated from ion selective electrodes (ISE). SSCP values were in agreement with the ones obtained by AGNES, and both of them agreed reasonably with the ISE values and the theoretical predictions. For the lead(II)-humic acid, it was not possible to obtain the stability constants by SSCP due to the heterogeneity effect. However, using AGNES it is possible to obtain, for these heterogeneous systems, the free bulk metal concentration, which allows us to retrieve the stability constant at bulk conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The advantages of bimetallic nanoparticles as C - C coupling catalysts are discussed, and a simple, bottom- up synthesis method of core - shell Ni - Pd clusters is presented. This method combines electrochemical and 'wet chemical' techniques, and enables the preparation of highly monodispersed structured bimetallic nanoclusters. The double- anode electrochemical cell is described in detail. The core - shell Ni - Pd clusters were then applied as catalysts in the Hiyama cross- coupling reaction between phenyltrimethoxysilane and various haloaryls. Good product yields were obtained with a variety of iodo- and bromoaryls. We found that, for a fixed amount of Pd atoms, the core - shell clusters outperform both the monometallic Pd clusters and the alloy bimetallic Ni - Pd ones. THF is an excellent solvent for this process, with less than 2% homocoupling by-product. The roles of the stabiliser and the solvent are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new boron dipyrromethene–ferrocene (BODIPY–Fc) conjugate with pentafluorophenyl as the meso substituent and two Fc termini was synthesized and its spectroscopic and electrochemical features were analyzed. An intramolecular charge transfer from the donor Fc to the acceptor BODIPY has been predicted by theory and confirmed experimentally, leading to efficient fluorescence quenching when the dyad is in the neutral state. Fluorescence can be triggered by oxidizing both ferrocenyl units either chemically or electrochemically. Eventually, a fully reversible fluorescence switch is evidenced by coupling TIRF microscopy with electrolysis in an electrochemical cell.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work reports the utilization of two methodologies for carbaryl determination in tomatoes. The measurements were carried out using an amperometric biosensor technique based on the inhibition of acetylcholinesterase activity due to carbaryl adsorption and a HPLC procedure. The electrochemical experiments were performed in 0.1 mol L-1 phosphate buffer solutions at pH 7.4 with an incubation time of 8 min. The analytical curve obtained in pure solutions showed excellent linearity in the 5.0 x 10(-5) to 75 x 10(-5) mol L-1 range, with the limit of detection at 0.4 x 10(-3) gL(-1). The application of such a methodology in tomato samples involved solely liquidising the samples, which were spiked with 6.0 x 10(-6) and 5.0 x 10(-5) mol L-1 carbaryl. Recovery in such samples presented values of 99.0 and 92.4%, respectively. In order to obtain a comparison, HPLC experiments were also conducted under similar conditions. However, the tomato samples have to be manipulated by an extraction procedure (MSPD), which yielded much lower recovery values (78.3 and 84.8%, respectively). On the other hand, the detection limit obtained was much lower than that for the biosensor, i.e., 3.2 x 10(-6) g L-1. Finally, the biosensor methodology was employed to analyze carbaryl directly inside the tomato, without any previous manipulation. In this case, the biosensor was immersed in the tomato pulp, which had previously been spiked with the pesticide for 8 min, removed and inserted in the electrochemical cell. A recovery of 83.4% was obtained, showing very low interference of the matrix constituents. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A biomimetic sensor is proposed as a promising new analytical method for determination of captopril in different classes of samples. The sensor was prepared by modifying a carbon paste electrode with iron (II) phthalocyanine bis(pyridine) [FePe(dipy)] complex. Amperometric measurements in a batch analytical mode were first carried out in order to optimize the sensor response. An applied potential lower than 0.2 V vs Ag vertical bar AgCl in 0.1 mol L(-1) of TRIS buffer at pH 8.0 provided the best response, with a linear range of 2.5 x 10(-5) to 1.7 x 10(-4) mol L(-1). A detailed investigation of the selectivity of the sensor, employing seventeen other drugs, was also performed. Recovery studies were carried out using biological and environment samples in order to evaluate the sensor`s potential for use with these sample classes. Finally, the performance of the biomimetic sensor was optimized in a flow injection (FIA) system using a wall jet electrochemical cell. Under optimized flow conditions, a broad linear response range, from 5.0 x 10(-4) to 2.5 x 10(-2) mol L(-1), was obtained for captopril, with a sensitivity of 210 +/- 1 mu A L mol(-1).