987 resultados para Axial Flux Motor-in-Wheel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Design. A cross-sectional case-control study. Objectives. To examine the effect of fatigue on torque output as well as electromyographic frequency and amplitude values of trunk muscles during isometric axial rotation exertion in back pain patients and to compare the results with a matched control group. Summary of Background Data. Back pain patients exhibited different activation strategies in trunk muscles during the axial rotation exertions. Fatigue changes of abdominal and back muscles during axial rotation exertion have not been examined in patients with back pain. Methods. Twelve back pain patients and 12 matched controls performed isometric fatiguing axial rotation to both sides at 80% maximum voluntary contraction in a standing position. During the fatiguing exertion, electromyographic changes of rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum, and multifidus were recorded bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were also measured. Results. No difference in the endurance capacity was found between back pain and control groups. At the initial period of the exertion, back pain patients demonstrated a statistical trend (P = 0.058) of greater sagittal coupling torque as well as lower activity of rectus abdominis and multifidus and higher activity in external oblique. During the fatigue process similar changes of coupling torque were demonstrated in both sagittal and coronal planes, but a smaller fatigue rate for right external oblique, increase in median frequency for latissimus dorsi, and lesser increase in activity for back muscles were found in the back pain group compared with the control group. Conclusions. Alterations in electromyographic activation and fatigue rates of abdominal and back muscles demonstrated during the fatigue process provide insights into the muscle dysfunctions in back pain and may help clinicians to devise more rational treatment strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is an easily automated, reliable technique to investigate axial mixing within rotating drums. Moist bran can be clearly differentiated from dry bran using MRI allowing a non-segregating tracer for axial mixing. For a 20-cm diameter drum, the axial dispersion coefficient in the particle bed was 0.51 cm s(-2). Axial dispersion is scale-dependent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the initiation of and response to tumor necrosis factor (TNF) inhibitors for axial spondyloarthritis (axSpA) in private rheumatology practices versus academic centers. METHODS: We compared newly initiated TNF inhibition for axSpA in 363 patients enrolled in private practices with 100 patients recruited in 6 university hospitals within the Swiss Clinical Quality Management (SCQM) cohort. RESULTS: All patients had been treated with ≥ 1 nonsteroidal antiinflammatory drug and > 70% of patients had a baseline Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) ≥ 4 before anti-TNF agent initiation. The proportion of patients with nonradiographic axSpA (nr-axSpA) treated with TNF inhibitors was higher in hospitals versus private practices (30.4% vs 18.7%, p = 0.02). The burden of disease as assessed by patient-reported outcomes at baseline was slightly higher in the hospital setting. Mean levels (± SD) of the Ankylosing Spondylitis Disease Activity Score were, however, virtually identical in private practices and academic centers (3.4 ± 1.0 vs 3.4 ± 0.9, p = 0.68). An Assessment of SpondyloArthritis international Society (ASAS40) response at 1 year was reached for ankylosing spondylitis in 51.7% in private practices and 52.9% in university hospitals (p = 1.0) and for nr-axSpA in 27.5% versus 25.0%, respectively (p = 1.0). CONCLUSION: With the exception of a lower proportion of patients with nr-axSpA newly treated with anti-TNF agents in private practices in comparison to academic centers, adherence to ASAS treatment recommendations for TNF inhibition was equally high, and similar response rates to TNF blockers were achieved in both clinical settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The heart relies on continuous energy production and imbalances herein impair cardiac function directly. The tricarboxylic acid (TCA) cycle is the primary means of energy generation in the healthy myocardium, but direct noninvasive quantification of metabolic fluxes is challenging due to the low concentration of most metabolites. Hyperpolarized (13)C magnetic resonance spectroscopy (MRS) provides the opportunity to measure cellular metabolism in real time in vivo. The aim of this work was to noninvasively measure myocardial TCA cycle flux (VTCA) in vivo within a single minute. METHODS AND RESULTS: Hyperpolarized [1-(13)C]acetate was administered at different concentrations in healthy rats. (13)C incorporation into [1-(13)C]acetylcarnitine and the TCA cycle intermediate [5-(13)C]citrate was dynamically detected in vivo with