976 resultados para Computed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the integration of constrained predictive control and computed-torque control, and its application on a six degree-of-freedom PUMA 560 manipulator arm. The real-time implementation was based on SIMULINK, with the predictive controller and the computed-torque control law implemented in the C programming language. The constrained predictive controller solved a quadratic programming problem at every sampling interval, which was as short as 10 ms, using a prediction horizon of 150 steps and an 18th order state space model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the accuracy of two imaging methods in diagnosing apical periodontitis (AP) using histopathological findings as a gold standard. Methods: The periapex of 83 treated or untreated roots of dogs` teeth was examined using periapical radiography (PR), cone-beam computed tomography (CBCT) scans, and histology. Sensitivity, specificity, predictive values, and accuracy of PR and CBCT diagnosis were calculated. Results: PR detected AP in 71% of roots, a CBCT scan detected AP in 84%, and AP was histologically diagnosed in 93% (p = 0.001). Overall, sensitivity was 0.77 and 0.91 for PR and CBCT, respectively. Specificity was 1 for both. Negative predictive value was 0.25 and 0.46 for PR and CBCT, respectively. Positive predictive value was 1 for both. Diagnostic accuracy (true positives + true negatives) was 0.78 and 0.92 for PR and CBCT (p = 0.028), respectively. Conclusion: A CBCT scan was more sensitive in detecting AP compared with PR, which was more likely to miss AP when it was still present. (J Endod 2009;35:1009-1012)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the favorable outcome of root canal treatment determined by periapical radiographs (PRs) and cone beam computed tomography (CBCT) scans. Ninety-six roots of dogs` teeth were used to form four groups (n = 24). In group 1, root canal treatments were performed in healthy teeth. Root canals in groups 2 through 4 were infected until apical periodontitis (AP) was radiographically confirmed. Roots with AP were treated by one-visit therapy in group 2, by two-visit therapy in group 3, and left untreated in group 4. The radiolucent area in the PRs and the volume of CBCT-scanned periapical lesions were measured before and 6 months after the treatment. In groups 1, 2, and 3, a favorable outcome (lesions absent or reduced) was shown in 57 (79%) roots using PRs but only in 25 (35%) roots using CBCT scans (p = 0.0001). Unfavorable outcomes occurred more frequently after one-visit therapy than two-visit therapy when determined by CBCT scans (p = 0.023). (J Endod 2009; 35:723-726)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we evaluate the effectiveness of computed tomography images as a tool to determine magnetic nanoparticle biodistribution over biological tissues. For this purpose, tomography images for magnetic nanoparticles, composed of Fe(3)O(4), coated with 2,3-dimercaptosuccinic acid (DMSA), were generated at several material concentrations. The comparison of CT numbers, calculated from these images generated at clinical conditions, with typical CT numbers for biological tissues, shows that the detection of nanoparticle in most tissues is only possible for high material concentrations. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We present an iterative framework for CT reconstruction from transmission ultrasound data which accurately and efficiently models the strong refraction effects that occur in our target application: Imaging the female breast. Methods: Our refractive ray tracing framework has its foundation in the fast marching method (FNMM) and it allows an accurate as well as efficient modeling of curved rays. We also describe a novel regularization scheme that yields further significant reconstruction quality improvements. A final contribution is the development of a realistic anthropomorphic digital breast phantom based on the NIH Visible Female data set. Results: Our system is able to resolve very fine details even in the presence of significant noise, and it reconstructs both sound speed and attenuation data. Excellent correspondence with a traditional, but significantly more computationally expensive wave equation solver is achieved. Conclusions: Apart from the accurate modeling of curved rays, decisive factors have also been our regularization scheme and the high-quality interpolation filter we have used. An added benefit of our framework is that it accelerates well on GPUs where we have shown that clinical 3D reconstruction speeds on the order of minutes are possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction:
Low dose spiral computed tomography (CT) is a sensitive screening tool for lung cancer that is currently being evaluated in both non-randomised studies and randomised controlled trials.
Methods:
We conducted a quantitative decision analysis using a Markov model to determine whether, in the Australian setting, offering spiral CT screening for lung cancer to high risk individuals would be cost-effective compared with current practice. This exploratory analysis was undertaken predominantly from the perspective of the government as third-party funder. In the base-case analysis, the costs and health outcomes (life-years saved and quality-adjusted life years) were calculated in a hypothetical cohort of 10,000 male current smokers for two alternatives: (1) screen for lung cancer with annual CT for 5 years starting at age 60 year and treat those diagnosed with cancer or (2) no screening and treat only those who present with symptomatic cancer.
Results:
For male smokers aged 60–64 years, with an annual incidence of lung cancer of 552 per 100,000, the incremental cost-effectiveness ratio was $57,325 per life-year saved and $105,090 per QALY saved. For females aged 60–64 years with the same annual incidence of lung cancer, the cost-effectiveness ratio was $51,001 per life-year saved and $88,583 per QALY saved. The model was used to examine the relationship between efficacy in terms of the expected reduction in lung cancer mortality at 7 years and cost-effectiveness. In the base-case analysis lung cancer mortality was reduced by 27% and all cause mortality by 2.1%. Changes in the estimated proportion of stage I cancers detected by screening had the greatest impact on the efficacy of the intervention and the cost-effectiveness. The results were also sensitive to assumptions about the test performance characteristics of CT scanning, the proportion of lung cancer cases overdiagnosed by screening, intervention rates for benign disease, the discount rate, the cost of CT, the quality of life in individuals with early stage screen-detected cancer and disutility associated with false positive diagnoses. Given current knowledge and practice, even under favourable assumptions, reductions in lung cancer mortality of less than 20% are unlikely to be cost-effective, using a value of $50,000 per life-year saved as the threshold to define a “cost-effective” intervention.
Conclusion:
The most feasible scenario under which CT screening for lung cancer could be cost-effective would be if very high-risk individuals are targeted and screening is either highly effective or CT screening costs fall substantially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral quantitative computed tomography (pQCT) has mainly been used as a research tool in children. To evaluate the clinical utility of pQCT and formulate recommendations for its use in children, the International Society
of Clinical Densitometry (ISCD) convened a task force to review the literature and propose areas of consensus and future research. The types of pQCT technology available, the clinical application of pQCT for bone health assessment in children, the important elements to be included in a pQCT report, and quality control monitoring techniques were evaluated. The review revealed a lack of standardization of pQCT techniques, and a paucity of data regarding differences between pQCT manufacturers, models and software versions and their impact in pediatric assessment. Measurement sites varied across studies. Adequate reference data, a critical element for interpretation of pQCT results, were entirely lacking, although some comparative data on healthy children were available. The elements of the
pQCT clinical report and quality control procedures are similar to those recommended for dual-energy X-ray absorptiometry. Future research is needed to establish evidence-based criteria for the selection of the measurement site, scan acquisition and analysis parameters, and outcome measures. Reference data that sufficiently characterize the normal range of variability in the population also need to be established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an emergency department (ED), computed tomography (CT) is particularly beneficial in the investigation of high-speed trauma patients. With the advent of multidetector CT (MDCT) scanners, it is becoming faster and easier to conduct scans. In recent years, this has become evident with an increasing number of CT requests. Patients who have multiple CT scans during their hospital stay can receive radiation doses that have an increased theoretical risk of induction of cancer. It is essential that the clinical justification for each CT scan be considered on an individual basis and that due consideration is given to the radiation risk and possible diagnostic benefit. The current lack of a central State or Commonwealth data repository for medical images is a contributing factor to excessive radiation dosage to the population. The principles of justification and radiation risks are discussed in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aim: The study investigated the relationship between indices of adiposity measured by peripheral quantitative computed tomography (pQCT) and dual-energy X-ray absorptiometry (DXA) in pre-pubertal children.