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An electrochemical approach to the formation of a protective surface film on Mg alloys immersed in the ionic liquid (IL), trihexyl(tetradecyl)phosphonium–bis 2,4,4-trimethylpentylphosphinate, was investigated in this work. Initially, cyclic voltammetry was used with the Mg alloy being cycled from OCP to more anodic potentials. EIS data indicate that, under these circumstances, an optimum level of protection was achieved at intermediate potentials (e.g., 0 or 0.25 V versus Ag/AgCl). In the second part of this paper, a small constant bias was applied to the Mg alloy immersed in the IL for extended periods using a novel cell design. This electrochemical cell allowed us to monitor in situ surface film formation on the metal surface as well as the subsequent corrosion behaviour of the metal in a corrosive medium. This apparatus was used to investigate the evolution of the surface film on an AZ31 magnesium alloy under a potential bias (between ±100 mV versus open circuit) applied for over 24 h, and the film evolution was monitored using electrochemical impedance spectroscopy (EIS). A film resistance was determined from the EIS data and it was shown that this increased substantially during the first few hours (independent of the bias potential used) with a subsequent decrease upon longer exposure of the surface to the IL. Preliminary characterization of the film formed on the Mg alloy surface using ToF-SIMS indicates that a multilayer surface exists with a phosphorous rich outer layer and a native oxide/hydroxide film underlying this. The corrosion performance of a treated AZ31 specimen when exposed to 0.1 M NaCl aqueous solution showed considerable improvement, consistent with electrochemical data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined the influence of triethyl and tributyl phosphite (TEP and TBP) additives on the electrochemical performance of lithium-ion cells. The cell performance of the TEP- and TBP-containing electrolytes was evaluated by cyclic voltammetry, thermogravimetric analysis, electrochemical impedance spectroscopy, Fourier transform infrared spectroscopy and scanning electron microscopy. The flammability of the electrolytes was also investigated by measuring the self-extinguishing time of the electrolytes. The results showed that the TEP and TBP additives suppressed the flammability of the electrolyte, with a significant improvement in cell performance observed for the TEP additive. In addition, TEP and TBP additives improved the thermal stability of the battery and its electrochemical cell performance. Overall, 5 wt% TEP and TBP can be used as a flame-retarding additive to improve the cell performance of Li-ion batteries due to the decrease in cell impedance and SEI formation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A low-cost system to generate, control and detect electrochemiluminescence using a mobile smartphone is described. A simple tone-detection integrated circuit is used to switch power sourced from the phone's Universal Serial Bus (USB) 'On-The-Go' (OTG) port, using audible tone pulses played over the device's audio jack. We have successfully applied this approach to smartphones from different manufacturers and with different operating system versions. ECL calibrations of a common luminophore, tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)3]2+), with 2-(dibutylamino)ethanol (DBAE) as a co-reactant, showed no significant difference in light intensities when an electrochemical cell was controlled by a mobile phone in this manner, compared to the same calibration generated using a conventional potentiostat. Combining this novel approach to control the applied potential with the measurement of the emitted light through the smart phone camera (using an in-house built Android app), we explored the ECL properties of a water-soluble iridium(III) complex that emits in the blue region of the spectrum. The iridium(III) complex exhibited superior co-reactant ECL intensities and limits of detection to that of the conventional [Ru(bpy)3]2+ luminophore.