a time resolution of 3s. Different kinetic models were established and evaluated to determine the metabolic fluxes by simultaneously fitting the evolution of the (13)C labeling in acetate, acetylcarnitine, and citrate. VTCA was estimated to be 6.7±1.7μmol·g(-1)·min(-1) (dry weight), and was best estimated with a model using only the labeling in citrate and acetylcarnitine, independent of the precursor. The TCA cycle rate was not linear with the citrate-to-acetate metabolite ratio, and could thus not be quantified using a ratiometric approach. The (13)C signal evolution of citrate, i.e. citrate formation was independent of the amount of injected acetate, while the (13)C signal evolution of acetylcarnitine revealed a dose dependency with the injected acetate. The (13)C labeling of citrate did not correlate to that of acetylcarnitine, leading to the hypothesis that acetylcarnitine formation is not an indication of mitochondrial TCA cycle activity in the heart. CONCLUSIONS: Hyperpolarized [1-(13)C]acetate is a metabolic probe independent of pyruvate dehydrogenase (PDH) activity. It allows the direct estimation of VTCA in vivo, which was shown to be neither dependent on the administered acetate dose nor on the (13)C labeling of acetylcarnitine. Dynamic (13)C MRS coupled to the injection of hyperpolarized [1-(13)C]acetate can enable the measurement of metabolic changes during impaired heart function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena oli luoda työkalu kestomagneettikoneiden roottoreiden väsymisen analysointia varten. Työkalu toteutettiin siten, että siihen voidaan liittää oikeasta koneesta mitattu kuormitusdata, sekä tarvittavat materiaalitiedot. Kuormitusdata muunnetaan työkalussa jännityshistoriaksi käyttämällä elementtimenetelmän avulla laskettavaa skaalauskerrointa. Kestoiän laskemiseen analyysityökalu käyttää jännitykseen perustuvaa menetelmää sekä rainflowmenetelmää ja Palmgren-Minerin kumulatiivista vauriosääntöä. Lisäksi työkalu tekee tutkittavalle tapaukselle Smithin väsymislujuuspiirroksen. Edellä mainittujen menetelmien lisäksi työn teoriaosassa esiteltiin väsymisanalyysimenetelmistä myös paikalliseen venymään perustuva menetelmä sekä murtumismekaniikka. Nämä menetelmät jäivät monimutkaisuutensa vuoksi toteuttamatta työkalussa. Väsymisanalyysityökalulla laskettiin kestoiät kahdelle esimerkkitapaukselle. Kummassakin tapauksessa saatiin tulokseksi ääretön kestoikä, mutta aksiaalivuokoneen roottorin dynaaminen varmuus oli pieni. Vaikka tulokset vaikuttavat järkeviltä, ne olisi vielä hyvä verifioida esimerkiksi kaupallisen ohjelmiston avulla täyden varmuuden saamiseksi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, it was adjusted a mathematical model to measure the effect of electric motor efficiency on pumping system costs for irrigation on the tariff structure of conventional electricity and green horo-seasonal , and also to calculate the recovery period of the invested capital in higher efficiency equipment. Then, it was applied to a center pivot irrigation system in two options of electric motor efficiency, 92,6% (standard line) and 94,3% (high efficiency line), and the acquisition cost of the first corresponded to 70% the of the second. The power of the electric motor was 100hp. The results showed that the model allowed us to evaluate if a high efficiency motor was economically viable compared to the standard motor in each tariff structure. The high efficiency motor was not viable in the two tariff structures. In the green horo-seasonal tariff, would only be viable if its efficiency was 4.46% higher than the standard motor. In the conventional tariff, it would only be viable if the efficiency overcame 2.71%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hissiteollisuudessa nostokoneistoina käytettyjen sähkömoottoreiden laatuvaatimukset ovat tiuken-tuneet viime vuosina. Erityisesti koneistojen tuottama ääni ja mekaaninen värähtely ovat olleet jat-kuvasti tiukentuneen tarkastelun alaisena. Hissikoriin ja hissiä ympäröiviin rakenteisiin välittyvästä värähtelystä johtuva ääni on yksi hissin laatuvaikutelmaan merkittävimmin vaikuttavia tekijöitä. Nostokoneisto on yksi tärkeimmistä äänen ja värähtelyn lähteistä hissijärjestelmässä. Koneiston suunnittelulla edellä mainittuja tekijöitä voidaan minimoida. Sähkökoneiden suunnittelussa finiit-tielementtimenetelmien (FEM) käyttö on vakiintunut haastavimmissa sovelluksissa. Kone Oyj:llä nostokoneistoina käytetään aksiaalivuokestomagneettitahtikoneita (AFPMSM), joiden FEM simu-lointiin käytetään yleisesti kolmea eri tapaa. Kukin näistä vaihtoehdoista pitää sisällään omat hyö-tynsä, että haittansa. Suunnittelun kannalta tärkeää on oikean menetelmän valinta ai-ka/informatiivisuus suhteen maksimoimiseksi. Erittäin tärkeää on myös saatujen tulosten oikeelli-suus. Tämän diplomityön tavoite on kehittää järjestelmä, jonka avulla AFPMS-koneen voimia voidaan mitata yksityiskohtaisella tasolla. Järjestelmän avulla voidaan tarkastella käytössä olevien FE-menetelmien