Subjects and methods: DXA-derived per cent body fat (%BF) was measured in 284 boys and 288 girls, aged 7–10 years. Cross-sections of the forearm (n=427) and lower leg (n=560) were obtained by pQCT to measure total cross-sectional area of the limb (Total CSA), Muscle CSA, Fat CSA, %Fat CSA (Fat CSA/Total CSA×100) and muscle density.

Results: Peripheral QCT-derived %Fat CSA in the forearm and lower leg correlated strongly with DXA-derived %BF (r=0.83–0.89, p<0.01) in both boys and girls. However, forearm and lower leg %Fat CSA were higher than whole body %BF by 5% and 10%, respectively. A better prediction of whole-body %BF was achieved by including %Fat CSA, muscle density and height into a hierarchical regression model. Using sex-specific regression equations, 87.7% of the boys and 83.7% of the girls had a predicted %BF within 3% units of the %BF obtained by DXA.

Conclusion:
In pre-pubertal children, pQCT measures of adiposity are strongly associated with whole-body per cent body fat. This reproducible method could be an alternative technique to estimate body composition in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung nodules refer to a range of lung abnormalities the detection of which can facilitate early treatment for lung patients. Lung nodules can be detected by radiologists through examining lung images. Automated detection systems that locate nodules of various sizes within lung images can assist radiologists in their decision making. This paper presents a study of the existing methods on automated lung nodule detection. It introduces a generic structure for lung nodule detection that can be used to represent and describe the existing methods. The structure consists of a number of components including: acquisition, pre-processing, lung segmentation, nodule detection, and false positives reduction. The paper describes the algorithms used to realise each component in different systems. It also provides a comparison of the performance of the existing approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : To determine the interobserver agreement and diagnostic performance characteristics of computed tomography (CT) for determining union of scaphoid waist fractures.

Methods : A total of 59 orthopedic and trauma surgeons rated for union a set of 30 sagittal CT scans of 30 scaphoid waist fractures. Of these fractures, 20 were treated nonoperatively, were imaged between 6 and 10 weeks after injury, and were known to have eventually achieved union. Ten were operatively confirmed to be ununited. We rated each scan as united or ununited using a Web-based rating application. We assessed interobserver reliability using Siegel's multirater Kappa. We calculated diagnostic performance characteristics using Bayesian formulas.

Results : The interobserver agreement among 59 raters was substantial. The average sensitivity, specificity, and accuracy of diagnosing union of scaphoid waist fractures on sagittal CT scans were 78%, 96%, and 84%, respectively. Assuming a 90% prevalence of fracture union of the scaphoid, the positive predictive value of a diagnosis of union on sagittal CT scan was 0.99 and the negative predictive value was 0.41.

Conclusions : Our results suggest that CT scans are accurate and reliable for diagnosis of union but inadequate for ruling out nonunion of scaphoid waist fractures between 6 and 10 weeks after injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : This study tests the hypothesis that 3-dimensional computed tomography (CT) reconstructions improve interobserver agreement on classification and treatment of coronoid fractures compared with 2-dimensional CT.

Methods : A total of 29 orthopedic surgeons evaluated 10 coronoid fractures on 2 occasions (first with radiographs and 2-dimensional CT and then with radiographs and 3-dimensional CT), separated by a minimum of 2 weeks. Surgeons classified fractures according to the classifications of Regan and Morrey and of O'Driscoll et al., identified specific characteristics, recommended the most appropriate treatment approach, and made treatment recommendations. The kappa multirater measure (κ) was calculated to estimate agreement between observers.

Results : Regardless of the imaging modality used, there was fair to moderate agreement for most of the observations. Three-dimensional CT improved interobserver agreement in Regan and Morrey's classsication (κ3-dimensional = 0.51 vs κ2-dimensional = 0.40; p < .001) and O'Driscoll et al.'s classifications (κ3-dimensional = 0.48 vs κ2-dimensional = 0.42; p = .009). There were trends toward better reliability for 3-dimensional reconstruction in recognition of coronoid tip fractures (κ3-dimensional = 0.19, κ2-dimensional = 0.03; p = .268), comminution (κ3-dimensional = 0.41 vs κ2-dimensional = 0.29; p = .133), and impacted fragments (κ3-dimensional = 0.39 vs κ2-dimensional = 0.27; p = .094), and in surgeons' opinions on the need for something other than screws or plate for surgical fixation (κ3-dimensional = 0.31 vs κ2-dimensional = 0.15; p = .138). Interobserver agreement on treatment approach was better with 2-dimensional CT (κ3-dimensional = 0.27, κ2-dimensional = 0.32; p = .015).

Conclusions :
Three-dimensional CT reconstructions improve interobserver agreement with respect to fracture classification compared with 2-dimensional CT.