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, some recent work on the flow induced by an external magnetic fields acting on electrochemical cell is reviewed. Although the influence of the magnetic field on the hydrodynamics has been studied for over 5 decades, the magnetohydrodynamics (MHD) remains relatively unfamiliar to all but a few research groups. There are nearly a countless number of dimensionless parameters in electrolytic flow (bubble induced flow) and MHD, but they have been introduced for convenience by different authors. The similitude parameter proposed by Solheim, Johansen, Rolseth, and Thonstad (1989) and Perron, Kiss, and Poncsák (2006) have been modified to provide a full set of parameters for electrolytic cell operating under external magnetic field. The bubble sliding characteristics underneath an inclined plane are studied using copper sulphate solution (as an electrolyte) in lab-based-scale and discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, chitosan was used as a coating of pure perlite in order to increase the accessibility of the groups OH- e NH2+the adsorptionof ions Mn2+ e Zn2+.The characterization results of the expanded perlite classified as microporous and whose surface area 3,176 m2 g-1after the change resulted in 4,664 m2g-1.From the thermogravimetry(TG) it was found that the percentage of coating was34,3%.The infrared analysis can prove the presence of groups Si-OH, Si-O e Al-O-Siresulting from the perlite and C=O, NH2and OH characterization of chitosan. The experiments on experiments on the adsorption of Mn and Zn were performed in the concentration range of10 a 50 mgL-1and the adsorption capacity inpH 5,8 e 5,2 was 19,49 and 23,09 mgg-1to 25 oC,respectively.The adsorption data were best fitted to Langmuir adsorption model to Langmuir adsorption model for both metalionsisindicative of monolayer adsorption. The kinetics of adsorption were calculated from the equation of Lagergren fitting the model pseudo-second-order for all initial concentrations, suggesting that adsorption of ions Mn2+ and Zn2+ follows the kinetics of pseudo-second-order and whose constant Speedk2(g/mg.min) are 0,105 e 3,98 and capacity and maximum removal qe 4,326 e 3,348,respectively.In this study we used a square wave voltammetry cathodic stripping voltammetry to quantify the adsorbed ions, and the working electrode glassy carbon, reference electrode silver / silver chloride and a platinum auxiliary electrode. The attainment of the peaks corresponding to ions Mn2+ and Zn2+ was evaluated in and electrochemical cell with a capacity of 30 mL using a buffer system (Na2HPO4/NaH2PO4)at pH 4 and was adjusted with solutionsH3PO4 0,1molL-1and NaOH 0,1 molL-1and addition of the analyte has been a cathodic peak in- 0,873 Vand detection limit of2,55x10-6molL-1para Zn.The dough used for obtaining the adsorption isotherm was 150 mg and reached in 120 min time of equilibrium for both metal ions.The maximum adsorption for 120 min with Mn concentration 20 mgL-1 and Zn 10 mgL-1,was91, 09 e 94, 34%, respectively

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A solid paraffin-based carbon paste electrode modified with 2-aminothiazole organofunctionalized silica (SiAt-SPCPE) was applied to Ni2+ determination in commercial ethanol fuel samples. The proposed method comprised four steps: (1) Ni2+ preconcentration at open circuit potential directly in the ethanol fuel sample, (2) transference of the electrode to an electrochemical cell containing DMG, (3) differential pulse voltammogram registering and (4) surface regeneration by polishing the electrode. The proposed method combines the high Ni2+ adsorption capacity presented by 2-aminothiazole organofunctionalized silica with the electrochemical properties of the Ni(DMG)2 complex, whose electrochemical reduction provides the analytical signal.All experimental parameters involved in the proposed method were optimized. Using a preconcentration time of 20 min, it was obtained a linear range from 7.5 x 10(-9) to 1.0 x 10(-6) mol L-1 with detection limit of 2.0 x 10(-9) mol L-1. Recovery values between 96.5 and 102.4% were obtained for commercial samples spiked with 1.0 mu mol L-1 Ni2+ and the developed electrode was totally stable in ethanolic solutions. The contents of Ni2+ found in the commercial samples using the proposed method were compared to those obtained by graphite furnace atomic absorption spectroscopy by using the F- and t-test. Neither the F- nor t-values exceeded the critical values at 95% confidence level, confirming that there are not statistical differences between the results obtained by both methods. These results indicate that the developed electrode can be successfully employed to reliable Ni2+ determination in commercial ethanol fuel samples without any sample pretreatment or dilution step. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)