tulosten oikeellisuutta sekä äänen että värähtelyn syntymekanismeja. Järjestelmän tarkoitus on myös syventää Kone Oyj tietotaitoa AFPMS-koneiden toiminnasta. Tässä työssä esitellään AFPMS-koneen epäideaalisuuksia, jotka voivat vaikuttaa mittajärjestelmän suunnitteluun. Myös koneen epäideaalisuuksiin lukeutuvaa ääntä on tarkasteltu tässä työssä. Jotta työn tavoitteiden mukaista FE-menetelmien vertailua ja tulosten oikeellisuuden tarkastelua voitai-siin tehdä, myös yleisimpiä AFPMS-koneen FE-menetelmiä tarkastellaan. Työn tuloksena on mittajärjestelmän suunnitelma, jonka avulla voidaan toteuttaa kuuden vapausas-teen voimamittaus jokaiselle koneistomagneetille alle 1N resoluutiolla. Suunnitellun järjestelmän toimivuutta on tarkasteltu FE-menetelmiä käyttäen ja järjestelmässä käytettävän voima-anturin ky-vykkyyttä on todennettu referenssimittauksin. Suunniteltu mittajärjestelmä mahdollistaa sähkömoottorin useiden eri epäideaalisuuksien tarkaste-lun yksityiskohtaisella tasolla. Mittausajatuksen soveltaminen myös muiden koneiden tutkimiseen tarjoaa mahdollisuuksia jatkotutkimuksille.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the seasonal patterns of water vapor and sensible heat flux along a tropical biome gradient from forest to savanna. We analyzed data from a network of flux towers in Brazil that were operated within the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA). These tower sites included tropical humid and semideciduous forest, transitional forest, floodplain (with physiognomies of cerrado), and cerrado sensu stricto. The mean annual sensible heat flux at all sites ranged from 20 to 38 Wm(-2), and was generally reduced in the wet season and increased in the late dry season, coincident with seasonal variations of net radiation and soil moisture. The sites were easily divisible into two functional groups based on the seasonality of evaporation: tropical forest and savanna. At sites with an annual precipitation above 1900 mm and a dry season length less than 4 months (Manaus, Santarem and Rondonia), evaporation rates increased in the dry season, coincident with increased radiation. Evaporation rates were as high as 4.0 mm d(-1) in these evergreen or semidecidous forests. In contrast, ecosystems with precipitation less than 1700 mm and a longer dry season (Mato Grosso, Tocantins and Sao Paulo) showed clear evidence of reduced evaporation in the dry season. Evaporation rates were as low as 2.5 mm d(-1) in the transitional forests and 1 mm d(-1) in the cerrado. The controls on evapotranspiration seasonality changed along the biome gradient, with evaporative demand (especially net radiation) playing a more important role in the wetter forests, and soil moisture playing a more important role in the drier savannah sites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the study and the implementation of the speed control for a three-phase induction motor of 1,1 kW and 4 poles using the neural rotor flux estimation. The vector speed control operates together with the winding currents controller of the stator phasis. The neural flux estimation applied to the vector speed controls has the objective of compensating the parameter dependences of the conventional estimators in relation to the parameter machine s variations due to the temperature increases or due to the rotor magnetic saturation. The implemented control system allows a direct comparison between the respective responses of the speed controls to the machine oriented by the neural rotor flux estimator in relation to the conventional flux estimator. All the system control is executed by a program developed in the ANSI C language. The main DSP recources used by the system are, respectively, the Analog/Digital channels converters, the PWM outputs and the parallel and RS-232 serial interfaces, which are responsible, respectively, by the DSP programming and the data capture through the supervisory system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho apresenta uma bancada para testes em geradores elétricos, utilizados em aerogeradores de pequeno porte. O sistema é composto basicamente por um motor de indução trifásico, que simula um rotor eólico, acoplado mecanicamente ao gerador elétrico submetido ao ensaio; um inversor de frequência, usado para variação da velocidade do motor; transdutores de grandezas elétricas, que efetuam a medição dos parâmetros de interesse (tensões e correntes instantâneas) na saída do gerador; um sensor de velocidade angular, para medição da rotação que é fornecida ao eixo do motor; um microcomputador, para monitoração e armazenamento dos parâmetros medidos, e controle do inversor de frequência, por meio de um programa computacional desenvolvido; e uma placa de aquisição de dados, que serve como interface entre os transdutores/sensores e o microcomputador. A velocidade angular fornecida ao gerador em ensaio pode ser variada conforme valores fornecidos de velocidades de vento, as quais são associadas a valores correspondentes de rotação, a fim de simular o comportamento de um rotor eólico. Dessa forma, é possível traçar a curva de potência (potência versus velocidade de vento) do gerador ensaiado e analisar seu desempenho. Apresenta-se também neste trabalho os resultados de medições realizadas na bancada, referentes aos ensaios de um gerador comercial de pequena potência (1 kW) e de outro desenvolvido em projeto de pesquisa, ambos do tipo de imã permanente com fluxo axial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents experimental results for flow boiling heat transfer coefficient and critical heat flux (CHF) in small flattened tubes. The tested flattened tubes have the same equivalent internal diameter of 2.2 mm, but different aspect height/width ratios (H/W) of 1/4, 1/2, 2 and 4. The experimental data were compared against results for circular tubes using R134a and R245fa as working fluids at a nominal saturation temperature of 31 degrees C. For mass velocities higher than 200 kg/m(2)s, the flattened and circular tubes presented similar heat transfer coefficients. Such a behavior is related to the fact that stratification effects are negligible under conditions of higher mass velocities. Heat transfer correlations from the literature, usually developed using only circular-channel experimental data, predicted the flattened tube results for mass velocities higher than 200 kg/m(2)s with mean absolute error lower than 20% using the equivalent diameter to account for the geometry effect. Similarly, the critical heat flux results were found to be independent of the tube aspect ratio when the same equivalent length was kept. Equivalent length is a new parameter which takes into account the channel heat transfer area. The CHF correlations for round tubes predicted the flattened tube data relatively well when using the equivalent diameter and length. Furthermore, a new proposed CHF correlation predicted the present flattened tube data with a mean absolute error of 5%. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Field experiments have demonstrated that piles driven into sand can respond to axial cyclic loading in Stable, Unstable or Meta-Stable ways, depending on the combinations of mean and cyclic loads and the number of cycles. An understanding of the three styles of responses is provided by experiments involving a highly instrumented model displacement pile and an array of soil stress sensors installed in fine sand in a pressurised calibration chamber. The different patterns of effective stress developing on and around the shaft are reported, along with the results of static load tests that track the effects on shaft capacity. The interpretation links these observations to the sand's stress strain behaviour. The interface-shear characteristics, the kinematic yielding, the local densification, the growth of a fractured interface-shear zone and the restrained dilatancy at the pile soil interface are all found to be important. The model tests are shown to be compatible with the full-scale behaviour and to provide key information for improving the modelling and the design rules. (C) 2012 The Japanese Geotechnical Society. Production and hosting by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Máster en Oceanografía. Programa de Doctorado en Oceanografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the initiation of and response to tumor necrosis factor (TNF) inhibitors for axial spondyloarthritis (axSpA) in private rheumatology practices versus academic centers. METHODS We compared newly initiated TNF inhibition for axSpA in 363 patients enrolled in private practices with 100 patients recruited in 6 university hospitals within the Swiss Clinical Quality Management (SCQM) cohort. RESULTS All patients had been treated with ≥ 1 nonsteroidal antiinflammatory drug and > 70% of patients had a baseline Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) ≥ 4 before anti-TNF agent initiation. The proportion of patients with nonradiographic axSpA (nr-axSpA) treated with TNF inhibitors was higher in hospitals versus private practices (30.4% vs 18.7%, p = 0.02). The burden of disease as assessed by patient-reported outcomes at baseline was slightly higher in the hospital setting. Mean levels (± SD) of the Ankylosing Spondylitis Disease Activity Score were, however, virtually identical in private practices and academic centers (3.4 ± 1.0 vs 3.4 ± 0.9, p = 0.68). An Assessment of SpondyloArthritis international Society (ASAS40) response at 1 year was reached for ankylosing spondylitis in 51.7% in private practices and 52.9% in university hospitals (p = 1.0) and for nr-axSpA in 27.5% versus 25.0%, respectively (p = 1.0). CONCLUSION With the exception of a lower proportion of patients with nr-axSpA newly treated with anti-TNF agents in private practices in comparison to academic centers, adherence to ASAS treatment recommendations for TNF inhibition was equally high, and similar response rates to TNF blockers were achieved in both clinical settings.